Installation Guide Controller Series E130/E230/E430

Similar documents
MC-Link System Installation Guide

NEW. Servo Controller Series E1100 E1100-DP E1100-MP E1100-DN E1100-RS E1100-MT E1100-CO E1100-GP

Linear Motor Family P01-48x240

CAN-USB Converter Pro Installation Guide

CAN-USB Converter Installation Guide

E1200 Servo Drive Installation Guide

E1200 Servo Drive Installation Guide

C1100 Servo Drive Installation Guide

4.7 Expansion Module MAC00-FS1/FS4

4.8 Expansion Module MAC00-FS1/FS4

Servo Drives. Servo Drive E100/E1001. Series E100/E1001-AT/MT 330. Series E100/E1001-CO/DN 332. Series E130/E1031-DP

Please visit to check for the latest version of this document!

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

B1150 / B B

EtherCAT SoE Interface User Manual

C1100 Servo Drive Installation Guide

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Mounting Card MC1XDZR02-HP1

TRC-190 User s Manual

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Mounting Card MC1XDZR02-QD

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Mounting Card MC1XDZC02

F1000 User's Manual. (Version: V1.01)

PSU User s manual Rev. 0 January

XPSMCMDI Input expansion module with screw term

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

MDM 011-Z1 Regen Resistor

DeviceNet Interface User Manual

DENISON HYDRAULICS Jupiter Power Supply Accessory Series S

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

PSU. User s manual. Rev. 0

TSY 041 Training System Extension Motion

Operating instructions. Standstill monitor A / / 2011

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

VersaMax IP Input Module

VersaMax IP I/O Module

MOTION-8D 8-channel hoist controller with analogue remote control User s manual

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

XPSMCMDO Digital output pairs expansion modules with screw term

ACS-30-EU-MONI-RMM2-E

BACnet/IP Web Interface

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Digital DRIVE for Brushless motor MD Serial

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

XPSMCMMX inputs 2 output pairs expansion module with screw term

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

TXM1.8RB. TX-I/O Blinds module

SPiiPlusEC Network Manager Installation Guide November2014 Document Revision: 02

LVX Control Unit. Features:

GFK-2415A March Type of sensor connection

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Channel Switch CS. General Operating, Maintenance and Installation Manual

Operating instructions Evaluation system for flow sensors VS / / 2013

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

LinUDP Interface User Manual

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

MC 11 EB-2 Power supply cabinet with external bus, AC version

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

TRC-190 User s Manual

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva

ATV1200A kv kva

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

PDMnt Network Interface

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

Installation Instructions

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

5 Fieldbus Technology

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

DF PROFI II PC/104-Plus

MC-Link with ProfiNet Interface User Manual

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Installation Instructions

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Rugged MediaConverter

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

Four-channel DC Controller DMX Instruction &Maintenance Manual

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

TXP3500/4000 Series AC-DC Industrial PSU

Mounting Card MC1XDZPC01

DATASHEET. Ultra Capacitor Charger, UCC-4

DPO A4. Description. Module with 4 digital outputs. Datasheet

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

I/O module (Expansion module)

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

EA500. Installation Instructions Transponder

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Transcription:

Controller Series E0/0/0 Installation Guide Controller Series E0/E0/E0 Products E0-DP E0-DP E0-DP Content IMPORTANT NOTES FOR E0/E0/E0 SERIES CONTROLLERS... SYSTEM OVERVIEW... E0 SERIES FUNCTION AND WIRING... POWER SUPPLY AND GROUNDING... DESCRIPTION OF THE CONNECTORS / INTERFACES... POWER SUPPLY REQUIREMENT... 0 ORDERING INFORMATION... 0 DECLARATION OF CONFORMITY CE-MARKING... ERROR CODES... CONTACT ADDRESSES... NTI AG Installation: E0/E0/E0 series /.0.00 Page /

