Specifications, Installation, and Operating Instructions

Similar documents
Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

BSPD Surge Protective Devices

Total Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

Surge Protective Devices. STV25K Series. Instruction Manual

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

ZoneMaster Series Surge Protection Devices

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

GE Digital Energy. Power Quality

Installation and Operation Manual

Installation Instructions & User Manual

Surge Protective Devices Installation, Operation and Maintenance Manual. ServiceTrack ST Series: 080, 120, 160, 200, 240, 300 and 400

SECTION SURGE PROTECTIVE DEVICES

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

R-LB R-LX Series Installation, Operation & Maintenance Manual

Westell. Breaker Panel Technical Practice NPDRP1114

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Breaker Panel Technical Practice NPDRP1114

PDI Modular Compact Remote Power Panel

Eaton s SPD Series for integration into electrical distribution equipment

Always "On" UPS Systems Inc. USER MANUAL

Hubbell Surge Protective DeviceS

Instruction Manual IM E Table of Contents

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

TransGuard. Electrical Transient Suppression Filter Systems. Installation, Operation and Maintenance Manual PN ,

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

Powerware TVSS (Transient Voltage Surge Suppression) ZoneMaster, ZoneSentinel, ZoneDefender

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

Surge Protection Devices (SPD)

Series Amp Pad Mount Quick Connect Input and Output Power Panels

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Installation and Operation Manual

Protect your facility from the destructive effects of power surges with a fully

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

SECTION TRANSIENT VOLTAGE SURGE SUPPRESSION

Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors

Instruction Bulletin Boletín de instrucciones Directives d'utilisation , Rev. 02, 03/2016

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Expandable Power Systems

Technical Data Sheet Medium Current Power Surge Filters

Internal Modular SPDs

RTD SAMPLER OPERATOR S MANUAL

S66 Series Electronic Fan Speed Control

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

File E Project 05NK Issued: Revised: REPORT CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD)

Line Impedance Stabilization Network (LISN)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

Installation Instructions

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

GE TR7000 Series Wall Mounted Surge Protective Device (SPD)

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

LPI SST Surge Filters

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Surge Protective Devices. Installation & Operation Manual. NEMA 12 (Steel) NEMA 1 (Non-Metallic) Model 350

DAW 8/28/09. TITLE Specification I2R 120/240 RR 120V AC Split Phase Surge Protector PAGE 1 of 9 REVISIONS

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

SOUTH CAROLINA ELECTRIC COOPERATIVES SECONDARY TYPE 1 SURGE PROTECTIVE DEVICE SPECIFICATIONS Updated/Revised: October 6, 2014

MIL STD 220a (50 Ohm) Model Ordering: 400LS - 277Y - DS - UFP - MX

Back-UPS RS APC Back-UPS RS 800VA 120V Black

INSTALLATION INSTRUCTIONS

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

GUIDE TO VERIFYING SURGE PROTECTIVE DEVICES INSTALLED IN LIGHTNING PROTECTION SYSTEM INSTALLATIONS ARE COMPLIANT WITH UL 96A.

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual

Broadband Automatic Disconnect Switch. User Manual

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

INSTALLATION INSTRUCTIONS

User Manual - Canada. TPS3 03 DC For DC Photovoltaic Applications. Surge Protective Device

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA

User Manual Back-UPS BE650MC

Surgelogic Surge Protective Device I-Line Plug-On Unit Series

SAVE THESE INSTRUCTIONS

for the SPV Installation and Operation Manual Instruction Manual IM E Contents

B. System Design and Performance Requirements

TPS3 09. Surge Protective Device. User Manual - USA

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

PV Rapid Shutdown device

File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)

SSMx24 Series 240 ka Per Phase Peak Surge Current ANSI/UL1449 UL Fourth Edition

2.1. SPD, Power Conditioning, PF Capacitors and Harmonic Filters. Contents Description. Introduction. Surge Protection and Power Conditioning

ORB TM 4-20 ma Input Box Installation & Operation Manual

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

B60 Domestic Voltage Optimisation Unit. Installation Manual

Quick Start Guide TS A

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

Transcription:

Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel. A must be grounded through the power system ground for proper operation. WARNING: Before installing the suppressor, AC power must be OFF. Failure to do so could result in damage to the suppressor and poses a potential electrical shock hazard to personnel. WARNING: Read label on side of the enclosure to verify voltage configuration. WARNING: Discontinue installation if the measured voltage is not in the range of the model voltage configuration of the being installed. Contact LEA International technical support with any questions concerning the voltage configuration prior to installation and application of power. 1

