Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

Similar documents
Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

DC-AC Inverter Pure Sine Wave 120 Watt. Please read this manual before installing your Inverter. Manual PST

Pure Sinewave Inverter

N+1 DC Power System with Battery Backup / Charging Function

2010 Power Conversion Products

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

Power Rack 58. EXT-PS5-8R User Manual.

TB-100 ControLynx Terminal Block

Transfer Switch 30 Amps STS-30. Owner's Manual. Please read this manual BEFORE operating your transfer switch

MULTIPLEXER MX4. Operation and Installation Manual. Pacific Micro Systems

Model 3526-B Digi-Probe Multimeter

TDM-170 TIMER DISPLAY

FNet Repeater Installation & Operator s Instruction Manual

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

ipad Charge & Sync Cart Model MCC2 ipad Cart 430-MCC2-User Manual-010 Is a Registered Trademark of Apple Inc. ipad

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1


USB Ranger 110/410 User Guide

AWS-QC Torque Tester

TDM-150 TIMER DISPLAY

CA-A480-A Elevator Controller. Reference & Installation Manual

MTS-2000 USER S MANUAL

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

BLUETOOTH SPEAKER. for ipod/iphone/ipad/android. User s Manual. Item #TA-11BTSP. PC Mac Ultrabook COMPATIBLE BLUETOOTH WIRELESS USB

INSTRUCTION MANUAL A START-UP AND SHUT DOWN LOAD SEQUENCER AND AUTOMATIC LOAD SHEDDING SYSTEM WITH INTEGRAL RELAYS FOR 8 LOADS MODEL #091-60A

AirPro Surveyor 2 Manual

User s Manual Legend SB425 K

Owner s Instruction Manual

XC4100 INSTALLATION/OWNER'S MANUAL AM/FM/Cassette Receiver

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

USB Ranger 422 User Guide

FES LCD Display Version 1.1

TELink FLASH. Model 700a. Installation and Operation Instructions. Magic On Hold is a Registered Service Mark and Trademark of Avaya Communications

Woolich Racing. USB ECU Interface User Guide

I/O Expansion Box Installation & Operator s Instruction Manual

B/W PAN/TILT FIXED DOME CAMERA

USB 2.0 LR 4-Port Extender

CONTENTS CONTENTS AWS-4050 Guide

Page/Talk Industrial Desk Sets

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

S82S (3/7.5-W Models)

90130, 90131, POP DISPLAY ASSEMBLY INSTRUCTIONS

MFJ ENTERPRISES, INC.

PSA200 User s Manual

EAS DIGITAL/ANALOG OVERRIDE INTERFACE Model 988 PC Software version 1.06

AIRLIFT S3 Electric Height-Adjustable Standing Desk USER MANUAL

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

Wireless Doorphone Intercom

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

OPERATIONS MANUAL PCM-I/O48

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

VIP-812A DUAL NETWORKED STATION PORT

Checking the Package Contents

MiniSim 330 EEG Simulator

Start Here. All-in-One Printer. Print Copy Scan

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Checking the Package Contents

V-9908 MESSAGE/PAGE PANEL

FTC-200 X-ray Tube Controller Users Manual

To purchase additional handsets (DCX640), visit our web site at

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-300

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

PS8 - II. Professional Power Sequencer. User s Manual

EPSON PreferredSM Limited Warranty Program for the Epson Stylus

Trimble S6 and SPS700 Total Station Firmware

8-Bit Temperature Smart Sensor (Part # S-TMA-M0XX)

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual

zpen-1080p Features zpen-1080p Layout

AWS-3000 Torque Display

WR-5e Remote Control

1:4 DVI Splitter EXT-DVI-144N

Digital Lighting Systems, Inc.

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

User Guide. Control Box. RoscoLED TM.

