PTC/PT100 board 2.0 Option

PTC/PT100 board 2.0 Option

PTC 2.0 Option board. PTC/RTC Option board. Instruction Manual English. For Emotron VFX/FDU 2.0-IP2Y AC drive. For Emotron FlowDrive-IP2Y

RTC- Real time clock board Option

Emotron Safe Stop board Option

Technical Catalogue Softstarters

Operating instructions. Switching amplifier DN0210 DN / / 2015

Emotron AC drive Master-follower functionality

Operating instructions. Speed monitor D / / 2014

MC 11 EB-2 Power supply cabinet with external bus, AC version

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

CPCI-PS24 24V-Power Supply

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

RTD-W Installation Instructions

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Your choice for wall and panel mounted AC drives. Emotron FDU & VFX IP20/21 up to 132 kw

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

Supplementary operating instructions for your air curtain system Controller TMC 500

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

Model 7705 Control Module

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Product and functional description

TPE, TPED Series 2000

Display Panel BAT 100 LSN. en Operation Guide

TRC-190 User s Manual

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

TRIO-DIODE/12-24DC/2X10/1X20

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Bulletin 817 Thermistor Protection Relay

SM-I/O Plus. Solutions module for UNIDRIVE SP. User guide. This manual is to be given to the end user. Réf en / a

Resolver to Digital Expansion Board

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Operation Manual Series W-500

SMVector Additional I/O Module Installation and Operation Manual

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

Chameleon Stand-alone

F1000 User's Manual. (Version: V1.01)

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Product and functional description

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector

Super universal modules

Options for ABB drives, converters and inverters. User s manual FDIO-01 digital I/O extension module

ASTAT XB/XBm Remote Operator

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

Non-communicating room controllers

CUS150M1 Instruction Manual

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

SX90 Process Controller

SIMOREG 6RA70 DC MASTER SIMOREG CM

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Expansion Module HZS 541-1S

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

High dynamics for demanding applications

Operating Instructions VEGAMET 381

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

LCI User Manual mantracourt.com

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Installation Instructions

Vision OPLC V TR6/V350-J-TR6

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

SIMOCODE 3UF Motor Management and Control Devices

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

TRC-190 User s Manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

STEP-PS/1AC/24DC/1.75

Product and functional description

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

MINI-PS AC/10-15DC/8

Installation manual CF8-W-Disp-AL

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

QUINT-BUFFER/24DC/24DC/40

Transcription:

PTC/PT100 board 2.0 Option For Emotron VFX/FDU 2.0 AC drive and Emotron TSA softstarter Instruction Manual English

PTC/PT100 board 2.0 Option For Emotron VFX/FDU 2.0 AC drive and Emotron TSA softstarter Instruction Manual - English Document number: 01-5920-01 Edition: r1 Date of release: 04 March 2013 Copyright CG Drives & Automation Sweden AB 2011-2013 CG Drives & Automation retains the right to change specifications and illustrations in the text, without prior notification. The contents of this document may not be copied without the explicit permission of CG Drives & Automation Sweden AB.

Safety Instruction manual Read this instruction manual first! This option is a supplementary part of the Emotron FDU/Emotron VFX AC drives and EmotronTSA softstarters, hereinafter in this manual referred to as the main product and the user must be acquainted with the original instruction manual of the main product. All safety instructions, warnings, etc. as mentioned in this instruction manual must be known to the user. Safety instructions Read the safety instructions in the instruction manual for the main product. Installation Installation, commissioning, dismounting, making measurements, etc. on the main product may only be carried out by personnel who are technically qualified for the task. Installation must also be carried out in accordance with the local standards. Ensure that all necessary safety measures are taken. WARNING! Take all necessary safety precautions during installation and commissioning to prevent personal injuries, e.g. by an uncontrolled load. Opening the main product WARNING! Always switch off the mains supply before opening the main product. For AC drives, wait at least 7 minutes to allow the buffer capacitors to discharge. Always take adequate precautions before opening the main product, even though the connections for the control signals and jumpers are isolated from the mains voltage. CG Drives & Automation, 01-5920-01r1