Contents: TITLE PAGE Specifications 3 Pre-Installation Notes 5 Mechanical Installation 5 Electrical Installation 6 Installation Procedure Checklist 8 Troubleshooting 8 Module Replacement Procedure 9 Wiring Diagrams 9 Warranty 13 Part Number Model: Type II Description Fig. Ref. B93-00-2040 PV-200-120/240-SP, MOV 200 ka, 120/240 Vac, SP 1 B94-00-2040 PV-200-120/240-SP-D, MOV 200 ka, 120/240 Vac, SP, Disconnect Switch 1 B93-00-4040 PV-400-120/240-SP, MOV 400 ka, 120/240 Vac, SP 1 B94-00-4040 PV 400-120/240-SP-D, MOV 400 ka, 120/240 Vac, SP, Disconnect Switch 1 B93-00-6040 PV-600-120/240-SP, MOV 600 ka, 120/240 Vac, SP 1 B94-00-6040 PV-600-120/240-SP-D, MOV 600 ka, 120/240 Vac, SP, Disconnect Switch 1 B93-00-2140 PV-200-120/208-3Y, MOV 200 ka, 120/208 Vac, 3Y 2 B94-00-2140 PV-200-120/208-3Y-D, MOV 200 ka, 120/208 Vac, 3Y, Disconnect Switch 2 B93-00-2740 PV-200-277/480-3Y, MOV 200 ka, 277/480 Vac, 3Y 2 B94-00-2740 PV-200-277/480-3Y-D, MOV 200 ka, 277/480 Vac, 3Y, Disconnect Switch 2 B93-00-4140 PV-400-120/208-3Y, MOV 400 ka, 120/208 Vac, 3Y 2 B94-00-4140 PV-400-120/208-3Y-D, MOV 400 ka, 120/208 Vac, 3Y, Disconnect Switch 2 B93-00-4740 PV-400-277/480-3Y, MOV 400 ka, 277/480 Vac, 3Y 2 B94-00-4740 PV-400-277/480-3Y-D, MOV 400 ka, 277/480 Vac, 3Y, Disconnect Switch 2 B93-00-6140 PV-600-120/208-3Y, MOV 600 ka, 120/208 Vac, 3Y 2 B94-00-6140 PV-600-120/208-3Y-D, MOV 600 ka, 120/208 Vac, 3Y, Disconnect Switch 2 B93-00-6740 PV-600-277/480-3Y, MOV 600 ka, 277/480 Vac, 3Y 2 B94-00-6740 PV 600-277/480-3Y-D, MOV 600 ka, 277/480 Vac, 3Y, Disconnect Switch 2 B93-00-2830 PV-200-480-3D, MOV 200 ka, 480 Vac, 3D 3 B94-00-2830 PV-200-480-3D-D, MOV 200 ka, 480 Vac, 3D, Disconnect Switch 3 B93-00-4830 PV-400-480-3D, MOV 400 ka, 480 Vac, 3D 3 B94-00-4830 PV 400-480-3D-D, MOV 400 ka, 480 Vac, 3D, Disconnect Switch 3 B93-00-6830 PV-600-480-3D, MOV 600 ka, 480 Vac, 3D 3 B94-00-6830 PV 600-480-3D-D, MOV 600 ka, 480 Vac, 3D, Disconnect Switch 3 2

Part Number Model: Type I Description B93-00-2141 PV-200-120/208-3Y-1 Type 1, MOV 200 ka, 120/208 Vac, 3Y 2 B94-00-2141 PV-200-120/208-3Y-1-D Type 1, MOV 200 ka, 120/208 Vac, 3Y, Disconnect Switch 2 B93-00-2741 PV-200-277/480-3Y-1 Type 1, MOV 200 ka, 277/480 Vac, 3Y 2 B94-00-2741 PV-200-277/480-3Y-1-D Type 1, MOV 200 ka, 277/480 Vac, 3Y, Disconnect Switch 2 B93-00-4141 PV-400-120/208-3Y-1 Type 1, MOV 400 ka, 120/208 Vac, 3Y 2 B93-00-4741 PV-400 277/480-3Y-1 Type 1, MOV 400 ka, 277/480 Vac, 3Y 2 B94-00-4741 PV-400 277/480-3Y-1-D Type 1, MOV 400 ka, 277/480 Vac, 3Y, Disconnect Switch 2 B93-00-6741 PV-600-277/480-3Y-1 Type 1, MOV 600 ka, 277/480 Vac, 3Y 2 Fig. Ref. Specifications All Models Features Protection Provided Maximum Surge Current Dissipation per Phase* Nominal Discharge Current (In) Operating Frequency Response Time Operating Temperature Range Thermally Protected MOV Alarm with Disable Switch Internal/External Indicators Lights Surge Counter Form C contacts (NO & NC) EMI/RFI Noise Filtering ; ; ; 200 ka PV 200 400 ka PV 400 600 ka PV 600 20 ka 47-63 Hz <1 nanosecond -40 C to +65 C Operating Humidity (noncondensing) 95% Enclosure Dimensions H x W x D Weight (Max) lb, kg Certifications *8 x 20 µsec current wave per ANSI/IEEE C62.41 NEMA 3R 24.0 x 16.0 x 8.9 61.0cm x 41.0cm x 22.4 cm 60 lbs. / 27 kg. UL 1449 3 rd Edition Listed (E315238) 3