Relay Board. User Manual. 1.0, Oct 2013

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

MIR-K16S-2101Q IR Distribution Kit with 6 Ports

USB 3.0 Spectra

XC300 VDSL Network Extender Owners Manual

Chroma-Q Color Web PSU 10-DMX. User Manual

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

DVI ELR Extender over one CAT5

V-9964 Digital Feedback Eliminator/Message Stacker

EPSON Preferred. Priority Technical Support. Toll-Free Phone Number. Security and Peace of Mind. On-Site Repair

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

E-BEAM SWEEP NILES ELECTRONICS

AC4G-D User s Manual

VIP-480AL IP One-Way Horn

DCM Digital Control Modules

HUBBCOM GSC3000/GSC4000 Flush-Mount Smart Controller Quick Installation Guide

Enable-IT 821 Ethernet Extender Quickstart Guide Professional Grade Networking

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

PMDX-170 Slotted Optical Sensor

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

2x Dual Link DVIKVM Extender Over CAT-6a

Transcription:

Remote Control for Inverter RC-300 Owner's Manual Please read this manual BEFORE operating your RC-300 Remote Control

OWNER'S MANUAL Index SECTION 1 Safety...3 SECTION 2 Description...3 SECTION 3 Layout of Controls, Indications & Dimensional Drawings... 3 SECTION 4 Installation...6 SECTION 5 Operation...6 SECTION 6 Specifications...7 SECTION 7 Warranty...8 2 SAMLEX AMERICA INC.

SECTION 1: SAFETY 1.1 Before using this Remote Control, please follow the Safety Instructions given in the Owner s Manual for the inverter PST-3000-12 / PST-3000-24. SECTION 2 DESCRIPTION 2.1 RC-300 is a wired Remote Control that is compatible with inverter model numbers PST-3000-12 and PST-3000-24. 2.3 It is used to switch ON and switch OFF the inverter from a remote location. It also displays the operational status using LCD display and colored LEDs. It is provided with 25 ft / 7.62 meters of connecting cable set with RJ-50 Modular Plugs (10P10C). The conductors of the cable set have crossed-over (rolled-over) connections on the two RJ-50 plugs. SECTION 3 LAYOUT OF CONTROLS, INDICATIONS & DIMENSIONAL DRAWING 3.1 Fig. 1 (page 4) shows the layout of controls and indications and dimensional drawing. 3.2 ON/OFF Control ON/OFF Push Button (1) is used to switch ON and switch OFF the inverter. Every time the ON/OFF Push Button is pressed, a beep will be heard. This Remote Control will operate only after the inverter PST-3000 has been first turned ON using the local ON/OFF Switch on the inverter or using external ON/OFF control provided in the inverter. Read under heading "Optional Wired Remote Control - Model RC 300" in Section 8 of Owner's Manual for PST-3000. 3.3 LCD Display LCD screen (3) is used to display the following 6 output parameters in a sequential loop as given below. The screen changes to show the successive parameter in a sequential manner every time the Display Push Button (2) is pressed (Sequence is: Screen1-2-3-4-5-6-1-2-3 ) 1. AC output voltage in Volts, V 2. AC output current in Amps, A 3. AC output frequency in Hertz, Hz 4. Active AC output power in Watts, W - The display is limited to a range of 6W - 3500W 5. Apparent Output Power in Volt Amps, VA 6. Power Factor, PF SAMLEX AMERICA INC. 3

When the inverter is switched ON using the ON/OFF Push Button (1), the LCD screen displays information as follows: It takes 2 to 6 sec for booting / initialization. During this time, all the above 6 parameters will be displayed as 0 If the load is > 6W, all the above 6 parameters will be available for display after end of booting / initialization period If the AC output power is less than 6W, parameters AC output current in A, Active AC output power in Watts, W, Apparent Output AC Power in Volt Amps, VA and Power Factor, PF will not be displayed (will be displayed as 0 ). This is necessary because at power output < 6W, the noise on the output side may be comparable to the low value of the load and the logic may not be able to differentiate noise from load and hence, may display wrong values for these parameters 3.4 Power Saving / Sleep Mode in the LCD Display To save power, the LCD display will remain ON for 3 minutes from the time the Display Push Button (2) is pressed and will then switch OFF into Sleep Mode. To wake up, press the Display Push Button (2). 65 3 DISPLAY 2 LEGEND 1. Power ON/OFF Push Button 2. Push Button to Change Display Screen 3. LCD Screen 4. LED - Overload 5. LED - Over Temp 6. LED - Power 7. RJ-50 Modular Jack 4 OVER LOAD OVER TEMP POWER 1 Note: All dimensions in mm Pure Sine Wave MODEL RC-300 5 6 Front View 110 Overall Depth: 25.5 8,5 1 32,5 4 R2 R2 4 32,5 48 32,5 7 32,5 8,5 98 15 80 15 Back View Fig. 1 Remote Control RC-300 - Layout and Dimensional Drawing 4 SAMLEX AMERICA INC.

