Server Technology, Inc.

Similar documents
Server Technology Inc.

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

Polar PDUs POWER MANAGEMENT

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.

How do I... If you manage a datacenter, we have a solution for you.

Liebert Nform Software

Features and Benefits: Power IQ DCIM Monitoring Solutions

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

MITSUBISHI ELECTRIC DIAMONDLINK V3.0 User s Manual

User Manual. Per Port Monitoring Models

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

02 Why Does My IT Infrastructure Need a UPS?

MGE Galaxy 5000 for emergency lighting and power equipment

Models. Specifications

Frequently Asked Questions (FAQs)

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control.

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

APC APPLICATION NOTE #74

Smart Pro Rack/Tower UPS Intelligent, line-interactive network power management system

Product Brochure. Eaton epdu G3 Managed

Eaton Open Data Centre Solutions. Kari Koli

Product Brochure. Eaton epdu G3 Managed

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

Server Technology, Inc.

Strategies for managing distributed IT environments. Anne-Marie Gignac Vice President Networking Solutions Schneider Electric

The Master Console Center (MCC) automates and enhances data center operations by:

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

THE OFFICIAL TRADE JOURNAL OF BICSI

Top 8 Considerations for Choosing the Right Rack Power Distribution Units to Fit Your Needs

Server Technology Inc.

Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment?

Initial configuration requirements 7. Overview 7 InfraStruXure Manager Setup Wizard 8

Density in the Data Center

Integrate APC Smart UPS

Intelligent Power Software Manage your power easily

Where have all the landlines gone? A white paper from Sensaphone, Inc.

Power Control and Distribution

SmartPro 120V 2.2kVA 1.6kW Line-Interactive UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Rack Power Distribution. Rack power distribution offerings for entry-level networking equipment and high-density server and blade environments

Introducing Server Technology s PRO1 Rack Power Distribution Unit

When an event such as a power failure or a low battery condition occurs,.netpower will notify users via the following ways:

How do I... Sentry Power Manager Rack-Level Data Center Power Monitoring & Management. If you manage a datacenter, we have a solution for you.

Data Center Power: Managing for Energy Efficiency and Cost Savings

SmartOnline Expandable Rack/Tower UPS System On-line, double-conversion protection for mission-critical applications

Model #: SU1500RTXL2U

Power and Cooling Design Guidelines for Network Access Rooms. A White Paper from the Experts in Business-Critical Continuity TM

9910 P18. Advanced power protection for mission-critical System p, System x, Storage and Networking rack products and applications. P18.

Power Monitoring in the Data Centre

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

Sentry Metered, Smart, and Switched High Density 30 Receptacle 208VAC, 3-Phase 30A Products

Intelligent Power Software

SmartPro Tower UPS System Intelligent, line interactive network power management system

84 kw, Tier 3, Direct Expansion, 937 ft 2

Comprehensive Data Center Energy Management Solutions

UPS MANAGEMENT SOFTWARE

Power IQ for econnect

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

UNINTERRUPTIBLE POWER SUPPLIES 9900A >9900AUPS

The -3Ph extension on a product indicates a 3 Phase power product.

Description UPS Management Software

LanSafe UPS Power Management Solution. Network Shutdown

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

1111 West 35th Street Chicago, IL Customer Support: (773) UPS SNMPWEBCARD

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

APC InfraStruXure Solution Overview

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

7011A Series Single-Phase

Product brochure. Eaton 9PXM UPS. A scalable, modular, flexible solution for a wide range of applications. Plan > Grow > Manage

Server Technology White Paper

SmartPro 230V 2.2kVA 1.6kW Line-Interactive UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

Remote Management of Data Center White Space: What to Manage and How? Ashish Moondra Sr. Product Manager Chatsworth Products

Close-coupled cooling

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower, Extended Run, SNMPWEBCARD Option, USB, DB9 Serial