CG Drives & Automation, 01-5920-01r1

Contents Safety... 1 Contents... 3 1. Introduction... 5 2. Connections and functions... 7 2.1 Board layout... 7 2.2 General information... 8 2.3 PTC input... 12 2.4 PT100 input... 15 3. Installation... 21 3.1 Polarisation of flat cables (AC drive)... 22 3.2 Mechanical mounting on AC drives... 23 3.3 Mechanical mounting on Emotron TSA... 27 CG Drives & Automation 01-5920-01r1 3

4 CG Drives & Automation 01-5920-01r1

1. Introduction This board is used to connect motor thermistors (PTC) acc. to DIN44081/ 44082 and/or PT100 sensors acc. to IEC 60 751 to the main product. Note that both the PTC and the PT100 sensors needs to be isolated from live voltage, see 2.2.4, page 12 for further details. There are three terminals on the option board, X1 - X3. X1 and X2 are for PT100 input and X3 for PTC input. Both PTC and PT100 functions can be used for thermal motor protection. When the monitored temperature e.g. motor temperature becomes too high, the main product will trip. The PT100 function can be used as a process temperature feedback to optimise the control. The PT100 function can also be used for monitoring measured temperatures by the analogue comparators and the programmable levels. CG Drives & Automation 01-5920-01r1 Introduction 5

6 Introduction CG Drives & Automation 01-5920-01r1

2. Connections and functions 2.1 Board layout X5B OUT IN X5A D3 STATUS 21 22 X3 X2 11 12 13 14 1 2 3 4 5 6 7 8 X1 Fig. 1 PTC/PT100 option board layout CG Drive & Automation 01-5920-01r1 Connections and functions 7

2.2 General information 2.2.1 Menus The following menus are available when the PTC/PT100 option board is installed in the main product. All menus are described in the manual for the main product. Menus for Emotron FDU/ VFX AC drives Table 1 Menus for AC-drives available with the PTC/PT100 option board Menu Function Default Range/Selection 234 Thermal protection Off 235 Motor Class F140 71B PT100 1, 2, 3 - Off = No thermal protection PTC = PTC protection enabled PT100 = PT100 protection enabled PTC+PT100 = Both protections enabled A 100 C, E 115 C, B 120 C, F 140 C, F Nema 145 C, H 165 C Shows the measured temperatures with a resolution of 1 degree, for all three PT100 inputs. 8 Connections and functions CG Drives & Automation 01-5920-01r1

Menus for Emotron TSA softstarter Table 2 Menus for Emotron TSA available with the PTC/PT100 option board Menu Function Default Range/Selection 21C Units SI SI/US 71B PT100B1 123-71C PT100B2 123 - Shows the measured temperatures with a resolution of 1 degree, on the first PTC/PT100 option board. Shows the measured temperatures with a resolution of 1 degree, on the second PTC/PT100 option board. 232 PT100 Alarm 2321 PT100 Alarm action 2322 Motor Class F140 2323 PT100 inputs 233 PTC Alarm No Action No action, Hard trip, Soft trip, Warning PT100 1-3 A 100 C, E 115 C, B 120 C, F 140 C, F Nema 145 C, H 165 C Select active inputs: PT100 1, PT100 1-2, PT100 1-3, PT100 1-4, PT100 1-5, PT100 1-6 (1-3 = Board 1, 4-6 = Board 2) 2331 PTC Alarm action No Action No action, Hard trip, Soft trip, Warning 2332 PTC Inputs PB-PTC PB-PTC = Power board PTC input is enabled. Note! not available on this option board, see main product instruction manual. PB-PTC & Opt1 = both the PTC input on the power board and on the first option board are enabled. PB-PTC & Opt1-2 = both the PTC input on the power board and on both option boards are enabled. NOTE: Always use the on board (main product) PTC input (PB-PTC) first. Additional PTC s can be connected to first and second option board. CG Drive & Automation 01-5920-01r1 Connections and functions 9