Controller Series E0/0/0 Important notes for E0/E0/E0 series controllers CAUTION!! In order to assure a safe and error free operation, and to avoid severe damage to system components, all system components must be directly attached to a single ground bus that is earth or utility grounded. Each system component should be tied directly to the ground bus (star pattern), rather than daisy chaining from component to component. (LinMot motors are properly grounded through their power cables when connected to LinMot controllers.) All connectors must not be connected or disconnected while DC voltage is present. Do not disconnect system components until all LinMot controller LED s have turned off. (Capacitors in the power supply may not fully discharge for several minutes after input voltage been disconnected). Failure to observe these precautions may result in severe damage to electronic components in LinMot motors and/or controllers. Do not switch Power Supply DC Voltage. All power supply switching and E-Stop breaks should be done to the AC supply voltage of the power supply. Do not connect or disconnect the motors from controllers with voltage present. Wait to connect or disconnect motors until all LinMot controller LED s have turned off. (Capacitors may not fully discharge for several minutes after power has been turned off). Failure to observe these precautions may result in severe damage to electronic components in LinMot motors and/or controllers. 00 NTI Ltd This work is protected by copyright. Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, microfilm, storing in an information retrieval system, not even for didactical use, or translating, in whole or in part, without the prior written consent of NTI AG. LinMot is a registered trademark of NTI AG. Note The information in this documentation reflects the stage of development at the time of press and is therefore without obligation. NTI AG. reserves itself the right to make changes at any time and without notice to reflect further technical advance or product improvement. NTI AG Installation: E0/E0/E0 series /.0.00 Page /

Controller Series E0/0/0 System Overview Power Supply Signal Fault Ready Stat A Stat B Mot A Profibus ID ID High ID Low Profibus DP Address Power Supply Signal... V Mot B DP Mot C Com Mot D PWR Profibus DP Interface RS Interface to PC for Configuration Power Supply Motor Power Supply Motor... V From AC Mains xv AC x0v AC From AC Mains xv AC x0v AC Linear Motor with internal Position Feedback Complete E0 Controller based system (E0 and E0 controllers will only drive one respectively two motors). Power Supply for Signal and Motor may be the same device (see later). NTI AG Installation: E0/E0/E0 series /.0.00 Page /

Controller Series E0/0/0 E0 series Function and Wiring Picture shows typical wiring of a single axes controller. Multiple axes controller will have additional motor connectors. NTI AG Installation: E0/E0/E0 series /.0.00 Page /

Controller Series E0/0/0 Power Supply and Grounding Power Supply signal AC-Mains - Circuit Breaker...VDC - Fuse Galvanically Isolated Power Supply: - Switch Mode Power Supply - Transformer with Rectifier Bridge = + - PWR signal Fault Ready Stat A Stat B Mot A Profibus DP Mot B DP ID High ID Low Ground Bus Mot C Com AC-Mains Emergency Stop Breaker Power Supply motor - Circuit Breaker...VDC - Fuse Galvanically Isolated Power Supply: - Switch Mode Power Supply - Transformer with Rectifier Bridge = + - PWR motor Mot D PWR PE All wires.mm (AWG) Instead of two separated power supplies it may be possible to use only one power supply if there is no need to control the signal power supply (logical devices of the controller) and the power supply of the powerstage for the motors independently (see safety rules of the application). In order to assure a safe and error free operation, and to avoid severe damage to system components, all system components must be well grounded to either a single earth or utility ground. This includes both LinMot and all other control system components to the same ground bus. Each system component should be tied directly to the ground bus (star pattern), rather than daisy chaining from component to component. (LinMot motors are properly grounded through their power cables when connected to LinMot controllers.) Power supply connectors must not be connected or disconnected while DC voltage is present. Do not disconnect system components until all LinMot controller LED s have turned off. (Capacitors in the power supply may not fully discharge for several minutes after input voltage been disconnected).failure to observe these precautions may result in severe damage to electronic components in LinMot motors and/or controllers. Do not switch Power Supply DC Voltage. All power supply switching and E-Stop breaks should be done to the AC supply voltage of the power supply. Failure to observe these precautions may result in severe damage to controller. NTI AG Installation: E0/E0/E0 series /.0.00 Page /