3.5 LED Display The following LED displays are available: Green LED (6) marked POWER. This LED will be lighted when the inverter is in ON condition. When the inverter is in OFF condition, this LED will not be lighted. This LED shows that DC input is available to the inverter and that the input section of the inverter is operating normally Red LED (4) marked OVER LOAD. When lighted, it indicates that the AC output of the inverter has been shut down due to over load Red LED (5) marked OVER TEMP. When lighted, it indicates that the AC output of the inverter has been shut down due to over temperature 3.6 Pinout of RJ-50 Modular Jack The pinout of the RJ-50 Modular Jack (7) at the back of the RC-300 is given at Fig. 2 below: 1 2 3 4 5 6 7 8 9 10 Fig. 2 Remote Control RC-300 - Pinout of Modular Jack RJ-50 The standard numbering system of the pins of a Modular Jack, when looking into the Jack, is from left to right. As the conductors of the cable are cross-connected (rolled-over), the pinouts at the Modular Jack in the inverter will be a mirror image of the pinout of the Modular Jack in the Remote Control as shown in Table 1 below: Pinout of Modular Jack on the Remote Control as per Fig 2 (1) TABLE 1 PIN OUT FOR MODULAR JACKS Signal (2) Pinout of Modular Jack on the inverter (See Note 1) (3) 1 LED "OVER TEMP" 10 2 LED "POWER ON" 9 3 Avcc 8 4 GND 7 5 TOGGLE 6 6 LED - OVERLOAD" 5 7 Vcc 4 8 LCD - Data (B) 3 9 LCD - Data (A) 2 10 LCD - Ground 1 Note for Table 1: 1. Pin Nos of the Jack on the inverter (Column 3) are mirror image of Pin Nos on the Jack in the Remote (Column 1) due to crossed-over / rolled over connection of conductors. SAMLEX AMERICA INC. 5

SECTION 4 INSTALLATION 4.1 Please refer to Fig. 1. The Remote Control can be flush mounted on a wall or a panel by making a suitable cut-out to accommodate the projection in the back. 4.2 Please ensure that the inverter PST-3000-12 / PST-3000-24 is switched OFF before connecting RC-300 to the inverter. 4.3 Connect one end of the cable set to the RJ-50 Modular Jack (7) at the back and the Remote and the other end to the RJ-50 Modular Jack on the inverter. Ensure that the connection is firm and the tab on the plug securely locks in the jack. SECTION 5 OPERATION NOTE: This Remote Control will operate only after the inverter PST-3000-12 / PST-3000-24 has been first switched ON using the local ON/OFF Switch on the inverter or using the external ON/OFF control provided on the inverter (for details, please refer to Section 8 of Owner's Manual for PST-3000-12 / PST-3000-24 under heading "Optional Wired Remote Control - Model RC-300). 5.1 Switch ON PST-3000-12 / PST-3000-24 using the local ON/OFF Switch on the inverter or using external ON/OFF control provided on the inverter (for details, please refer to Section 8 of Owner's Manual for PST-3000-12 / PST-3000-24 under heading "Optional Wired Remote Control - Model RC-300). Once the inverter turns ON, the operational status of the inverter will be displayed through the LCD screen (3, Fig 1) and LEDs (4, 5, 6; Fig 1). 5.2 See under headings LCD Display (Section 3.3 and 3.4) and LED Display (Section 3.5) for information on the operating conditions. Please read Section 11 - "Troubleshooting Guide" of the Owner's Manual for PST-3000-12 / PST-3000-24 for identifying abnormal conditions indicated by the LEDs. 5.3 The output of the inverter can be switched ON/OFF using the ON/OFF Push Button (1, Fig 1). 5.4 No Load Current Draw As stated above, the ON/OFF Switch on the inverter is required to be in ON condition for the Remote to operate. When the ON/OFF switch on the Remote Control is turned ON, all the circuitry inside the inverter becomes fully alive and the AC output is made available. In this condition, even when no load is being supplied (or, if a load is connected but has been switched OFF), the inverter draws a small amount of current from the batteries to keep the circuitry alive and is ready to deliver the required power on demand. This is called the idle 6 SAMLEX AMERICA INC.

