TPE 1464 Series Pressure Transducer

Similar documents
Differential Liquid/Gas Pressure Transmitter

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

CDD Carbon Dioxide Transmitter

CDD4 Duct Carbon Dioxide Transmitter

CDD4 Series Room CO2 Transmitter Installation Instructions

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters

Level-Lance Model 5400A

Installation Guide. Carbon Dioxide (CO 2. ) Detectors. General Information. Mounting WARNING CAUTION. SAE-1011/1012 Space Mount SAE-1011/1012/1062

M5100 Heavy Industrial Pressure Transducer

Carbon Monoxide Sensor - ModBus

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

Zone Pressure Touch Sensor - Standard Range

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

M7100 Pressure Transducer

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

Zone Pressure Touch (ZPT) Sensor - Standard Range

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Pressure Transducer Model PR-264

PRESSURE TRANSMITTER

Installation & Operation Guide

Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11

U7100 Pressure Transducer

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

TOXALERT MODEL AIR 2000

MAXIMA+ Series Rotary Level Indicator

Limit Switch Box YT-870/875 SERIES

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Installation & Operation Guide

KOBOLD TDA Series Digital Temperature Transmitter

Suction Pressure Sensor

KOBOLD PDA Series Digital Pressure Transmitter

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

OZONE SWITCH Model OS-6. OS-6 Features

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

MAXIMA + Series ROTARY LEVEL CONTROL

Multi-Point Gas Detection and Control System

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

Differential Pressure Sensor

P216 Series Condenser Fan Speed Controller

Multi-Point Gas Detection and Control System

C-Flow Coriolis Mass Flow Meter

MODEL 8000MP LEVEL SENSOR

Electronic pressure switch with display Model PSD-4

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Bulletin 871L & 872L Limit Switch Style

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

User safety and equipment protection guidelines

Digital Level Sensor. Consistent accuracy, unparalleled reliability. Answers for energy.

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

MPS-32. Pressure Sensors MPS-32 2-Color Panel Mount. Features. Green Display. MPS-32 Programming Options

MAXIMA + Series ROTARY LEVEL CONTROL

Installation and Maintenance Instructions for GC31 Ultra-Compact Digital Pressure Sensor

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Multi-Point Gas Detection and Control System

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

0.01kV (0 to ±0.99 kv)

DD1590 Series Proximity Driver. Connection Technology Center, Inc. Vibration Analysis Hardware. DD1590 Series. Proximity Probe Driver.

Carbon Monoxide (CO) Gas Detection and Control System

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

Specifications - Installation and Operating Instructions. Duracell is a registered trademark of The Gillette Company.

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

Model 332 Differential Pressure Transmitter

HIGH ACCURACY PRESSURE TRANSDUCERS

iprox Sensing Solutions iprox Analog iprox Standard iprox Clone iprox Accessories iprox. The world s most versatile proximity sensor.

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

Dräger Polytron 8200 Stationary gas detector (CatEx)

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

Click Desktop Kit. Click Desktop Kit

DP DP2500 DP0250

Series ULT Ultrasonic Level Transmitter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

SDG1400 User s Guide

Analog Input Installation Manual

SP6R Level Controller Operation Manual

FLOW MONITOR & TRANSMITTER

Vision OPLC V TR20/V350-J-TR20

Model 7705 Control Module

EMS467 Monitoring System. Installation and Operations Manual Section 40

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Explosion-Proof Gauge Pressure Transmitter

Component identification

PP-8516 & PP Electronic Static Pressure Controllers and Transmitters for Cental Air Supply Systems General Instructions

OPERATING INSTRUCTIONS

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Safety Mats & Area Guarding

Control IT Booster Pump Controller

Vision OPLC V TR6/V350-J-TR6

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Transcription:

TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm stability. Up to four field-selectable input ranges are available in most models. The field selectable feature provides a single model that can be configured to cover all the input pressure ranges for any given application. Three output ranges are field selectable, 4 to 20mA, 0 to 5 VDC, and 0 to 10 VDC. The output signal is factory calibrated and temperature compensated for the highest start-up accuracy. The TPE 1464 can be powered from either a 24 VAC nominal, or 12 to 30 VDC power source. TPE 1464 incorporates a rugged NEMA 4 enclosure. Models The following models are available Features Push-button and remote zeroing terminal Normal or slow surge damping switch to prevent false alarms and reduce noise TPE 1464 1 TPE 1464 2 TPE 1464 3 Output polarity reverse switch Application 0 to 10/20/50/100 psig/d 0 to 20/40/100/200 psig/d 0 to 50/100/250/500 psig/d KMC TPE 1464 Pressure Transducers are suited for any application requiring a reliable pressure monitor providing a dependable conditioned and compensated signal output. The TPE 1464 may be used with any liquid or gas that is compatible with 17 4 PH stainless steel. DO NOT USE for these applications: Oxygen service Explosive/hazardous environments Flammable or combustible materials Specifications and design subject to change without notice.

