GS Dupline Profinet Gateway. Benefits. Description

Similar documents
protocol can be used. The SB2WEB24 is also equipped with an RS485 port for communication

SBB4I2O230 ENG. Fire damper I/O Module. Benefits. Description

Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection

SA2WEB24. Central unit module. Benefits. Description

SH2WEB24. Central unit module. Benefits. Description

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

smart-house Controller Central Unit Module Type SH2WEB24

CM589 PROFINET Communication Module

X20(c)BC00E3. 1 General information. 2 Coated modules. X20(c)BC00E3

CM579-PNIO PROFINET Communication Module

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

CM589 PROFINET Communication Module

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Island bus expansion module

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

Web interface BACnet/IP

MGate 5102-PBM-PN Series

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

DI572 Digital Input Module

Stride Industrial Ethernet Switches

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

CM597 Ethernet Communication Module

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Ha-VIS mcon 3000 Next Generation Introduction and features

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

Energy Management BUS Adapter Type VMU-B

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

BL compact Multiprotocol Station for Industrial Ethernet 16 Digital PNP Inputs BLCEN-16M8LT-8DI-P-8DI-P

DI561 Digital Input Module

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Strand Lighting Specification

CI504 PROFINET Communication Interface Module

Valve island VM10 with PROFINET Interface 8, 10, 12 or 16 stations. Operation & Service Manual

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

Absolute encoders - bus interfaces

AI561 Analog Input Module

Quick Start Guide PROFINET Switch 4/8-port. Version. 1en.

TF501, TF521 Terminal Bases

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

02/11/2015

IntesisBox Modbus Server Panasonic

B5X-LS4-U. Light switch. Benefits. Description

DC561, digital input/output module,

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

SK CU4-PNT-C Part number:

General information. Display. Supply voltage. Input current

Energy Management BUS Adapter Type VMU-B 01

RM35LM33MW liquid level control relay RM35-L V AC/DC

BACnet/IP Web Interface

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

General information. Display. Supply voltage

Electronic timer CT-AHD.22

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

DC562, digital input/output module,

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC

Room automation station

Mini Energy Web Server

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Type code. BLCEN-8M12LT-4AI-VI-8XSG-P Ident-No Nominal system voltage 24 VDC. Nominal current Vo Max. current Vo

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual

PLC PFC200 Controller PFC200 CS 2ETH RS

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

Electronic timer CT-ERD.12

Multiturn absolute encoder

crio PN Installation Instructions V0.2/ COMSOFT

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

General information. Display. Supply voltage. Input current

CM592 PROFIBUS Communication Module

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

ETD-BL-1T-OFF-CC- 10S

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

HARTING Ha-VIS mcon 3000 Next Generation Full managed Ethernet PROFINET Switch

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

8 or 12-Port IEC Certified Industrial Managed Gigabit Switch. EHG9508 EHG9512 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved.

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Communication module to connect M-bus devices to POL6xx.xxx controllers.

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

EM270. Multi-channel power analyzer. Benefits. Description

Transcription:

Dupline Profinet Gateway Benefits Profinet gateway with the function as a slave Up to 7 master generators can be connected via the HS RS485 bus (side connector) All Dupline signals from the master generators are available on Profinet Mini webserver for diagnostics of Profinet and Dupline networks Integrated 2-port switch 2-DIN UWP housing 24-VDC power supply Description The is a Profinet gateway with a built-in 2-port switch. The module has no settings and works only in association with the master generator GS3390 0000 800. By installing the GSD file in the PLC, the installer can design the functionallity of e.g. digital in/out, analink, mux BCD and Dupline safe signals. After installation and connection it is possible, by using the mini webserver, to perform tests and diagnostics on both Profinet and the Dupline networks (up to 7 Dupline networks) Applications Any application with the use of digital in/out, analink, MUX BCD, Dupline Safe and Profinet Main functions Gateway between Dupline and Profinet 30/09/2016 ENG 1