Controller Series E0/0/0 Description of the connectors / Interfaces Power Supply Power Connector...VDC...VDC Internal Fuse 00mAT Internal Fuse 0AT PWR Signal+ PWR Motor+ internally connected to controller housing PWR Signal + PWR Motor +...VDC...VDC Supply must be externally connected to earth (Ground Bus) Supply: Supply Voltage...VDC. Absolute max. Rating VDC + 0% Supply voltage for PWR Signal and PWR Motor may be different Motor Supply must be externally connected to earth Caution: By exceeding VDC supply voltage, the controller will go into error state. Voltage higher than VDC will damage the controller! Do not switch Power Supply DC Voltage. All power supply switching and E-Stop breaks should be done to the AC supply voltage of the power supplies Power supply connectors must not be connected or disconnected while DC voltage is present. Wiring:. mm² (AWG), max length m LED State Display Fault Ready Ready Green READY The system has started correctly Stat A Stat B Stat A Yellow Stat B Yelllow Fault red STAT A Coding for the actual operating state STAT B Coding for the actual operating state The display of the various operating states is shown on the last page of this manual. FAULT An error has occurred (In the state ERROR a blink code of the STAT LEDs A and B tells what the actual error is. The blink codes are explained in chapter Service of the user Manual.) NTI AG Installation: E0/E0/E0 series /.0.00 Page /

Controller Series E0/0/0 Mot A (B,C,D) Motor Connector Mot A (B,C,D) +VDC +VDC k k 0k DSUB- (female) Phase + Phase - Phase + Phase - +VDC A Sine Cosine Temp. black green yellow inner shield white grey blue pink red Extension Cable Outer shield connected to connector housing Note: - Use only special double-shielded Linear Motor Cable (see datasheet extension cables ) - Use +V (Pin ) and A (Pin ) only for motor internal Hall Sensor supply (max. 00mA). - Do NOT connect A (Pin ) to ground or earth! - Inner shield (A) and outer shield (earth) must be isolated to each other. Caution: - Wrong Motor wiring may damage Linear Motors and/or Servo Controller. - If you are assembling motor cables by your own, double check motor wiring carefully before power up. Do not connect or disconnect the motors from controllers with voltage present. Wait to connect or disconnect motors until all LinMot controller LED s have turned off. (Capacitors may not fully discharge for several minutes after power has been turned off).failure to observe these precautions may result in severe damage to electronic components in LinMot motors and/or controllers. Com COM (RS-) k0 DSUB- (male) RS- TX RS- RX RS:.kBaud, use : connection cable to PC NTI AG Installation: E0/E0/E0 series /.0.00 Page /

Controller Series E0/0/0 DP Profibus Connector DSUB- (female) Isolated V output: max 0 ma Profibus ID ID High ID Low ID : Profibus address high ID : Profibus address low NTI AG Installation: E0/E0/E0 series /.0.00 Page /

Controller Series E0/0/0 Mechanical Dimension Dimensions Fixings for x M screws Centers 0 LinMot -E00 Dimensions in mm 0 Recommended mounting for multiple controller installation Fixings for x M screws 00 LinMot -E00 LinMot -E00 LinMot -E00 00 0 0 00 0 0 Dimensions in mm NTI AG Installation: E0/E0/E0 series /.0.00 Page /

