Ver. 2.0en 1550nm CATV Erbium Doped Fiber Amplifier EDFA-4429 Series USER MANUAL

Similar documents
Multicom 1550nm High Power Erbium Doped Fiber Amplifier MUL 2RU EDFA 1550 XX xx

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL

Ver. 1.0en 1550nm Erbium Doped Fiber Amplifier GA5100 Seriess USER R MANUAL

OTEB-CO-B Series. Booster EDFA OPERATING MANUAL

OTEA-CO-M Series EDFA. EDFA with Mid-Stage Access. Operation Manual

GEU Port Gigabit Switch

EDFA-4400A series 1550nm CATV Erbium Doped Fiber Amplifier

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

FSW-1609TFX FSW-2409TFX

FSW-1610TX FSW-2410TX

Fiber Optic. Foreword. Special Tips:

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

HES-3106-PLUS SERIES

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Perle SMI Media Converter Installation Guide

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

FRG-3105 Series Residential Gateway

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide

User Guide. FSW-1641TX/2441TX 16/24 10/100Base-TX Web Smart Switch. FSW-1641TX 16 port 10/100Base-TX Web Smart Switch

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

FWRIII-2105 SERIES. 4 ports 10/100Mbps RJ-45; built-in IEEE802.11n WiFi and 1 port 100Mbps SFP slot uplink Residential Gateway. Residential Gateway

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

24-Port Gigabit Ethernet Switches

GSW-2453 Gigabit Chassis switch. User Guide

FHU-0505TXDS FHU-0805TXDS FHU-1605TXDS

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

SWITCH, 24 POE PORTS ART. IPSWP240A

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

Technical passport / EDFA nm Optical Amplifier EDFA-1550/24 (4 17)

ex-s1110-xt Gigabit Ethernet Extenders

SWH-3112 Series 12-port L2+ Managed Gigabit Fiber Switch User s Guide

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

Junos WebApp Secure 5.0 Hardware Guide

Module Connectors and Cable Specifications

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

CATV EDFA Optical Amplifier 1550nm 24dBm. User Manual. L-RF-EDFA-24dBm

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

EDFA PON Port High-power 1550nm. XCOM series Fiber Amplifier Manual

Industrial 3-Port Fast Ethernet Media Converter Switches

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

100Base-FX to 10/100Base-TX. PoE. Media Converter. FCU-1802Px. User s Manual

16-SLOT IN-BAND MANAGEMENT CHASSIS

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Ether-FSH2400C 24-port 10/100Base-TX Switch

Overview. Features CHAPTER

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

iconverter 2-Module Power Chassis

FL MC 2000E (SM40) LC

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

D-Link Switch User Manual. Table of Contents

16-Port Chassis Media Converter System Manual

EOS-6000 Series Optical A/B Switch User Manual DC Version

LevelOne FSW PoE Fast Ethernet Switch User Manual

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

exp-s1110pe PoE+ Gigabit Ethernet Extenders

Micro-Switch/ port 10/100Mbps. Desktop Fast Ethernet Switch. (Auto MDI/MDIX) FEP T- 3 USER S MANUAL

KFC-200. Installation Guide

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

Table of Contents. 1 Welcome. 2 Install your Access Point-I. 3 Using the Access Point-I

2-Port Wireless Access Controller EWS4502. Installation Guide.

Hardened PoE Ethernet Switch

AX3000 Platine Terminal Ethernet TCP/IP

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

DynaGST/2402G. 24 Port 10/100/1000Base-T Gigabit Ethernet Switch with two SFP (mini) GBIC Slots PN: GEP-33224T USER S MANUAL

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

Perle Gigabit Media Converter Module. Installation Guide P/N

Cisco ONS CL Shelf Assembly Hardware

Setting Up Your Cisco Unified Videoconferencing 3515 MCU

5/8-Port 10/100Mbps Fast Ethernet Desktop Switch

TEG-S224TX 26-Port 10/100/1000Mbps Gigabit & Fast Ethernet Switch

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

FOS-3114 Series 14-port L2+ Managed Gigabit Fiber Switch User s Guide

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Perle 10GT Media Converters

Installing the Cisco Unified Videoconferencing 3545 MCU

High-power 1550nm Fiber Amplifier Manual. Transmitter

Hardened Web-Smart High Power PoE Ethernet Switch

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

Transcription:

Ver. 2.0en 1550nm CATV Erbium Doped Fiber Amplifier EDFA-4429 Series USER MANUAL

CONTENTS 1.0 PRODUCT SUMMARY... 1 2.0 INSTALLATION... 1 2.1 Unpacking... 1 2.2 EDFA Mounting and Power Connection... 1 2.3 Optical connectivity... 2 3.0 EDFA CONTROLS, INDICATORS, AND ALARMS... 4 3.1 Operation of the panel... 4 4.0 PORT AND CABLE ASSIGNMENTS... 6 4.1 Management Port (RJ-45)... 7 4.2 RS232 Console port (DB9)... 9 4.3 Power Connection... 10 5.0 FAULT MESSAGES... 10 5.1 Warning status... 11 5.2 Alarm status... 11 5.3 Fault troubleshooting... 11 6.0 WARRANTY AND REPAIRING UNITS... 12

1.0 PRODUCT SUMMARY EDFA-4429 series high power single mode EDFA is characterized by low noise and high linearity. It offers a flexible, low-cost solution for CATV large area coverage of metropolitan areas and medium-sized cities. EDFA-4429 series amplifiers are equipped with complete APC, AGC and ATC controls and have an excellent design for heat-dissipation, guaranteeing long MTBF values for the laser pump. RS232 and RJ45 interfaces on the front panel offer serial communication and SNMP network access for local or remote management. The wide LCD screen displays all the operating parameters and any alarms. Laser will be automatically switched off if optical input power is missing, protecting the laser and automatically resuming operation when new input is detected. All optical outputs are located on the front panel (optional order for back panel is available). EDFA-4429: 1RU chassis, total output power >1000mW, offers maximum 16 optical outputs. 2.0 INSTALLATION 2.1 Unpacking Please inspect the shipping boxes for any obvious damages. Unpack the unit from all packaging boxes. Inspect the appearance of the unit for any shipping damages. Document and inform the shipping company and your local representative, if any damage was found. Save the shipping boxes and their inserts for future reshipment in case the products need any upgrade or repair. NOTE: When reshipping products (returning them back to the vendor, distributor or manufacturer), warranty will be void if products are damaged due to use of non-original protection packaging. The EDFA units contain sensible mechanical parts that can be damaged by improper handling. 2.2 EDFA Mounting and Power Connection 1. Place the unit into a 19-inch wide rack or cabinet. Make sure to leave a 1.75-inch (about 4.5cm) space above and below the unit. 2. The EDFA-4429 series 1550nm can work between 0 C~50 C (32 F~122 F)temperature range. We recommend 25 C(77 F)environment temperature. Humidity should not exceed 95% ( under non-condensing Page 1 of 12

conditions). If necessary, should keep the equipment working in the suitable temperature & humidity (within the restrained scope). We recommend operating unit in a dust free environment. 3. EDFA equipment can be powered by AC or steady DC voltage. In both of AC & DC, AC is the main power supply. Request of power supply: AC input 94-245VAC, 50-60Hz DC input 36-60VDC, (48V source recommended) Power consumption Maximum 50W 4. The DC power supply of the equipment must be the SELV supply type as stipulated in the CAN/CSA C22.2 No.950-95 standard. 5. Unit should have good grounding with grounding resistance < 4Ω. According to common international standards, AC plugs must be tri-wire with the middle wire being the grounding wire. Before connecting power circuit, please use appropriate (#20AWG or more) electric wire to connect the grounding screw on the bottom to the grounding frame. When using DC input power supply, the equipment chassis must be grounded following the appropriate procedures for the respective location. 2.3 Optical connectivity 1. Clean all fiber patch cords before connecting to the EDFA unit. Cleaning Guidelines: Fiber Patch cord connectors - Remove the dust cap of the fiber connectors and wipe the fiber connector tip with a dry lint-free cloth. Check if there are scratches or debris on the connector surface by using a microscope (ie.100x or 200x). - If no scratch or debris are found, the connector is ready for connection. If scratches or debris are found, repeat the fiber patch cord connector cleaning guidelines. Fiber Bulkhead connectors - Compressed air may be used to clean fiber bulkhead connectors. Use compressed air according to the following specifications (at least): - Non-residue, inert gas for precision dust removal - Ultra-filtered to < 0.2 microns - Recommended for optical systems - Using compressed air as listed above, remove the bulkhead dust cover and hold the can of compressed air about 6 inches away from the connector. After spraying a few short bursts into the bulkhead, Page 2 of 12

