SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

Similar documents
Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

SIMATIC. Process Control System PCS 7 Symantec Endpoint Protection 11.0 Configuration. Using virus scanners 1. Configuration 2. Commissioning Manual

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

Readme SiVArc V14 SP1 Update 6

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

SIMATIC. Process Control System PCS 7 V7.0 SP1 Security Information Note: Setting up antivirus software. Preface. Using virus scanners 2

Siemens Drives & PLCs

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1

Optional package printer driver V1.4

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual

SIMATIC. Industrial PC Microsoft Windows Embedded Standard 7. Safety instructions 1. Initial startup: Commissioning the operating.

PD PA AP How To Configure Maxum II TimeServer Access

SIMATIC. SIMATIC Logon V1.6. Security information 1. Conditions for secure operation of SIMATIC Logon 2. User management and electronic signatures 3

SIMATIC. PCS 7 Process Control System Support and Remote Dialup. Security information 1. Preface 2. Support and Remote Dialup 3.

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

SIMATIC. Process control system PCS 7 PCS 7 - PC Configuration (V9.0 SP1) Security information 1. Preface 2. PC components of a PCS 7 system 3

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0) Security information 1. Preface 2. Basics 3

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

SINETPLAN Siemens Network Planner

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0 Update 1) Security information 1. Preface 2. Basics 3

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

SIMATIC. TIA-Portal SIMATIC Visualization Architect. Security information 1. Basics 2. Installation 3. Elements and basic settings 4

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

SIMATIC. Process Control System PCS 7 SFC Visualization (V9.0 SP2) Security information 1. What's new in SFV? 2. SFC Visualization (SFV) 3

SIMATIC. PCS 7 Process Control System CFC Readme V9.0 SP2 Upd2 (Online) Security information 1. Overview 2. Notes on Installation 3.

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

SIMATIC. PCS 7 process control system PCS 7 Basis Library Readme V9.0 (Online) Security information 1. Overview 2. Notes on installation 3

SIMATIC. Process Control System PCS 7 Software update with utilization of new functions. Security information 1. Preface 2.

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Security information 1. Preface 2. Additional documentation 3

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

SIMATIC. Process Control System PCS 7 Compendium Part D - Operation and Maintenance (V8.2) Security information 1. Preface 2

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

Plant Automation Accelerator 2.1 Readme (Online)

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

B.Data V6.0 Installation SIMATIC. B.Data V6.0 Installation. Introduction. Installing B.Data. Setting up B.Data Web 3

SIMATIC NET. Industrial Remote Communication TeleService TS Gateway. Preface. Application and properties. Installation, commissioning and operation 2

Siemens Spares COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

Plant Automation Accelerator 2.0

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

COMOS. Lifecycle COMOS Walkinside Getting Started. Security information 1. Which functionalities are not covered in this manual? 2

Settings. Prior information notice 1. Introduction to "Settings" 2. User rights in "Settings" 3. Settings interface 4.

SIMATIC HMI. WinCC WinCC Runtime Advanced readme. Security information 1. Installation 2. Runtime 3. System Manual. Online help printout

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect. Preface. Connecting the SINEMA RC Server to the WAN 1

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 6 2. Improvements in Update 3 3. Improvements in Update 2 4

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3

SINUMERIK. MindSphere application Manage MyMachines. Fundamental safety instructions 1. System requirements 2. Product information/technical update 3

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3.

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3

COMOS. Operations Shutdown. Introduction 1. Milestones 2. "Shutdown management" plugin 3. "Quick edit" plugin 4. User interface reference 5

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

Process Historian Administration SIMATIC. Process Historian V8.0 Update 1 Process Historian Administration. Basics 1. Hardware configuration 2

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 2 2. Improvements in Update 1 3

SIMATIC HMI. WinCC V7.4 SP1 WinCC/Audit. WinCC/Audit - Installation Notes 1. WinCC/Audit - Release Notes 2. WinCC/Audit - Documentation.

COMOS. Operations MRO. Introduction 1. Maintenance objects 2. "General maintenance" plugins 3. "Events" plugin 4. "Resources" plugin 5

Transcription:

Security information 1 Preface 2 SIMATIC Configuration 3 Process Control System PCS 7 Configuration Symantec Endpoint Protection V14 Commissioning Manual 03/2018 A5E44395521-AA

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY A5E44395521-AA P 05/2018 Subject to change Copyright Siemens AG 2018. All rights reserved

Table of contents 1 Security information...5 2 Preface...7 3 Configuration...9 3.1 Introduction...9 3.2 Notice...9 3.3 Overview of SEP modules and functions...10 3.4 SEP modules and functions...11 3.4.1 General information...11 3.4.2 Virus and Spyware Protection...11 3.4.3 Intrusion Prevention...13 3.4.4 Host Integrity...13 3.4.5 Application and Device Control...13 3.4.6 LiveUpdate...13 3.4.7 Network Application Monitoring...14 Commissioning Manual, 03/2018, A5E44395521-AA 3

