Installation Instructions

Similar documents
Installation Instructions

Bluetooth Ceiling Fan Control with App Owner's Manual

LED FOLDING WORKLIGHT TM

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

AutoRanging Digital MultiMeter

Series 803 LED Product Price Display

1 Channel Strobe Controller ORDERCODE 40226

Video Borescope Inspection Camera

User s Guide. 600A AC Clamp Meter. Model 38387

W Remote Control 1

NIMBUS a personal dashboard for your digital life

MP3 Speaker USER GUIDE

STYLISH LED DESK LAMP WITH DIFFERENT LIGHT MODES

DCS200/DCS200-09/DCS DCS300/DCS300-09/DCS355

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

OT EASY 60 II. LED control unit Operating instructions

Cove Light AC HO RGB Graze INSTALLATION GUIDE V0.2. Cover: Cove Light AC HO-9 RGB Graze Cove Light AC HO-36 RGB Graze

User's Guide. MiniTec TM Series Model MN25 MultiMeter

AGRI-COVERTM REMOTE CONTROL INSTRUCTIONS

EPS Power Supply

Party Dimmer IEC ORDERCODE 50324

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

User's Guide. Digital Multimeter. Model MN42

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Antenna Distributor ORDERCODE D1444

True RMS Multimeter with IR Thermometer

Gobo Projector XP 80W

7 Day Digital Programmer 2 Channel Surface Mount

I/O Expansion Box Installation & Operator s Instruction Manual

Universal Remote Controlled Lamp Dimmer User s Manual

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

D-Pack 6 Classic ORDERCODE 50315

RF-Link 2.4GHz Digital Wireless Color Security/Baby Monitor. Model: ABM-4161 User's Manual

Additional Camera Unit for Angelcare Monitors AC-CAM Compatible with models: AC517 - AC510 AC417 AC315 AC310

Remote Control Electrical Roller Blinds

Installation Instructions

Mini Digital Multimeter

Touch Panel Dimmer MH-P511. Introduction

User's Guide. Extech AM A AC Analog Clamp Meter

Mini Digital Multimeter

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Nano Liner Allegro AC XB RGB / DW INSTALLATION GUIDE V1.2

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Mini Digital Multimeter Model MN15. User's Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Digital Overhead Stirrer

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

PF LED Profile. User Manual

LITE TUNES #V

seetouchtm B&O Keypads 15 V 65 ma NEC Class 2; IEC PELV

Wireless Lighting Control. On/Off/Dim. Lamp Module. Z-Wave Certified Wireless Lighting Control

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

Variable-Speed Vortex Mixer

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

Owner s Instruction Manual

MAXIMA+ Series Rotary Level Indicator

Octostrip ORDERCODE 42220

User's Guide. Model High Precision Quad Output DC Power Supply

RoscoLED Tape VariWhite Gaffer Kit

7 Day Programmable Room Thermostat

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Owner s Manual RBC-AX32U(W)-E RBC-AX32U(WS)-E AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit. Model name: English.

Owner's Manual. For latest instructions please go to

Mini Digital Multimeter

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

7 Day Digital Programmer 1 Channel Surface Mount

IP67. Luminux Matrix RGB LED Panel. Luminux Matrix RGB LED Panel - LED Space and Diffuser Distance Guide.

Flexoled FTP3HP RGB LED DMX Driver

Installation and Operations Manual. Electronic copies available at (Rev_ )

Wireless 7 Day Programmable Room Thermostat

TO AVOID FIRE, SHOCK, OR DEATH; SHUT OFF POWER SUPPLY AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING.

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

User Manual. For more information, visit

QuickTouch (QT4) Owner s Manual

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

LED Accu Penta 9x12W RGBWAU

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

POCKET MULTIMETER Model No: MM18

Hardware Operation Manual for CLE1000 H2K CLE1000 H2V

A note about our online installation instructions:

User Guide. Control Box. RoscoLED TM.

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.

ÿ ÿ HA09 - HANDY REMOTE CONTROLLER INSTRUCTIONS

Guest Pager Guest Pager Pro Guest Pager Note

LED Par 64 Short DMX ORDERCODE 42431

Motorized Curtain Tracks Progress 50 Motor Set

Wireless Lighting Control. On/Off. Outdoor Module.