the connector is clean and ready for connection. - If compressed air is not available, the transmitter fiber bulkhead connector may be cleaned by 2.5 mm alcohol sponge, or the connector plate may be removed to clean the internal fiber patch cords. CAUTION: The use caution when handling fibers. Do not exceed fiber manufacturer s pulling tension or bend radius specifications when removing fiber bulkhead connector plate. -To remove the transmitter optical connector plate, remove the screw on the far left of the optical plate and remove the screw on the far right of the optical plate. Do not remove the screws on the optical bulkhead connector. - Slowly remove the optical connector plate from the rear panel and disconnect each fiber connector from the bulkhead mounted on the plate. - Clean each fiber connector according to the fiber cleaning guidelines. 2. Make sure the laser key switches on the front panel of the transmitter are in the OFF position. 3. Connect the fiber patch cord from the output of the transmitter to the optical power meter. 4. Turn the transmitter laser key switch to the ON position. 5. Use the optical power meter to verify that the transmitter optical power follows the specifications. 6. Turn the transmitter laser key switch to the OFF position. Page 3 of 12

3.0 EDFA CONTROLS, INDICATORS, AND ALARMS This section of the manual will give an overview of the available menus in the EDFA-4429 series EDFA and their descriptions. All instructions in this section 3.0 refer to the representation of the front panel shown in the diagram below. The user can scroll through the EDFA menus by using the push buttons that are on the front panel on the right of the LCD screen. 3.1 Operation of the panel 3.1.1 Open menu A. Connect 48V power supply B. Turn on power switch in the back panel, Front panel displays "KEY OFF" Laser Status lamp is Red C. Input power, then press laser start-up key switch Front panel shows "KEY ON ",Laser status lamp turns green from red. 3.1.2 Start-up main menu Press / buttons and the following menu will be displayed in a sequence cycle. Menu #1 - Model Read-only menu, tells the type of this equipment Menu #2 - S/N Read-only menu, tells the serial number of this equipment Menu #3 - Input Read-only menu, tells the input optical power of EDFA Menu #4 - Set Output Adjustable list, set the output power in dbm Menu #5 - Total Output Read-only menu, tells the output optical power of EDFA in dbm. Page 4 of 12

Menu #6 - Each Output Read-only menu, tells the each output of EDFA in dbm. Menu #7 - PA Current Read-only menu, tells the pre pump current of EDFA Menu #8 - PA TEC Read-only menu, tells the pre pump tec Menu #9 - PA Temp Read-only menu, tells the pre pump temperature of EDFA Menu #10 - BA Current Read-only menu, displays the amplifier current of EDFA Menu #11 - Power1 Read-only menu, tells the status of power1 Menu #12 - Power2 Read-only menu, tells the status of power2 Menu #13 - Unit Temp Read-only menu, tells the case temperature Menu #14 - IP Adjustable list, displays the IP address Menu #15 - SUB Adjustable list, displays the address of net mask Menu #16 - GW Adjustable list, displays the gateway address Menu #17 - TR1 Adjustable list, displays the TRAP1 address Menu #18 - TR2 Adjustable list, displays the TRAP2 address Menu #19 - LCD Contrast Level Adjustable list, displays the LCD contrast level adjustment Menu #20 - Reset Settings Adjustable list, displays the reset settings Page 5 of 12