Model PV-200-120/240-SP PV-400-120/240-SP PV-600-120/240-SP Product Type V (Vac) Phase 120/240 1 Mode(s) @ VPR (Vpk) 1200 1200 In MCOV 20 ka 127/254 PV-200-120/240-SP-D PV-600-120/240-SP-D PV-400-120/240-SP-D 120/240 1 20 ka 127/220 PV-200-120/208-3Y PV-400-120/208-3Y PV-600-120/208-3Y 120/208 3Y 1200 1200 20 ka 127/254 PV-200-120/208-3Y-D PV-400-120/208-3Y-D PV-600-120/208-3Y-D 120/208 3Y 20 ka 127/220 PV-200-277/480-3Y PV-400-277/480-3Y PV-600-277/480-3Y 277/480 3Y 1800 1800 1800 20 ka 293/508 PV-200-277/480-3Y-D PV-400-277/480-3Y-D PV-600-277/480-3Y-D 277/480 3Y 1800 1800 1800 20 ka 293/508 PV-200-480-3D PV-400-480-3D PV-600-480-3D 480 3D 20 ka 593/508 PV-200-480-3D-D PV-400-480-3D-D PV-600-480-3D-D 480 3D 20 ka 593/508 PV-200-120/208-3Y-1 Type 1 120/208 3Y 1000 1000 1200 20 ka 138/239 PV-200-120/208-3Y-1-D PV-400-120/208-3Y-1-D Type 1 120/208 3Y 1000 1000 1200 20 ka 138/239 PV-200-277/480-3Y-1 PV-400-277/480-3Y-1 Type 1 277/480 3Y 20 ka 319/552 PV-200-277/480-3Y-1-D PV-400-277/480-3Y-1-D PV-600-277/480-3Y-1-D Type 1 277/480 3Y 20 ka 319/552 4

PRE-INSTALLATION NOTES Please read the entire installation manual before installing this. Unpack unit carefully, removing packing material. Inspect for damages during shipment. If unit seems damaged, contact LEA International. Do not continue to install unit. Verify that all nuts, bolts and terminal blocks have good tight connections with clean electrical contact area. Every connection should be checked, not just the input terminal blocks. This will ensure the lowest possible contact resistance and best performance. Electrical Specification for Installation: Verify the voltage configuration of the matches actual system voltage configuration of service point. Ground resistance is less than 25 ohms. Make sure all conductors are appropriate for this. MECHANICAL INSTALLATION 5

ELECTRICAL INSTALLATION Routing of Connection Leads The should be mounted as close as possible to the connection of service point and routed with gradual bends avoiding sharp bends or 90 bends. Length of Leads Leads must be as short as possible, not exceeding the recommended length of five feet (5 ). Conduit of sufficient size per NFPA 70, National Electrical Code, is intended to enter at the top or on either side near the top of enclosure. Mounting The is installed in parallel with the incoming phase conductors. The is mounted using the four corner holes in the enclosure. Each hole is ½ in diameter. The mounting holes of the enclosure have a distance in length (from top to bottom) of 22.5 and a distance in width (from left to right) of 14.5. 6

Phase Connection and Conductor Size The wire size for the phase conductors should be #14-1/0 AWG. Use of #6 AWG copper minimum is recommended. Connect the phase input wires to the terminals marked Phase 1, Phase 2, or Phase 3 input. It is recommended to connect the to a 60A circuit breaker. This will help when servicing the or replacing modules. An integral switch disconnect may be used; and is ordered as an option. Utilize PVC or aluminum (non-metallic, non-ferrous) conduit with no sharp bends and with a minimum spacing of 4 from the other conductors. Neutral Connection and Conductor Size The wire size for the neutral conductor should be #8 to 1/0 AWG. #6 AWG is recommended. The neutral point wire shall be run in the same conduit as the power-input wires and safety ground wires. Ground Connections and Conductor Size The provides two types of ground, the safety ground and the transient ground. The safety ground The wire size for the safety ground conductor should be #8 AWG to 1/0 wire, #6 AWG is recommended. Connect the safety ground lug to the existing building safety ground system. This is to equalize back panel potential only. No other connections are made to this lug inside the. The transient ground The wire size for the transient ground conductor should be #8 AWG to #1/0 AWG wire, #6 AWG is recommended. This connection should be made from the transient ground lug to common point earth ground or building steel if it is tied into the facility ground conductor. If a separate ground is driven for the transient ground, it must be tied into the existing ground system. Final Check Apply external AC power to the. The is now operational. All LED(s) should be illuminated green. If not, contact LEA International s technical support at 800-882-9110. Visual Inspection Operational status of the is verified by observing the status indicator LED(s). Phase A, B, and C status LED ON indicate phase input power is applied. The LED(s) illuminated green indicates normal operation with all protection modes functioning. The TVSS status LED illuminated red indicates a failure within the ; please call technical support. To determine if a specific surge module has suffered failure, observe the LED indicators on the PCB Mother board with power applied. A failed module will illuminate red on the mother board. External Indication Lights- shows loss of power and protection integrity. Internal Protection Indicator Lights of Modules- redundant monitoring to identify damaged modules for easy servicing. 7