Features Power Supply Power supply 24 VDC +/- 20% Overvoltage category Overvoltage category II (IEC 60664-1, par. 4.3.3.2) Rated impulse withstand voltage 500V (1,2/50µs) (IEC 60664-1, tab. F.1) Rated operational power 2.8 W Reverse-polarity protection Yes Connection A1 (+) and A2 (-) Power-ON delay Typ. 4 s Power-OFF delay 1 s Power supply to Ethernet bus 500 V impulse (1.2/50us) 500 V AC for 1 min Communication Profinet Conformance Class B RT_Class 1 UDP/IP-Comm LLDP-Frames Alarms SNMP-support LLDP-MIB Performance Characteristics 100 Mbps, full duplex with auto negotiation enabled as default Real Time (RT) communication, 250 µs cycle time Data Up to 128 subslots in total 1440 bytes of IO data in each direction, including status bytes Environmental Degree of protection Front Screw terminal Pollution degree 2 (IEC 60664-1, par. 4.6.2) Operating temperature -20... +50 C (-4... +122 F) Storage temperature -50... +85 C (-58... +185 F) Humidity (not condensing) 20... 80% relative humidity IP50 IP20 30/09/2016 ENG 2

EMC Immunity Emission EN61000-6-2 EN61000-6-3 Indication LED description Name Colour Behaviour HS-BUS Yellow ON: Bus OK, OFF: Bus not OK Error Red ON: Error detected, OFF: No error Profinet Communication Red ON: Bus OK, OFF: Bus not OK, Flashing: when the PLC requests it ETH1:RJ45 Link1 Green ON: Cable connected, OFF: Cable disconnected EHT1: RJ45 Activity1 Yellow Flashing: communication ETH2:RJ45 Link2 Green ON: Cable connected, OFF: Cable disconnected EHT2: RJ45 Activity2 Yellow Flashing: communication Power supply Green ON: Supply ON, OFF: Supply OFF LED Profinet LED status Description Comments (*) OFF Offline No power, No connection with IO controller ON Online (RUN) Connection with IO Controller established, IO Controller in RUN state 1 flash Online (STOP) Connection with IO Controller established, IO Controller in STOP state or IO data bad, IRT synchronization not finished Blinking Blink Used by engineering tools to identify the node on the network (*)Test sequences are performed on the network and module status LEDs during startup Error LED indication LED status Description Comments (*) ON Fatal event Major internal error 1 flash Station name error Station name not set 2 flashes IP address error IP address not set 3 flashes Configuration error Expected Identification differs from Real Identification (*)Test sequences are performed on the Network and module-status LEDs during startup 30/09/2016 ENG 3

45.0 Mechanics Housing Housing material Colour Dimensions (HxWxD) Weight Noryl Light grey 90 x 35 x 58.5 mm 110 g 35.0 5.0 90.0 90.0 5.0 45.0 44.0 35.0 44.0 14.5 14.5 30/09/2016 ENG 4

Wiring + A - A1 (+) A2 (-) BUS ERROR PROFINET ETH2 ETH1 ON Dupline ETH1 ETH2 PROFINET ETH1 B ETH2 A 24-VDC Supply B Ethernet switch Connection Terminal 2-screw type Cable cross-section area max. 1.5 mm 2 Tightening torque 0.4 Nm / 0.8 Nm 30/09/2016 ENG 5

Example of an installation with two MCG networks A B C E D A Profinet D Profinet gateway (Ethernet module) B MCG1+2 (up to 7 connected to one Profinet gateway) E Dupline & Dupline Safe C Siemens S7 PLC 30/09/2016 ENG 6

Compatibility and conformity Approvals CE-marking Approvals UL60950 UL notes: Max ambient temperature: 40 C Equipment must be supplied by a separately certified NEC class 2 (LPS) power unit 30/09/2016 ENG 7

Mode of operation Mode of operation The GS3391 0060 800 is a Profinet gateway with the function as a slave. The module has a 2-port Ethernet switch RJ45 for connection to Profinet. The module is to be mounted in association with the master generator GS3390 0000 800, to which up to 7 master generators can be connected. Each master generator can operate with 128 Dupline addresses. All Dupline signals from the master generator are available on Profinet. By using the GSD file in the PLC configuration tool, the installer can design the functionallity of e.g digital in/ out, analink, mux BCD and Dupline safe signals.* After installation and connection it is possible, by using the mini webserver, to perform tests and run diagnostics on both profinet and the Dupline networks (up to 7 Dupline networks). The Profinet gateway is equipped with LEDs to show communication status. * The GSD file can be downloaded from: Productselection.net 30/09/2016 ENG 8

References Product selection key COPYRIGHT 2016 Content subject to change. Download the PDF: www.productselection.net 30/09/2016 ENG 9