16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Intelligent On-Line UPS

UPS Management Software

PowerJUMP DataShield

TECHNICAL SPECIFICATIONS

Power & Cooling Considerations for Virtualized Environments

15 Ways Belden Helps Reduce Human Error to Improve Uptime

SmartPro 1kVA 800W Line Interactive Sine Wave UPS, SNMPWEBCARD option, 1U Rackmount, USB, RS232, EPO, 120V

APC Symmetra LX. GUIDE SPECIFICATIONS FOR 4kVA-16kVA Uninterruptible Power System

Eaton Power Xpert Gateway Series 2000 Card

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

Veritas NetBackup 6.5 Clients and Agents

cyberm I N D solutions for the digital age cyberm I N D Co-Location

The Importance of Contamination Control at Floor Level. Carlos Mourelle EMEA Director Nov 2018

THE CHALLENGES WITH A COLOCATION ROLL-OUT: And how to simplify the deployment and maintenance of IT equipment at the colocation facility

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Hospital IT and Facilities Special Report Top concerns in the hospital include budget, power requirements

APC APPLICATION NOTE #146

Framework Management Layer User's Guide. SNMP Interface

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

Engineering and Manufacturing Excellence in Data Centre Infrastructure

CRITICAL INFRASTRUCTURE ASSESSMENTS

APC Symmetra RM. Operation Manual

Transcription:

Server Technology, Inc. Smart Load Shedding ensures Uptime White Paper STI-100-004 Server Technology, Inc. 1040 Sandhill Drive Reno, NV 89521 +1 (775) 284-2000 sales@servertech.com www.servertech.com

Smart Load Shedding ensures Uptime INTRODUCTION Uptime or zero down time is the key driving factor in today s data center design and operation with companies measuring downtime in thousands of dollars per minute when a system is not available. Many companies operating Tier III and Tier IV data centers also manage remote sites and colocation facilities that are just as critical as their main location. Managing both remote and co-location facilities requires new innovative solutions to ensure uptime. One such solution is using intelligent Cabinet Power Distribution Units (CDU s) capable of providing Smart Load Shedding capabilities. Smart load shedding allows the operator to load shed based on three key operating parameters; 1) whether the UPS is on battery, 2) the temperature level or 3) the current load. These key parameters allow the user to automatically shed designated, non-critical, devices based on one or all of these conditions ensuring uptime and avoiding damage to the critical devices within the cabinet should a problem occur. There are different approaches on the market today for providing load shedding. This article focuses on the unique advantages of using an intelligent CDU to provide smart load shedding capabilities based on specific critical parameters within the cabinet. This new technology greatly increases uptime and avoids equipment damage. LOAD SHEDDING USING A UPS Load shedding is designed to provide longer operational life by shutting down non-critical devices whenever the UPS goes on battery, allowing the remaining units to operate longer. Typically, load shedding is accomplished by using a UPS with this functionality but this solution has limitations as it does not allow shedding down to the individual outlet level. As one UPS output typically powers multiple devices not allowing it to actively control all of the devices throughout the cabinet. Also, a UPS does not allow load shedding based on the temperature levels in the cabinet or the current load of a specific drop or whip in the cabinet. To have complete control of all of the devices in the cabinet, load shedding using a switched CDU is a more flexible and comprehensive solution. 2

Figure 1 Smart Load Shedding Installation Server Technology, Inc. 2007Server Technology Inc. Smart Load Shedding ensures Uptime 1/18/2007 3