current or the no load current draw. When the inverter is turned OFF using this Remote Control, some control circuitry is still alive in the inverter and will require very small current draw. Hence, when the load is not required to be operated, turn OFF the ON/OFF Switch on the inverter to prevent unnecessary current drain from the battery. SECTION 6 SPECIFICATIONS MODEL NUMBERS OF COMPATIBLE INVERTERS CABLE SET PST-3000-12 PST-3000-24 RJ-50 (10P10C) with crossed-over / rolled-over connections. Length = 25 ft / 7.62 meters OPERATING TEMPERATURE RANGE 0 to 40 C / 32 F to 104 F DIMENSIONS (L X W X D) Weight (Without cable / with cable) 110 x 65 x 24.7 mm / 4.33 x 2.56 x 0.97 in 85 gm / 256 gm; 0.04 lb / 0.12 lb NOTE: Specifications are subject to change without notice SAMLEX AMERICA INC. 7

SECTION 7 WARRANTY 2 YEAR LIMITED WARRANTY RC-300 Remote Control manufactured by Samlex America, Inc. (the Warrantor ) is warranted to be free from defects in workmanship and materials under normal use and service. The warranty period is 2 years for the United States and Canada, and is in effect from the date of purchase by the user (the Purchaser ). Warranty outside of the United States and Canada is limited to 6 months. For a warranty claim, the Purchaser should contact the place of purchase to obtain a Return Authorization Number. The defective part or unit should be returned at the Purchaser s expense to the authorized location. A written statement describing the nature of the defect, the date of purchase, the place of purchase, and the Purchaser s name, address and telephone number should also be included. If upon the Warrantor s examination, the defect proves to be the result of defective material or workmanship, the equipment will be repaired or replaced at the Warrantor s option without charge, and returned to the Purchaser at the Warrantor s expense. (Contiguous US and Canada only) No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so. Warranty service shall be performed only by the Warrantor. Any attempt to remedy the defect by anyone other than the Warrantor shall render this warranty void. There shall be no warranty for defects or damages caused by faulty installation or hook-up, abuse or misuse of the equipment including exposure to excessive heat, salt or fresh water spray, or water immersion. No other express warranty is hereby given and there are no warranties which extend beyond those described herein. This warranty is expressly in lieu of any other expressed or implied warranties, including any implied warranty of merchantability, fitness for the ordinary purposes for which such goods are used, or fitness for a particular purpose, or any other obligations on the part of the Warrantor or its employees and representatives. There shall be no responsibility or liability whatsoever on the part of the Warrantor or its employees and representatives for injury to any persons, or damage to person or persons, or damage to property, or loss of income or profit, or any other consequential or resulting damage which may be claimed to have been incurred through the use or sale of the equipment, including any possible failure of malfunction of the equipment, or part thereof. The Warrantor assumes no liability for incidental or consequential damages of any kind. Samlex America Inc. (the Warrantor ) www.samlexamerica.com 8 SAMLEX AMERICA INC.

NOTES: SAMLEX AMERICA INC. 9

NOTES: 10 SAMLEX AMERICA INC.

NOTES: SAMLEX AMERICA INC. 11

Contact Information Toll Free Numbers Ph: 800 561 5885 Fax: 888 814 5210 Local Numbers Ph: 604 525 3836 Fax: 604 525 5221 Website www.samlexamerica.com USA Shipping Warehouse Kent WA Canadian Shipping Warehouse Delta BC Email purchase orders to orders@samlexamerica.com 11001-RC-300-1015