Date Revision Change(s) 29/07/ First version

Similar documents
Date Revision Change(s) First version

Date Revision Change(s) First version Firmware Update 1.5

Date Revision Change(s) 10/10/ First version

PROFINET / ETHERNET Switch PROmesh P9

Indu-Sol GmbH Specialist in fieldbus technologies INBLOX. User Manual. Diagnostic and service tools for PROFIBUS

User Manual Gateway component for EtherNet/IP

Quick Start Guide NETL ink Ethernet Gateways

Revision overview. Revision overview. Date Revision Change(s) First version. Copyright 2015 Indu-Sol GmbH

Installation Manual TH LINK PROFINET. Version: EN Copyright 2014 Softing Industrial Automation GmbH

User manual Gateway component Sercos

HIMatrix Safety-Related Controller Maintenance Manual

Instruction Manual Power Distribution System SVS16-PN-XX

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

SK CU4-PNT-C Part number:

CP ADVANCED. Function

Operating instructions IO-Link master CabinetLine AL19xx

Power Supply System KNX PS640-IP

C.M.I. Control and Monitoring Interface. Quick Guide: Mounting and connection Commissioning. Software Version

Revision History. Version Date Changes Error in PIN description SPI jack Initial version

Operating instructions. Standstill monitor A / / 2011

RMx621. Appendix to the operating manual

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

RMx621 /FML621. Appendix to the operating manual

multisys User manual Technical parameters D2-MSMT-1 Gateway from Modbus TCP to Modbus RTU, serial RS _EDEBDA _EN

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Quick Start Guide WALL IE. Version. 7 en. as of FW

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW

Contents User Manual For PIM

SK CU4-EIP-C Part number:

HARTING scon Introduction and features

Quick Startup Guide. datafeed uagate SI. Version: EN Copyright 2016 Softing Industrial Automation GmbH

DOCUMENTATION UIMip TECHNICAL AND APPLICATION DESCRIPTION. Last modification: 8 September 2017

FIELDBUS TECHNOLOGY ETHERNET- PROFIBUS- INTERFACE PB-XEPI F1144/ 03 INSTALLATION MANUAL

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date:

COMELIT AUDIO PLAYER ART

R70 Ethernet to CAN interface Manual (1.4 EN)

Operating instructions. Switching amplifier DN0210 DN / / 2015

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Industrial Serial Device Server

PHOENIX CONTACT - 10/2009

FG-260. Quick Startup Guide. Gateway between EtherNet/IP and PROFINET with PROFINET Controller functionality. Version: MMA-CA EN

Revision History. Version Date Changes Description of bridge mode settings via web interface Initial version

Manual. Decentralized Drive Control MOVIFIT FDC-SNI Connection to PROFIBUS/DeviceNet with UFF41B Fieldbus Gateway

Operating and mounting instructions

Any device, including routers and hosts, is running an implementation of IP address Host

SK TU4-IOE-M12-C Part Number

IP gateway, MDRC IG/S 1.1, GH Q R0001

EY-EM : Remote I/O module, ecolink

Quick Start Guide. NP290W Turbo Wireless HomePlug

AS-i Safety Output Module, IP20

Arndt & Voß GmbH Elektronik - Meßtechnik

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Contents 1. Summary

DEEP SEA ELECTRONICS PLC

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

Ha-VIS mcon 3000 Next Generation Introduction and features

Serial PROFIBUS Interface

samos PRO Gateways Operating instructions Doc. No. BA Issued: 09/2009 (Rev. A) 2009 Wieland Electric GmbH

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

epowerswitch-8 Power Management Master Slave User's Guide

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

FL MC 2000E (SM40) LC

Operating instructions. Speed monitor D / / 2014

CP BACNET Function

Technical Manual Nova: Cabinet Security Management System (CSMS)

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Gateway configuration manual IP - KNX EK-BE1-TP

Operating Manual FPGA-based High-Speed Micro-PLC

Anybus Wireless Bridge II

SK TU4-PBR Part number:

DOCUMENTATION UIMip. Authors: Manouchehr Ghahramanian Golzar, Peter Hauner. Last Modification:

Connections, displays and operating elements C D

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE

Instruction Manual Power Distribution System SVS16-EN-XX

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

16-Channel Digital Output Module 120Vac/dc

Installation of the PCMeasure Movement Sensor (30114)

SK CU4-PBR-C Part number:

HARTING econ 3000 Introduction and features

BLUE LOG XM / XC. Quick Start Guide. Version

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Operating Instructions Differential Pressure Transducer PS27

Mounting and Operating Instructions (Simple Programming) Art.No..: , published: 10/2003

QUINT-BUFFER/24DC/24DC/40

MINI-PS AC/10-15DC/8

connecdim Gateway G1 Ethernet TCP/IP to DALI

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

to 12a Added Standard and Electrical requirements for UL table 1.1

Technical Information Fieldgate SFG500

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

Transcription:

Revision overview Revision overview Date Revision Change(s) 29/07/2016 0 First version Copyright 2016 Indu-Sol GmbH We reserve the right to amend this document without notice. We continuously work on further developing our products. We reserve the right to make changes to the scope of supply in terms of form, features and technology. No claims can be derived from the specifications, illustrations or descriptions in this documentation. Any kind of reproduction, subsequent editing or translation of this document, as well as excerpts from it, requires the written consent of Indu-Sol GmbH. All rights under copyright law are expressly reserved for Indu-Sol GmbH. Caution! This device may only be put into operation and operated by qualified personnel. Qualified personnel, as referred to in the safety-related information of this manual, are persons who are authorised to put into operation, to earth and to label devices, systems and electrical circuits in accordance with the standards of safety engineering. Intelligent PROFINET Measuring Point ipnma User Manual 3

Contents Contents Revision overview 3 Contents 4 1 General information 5 1.1 Purpose of use 5 1.2 Scope of supply 6 1.3 Safety information 6 2 Device ports and status indicators 7 2.1 Device ports 7 2.2 Installation instructions 8 2.3 Voltage supply 9 2.4 Voltage supply output 9 2.5 Connection to the PROFINET network 9 2.6 WEB INTERFACE 10 3 Setup and operation 11 3.1 Network settings 11 3.2 PROmanage NT 12 4 Device parameters 13 4.1 Update rate 13 4.2 Alarm (high priority / low priority) 13 4.3 Bus device failure 13 4.4 Bus device restart 13 4.5 Jitter 13 4.6 Telegram gaps 14 4.7 Telegram overtakes 14 4.8 Error telegrams 14 4.9 Network load 14 5 Web interface 15 5.1 Support and contact 15 5.2 Firmware update 15 6 Technical data 16 6.1 Technical drawing 16 Intelligent PROFINET Measuring Point ipnma User Manual 4

General information 1 General information Please read this document thoroughly from start to finish before you begin installing the device and putting it into operation. 1.1 Purpose of use The intelligent PROFINET measurement point (ipnma) combines the functions of a PROFINET measurement point with a simple PROFINET network analysis. The following quality parameters are determined: Telegram jitter Telegram gaps Telegram overtakes Network utilisation Update rate Device diagnostics Device failures and restarts Error telegrams In this case, the evaluation of the recorded data does not take place on the device itself, but instead all data are queried and processed by the PROmanage NT software. We recommend installing the ipnma permanently in the network connection between the automation device (controller) and the first switch, because the major part of the communication typically passes through here. Two network jacks (Network P1 and P2) are available for this purpose. For a more detailed network analysis, two monitor jacks (Monitor M1 and M2) are available for feedback-free connection of an analysis tool (e.g. PN-INspektor NT or laptop). No adjustments to the PLC program are required for using the ipnma. It works in an entirely manufacturerindependent way; i.e. the analysis works completely independently of the type of control system and bus nodes. Intelligent PROFINET Measuring Point ipnma User Manual 5

General information 1.2 Scope of supply The scope of supply comprises the following individual parts: ipnma 3-pole plug-in terminal block (power supply) 2-pole plug-in terminal block (Out for measuring device) CD with PROmanage NT software and device manual Please check the contents are complete before putting into operation. 1.3 Safety information Never open the housing of the ipnma. Opening the housing immediately voids any warranty. If you think the device is defective, send it back to the supplier. Intelligent PROFINET Measuring Point ipnma User Manual 6