Mini Energy Dimmer MH-P210

Installation Instructions

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

VDLPROM5 SET WITH DMX CONTROL BOX + 4 COLOUR CHANGERS

PORTABLE WIRELESS PA SYSTEM WITH LITHIUM -ION RECHARGEABLE BATTERY AWP6042 OWNER S MANUAL. Handheld Microphone Headset Transmitter

1-36V, 0-3A DC Power Supply

MTP INSTRUCTION MANUAL

Crossfire. User Manual. Order code: EQLED061

ZF LED Zoom Fresnel. User Manual

Vector Beam White. User Manual. Order code: LEDJ265

Transcription:

LUCCI Slim Line Fan Remote Control SKU# 210012 Rated Voltage 220-240V~ 50Hz Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions carefully before using the product. Please keep instructions for future reference. Warranty This light fitting is covered by a 12 month warranty. Please retain proof of purchase and evidence of installation by a licensed electrician. Warranty will be void if there is any damage due to improper usage or modification to the fitting. Installation requirements Must be installed by a licensed electrician. All wiring and installation of the light fitting must adhere to local and national wiring rules. eg. AS/NZS 3000:2007/Amendment 2:2012 Electrical installations. Do not exceed rated power input specification. Select a suitable location for installation; - This product is suitable for indoor use only. This ceiling fan remote controller is only suitable for controlling the fan motor and the light kit associated with the ceiling fan only. Any other use would be considered as misuse and warranty is void. Do not install fan remote control with existing fan wall controller. Remove existing wall controller and replace with a double pole wall switch, to power the fan remote control. Do not use a solid state dimmer with this ceiling fan remote control. Installation directions This remote controller is designed to control your ceiling fan speed and light. There are 4 buttons (HI, MED, LOW, OFF) to control the fan speed and one button to control light on/off. Receiver (controller) Transmitter (remote) 1 P a g e

Before carrying out the installation the following must be considered: - 2 x AAA 1.5V (size) batteries are required to operate the remote control. Remove the battery cover from the back of the remote and insert 2 x AAA. Ensure the polarities are correct as shown in the battery compartment. (Batteries not included) - The remote (transmitter) and receiver must be configured so that communication between each other is paired up. This is achieved by setting the DIP Switch on the receiver and remote on the same setting. Note: The DIP switch assembly has 4 switches which can be setup to 16 different transmitting code combinations. This is practical when there is more than 1 remote/receiver pair operating locally or in the same room. Note: To access the receiver DIP switches, remove the DIP Switch cover. Fig. 1 Remote battery compartment Fig. 2 Receiver DIP switch 2 P a g e

INSTALL THE RECEIVER: WARNING HIGH VOLTAGE BEFORE CONNECTING THE RECEIVER & CHANGE CODES - For your safety: Power to the circuit must be disconnected or switched off. - Household power can cause SERIOUS INJURY or DEATH. - Wiring must meet all local and national electrical wiring codes. MAKING THE ELECTRICAL CONNECTIONS (see Fig. 3) Use the wire nut (terminal block) provided for making connections. 1. Remove/ disconnect electrical power from the working circuit. 2. Remove the ceiling fan CANOPY cover from the mounting bracket. 3. Disconnect existing wiring from the supply at ceiling. 4. Connect the earth (GREEN/YELLOW) wire to the supply EARTH wire, and ensure continuity for the whole electrical earth wiring. 5. Connect AC IN L of control unit to AC L supply wire. 6. Connect AC IN N of control unit to AC N supply wire. 7. Connect TO MOTOR N of control unit wire to the COM (N) fan wire. 8. Connect TO MOTOR L of control unit wire to the MOTOR (L) fan wire. 9. Connect FOR LIGHT of control unit wire to the LIGHT (L1) fan wire. 10. Push the connected wires up into the junction box. 11. Lay the control unit wire on top of the control unit. 12. Lay the control unit in the CANOPY. (See Fig. 4). 13. Reinstall the canopy on the mounting bracket. 14. Restore electrical power to the circuit Fig. 3 3 P a g e

Fig. 4 NOTE: Fan installation must be complete including assembly of blades before operating the remote control. NOTE: This remote control is only suitable where the controller/receiver can be inserted inside the canopy cover safely and securely. Ceiling fan with mount bracket type shown in Fig. 4 would be suitable. NOTE: The controller wiring circuit must NOT be shared with any electrical equipment that is sensitive to voltage fluctuation, such as infrared sensor lights. DO NOT use the wiring of the controller, other than for the purpose of supplying power into the controller and connections to the equipment that is under control. Any outside wiring connections which are not part of the controller/controlled circuit, may affect the operation of the controller and will void warranty. NOTE: The maximum ceiling pitch angle should not be exceeded. It will damage the receiver and result in electric shock. Please check with the retailer about the maximum pitch angle suitable for ceiling fan with remote control. If the remote control device is to be installed with an existing ceiling fan with any of the above wall manual fan controls, PLEASE replace fan wall controller with the double pole ON/OFF switch. Note: A double pole wall switch must be included in the wiring installation. The double pole switch allows the remote controller to disconnect from the mains 240VAC power during maintenance and cleaning of the ceiling fan. 4 P a g e