INSTALLATION PROCEDURE CHECKLIST: YES NO The voltage configuration of the matches actual voltage configuration of service point. Ground resistance is less than 25 ohms. All wiring conforms to the national electric code (NEC). All conductors are in accordance with the appropriate layout All lead lengths are as short as possible. The is installed in parallel with the incoming phase conductors. A After installation, all lights are illuminated green. All critical loads are protected by the. If not, additional (s) may be required. TROUBLESHOOTING Problem Alarm disabled LED is red right after installation Solution Press the Audible Alarm enable button, it should turn off the red alarm disable LED. Alarm sound is audible Silence alarm by using disable button; otherwise use the circuit breaker to disconnect power and silence the alarm. This indicates there was an event which requires checking/replacing inside modules. Surge counter display is blank The battery may be defective or dead. Please contact LEA Technical support. Status LED is illuminated red Disclaimer: Maintenance of electrical devices should be done by trained personnel. Open enclosure door of, reconnect power, and check internal status indication LED(s). At the right side of the set of modules per phase, there are status indication LEDs corresponding to the modules per phase; please investigate if they are illuminated red or if they are off. Disconnect power after LED inspection. 8

Internal Status indication LED(s) is red This indicates module needs replacement; turn off the circuit breaker or disconnect switch (reference procedures on pg. 8) or call LEA technical support to check warranty. Internal Status indication LED(s) are off This indicates the modules are working properly. If the Status in front door is red, then call LEA Technical support. Power On Phase(s) LED(s) not illuminated This indicates a loss of power. Please verify power is being supplied to service point; if problem persist, call LEA technical support. LEA Technical Support is available at 800-882-9110. MODULE REPLACEMENT PROCEDURE Disclaimer: Maintenance of electrical devices should be done by trained personnel. Warning: Before attempting to perform module replacement, POWER MUST BE TURNED OFF to the. Failure to do so could result in damage to the or result in electrical shock. Keep hands and clothing clear of energized conductors to reduce the possibilty of electrical shock. 1. Identify the modules that need to be replaced. Verify that the replacement, modules are for the same type and rating as the ones requiring replacement before proceeding. 2. Remove input power to the. 3. Remove all mounting hardware and retain for use with the replacement module. 4. Remove the defective module and exchange with the replacement module. Re-verify that the replacement module is of the same type and rating as the one being replaced. 5. Secure replacement module with the mounting hardware removed from the defective module. 6. Reapply input power to. All modules status indicators and enclosure door indicators should illuminate when power is applied. Spare modules can be ordered from the factory as an option to the original purchases or at a later date. Modules are usually available within 24 hours. Wiring Diagrams: 9

The following section contains all layout/installation drawings found within the Power Vantage Family. Locate the appropriate drawing based on the model number of your system. 10

11

12

13

Material Return Policy No product may be returned without LEA(s) written approval. Transportation charges are to be prepaid by the buyer. Returned item(s) are subject to LEA(s) inspection and acceptance. LEA may, at its discretion, replace any or all return items within a reasonable time after LEA determines that returned item(s) are not in accordance here within; and in such an event, LEA shall not be reliable for any damage arising from the defective delivery or delay caused thereby. When authorized by LEA in writing, unused products may be returned to LEA, subject to service handling, restocking, and if necessary rebuilding charges to as new condition. Call LEA International s customer service department at 800.882.9110 for a return material authorization (RMA) number. No items will be accepted without a RMA number. Please have the following information on hand when calling for an RMA number: MODEL NUMBER FAILURE DESCRIPTION PART NUMBER INSTALLATION DATE PURCHASED DATE SYSTEM OPERATING VOLTAGE LEA JOB NUMBER 14