Device ports and status indicators 2 Device ports and status indicators 2.1 Device ports Monitor X2/M1 IN X2/M2 OUT RJ45 monitor ports X3 - Web interface RJ45 network port Network X1/P1 IN X1/P2 OUT RJ45 PROFINET ports X5 Power supply output X4 Power supply input 24V DC 24V DC + PE Figure 1: Device ports Intelligent PROFINET Measuring Point ipnma User Manual 7

Device ports and status indicators Installation 2.2 Installation instructions The ipnma is installed horizontally inside the cabinet on a 35 mm top-hat rail in accordance with DIN EN 60715. Figure 2: Device installation on top-hat rail Caution: The following distances must be maintained from other modules for correct installation: From left and right: 20 mm From top and bottom: 50 mm The removal of the ipnma is displayed in Fig. 3. Figure 3: Removal Intelligent PROFINET Measuring Point ipnma User Manual 8

Device ports and status indicators 2.3 Voltage supply Operation requires 24 V of external direct current, which is to be connected to the device via the 3-pole plug-in terminal block supplied in the package. The PE contact should be connected to the local PE system. X4 OUT 24V OUT 0V PE DC 24V 0V Ground PE Caution: When connecting, make sure that the polarity is correct. 2.4 Voltage supply output The connection X5 voltage supply Out can be used to provide the voltage supply for PROFINET-INspektor NT or for another measuring device. X5 24V 0V DC 24V Out 0V Ground Out 2.5 Connection to the PROFINET network The ipnma is firmly integrated into the network between the PLC (controller) and the first I/O device or switch for continuous, permanent network analysis. To do this, the device is integrated into the system via the P1 and P2 sockets. Figure 4: Installation ipnma Intelligent PROFINET Measuring Point ipnma User Manual 9

Device ports and status indicators 2.6 WEB INTERFACE The LAN connection X3 provides the Ethernet network connection to the ipnma. This involves a 1000BASE-T RJ45 interface. A standard Ethernet cable is used as a connection cable to a PC or laptop (not included in the scope of supply). Both the evaluation of internally recorded data and the parametrisation of the device are possible through this access point. The ipnma is supplied with the following factory-set network configuration: IP address: 192.168.212.212 Subnet mask: 255.255.255.0 A Web-server function is integrated for access to the device and can be opened with an appropriate standard browser (e.g. Microsoft Internet Explorer from version 10 or Mozilla Firefox from version 11; JavaScript must be activated). You can reach the device's user interface by entering the IP address of the ipnma in the browser's command line. Intelligent PROFINET Measuring Point ipnma User Manual 10

Setup and operation 3 Setup and operation 3.1 Network settings To set the network addressing (IP address, subnet mask, gateway and host name), use the Indu-Sol ServiceTool software (software is included in the scope of supply or can be downloaded at http://www.indusol.com/en/support/downloads/software/). Open the ServiceTool, make sure that the checkmark is set at ipnma and start the scan (see figure 5). After the scan, the found devices should be displayed as shown in figure 6. By clicking on the desired device, the properties of the device are displayed on the right side. In this view, you can change the IP address, subnet, gateway and host name and save the settings. If DHCP is activated by a checkmark, the ipnma gets the IP address, subnet and gateway from an automatic DHCP server. Figure 5 Settings of the ServiceTool Figure 6 Setting options of the ipnma The Indu-Sol ServiceTool functions independently of the IP address setting of the PC used. All that is needed is a network connection. Intelligent PROFINET Measuring Point ipnma User Manual 11

Setup and operation 3.2 PROmanage NT Generally the PROmanage NT software is needed for using the ipnma. This chapter explains the setting up of the ipnma in the PROmanage NT software. For general installation and operation of PROmanage NT, please refer to the PROmanage NT manual (manual included in the scope of supply or by download at http://www.indu-sol.com/en/support/downloads/manuals/). In the first step, you need to start PROmanage NT and log in as Admin. Create a new device in the Analysis and network overview tab by right-clicking (see figure 7). For the automatic scan, select the one by ipnma and start the scan (see figure 8). Finally, checkmark all found ipnmas that should be set up, make the desired settings and then click on Setup (activate the Adopt immediately option). Figure 7: PROmanage NT, create device Figure 8: PROmanage NT, scanning and setting up ipnma Intelligent PROFINET Measuring Point ipnma User Manual 12