3.1.3 Assistant manual 1. Set output power Under the menu of Set Output, press the button at the same time to enter the modified menu, press / button to increase or decrease value, press the button at the same time to save and exit. 2. Set IP, Sub-mask, Gateway, Trap1, Trap2 menu Under the menu of IP, Sub-mask, Gateway, Trap1, Trap2, press the button at the same time to enter into modified menu, press / button to select the menu that need to modify, press the button at the same time to select the modified key position, press / button to modify the value on this position, and then press button at the same time to save and exit. For example: modify IP: 192.168.000.015; if value needs change from 5 to 6, press button at same time to enter into IP address menu, press button at same time to select 5 this position, then press / button to change 5 to 6, and then press button at same time to save, the modified IP is 192.168.000.016. 3. LCD Contrast Level (Set LCD Contrast Level) Select this menu, press the button / at the same time to enter the modified status, press the button / to set the brightness of the LCD, last press the button / at the same time to save. 4. Set Reset Settings menu Choose Reset Setting menu, press button at same time to enter modify status, press / button to select the restore factory setting, press the button at the same time to save and exit. 4.0 PORT AND CABLE ASSIGNMENTS EDFA-4429 series has the following management ports: RS232 port: suitable for examining EDFA-4429 parameters and some system configuration by serial RS232 port (PC with console/terminal software, such as PuTTY). SNMP: Simple network management protocol. Before connecting the EDFA-4429 by the RJ45 port, please read the following instructions and port connectivity requirements. Page 6 of 12

4.1 Management Port (RJ-45) 4.1.1 Port Description The EDFA-4429 series management port connector type is RJ-45. 8 8 1 1 Figure 4.1.1 RJ 45 Connector Plug and Socket The Management port (RJ-45) can be connected to any device that uses a standard network interface (e.g., a workstation, server, bridge or router). RJ-45 MDI can connect with similar network equipment (such as other EDFA-4429 or network Hub). Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45 connections: 100-ohm Category 3, 4 or 5 cable for 10 Mbps connections or 100- ohm Category 5e cable for 100 Mbps connections. Please make sure that the cable length does not exceed 100 meters (305 feet). 4.1.2 Pin assignment For network management connectivity (RJ-45 connector in each side, NMS PC to EDFA-4429 series direct connection) a straight cable should be used. See Figure 4.1.2. Figure 4.1.2 RJ-45 connector straight through connecting Page 7 of 12

PIN Workstation port MDI 1 Input receive data+ Output transmit data+ 2 Input receive data- Output transmit data- 3 Output transmit data+ Input receive data+ 6 Output transmit data- Input receive data- 4, 5, 7, 8 Nonuse Nonuse Table 4-1 RJ-45 Pin assignment Straight Cross (EDFA-4429) (Adapter) (EDFA-4429) (HUB/ EDFA-4429) 1 IRD+ 1 OTD+ 1 IRD+ 1 IRD+ 2 IRD- 2 OTD- 2 IRD- 2 IRD- 3 OTD+ 3 IRD+ 3 OTD+ 3 OTD+ 6 OTD- 6 IRD- 6 OTD- 6 OTD- Table 4-2 Straight and cross cable connecting 4.1.3 Port Connection EDFA-4429 series can automatically detect the Ethernet cable type (Straight-though or Crossover), so either type can be used. An Ethernet twisted pair cable should be connected between the RJ-45 connector (MDI-X) of the EDFA-4429 series and any device with a standard network interface (such as a work station or server), or to a network interconnection device (such as a bridge or router). 1) Ensure that the device to be connected has a 10BASE-T or 100BASE-TX network interface card (NIC). 2) Prepare a twisted pair Ethernet cable with RJ-45 plugs on each end. Use Cat 3, 4 or 5 cable for standard 10Mbps Ethernet connections, or Cat 5e cable for 100Mbps Fast Ethernet connections. 3) Plug one end of the cable into the PC's NIC and plug the other end into any RJ-45 port of the EDFA-4429 series. All the EDFA-4429 RJ-45 port supports both 10Mbps and 100Mbps Ethernet connections. Ensure that the plug's locking tab clicks into proper position to make good access. Caution: Do not plug a phone jack connector into the RJ-45 port. This may damage the EDFA. Instead, use only twisted-pair cables with RJ-45 Page 8 of 12