Enclosure Specifications Media compatibility 17-4 PH stainless steel Supply Voltage 24 VAC or 15 to 30 VDC Supply Current 35 ma, maximum @ 24VDC Output Signal 4 to 20mA, 0 to 5 or 0 to 10 VDC, field selectable Pressure Ranges Field selectable: TPE-1464-1 0 to 10/20/50/100 psig/d TPE-1464-2 0 to 20/40/100/200 psig/d TPE-1464-3 0 to 50/100/250/500 psig/d Proof Pressure Max. 2X F.S. range Burst Pressure Max. 5X F.S. range Accuracy ±1% F.S. combined linearity, hysteresis, and repeatability. Range 4 accuracy ±2% F.S. Pressure cycles > 100 million Surge Damping normal 4-second averaging, slow 8-second averaging, switch selectable Sensor Operating Range -40 to 220 F (-40 to 105 C) Temperature Compensation Error 32 to 130 F (0 to 55 C) Long term stability ±0.25% typical (1 year) Zero Adjust push-button auto-zero and digital input Operating Environment 32 to 122 F (0 to 50 C), 10 to 90% RH, non-condensing Fittings 1/8 NPT female Enclosure 5" x 5" x 2.25" (127mm x 127mm x 57mm); IP 54 (NEMA 4) Weight 1.33 lbs. (.60 kg) Shock 100G, 11 msec, 1/2 sine Vibration 20G peak 20 to 2400 Hz KMC Controls, Inc. 19476 Industrial Drive New Paris, IN 46553 574.831.5250 www.kmccontrols.com 2005 KMC Controls Inc. 717-035-15D

Gage Pressure Transducer TPE-1464 Series Mounting Avoid locations with severe vibrations or excessive moisture. The enclosure has a standard ½" conduit opening and may be installed with either a conduit coupler or a cable gland type fitting. 1. Mount on a vertical surface with the pressure port and cable entrance on the bottom. 2. Use screws in the tab holes to fasten the assembly to the mounting surface. 3. Ensure there is enough space around the unit to make the pressure and electrical connections. Installation Guide WARNING: Do not use in explosive or hazardous environments, with combustible or flammable gasses, as a safety or emergency stop device, or in any other application where failure of the product could result in personal injury.!caution: Use electrostatic discharge precautions during installation and do not exceed device ratings. Plumbing 1. Use an appropriately rated pressure tubing for connections. 2. Arrange the tubing to minimize stress on the connections. 3. Do not allow debris to fall into the pressure ports, contamination can damage the sensor.

Wiring Use 22 AWG shielded wiring for all connections. Do not locate device wires in the same conduit as wiring supplying inductive loads. 1. Connect the positive DC voltage or the hot side of the AC voltage to the terminal marked PWR. 2. Connect the power supply common to the terminal marked COM. The device is reverse voltage protected and will not operate if connected backwards. The analog output signal is available on the OUT terminal. This signal is jumper selectable for either voltage or 4 to 20 ma output. In voltage mode, either 0 to 5 or 0 to 10 VDC can also be selected. The remote zero feature may be used by wiring a dry-contact (relay only) digital output to the ZERO terminals. Do not apply voltage to the ZERO terminals. This is an active device, turn off the input dip switches at the KMD and BACnet controllers. Set-Up CONFIGURATION Push-on jumpers and switches are used to select the output signal type, the input pressure range, and several features. The device is factory configured to operate in the 4 to 20 ma output mode but can be changed to voltage mode by moving the two jumpers from the positions marked 'Current' to the positions marked 'Voltage'. NOTE: Output jumpers can only be changed while the power is removed. CAUTION: Always note the current jumper position before moving them to the new position. If the jumpers are rotated 90 degrees and installed incorrectly the product will not work and damage may occur.

Set-Up Continued JUMPER SETTINGS Refer to the detailed drawing for pin location, the letter designations do not appear on the actual board. 0 to 5 VDC signal 0 1 to 10 VDC signal Connect A to B Connect B to C Voltage signal Current Signal For Backlight No Backlight Connect G to H Connect H to I Connect J to K Connect K to L RANGE The input pressure range is set by moving the 4-position slide switch marked RANGE. Range and Options switches can be changed while the unit is operating. PRESSURE RANGE MODEL 1 2 3 4 1464-1 100 PSI 50 PSI 20 PSI 10 PSI 1464-2 200 PSI 100 PSI 40 PSI 20 PSI 1464-3 500 PSI 250 PSI 100 PSI 50 PSI SLOW DAMPING The switch provides an 8-second averaging for surge dampening (normally it is 4-seconds). OUTPUT REVERSE Reverses the output signal polarity. In reverse mode the analog output is maximum when the gage pressure is zero and decreases as pressure increases. OPERATION The port is used to measure a positive pressure for normal operation such as 0 to 100 PSI 0 PSI = 4 ma 100 PSI = 20 ma. CALIBRATION This feature is enabled only when the detected pressure on the port is less than 5% of the full range to protect the unit from accidental zeroing. Span calibration should not be performed in the field unless a high quality calibrator is available. 1. Open the port to the ambient pressure or equalized at 0 pressure: 2. Press and hold the auto-zero button or provide contact closure on the ZERO terminals for at least 3 seconds. 3. Release the button or terminals and the device will calculate and store the new zero point.

Maintenance No routine maintenance is required. Each component is designed for dependable, long term reliability and performance. Careful installation will also ensure long term reliability and performance. KMC Controls 19476 Industrial Drive New Paris, IN 46553 TEL: 574.831.5250 FAX: 574.831.5252 E-mail: info@kmccontrols.com 717-019-03