Device parameters 4 Device parameters 4.1 Update rate The update rate is a fixed value (specific to each device) set in the controller (e.g. 1 ms) indicating the time between data updates in the controller and the I/O device. The decisive criterion for the actual update rate is the network utilisation on the one hand, and the line depth, i.e. the installed network structure and the number of passing devices. The increasing number of passing devices causes fluctuations in the transit time of telegrams, which are called jitter (see Point 5.5 Jitter). By measuring the update rates, it has to be shown that telegram jitter does not exceed half the update rate upwards or downwards (max. 50 % jitter). 4.2 Alarm (high priority / low priority) Diagnostics messages that appear are sent to the PLC as high-priority or low-priority alarms in PROFINET. The event-based division of these alerts (e.g. the shorting of an ET200S module) is defined by each manufacturer themselves for their devices. Unfortunately, a more precise definition is therefore not possible, since the alarms are classified system and node-specifically. 4.3 Bus device failure In PROFINET node failures are diagnosed by means of the watchdog time of the controller or the node itself. This is determined by the set update time between the controller and node, as well as the number of accepted update cycles with missing I/O data. 4.4 Bus device restart The parameter 'Bus device restart' counts all device restarts that occur. A restart of a bus device occurs after a failure or a system start when a bus device has its parameters set by the control system without any faults and then begins the cyclical data exchange. 4.5 Jitter PROFINET communication is based on maintaining the set update rate of each device with the controller. Positive and negative deviations from this configured update time are referred to as 'jitter' in PROFINET. Jitter of up to 50 % of the configured update time is in an acceptable range. Jitter values that are greater than 50 % suggest network performance problems, device issues or an unfavourable layout of the network structure. Intelligent PROFINET Measuring Point ipnma User Manual 13

Device parameters 4.6 Telegram gaps A telegram gap in PROFINET means the absence of an update time. Telegram gaps are frequently caused by lost telegrams in the network, e.g. by discards or telegram faults or are caused by incorrect firmware versions of devices. In such cases the devices do not pass on a telegram or 'forget' to send off their own telegram. 4.7 Telegram overtakes A telegram overtake may arise in PROFINET if peak loads occur in the switch or I/O device. When circumstances are particularly bad, a new telegram may be sent before an old one in the buffer of the switch. Telegram overtakes indicate excessive utilisation or device malfunctions. 4.8 Error telegrams This entry indicates the number of faulty telegrams detected in the ipnma connection (checksum errors and packet fragments). 4.9 Network load This includes the network load produced by all reports. This is given as a percentage based on the maximum possible load of a cable at 100 Mbit/s. For stable system operation, the network load should not exceed 20 % in new systems. Intelligent PROFINET Measuring Point ipnma User Manual 14

Web interface 5 Web interface 5.1 Support and contact Should you wish to contact us for any reason, further information can be accessed from this page. You can find the manual stored in the download area as a quick aid as well as all important device information. Figure 9: Support and contact 5.2 Firmware update You can perform a firmware update for the ipnma using this function, if required. To do this, the new firmware file is selected and uploaded via the 'Search' button. Following successful installation, triggering a restart is required in the device with the 'Restart' button. Figure 10: Firmware update Intelligent PROFINET Measuring Point ipnma User Manual 15

Technical data 6 Technical data Voltage supply: +24V DC Tolerance: 10% Max. power consumption: 150 ma Max. power loss: 4 W Output voltage: 24 V DC (max. 1A) Dimensions (W x H x D): 105 x 49 x 92 mm, incl. top-hat rail mounting and connector terminals Assembly: TS35 DIN top-hat rail (EN 50022) Weight: 0.345 kg Protection class: IP20 Network port: RJ45 Operating temperature: +5 C to +55 C Storage temperature: -20 C to +70 C Relative air humidity: 10 % to 90 %, non-condensing 6.1 Technical drawing Figure 11: Front view Figure 12: Side view Intelligent PROFINET Measuring Point ipnma User Manual 16