Table of contents 4 Commissioning Manual, 03/2018, A5E44395521-AA

Security information 1 Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines, and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement and continuously maintain a holistic, state-of-the-art industrial security concept. Siemens products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial security measures that may be implemented, please visit: https://www.siemens.com/industrialsecurity Siemens products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under https://www.siemens.com/industrialsecurity. Commissioning Manual, 03/2018, A5E44395521-AA 5

Security information 6 Commissioning Manual, 03/2018, A5E44395521-AA

Preface 2 This documentation describes the settings of Symantec Endpoint Protection (SEP) that need to be changed for use in an industrial plant. The configuration represents an extract of the settings from SEP which were used in the compatibility test with PCS 7 and WinCC. Important information about this whitepaper Note The recommended settings for these virus scanners have been chosen to ensure that the reliable real-time operation of PCS 7 is not adversely affected by the virus scanner software. These recommendations describe the currently known, best-possible compromise between the objective of maximizing the detection and neutralization of virus software and malware and guaranteeing a highly deterministic time behavior of the PCS 7 process control system in all operating phases. If you choose different settings for the virus scanner, this could have negative effects on the real-time behavior. Purpose of the documentation This documentation describes the recommended settings for virus scanner software in combination with PCS 7 and WinCC following the virus scanner installation. Required knowledge This documentation is aimed at persons involved in the engineering, commissioning, and operation of automated systems based on SIMATIC PCS 7 or WinCC. Knowledge of administration and IT techniques for Microsoft Windows operating systems is assumed. In addition, readers should be familiar with the PCS 7 & WinCC security concept. Additional information is available on the Internet at the following address: Security concept (https://support.automation.siemens.com/ww/view/en/60119725) Commissioning Manual, 03/2018, A5E44395521-AA 7

Preface Scope of the documentation This documentation applies to process control systems that are realized with the corresponding PCS 7 or WinCC product version. Note Note that certain virus scanners are only approved for certain product versions. Additional information is available on the Internet at the following address: Compatibility tool (https://www.siemens.com/kompatool) 8 Commissioning Manual, 03/2018, A5E44395521-AA

Configuration 3 3.1 Introduction Symantec Endpoint Protection (SEP) activates additional functions going beyond the traditional virus scanner. The following configurations refer to the centrally managed SEP variant, which is configured using the SEP Manager. The use of a local, non-managed installation is allowed, but is not described. In addition, only an English installation is referred to. All the configurations described are deviations from the default configurations, i.e. any settings not described are not changed. 3.2 Notice The following setting is essential for stable operation of PCS 7. Under "Clients->My Company->Policies->External Communication Settings: Client Submission Send anonymous data to Symantec Client Queries Allow Insight lookups for thread detection When this option is active, the virus scanner attempts to contact Symantec Server directly on the Internet during each file scan. There is a significant delay if the virus scanner cannot reach the server. This makes the stable operation of PCS 7 impossible. All other check boxes under Submission Settings should also be cleared so that no internal information, even if it is anonymous, is sent to Symantec. The other options do not have a negative effect on PCS 7, however. Client Restart Clients should never be restarted automatically. You should disable an automatic restart in two places. Under "Clients->My Company->Policies->General: Restart Settings Restart method No restart Generate a new policy under Install Packages->Client Install Settings: Restart Settings Restart method No restart Commissioning Manual, 03/2018, A5E44395521-AA 9

Configuration 3.3 Overview of SEP modules and functions 3.3 Overview of SEP modules and functions SEP has the following configurable modules that can be configured with policies (available in the SEP under "Policies"): Virus and Spyware Protection Firewall Intrusion Prevention Application and Device Control Host Integrity LiveUpdate Exceptions Additional settings (available in the SEP Manager under Clients > Policies > Locationindependent Policies and Settings): Custom Intrusion Prevention System Lockdown Network Application Monitoring The following modules and settings are recommended and are tested for compatibility for use in a PCS 7 and WinCC environment: Virus and Spyware Protection Intrusion Prevention Device Control Host Integrity (provisional) LiveUpdate Network Application Monitoring The following modules and settings are not recommended and are not checked in the compatibility test: Firewall Only the Windows Firewall is released for use with PCS 7 and WinCC as this is configured automatically depending on the product installed. Application Control This involves computer-specific settings that cannot be checked. Exceptions This involves system-specific settings that cannot be checked. Custom Intrusion Prevention This involves plant-specific settings that cannot be checked. System Lockdown This involves computer-specific settings that cannot be checked. For this reason, no policies should be assigned for these modules and the settings should not be switched "On". Any use of modules and settings which are not recommended is the user's own responsibility. 10 Commissioning Manual, 03/2018, A5E44395521-AA