SMART LOAD SHEDDING- BY UPS CONDITION A switched CDU in communication, via SNMP, with one or more UPS s knows when the UPS goes on battery and can automatically shed non-critical devices when this condition occurs (See Figure 1). Since a switched CDU is capable of load shedding down to an individual outlet, complete control is achieved over all the devices in the cabinet. Also, since the CDU knows when a device is going to be shed notification can be sent to a specific device, via a remote shutdown agent, to ensure that a graceful shutdown is achieved before power is cutoff. This is important for devices like servers that may not properly handle a hard reboot and ensures that when power is restored that the server will come back up in good operating condition. These remote shutdown agents are widely used and accepted, work in conjunction with the CDU, and guarantee uptime by shedding less critical devices and ensuring power is available for critical applications. Server Technology has the ability to support Smart Load Shedding for UPS devices from 9 different manufacturers including: APC, Liebert, MGE, Tripp Lite, HP, Minuteman, Mitsubishi, Powerware and Toshiba. In addition, it also supports any manufacturers UPS that supports the Generic RFC 1628 UPS SNMP specification. SMART LOAD SHEDDING- BY TEMPERATURE CONDITION Automatically load shedding devices based on the temperature measurement in the cabinet is the best way to ensure uptime and avoid damage to equipment if the cooling system fails. For example, if cooling is lost in a 5 kw cabinet it can take less than a minute before temperature reaches a critical level. Usually the reaction time of the facility is much longer than the time it takes to damage IT equipment (See Table 1). This is especially true in remote locations or a small number of cabinets installed in a room that relies on a stand alone cooling unit like many of today s IT equipment closets or remote sites. UPS s do not measure temperature and therefore do not provide load shedding based on temperature where switched CDU s easily allow multiple temperature measurements with probes that can be placed exactly where the operator needs to know the temperature reading. Temperature and Humidity information is available several ways on a switched CDU including through an integral web interface and through SNMP traps. Smart Load Shedding allows load shedding based on two different temperature probe measurements located within 10 feet of the CDU. 4

TABLE 1 Time to critical temperature rise W/ft 2 Time 40 10 minutes 100 3 to 5 minutes 200 1 to 3 minutes 300* Less than a minute * 4.5 kw in 15 ft 2, single cabinet in typical Cold Aisle/ Hot Aisle arrangement Note: From Data Center Forum: Power & Cooling Issues, Dr. Robert Sullivan, Dr. Bob, Triton Technology Systems, October 12, 2006 SMART LOAD SHEDDING- BY CDU LOADING Switched CDU s measure the true RMS current level and provide this information via a local LED display, through a web interface and allows the ability to set SNMP traps if specific thresholds are exceeded. RMS current load measurement is a common CDU function that has existed for some time. If an over current condition arises based on a device becoming damaged such as a bad power supply or if a new device has been installed on a circuit exceeding the threshold current level, automatic load shedding is a much better option than running the risk of over loading a branch circuit and losing power to all of the devices associated with that branch. If the branch circuit over current protection devices are circuit breakers and selective coordination is not achieved, then an over current condition will often result in a power loss of all devices on the CDU, as not only will the branch circuit breaker trip but the upstream breakers will trip as well. REMOTE SHUTDOWN AGENT- GRACEFUL SHUTDOWN Event based load shedding i.e. UPS status, current level and temperature, is enhanced by the use of a remote shutdown agent. This agent resides on the server and provides a graceful shutdown by letting the server know that it is going to be shutdown and giving the server enough time to run any scripts or perform other operations that are required before the shutdown occurs. This remote shutdown agent is independent of load shedding and a CDU that is capable of working with a remote shutdown agent can provide a graceful shutdown of servers during a standard remote re-boot, if say a server is locks up, or if the other event based conditions occur. The remote shutdown 5

agent provided by Server Technology Inc., has been honed over 15 years of experience with UPS management and server shutdown software. It is capable of operating with many operating systems including Windows, Linux (Red Hat), SLES, HP-UX, Sun Solaris, Novell Netware and IBM AIX and is currently being used in tens of thousands of installations. AUTORECOVERY- FROM LOAD SHEDDING When the specific threshold is no longer being exceeded or the UPS comes off of battery, a user configured autorecovery can restore power to the previously load shed devices. This feature is fully configurable and it is up to the operator if the system will be allowed to autorecover on none or all of the configured key parameters i.e. temperature, current load, or if the UPS is back on main power. CONCLUSION Even with the best data center design, infrastructure and support, situations will arise that threaten uptime. Implementing switched CDU s with Smart Load Shedding technology ensures that problems like loss of power to the UPS, cooling problems or over current conditions won t affect your ability to continue critical operations. Also, knowing that these controls are active 7 x 24 x 365, and will quickly respond to resolve any problems certainly provides piece of mind. 6