2.2.2 Status LED For location of status LED, see Fig. 1. Table 3 Specification of status LED LED Specification D3 Flashing slowly (1 Hz) = OK Flashing fast = communication error Off = no power supply 2.2.3 Cable recommendations and shielding Shielded twisted pair cables are recommended. Connect the cable shield firmly (low ohmic connection) to the mounting plate (PE) according to Fig. 2 on AC drives or Fig. 3 on Emotron TSA. Mounted option board Shield Shield clamp Signal wires Fig. 2 General shielding principle on AC drives 10 Connections and functions CG Drives & Automation 01-5920-01r1

Mounted option board Signal wires Mounting plate/surface connected to earth Tie wrap Shield Tie wrap Fig. 3 General shielding principle on Emotron TSA softstarter (example with I/O board) The shield must end at the Clamp/tie wrap. Only the signal wires should continue to the terminals of the PTC/PT100 option board. In most cases it is recommended that both ends of the shield are connected to PE. This will give a good attenuation of high frequency interference. Shield connections should be made using the largest possible surface. Make sure that you select a cable of material appropriate for your environment. Consider ambient temperature, humidity and occurrence of chemical substances such as oil. Standard copper wire with cross-sectional area of approximately 0.14-1.5 mm 2 will be sufficient in most cases. CG Drive & Automation 01-5920-01r1 Connections and functions 11

2.2.4 Isolation The control board in the main product is a Separated Extra Low Voltage (SELV) circuit. This means that this board is safely separated from other circuits that carry higher voltages and is isolated from earth and protective earth conductors of other circuits. The PTC/PT100 circuit on this option board is separated from the control board SELV circuit with separation rated for: 1. Double insulation when used in main product rated up to 480 VAC. 2. Basic insulation when used in main product rated up to 690 VAC. It is recommended that the PTC/PT100 sensors are always separated from live parts with at least basic insulation for the relevant voltage. WARNING! For main products rated higher than 480 VAC it is mandatory to have at least basic insulation between the temperature sensor and live voltage. 2.3 PTC input This PTC input is for safety reasons isolated from internal supplies and electronics, see 2.2.4, page 12 for detailed information. The PTC sensor should be connected to terminal X3. No polarisation is needed. Up to six PTCs may be connected in series according to DIN44081/44082. Table 4 Terminal configuration for PTC connection X3 Name Function 21 T1 PTC input 22 T2 PTC input 12 Connections and functions CG Drives & Automation 01-5920-01r1

2.3.1 Electrical specification R [k ] 100 10 2.825 1.500 1 Trip Reset 0.1-20 T switch T [ C] Fig. 4 Typical PTC-curve The figure above shows a typical PTC-curve. The resistance increases drastically with the temperature after a certain switch temperature, T switch, which is typically 60-120 C (depending on PTC type). Table 5 Electrical specifications for the PTC input Number of PTCs 1 to 6 in series acc. to DIN44081/44082 Trip at 2,825 10 % Reset at 1,500 10 % Measurement voltage U T1-T2 at T switch <1 VDC CG Drive & Automation 01-5920-01r1 Connections and functions 13

2.3.2 PTC connection example 21 22 X3 Fig. 5 Connecting a PTC T1 X3:21 L1 L2 L3 M T2 X3:22 3~ Fig. 6 Example of an application with three PTCs in series. 14 Connections and functions CG Drives & Automation 01-5920-01r1

2.4 PT100 input The PT100 input is according to EN60751. Connector X1 and X2 on the PTC/PT100 option board have the following terminal configuration: Table 6 Terminal configuration for PT100 input X1 Name Function 1 Feed_1+ Constant current feed channel 1 2 PT100_1+ Positive input for PT100 channel 1 3 PT100_1- Negative input for PT100 channel 1 4 Feed_1- Constant current feed channel 1 5 Feed_2+ Constant current feed channel 2 6 PT100_2+ Positive input for PT100 channel 2 7 PT100_2- Negative input for PT100 channel 2 8 Feed_2- Constant current feed channel 2 X2 Name Function 11 Feed_3+ Constant current feed channel 3 12 PT100_3+ Positive input for PT100 channel 3 13 PT100_3- Negative input for PT100 channel 3 14 Feed_3- Constant current feed channel 3 NOTE: PT100 inputs which are are left unconnected will indicate a temperature of approximately -99 degrees. CG Drive & Automation 01-5920-01r1 Connections and functions 15

