VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

Similar documents
EM270. Multi-channel power analyzer. Benefits. Description

EM271. Multi-channel power analyzer. Benefits. Description

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

WM20. Power analyzer for three-phase systems. Benefits. Description

Multichannel power analyzer for single, two and three-phase systems

VMU-MC. Pulse concentrator. Operating instruction

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Energy Management BUS Adapter Type VMU-B 01

Energy Management BUS Adapter Type VMU-B

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Energy Management Energy Transducer Type ET112

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

protocol can be used. The SB2WEB24 is also equipped with an RS485 port for communication

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

SH2WEB24. Central unit module. Benefits. Description

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter

SA2WEB24. Central unit module. Benefits. Description

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

VMU-C EM system. Integrated modular system to monitor conventional energy. Benefits. Description

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Jiaxing Eastron Electronic Instruments Co.,Ltd. Tel: Fax:

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

How to monitor M-Bus and wireless M-Bus systems

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

smart-house Controller Central Unit Module Type SH2WEB24

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

MIC-2 MKII, Multi-instrument DATA SHEET

Electrical network management. Schneider Electric. EM4200 Technical Datasheet

MCX06C Programmable controller

MCX08M2 Programmable controller

User Manual V1.1. SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter

Energy Management Modular Energy meters Type EM2-96

GS Dupline Profinet Gateway. Benefits. Description

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

RM35TF V AC

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

B5X-LS4-U. Light switch. Benefits. Description

Programmable controller Type MCX06C

MIC-2 Multi-instrument DATA SHEET

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

Installation Instructions

SensoTrans DMS A 20220

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Communication module to connect M-bus devices to POL6xx.xxx controllers.

XPSMC16ZCPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

USER MANUAL 2012 V1.1

MODEL: GR8-EM. Communication Adaptor GR8 Series

Programmable controller MCX06C

Signal Doublers. VariTrans A 20300

User Manual V1.0 SDM230-DR. Single-Phase Two Module DIN rail Meters

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

SensoTrans DMS P 32200

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Mini Energy Web Server

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Programmable Relay ZEN V2 Units

XPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

PowerLogic EM4000 series

SBB4I2O230 ENG. Fire damper I/O Module. Benefits. Description

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

EM100 Series and ET100 Series

LINETRAXX RCMS150. Residual current monitor type B with integrated measuring current transformers for earthed AC/DC systems (TN and TT systems)

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

EngyVolt RV12 and RV15

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

EM300 Series. ET300 Series

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

Digital input modules

ANALIZZATORE DI RETE TRIFASE 90A

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

mark150s mark150/485s DDC controllers Summary

Power Meter PowerMonitor 500

TM3AI4 module TM3-4 analog inputs

RM35LM33MW liquid level control relay RM35-L V AC/DC

Transcription:

Pulse concentrator VMU-MC is a pulse concentrator that makes totalizers available to master systems (i.e.: VMU-C EM) via Modbus RTU protocol. Furthermore, it controls up to three accessory modules via local bus to integrate from to a maximum of digital inputs. Each module controls up to three digital inputs, connected via local bus and powered by VMU-MC. Benefits Modularity. The VMU-MC module can be used singularly or with the addition of modules (from to 3) based on the number of meters to be monitored. Compact and retrofit products. VMU-MC and VMU- OC are suited for small spaces and existing systems with pulse output meters. Ease of installation. The modules can be mounted on DIN rail. Termination block. Supplied in the VMU-MC package, it easily and quickly terminates the RS485 port on the last device in the line. Free specific software. The system is compatible with UCS software that has a simple and intuitive interface. The software and subsequent updates are free. Configuration ease and flexibility. The units of measure and pulse weight of each input can be configured from UCS. Configurations can also be set off-line, saved and retrieved from UCS at any time. Elementary diagnostics. Correct system operations can be checked from UCS and the display. Easy integration with VMU-C EM. The UCS software is able to generate the driver to easily import input configurations in the VMU-C EM master. Applications Designed for commercial, residential and industrial applications, guarantee rapid installation with few easy connections. They are particularly indicated for: retrofit applications in existing distribution panels where data is to be collected from pre-existing pulse output meters utility type meters with pulse outputs All consumption data (i.e. electricity, gas, water, heat) of a commercial or industrial building or a residential home can be integrated in the same VMU-C EM master, enabling the following: precise cost allocation implementation of energy efficiency improvement policies check on correct operation and use of systems and machinery Main functions Read and concentrate pulse output meter data Transmit data read via serial communication to VMU-C EM or another master

Architecture UCS Desktop VMU-C Modbus RTU VMU-MC local bus Pulses local bus H O Pulses local bus Gas Heat Pulses H O Gas Heat Pulses H O Gas Heat H O Gas Main features Up to S0 digital inputs ( integrated and up to other 9 via modules) Up to 3 modules connected via local bus and powered by VMU-MC Input function: remote input status reading / tariff management / pulse counting Communication ports: RS485 Modbus RTU and local bus 6 digits LCD display (for VMU-MC only) Dimensions: from to 4 DIN modules according to the number of s Configurable from UCS