OPERATING THE REMOTE: ICONS ON THE REMOTE LCD PANEL Before you start using the remote, take the time to read through this section and get familiar with the button and function of each button. Fig. 5 LED Indicator The red LED indicator on the top of transmitter will flash when the buttons are active. BUTTONS ON THE REMOTE HI: Press the button to set fan running at High speed. MED: Press the button to set fan running at Medium speed. LOW: Press the button to set fan running at Low speed. OFF: Press the button to turn OFF the fan. : Press the button to turn ON/OFF the light. The remote has memory function. If the fan or light is turned off by the wall switch, it will memorise and recover the last status when turned on next. 5 P a g e

TROUBLE SHOOTING: Warning: For your safety, ensure the power is switched OFF before starting the troubleshooting procedures TROUBLE PROBABLE CAUSES SUGGESTED REMEDY 1.No functions operate. Warning: Some tasks can only to be performed by a qualified technician. Main power not restored. Wall switch power to the fan remote is OFF. Receiver wiring incorrect. Transmitter and receiver DIP switches do not match. The remote is too far from the receiver. Battery too weak. Batteries at wrong polarity. Replace fuse. Turn ON circuit breaker. Turn ON wall switch. Switch wall switch ON, to power the remote. Verify wiring connections according to label and wiring diagram. Set transmitter and receiver to same DIP switch setting. Move closer to receiver. Replace with all new batteries. Do not mix the old and new batteries. Reinstall the batteries at right polarity. 2. Remote LED/LCD no display. 3. Operates only at close range. 4. More than one fan operates interference at same area. The contacts in battery compartment are corroded or bent. Poor contact with batteries. Signal blocked from reaching receiver. Batteries too weak. RF interference. Clean corroded contacts. Bend contacts back to their correct position. Roll the batteries to get them to sit in the compartment, or replace with other brand batteries. Extend antenna in canopy, or move it for better reception. Replace with all new batteries. Do not mix the old and new batteries. Change DIP switch settings to a different code. Each pair of transmitter and receiver must have unique DIP switch code. 6 P a g e

Safety tips Always ensure the power is OFF and the fitting has cooled down before performing any maintenance, cleaning, changing the globe or adjustment to the fitting. Do not touch the globe with bare hands. Use a clean cloth, gloves or a tissue. To avoid injury or damage to the fitting, ensure that power leads and screws are secure before connecting the power. Select a suitable location away from liquids and hazards. Ensure that the fitting does not come in contact with corrosive chemicals, etc. To clean, wipe with a damp clean cloth. Never soak the fitting with water. Specifications Transmitter (Remote): Receiver (Controller): SKU # 210012 Model # UC7216T Model # UC7076RY Rated Voltage 2 X 1.5V AAA battery Rated Voltage 230-240VAC 50/60Hz Frequency 433.92MHz NON-DIMMING Operating range approx. 20-30 feet. Max. Motor load 0.5A, Ceiling Fan Only Max. Incandescent/Halogen load 300W Max. Fluorescent lamp & ballast load 100VA Max. LED driver load 100VA WARRANTY & SERVICE STATEMENT Lucci Design warrants all of its products against defective workmanship and faulty materials for 12 months from the date of purchase and in addition to any warranties or conditions implied by applicable Statue or Regulation. Lucci Design undertakes, at its option, to repair or replace, free of charge, each product or part thereof on condition that; 1. The product or relevant part has not been subjected to misuse, neglect, or been involved in an accident. 2. The repairs are not required as a result of normal wear and tear. 3. Evidence that the product was installed by a licensed electrical contractor. 4. A copy of the original receipt of purchase is presented. In the event of service being required, please contact your local Beacon Lighting Store or call the Lucci Warranty Hotline on 1800 602 243 between 9am & 5pm (EST) Monday to Friday. Please make sure you have a copy of the original receipt of purchase and evidence that the product was installed by a licensed electrical contractor manual before making the call. Lucci Design cannot be held responsible for any repair other than those carried out by it or one of its Authorised Service Agents. Please keep this warranty information in a safe place. This information must be produced in the event of service being required. READ AND STORE THESE INSTRUCTIONS FOR FUTURE REFERENCE 7 P a g e