Controller Series E0/0/0 E0 Single axes controller E0 axes controller Width mm (in) 0 (.) Height mm (in) 0 (.) Height without fixings mm (in) (.) Depth mm (in) (.) E0 axes controller Weight Kg (lb). (.). (.). (.) Case IP 0 Storage Temperature C - 0 Operating Temperature C 0 0 Max. Case Temperature C Power Supply Requirement Power Supply motor The calculation of the needed power for the Motor supply is depending on the application and the used motor(s). The following table shows a recommendation for general applications. Controller Voltage/ Power LinMot Switched- Power Supply Part-Nr. E00 motor V / 0 W S0-/0 00-0 E00 Up to motors V / 00 W S0-/00 00- E00 Up to motors V / 00 W S0-/00 00- Power Supply signal V / W Regeneration of Power The Exxx controller don t use a regeneration resistor. In most application the recuperated energy will not become an issue. In cases where the motor power supply voltage will exceeds the voltage limits because of recuperation an additional capacitor between PWR motor and should be used. Typical: 000 uf. Ordering Information Servo Controller Description Art. No. E0-DP Profibus Controller Axis (V/A) 00- E0-DP Profibus Controller Axis (V/A) 00- E0-DP Profibus Controller Axis (V/A) 00- NTI AG Installation: E0/E0/E0 series /.0.00 Page 0/

Controller Series E0/0/0 Declaration of Conformity CE-Marking Manufacturer: Products: NTI AG LinMot Haerdlistrasse Spreitenbach Switzerland Tel.: + (0) Fax: + (0) LinMot Controllers Type Art.-No. Type Art-No. Type Art.-No. E0-DP 00- E0-DP 00- E0-DP 00- The product must be mounted and used in strict accordance with the installation instruction contained within the User s Manual, a copy of which may be obtained from NTI Ltd. I declare that as the authorized representative, the above information in relation to the supply/manufacture of this product is in conformity with the stated standards and other related documents in compliance with the protection requirements of the EMC Directive (//EEC) and is marked in accordance with the CE Marking Directive (//EEC). Standards Complied with: EMI EN 0 Class A EN 000-- Electromagnetic EN 000-- kv / kv Suspectibility EMC EN 000-- kv / kv EN 000-- EN 000-- 0 V/m EN 000-- 0 V ENV 00 0 V/m Company NTI Ltd. Zürich, February, 00 ----------------------------------------------------------- R. Rohner / CEO NTI Ltd. NTI AG Installation: E0/E0/E0 series /.0.00 Page /

Controller Series E0/0/0 Error codes Error display When an error occurs it is displayed by means of the blinking of at least one of the four LEDs on the front of the servo controller. Ready LED The Ready LED is ON as soon as the supply voltage for the processor is guaranteed and the system has started up correctly. Communication with the PC over the serial interface is only possible when this LED is ON. The following table summarizes the blink codes and their meaning: F LED Fault Stat A Stat B l ~ Hz x l ~ Hz off off l ~ Hz Description HW system error: Hardware error in the servo controller. SW System error: Software error in the servo controller. The system software wasn t loaded successfully. SW System error: Software error in the servo controller. The system software wasn t loaded successfully. On l ~ Hz l ~ Hz Generic fault: The exact error message may be displayed with the error inspector. x l x l The supply voltage for the Power circuitry is too low. The supply voltage for the Power circuitry is too high. n x l x l x l x l The supply voltage for the Signal circuitry is too low. The supply voltage for the Signal circuitry is too high. The servo controller is too hot. Application Software Error (see manual) On x l : Mot A x l : Mot B x l : Mot C x l : Mot D x l x l x l x l x l x l x l The motor is overloaded. The motor is too hot. Following error. The slider is missing from the motor. The initialization was not completed successfully. Incorrect motor type configured or damaged motor. A referenced motion profile for a motor is missing. Selected motion profile not valid for actual drive type. on LED is ON off LED is OFF l LED blinks shortly (ca. ¼s) n LED blinks longer (ca. ½s) Contact Addresses NTI AG LinMot Tel. + (0) Haerdlistrasse Fax. + (0) CH- Spreitenbach email: office@linmot.com Schwitzerland Web: www.linmot.com LinMot Inc. N Broad Street Phone +---0 or -- Delavan Fax: +-00--0 or -0-0 WI email: officeus@linmot.com USA Web: www.linmot.com NTI AG Installation: E0/E0/E0 series /.0.00 Page /