connectors that conforms to FCC standards. Note: 1) Connect other compatible EDFA-4429 series or network hub, adopt direct or across cable to connect MDI port in other device. 2) Ensure that the twisted pair cable length does not exceed 100 meters. 3) Cat 5 cable is recommended for all network connections to avoid confusion or inconvenience, when upgrading to Fast Ethernet devices in the future. 4) Cascade length provision: IEEE 802.3 standard prescribes that through twisted pair at most 4 hub (such as repeaters) can be cascade, and IEEE 802.3u standard has more strict order for high-speed Ethernet. So, when cascade device except for this EDFA-4429 series, please follow the above connection regulation. But, please don t reckon in the EDFA-4429 series or connected cable related device in cascade length, because EDFA-4429 series divide the connected path into unattached port. 4.1.4 Connection Management (Out-Band) Remote management can be performed through the dedicated Management port (10/100BASE-TX port) on the front of the EDFA-4429 or any 10/100BASE port of EDFA-4429. Before the Management port is accessed through LAN port, please configure the IP address and subnet mask by serial port according to network configuration requirement. 4.2 RS232 Console port (DB9) 8 1 4.2.1 Port Description Page 9 of 12

Figure 4-2.1 DB9 interface DB9 interface is a standard connector used in RS232 in series communication connects. EDFA adopts 9 pin standard connector which is same as the connector of PC Com interface. 4.2.2 Pin assignment Figure 4-2.2 DB9/RS232 pin assignment Pin Distribution 2 RXD: accepting of data 3 TXD: transmitter data 5 SG: signal Table 4-3 Pin information 4.3 Power Connection 4.3.1 Connection Description The power module provides stable operating power for the system, to meet the power supply requirements of all the components in the system. 5.0 FAULT MESSAGES EDFA-4429 series FTTP EDFA can monitor system operation and generate brief warning notes, taking corrective actions regarding system parameters, equipment tolerance, laser aging, RF level changing, and temperature changing. The laser Page 10 of 12

PUMP will continue to operate during warnings and some alarms. Warnings and alarms may disappear if the unit is detecting that system parameters recover into normal range. Some of the critical warnings can be eliminated by restarting the power supply. All warnings will disappear automatically if parameters recover to normal range. Most of warnings will be sent out when the correction ability is close to or exceed the permitted range. At most situation, user cannot modify these statuses. Status modification needs special equipment & available facility, so the modification can only be processed in the factory. 5.1 Warning status When pump laser is on warning status, the status LED will turn red and the brief note of status will be displayed on the screen. The warning will not make the EDFA stop running, and it only shows the relative parameter exceeding to normal scope slightly. If the warning is stopped, it shows that the relative parameter is returned into permitted scope. The screen & LBD will return to their normal status and there is no need for user to interfere. But what should emphasize is that the problem showed by alarm cannot be ignored, because there may be some serious system faults. Work status Status display LED color Explanation Present laser deflection is low Key Off Red The EDFA isn t working. It s shut down. Present case temp - Red Warning when the temp 60 C. Input Input Low Red Optical output power is low. Output Output Low Red Optical output power is low. Table 5-1 Warning status 5.2 Alarm status When the pump laser sends out warning, it will stop working generally. The alarm is because some relative parameter exceeds its safety working scope or some situation causes damage to the laser. The alarm can be eliminated by restarting the power supply or resetting the key switch. If the user cannot eliminate the alarm, please contact our company immediately. 5.3 Fault troubleshooting Please read the below information to prevent some potential problems. 1. Please place equipment under environment temperature of 0 C ~50 C, and other conditions follows the requested running range. We suggest placing the EDFA in low dust environment. 2. Ensure the rear panel fan & front panel sockets are clear and with Page 11 of 12

adequate space for proper ventilation. 3. Check the power supply connectivity and proper wiring of power supply lines. 4. Check RF gain value adjustment and make sure is within the proper range. 5. Always keep the optic fiber connectors clean. Prevent the output optical power decrease caused by optic leakage. 6.0 WARRANTY AND REPAIRING UNITS 1. Each unit is packaged with<product QA> and serial number. We do provide two years warranty for the product. 2. The software CPU has the purpose of monitoring laser status, digital display, alarms and network management. In case of red LED blinking (Alarm), please return the equipment for repairing. User should not open the top cover for repairing; opening the cover of the EDFA unit will void the warranty, maintenance and material fees will be charged for repair if the unit has been tampered. 3. Lifetime maintenance and upgrade for all EDFA products is provided after warranty period has expired. 4. If components are damaged by user tampering or mishandling factors, repairing fees will be charged. Page 12 of 12