2.4.1 Electrical specifications PT100 [ ] 175.84 138.50 100.00 0 100 200 T [ C Fig. 7 Table 7 Graph of the PT100 resistance/temperature relationship. Electrical specifications for PT100 input Standard Temperature range Accuracy EN60751-100 C to +300 C 1% off full scale Menu [71B] in the main product shows the temperatures measured for the PT100 element, with a resolution of 1 degree, for each PT100 inputs. Emotron TSA. Menu [71C] shows the element measured temperatures, with a resolution of 1 degree, for all three PT100 inputs on the second installed PTC/PT100 option board. 16 Connections and functions CG Drives & Automation 01-5920-01r1

2.4.2 PT100 connection examples Three PT100 channels are available for temperature measurement. All three PT 100 channels (X1, pins 1-8 and X2, pins 11-14) can be used as a 4-wire input which can be used for precision measurement to avoid measurement errors due to resistance in connecting wires. 11 12 13 14 X2 PT100 sensor 1 2 3 4 5 6 7 8 X1 PT100 sensor Fig. 8 Connecting PT100 sensors for 4-wire temperature measurement NOTE: To achieve proper 4-wire temperature measurement it is important that Feed_x+ is connected to PT100_x+ and Feed_x- is connected to PT100_x-. Make sure that the terminal screws are tightened to achieve a low ohmic connection. CG Drive & Automation 01-5920-01r1 Connections and functions 17

It is also possible to use these 4-wire inputs as a 2-wire input by putting a jumper between Feed_x+ and PT100_x+ and one between Feed_x- and PT100_x-. See figure below. 1 Feed_1+ PT100_1+ PT100_1- Feed_1- X1 PT100 sensor Fig. 9 Using 4-wire input as 2-wire input. Motor thermal protection Emotron AC Drives. When the PT100 function is enabled by selecting function PT100 or PTC+PT100 in menu [234] and the correct motor class is selected in menu [235] this PT100 function will automatically protect the connected motor against overheating. Emotron TSA. When the PT100 function is enabled by selecting function PT100 or PTC+PT100 in menu [232] with submenus and the correct motor class is selected in menu [2322] this PT100 function will automatically protect the connected motor against overheating. For PT100 supervision and alarm, setup menus: [2321] PT100 Alarm action, [2322] Motor class, [2323] PT100 inputs accordingly. For PTC supervision and alarm, setup menus: [2331] PTC Alarm action [2332] PTC inputs accordingly Process value When PT 100 is selected in menu [321], the PT100 element is used for feedback of e.g. the actual process temperature. In Emotron AC drives this can be used with the process PID regulator. to establish an optimised temperature control. In Emotron TSA softstarters the PT100 temperature signals can be used for temperature start/stop control. 18 Connections and functions CG Drives & Automation 01-5920-01r1

Monitoring Example: PT100_1, PT100_2 or PT100_3 is selected as a Comparator Value in one of menus [6111] to [6114]. The measured temperature for the concerning PT100 can be used to monitor the temperature level. This analogue comparator output can activate a (alarm) signal via Digital Output or Relay. It can also be used to start an action (e.g. start/stop) in combination with the comparator and the Virtual Connections. See the main product instruction manual for more information. CG Drive & Automation 01-5920-01r1 Connections and functions 19

20 Connections and functions CG Drives & Automation 01-5920-01r1

3. Installation This chapter describes how to mount the option board in the main product. On AC drives up to three different option boards and one communication board can be mounted. On Emotron TSA softstarters up to two option boards and one communication option can be mounted. The option kit includes option board. Four screws. One 16-pole flat cable, approx. 75 mm long. This cable is used to connect the first option board on AC-drives only. One 16-pole flat cable approx. 32 mm long, for connection between two option boards. This cable is also used to connect the first option board on Emotron TSA softstarter. Insulating sheet - only for use on AC drives. For Emotron TSA the insulation sheet is integrated with the product. X5A X5B 75 +3-0 CG Drives & Automation, 01-5920-01r1 Installation 21