Layout (VMU-MC) A B C D H E F C G Area A B C D E F G H Termination block for serial output of the last device in the line Terminal block for RS485 port for communication with the master Digital input terminal block LCD display LED to indicate device status Button to scroll the display and set communication parameters Power supply terminal block Local bus port for module connection Layout () A B D C 3

Area A Digital input terminal block (+) B Digital input terminal block (-) Multipurpose LED: C device status identification of the module selected by VMU-MC Local bus ports D right side: connection to any module left side: connection to VMU-MC or another module 4

Features General Material Noryl Protection degree Front: IP40 Terminals: IP0 Terminals Cable section:.5 mm Torque: From 0.4 to 0.8 Nm Pollution degree VMU-MC Insulation Not insulated among power supply, inputs and RS485 port Inputs not insulated Insulation Towards power supply, VMU-MC inputs, RS485 port and other modules: 4 kv rms, 50 Hz/' Reinforced insulation, overvoltage cat. III, systems with voltage up to 300 V grounding Mounting On DIN rail Dimensions (mm) -DIN See figures Display 6 digits LCD Weight About 00 g (packaging included) 45 (.7) 90 (3.5) 45 (.7) 90 (3.5) 44 (.7) 8 (0.7) mm (in) 63 (.4) 49 (.9) Fig. VMU-MC dimensions mm (in) 63 (.4) 44 (.7) 49 (.9) Fig. dimensions 5 (0.9) 8 (0.7) Environmental specifications Operating temperature From -5 to +55 C/from -3 to +3 F Storage temperature From -30 to +70 C/from - to +58 F NOTE: R.H. < 95% non-condensing @ 40 C. 5

Conformity Directives Standards 0/65/EU (Electric-electronic equipment hazardous substances) 04/30/EU (EMC - Electro Magnetic Compatibility) 04/35/EU (LVT - Low Voltage) Safety requirements for electrical equipment for measurement, control and laboratory use: IEC600-/UL600- Devices with pulse outputs: IEC6053-3, S0 class B Electromagnetic compatibility (EMC) - emissions and immunity: EN636-. Approvals Power supply Power supply From 5 to 4 V dc, Cl. Consumption Maximum 00 ma Connector Screw terminals Digital intputs Number of inputs VMU-MC: : 3 Type S0, class B according to EN6053-3 (Imax <5 ma, Umax 5 V) Configuration parameters Frequency Functions Pulse weight Units of measure: kwh, kvarh, kvah, kj, kcal, m3, Nm3, h, pcs, kg Normal input status (normally open or normally closed) Minimum pulse duration filter (configurable from 5 ms to 300 ms) Maximum 00 Hz Pulse counting Input status reading* Tariff management* (VMU-MC only) Note *: not managed by VMU-C EM RS485 port Communication type Connection type Protocol Data Data format Configuration parameters Multidrop, bidirectional (static and dynamic variables) Screw terminals 3 wires Modbus RTU All start bit, 8 data bits, no parity/even/odd, or stop bit Modbus address (from to 47) Baud rate (9.6 / 9. / 38.4 kbps) Parity (None/ Odd/ Even) Stop bit ( or ) 6

Display Type Refresh time Information displayed Utilities LCD < s Status Totalizer (without decimals) Any active tariff View/edit communication parameters Check connected meter status operation and the state of each input 7

Connection Diagrams VMU-C EM/Master 3 3 3 Modbus RTU GND IN A(-) B(+) IN- IN IN IN3 - - - IN IN IN3 - - - IN IN IN3 - - - 0.4-0.8 Nm.5 mm² VMU-MC IN IN- + - 5 4 V dc - + 8

References Further reading Information Document Where to find it Installation, operating and maintenance instruction Instruction manual - VMU-MC www.productselection.net Installation, operating and maintenance instruction Instruction manual - www.productselection.net Datasheet VMU-C EM Datasheet www.productselection.net Modbus register map decryption Modbus protocol www.productselection.net CARLO GAVAZZI compatible components Purpose Component name/part number Notes Configure VMU-MC and generate the driver for Available for free download at: UCS configuration software VMU-C EM www.productselection.net Monitor data from several devices VMU-C EM See relevant datasheet Power VMU-MC SPM4 See relevant datasheet Connect to VMU-MC from PC via USB/RS485 converter SIU-PC3 See relevant datasheet How to order VMU-MC Code VMU-MC ASIEM Pulse concentrator with two integrated digital inputs How to order Code AI3XXEM Module with three digital inputs to integrate VMU-MC COPYRIGHT 08 Content subject to change. Download the PDF: www.productselection.net 9