Configuration 3.4 SEP modules and functions 3.4 SEP modules and functions 3.4.1 General information The options for the policies which have to be configured have no locks next to them. We recommend that you "close" all locks (by clicking on them). This guarantees that the configuration of the virus scan client cannot be changed locally. For the same reason we recommend that you, under Clients-> Policies-> Location-specific Settings-> Client User Interface Control Settings: Click Server Control and Customize and clear all the check boxes except for "Display the client" and "Display the notification area icon". 3.4.2 Virus and Spyware Protection The following configurations relate to a newly created Default Policy. Windows Settings-> Scheduled Scans-> Scans->Administrator-Defined Scans Daily Scheduled Scan Delete Technology-> Auto-Protect-> Actions-> Actions (for "Malicious" and "Security Risks") First action Leave alone (log only) Technology-> Auto-Protect-> Actions-> Remediation Terminate processes automatically Technology-> Auto-Protect-> Actions-> Remediation Stop services automatically Technology-> Auto-Protect-> Notifications-> Notifications Display the Auto-Protect result dialog on the infected computer Technology-> Download Protection-> Download Insight Enable Download Insight to detect potential risk in downloaded files based on file reputation Technology-> Download Protection-> Actions-> Malicious files First action Leave alone (log only) Commissioning Manual, 03/2018, A5E44395521-AA 11

Configuration 3.4 SEP modules and functions Technology-> Download Protection-> Actions-> Unproven files Specify action for unproven files Leave alone (log only) Technology-> Download Protection-> Notifications-> Notifications Display a notification message on the infected computer Technology-> SONAR-> SONAR Settings Enable SONAR Windows Settings-> Email Scans- > Internet Email Auto-Protect-> Scan Details Enable Internet Email Auto-Protect Windows Settings-> Email Scans- > Microsoft Outlook Auto-Protect-> Scan Details Enable Microsoft Outlook Email Auto- Protect Windows Settings-> Email Scans- > Lotus Notes Email Auto-Protect- > Scan Details Enable Lotus Notes Email Auto-Protect Windows Settings-> Advanced Options-> Global Scan Options Display notifications about detections Windows Settings-> Advanced Options-> Quarantine-> General-> When New Virus Definitions Arrive Specify how client computers handle items in the Quarantine Do Nothing Windows Settings-> Advanced Options-> Quarantine-> General-> Quarantined Items Allow client computers to manually submit quarantined items Windows Settings-> Advanced Options-> Quarantine-> Cleanup-> Repaired Files Enable automatic deleting of backup files Windows Settings-> Advanced Options-> Quarantine-> Cleanup-> Backup Files Enable automatic deleting of repaired files 12 Commissioning Manual, 03/2018, A5E44395521-AA

Configuration 3.4 SEP modules and functions Windows Settings-> Advanced Options-> Quarantine-> Cleanup-> Quarantined Files Enable automatic deleting of quarantined files that could not be repaired Windows Settings-> Advanced Options-> Miscellaneous-> Notifications-> Notifications Display error messages with a URL to a solution 3.4.3 Intrusion Prevention The following configurations relate to a newly created Default Policy. No changes required. 3.4.4 Host Integrity Using "Host Integrity" you can monitor the configuration and the behavior of computers. This monitoring has to be configured specifically for the plant. Care should be taken to ensure that no dialog boxes or messages appear on the local client. 3.4.5 Application and Device Control The following configurations relate to a newly created Default Policy. The recommendation is only to use Device Control, in order to prevent the use of USB devices for example. All check boxes should be cleared under "Application Control". 3.4.6 LiveUpdate The following configurations relate to a newly created Default Policy. The settings for reaching the Symantec Update-Server on the internet or a higher-level update server must be adapted to the relevant network topology. Windows Settings-> Schedule-> Live Update Scheduling Enable LiveUpdate Scheduling Windows Settings-> Advanced Settings-> User Settings Allow the user to manually launch LiveUpdate Commissioning Manual, 03/2018, A5E44395521-AA 13

Configuration 3.4 SEP modules and functions Windows Settings-> Advanced Settings-> User Settings Allow the user to modify HTTP, HTTPS, or FTP proxy settings for LiveUpdate 3.4.7 Network Application Monitoring This setting should only be used by administrators with sound network and security knowledge and in systems that have their own security administration. The setting "Network Application Monitoring" is under "Clients-> My Company-> Policies-> Location-independent Policies and Settings-> Network Application Monitoring". The inheritance settings have to be changed here, depending on the company and network topology. Network Application Monitoring Enable network application monitoring Check Network Application Monitoring When an application change is detected Allow and Log 14 Commissioning Manual, 03/2018, A5E44395521-AA