3.1 Polarisation of flat cables (AC drive) The flat cable is marked with a colour on one side and has a pin on the micromatch male contact. This side must be matched to the female micromatch contact on the control board and option board respectively, where a small hole in the board is located. Fig. 10 Polarisation of flat cables (Example on AC drive)! CAUTION! Incorrect connection might cause damage to both the option and to the control board/external equipment. 22 Installation CG Drives & Automation, 01-5920-01r1

3.2 Mechanical mounting on AC drives Make sure that the AC drive has been switched off for at least seven minutes to ensure that the capacitor bank is discharged before continuing with installation! Also make sure that no external equipment connected to the drive s interface is powered on. NOTE: Correct installation is essential for fulfilling the EMC requirements and for proper operation of the module. 3.2.1 Mounting the first option board The first option board is always mounted on the slot marked 1 on the mounting plate. In this example we assume that no other option board is installed. 1. Connect the 16-pole flat cable (75 mm) to the X5 connector on the control board with the cable downwards as in Fig. 11. NOTE: For polarisation of the flat cable, see section 3.1 on page 22. Fig. 11 Flat cable connected to the control board CG Drives & Automation, 01-5920-01r1 Installation 23

2. Place the insulating sheet over the short spacers on the slot marked 1 on the mounting plate. Make sure the flap bent upwards is mounted towards the control board interface as in the figure below. Fig. 12 Mounted insulating sheet 3. Connect the other end of the 16-pole flat cable to the X5A connector on the option board. Make sure that the polarisation is correct as in section 3.1 on page 22. NOTE: Connect the micro match male contact to the option in the same manner as on the control board, i.e. the pin on the micro match contact must be fitted into the hole in the PCB. 24 Installation CG Drives & Automation, 01-5920-01r1

Fig. 13 Flat cable connected to the option board 4. Put the option board on the spacers. 5. Fasten the board using the four screws. Fig. 14 Mounted option board CG Drives & Automation, 01-5920-01r1 Installation 25

3.2.2 Mounting another option board 1. Place the insulating sheet on the spacers on the option board slot marked 2 or 3. It is necessary to select the slot closest to the already mounted option board. NOTE: Place the insulating sheet with the turned up flap facing the interface of the control board to achieve proper insulation between the option boards. 2. Put the option board on the spacers. 3. Fasten the option board on the spacers using the four screws. 4. Connect the short flat cable between the X5B connector on the first option board and the X5A connector on the option board you have just mounted. Flat cable connection Fig. 15 Two option boards mounted on the mounting plate 26 Installation CG Drives & Automation, 01-5920-01r1

3.3 Mechanical mounting on Emotron TSA Make sure that all power to the softstarter has been switched off before continuing with installation! Also make sure that no external equipment connected to the softstarters interface is switched on. NOTE: Correct installation is essential for fulfilling the EMC requirements and for proper operation of the module. 3.3.1 Mounting the first option board 1. Connect the short 16-pole flat cable (32 mm) to the X5A connector on the option board as in Fig. 16. X5A X5B Fig. 16 Connect the flat cable to X5A connector on the option board. CG Drives & Automation, 01-5920-01r1 Installation 27

2. Place the option board on the spacers at the option board slot marked 1. 3. Fasten the board using the four screws. 4 screws Fig. 17 Place the option board on the spacers and fasten it with the four screws. 4. Connect the other end of the 16-pole flat cable to the X4 connector on the control board. 28 Installation CG Drives & Automation, 01-5920-01r1

3.3.2 Mounting a second option board 1. Place the option board on the spacers at the option board slot marked 2. 2. Fasten the option board using the four screws. Flat cable connection Fig. 18 Two option boards mounted and interconnected with a flat cable. 3. Connect the short flat cable between the X5B connector on the first option board and the X5A connector on the option board just mounted. CG Drives & Automation, 01-5920-01r1 Installation 29

CG Drives & Automation Sweden AB Mörsaregatan 12 Box 222 25 SE-250 24 Helsingborg Sweden T +46 42 16 99 00 F +46 42 16 99 49 www.cgglobal.com / www.emotron.com CG Drives & Automation, 01-5920-01r1, 2013-03-04