Self Contained - Non Lever Bypass

Similar documents
Self Contained - Non-Jaw Clamping Lever Bypass

Illinois and Northwest Indiana Metering Equipment

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

Square D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions

alid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24

Cooper B-Line RESIDENTIAL SERVICES

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

See also Accessories. Industrial Corrosion Inhibitors Floor Stand Kit PANELITE Enclosure Lights Overview Bulletin: A28X1, A28X2, A28XM.

Meter Enclosure and Equipment Standards

NT-300 & NT-2300 Series Single & Dual Circuit Track System & Accessories

Power-Style QED-2, Series 2 Low Voltage Switchboards

SEQUESTR PREfERREd-CUToUT disconnects Mild STEEl SEQUESTR ExTERnal disconnect PaCkagE, TyPE 12 industry STandaRdS application finish SPECifiCaTionS

PLC Racks IC697CHS782/783

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

UL 508A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E CSA File No : Type 12

HomeWorks Remote Power Feed-Through Panels

CANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential.

Power Mod. Introduction and Contents. Revised 02/18/14

Integration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

SECTION SWITCHBOARDS

Free-Standing Type 12 Enclosures

ASCO SERIES 300 Service Entrance Power Transfer Switch

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Datasheet. Fiber Optic Modular Patch Panel Features

Cord- Mounted Female. Mounted Male. Strain relief clamp # needs to be ordered separately w/cord-mounted connections.

Free-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Fiberglass. Spec L. Non-Metallic. Hinge-Cover with 3-Point Latch or Quick-Release Latches, Type 4X

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

PANELITE ENCLOSURE LIGHTS OVERVIEW

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

NT-2300 Series Dual Circuit Track System & Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS)

920 Remote Control (RC) Switches

Type 4 Disconnect Enclosures

Rack- and Panel-Mount Power Distribution Units (PDUs)

CONCEPT Stainless Steel Wall-Mount Enclosures

Brush installation units made of plastic, quadrangular Assembly instruction

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

ASCO 920 Remote Control (RC) Switches

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading

INSTALLATION INSTRUCTIONS

Rack- and Panel-Mount Power Distribution Units (PDUs)

Quick Start Installation Guide

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

NETXTEND JUICEBOX SERIES Power Transfer Switches

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

Explosionproof Meter Housings

ICS Entrance Management Sign Installation Guide. Version 1.0

Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects

Flat Screen Garage. Table System Planning Guide WORKING FOR YOU

INTERAPID Depth Feet. Brown & Sharpe CENTER FINDER. Model with a flat measuring face. Model with a prismatic measuring face H-16

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

Overvoltage Protection

TRD0359 REV A - Parts Manual 2015 DCN-1363, JAN 09, 2015 SWING-AWAY LATERALS

Meter Breakers. Technical Data. Contents

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

PACSystems RX7i IC698CHS009/119

Innovative POWER Solutions

151 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

Universal MATE-N-LOK Headers for UMNL II Connectors

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT

RL Line/Load Reactors

fine-stranded solid V A mm mm V/8 kv/3 32 No AWG 600 V 30/35 No AWG 600 V 40 6 mm 9 mm aüigotucf+qkw h

SecTER cabinet COOPER POWER SERIES. Sectionalizing Cabinets Catalog Data CA901001EN. General. Optional features

Power-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB FS

Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions

600-Amp Elbow Connectors 600 Series Deadbreak Components

NetXtend JuiceBox Series Integrate Enclosure Solution. Outside Plant for Business-Critical Continuity

B Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

Two Circuit Track Power System IS24 / IS26 / IS28

ACTUATOR. Terminal Blocks. Terminal Blocks. motor. motor. input 24 VDC. input 24 VDC. input 24 VDC RQ60DUM RQ60DUM. Control Circuit.

Specifications. S&C Line-Rupters. For Line and Cable Switching. Outdoor Transmission (115 kv through 230 kv) Conditions of Sale

Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4

9.3. Metering Devices, Protective Relays, Software and Connectivity

Single-Phase Encapsulated

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

U-SERIES SPECIFICATION GUIDE

Sit-to-Stand Workstation

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

60103 Circuit Breaker

Technical Operating Information AC Unit (T150116G100) Replacement Filter No

MICHIGAN DEPARTMENT OF TRANSPORTATION

Safety Mats & Area Guarding

Basketball Shot Clock Set LX2180 Manual

Featured Products - RU Marking Standard on Hoffman brand

10 Pg C1 - C-30.qxp 6/9/ :43 AM Page C1. BELL Weatherproof Boxes, Covers, and Lighting

Square D Homeline Load Centers and Circuit Breakers. Engineered for value

Transcription:

Self Contained - Non 125 & 200 Amp Continuous - 600 VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction Ringless Type 3R construction 16 Ga. galvanneal/galvanized steel 5th jaw provision at nine (9) o clock EN20L43GRST shown open & closed Standards UL 414 listed Complies with ANSI C12.7 Finish ANSI 61 gray painted finish Accessories Replacement sockets hub assemblies Cap setscrew assemblies Horn bypass cap assemblies 5th jaw terminal kits Lug kits Jumper links Closing plates Touch-up paint Part/UPC Catalog Top Service No. of Conductors Ground Prov. Overall Dimensions Knockout Number Number Service Provision Type Terminals Line/Load (Qty) Height Width Depth Layout 125 Amp - Continuous (AIC Rated per Table RL1 on page 42) 78205131419 EN12L41GRST OH Opening 1Ø/3W 4 None #10 G-#2 G 78205158677 EN12L41GRST MS76 OH 125 1Ø/3W 4 None #10 G-#2 G 78205131429 EN12L42GRST UG None 1Ø/3W 4 None #10 G-#2 G 78205131439 EN12L43GRST CAP 1Ø/3W 4 None #10 G-#2 G 200 Amp - Continuous (AIC Rated per Table RL1 on page 42) 78205131451 EN20L41GRST OH Opening 1Ø/3W 4 None #10 G-#2 G 78205131466 EN20L42GRST UG None 1Ø/3W 4 None #10 G-#2 G 78205131487 EN20L43GRST CAP 1Ø/3W 4 None #10 G-#2 G 78205132561 EN20L4RST UG - Bussed Offset None 1Ø/3W 4 None #10 G-#2 G 12 1 /8 8 1 /4 5 1 /4 Fig. 1 12 1 /4 8 1 /4 5 1 /4 Fig. 1 12 1 /4 12 1 /4 5 1 /4 Fig. 2 12 1 /8 12 1 /4 5 1 /4 Fig. 3 15 1 /8 8 1 /4 5 1 /4 Fig. 4 15 1 /8 12 1 /4 5 1 /4 Fig. 5 15 1 /8 12 1 /4 5 1 /4 Fig. 6 15 1 /8 13 1 /4 5 1 /4 Fig. 7 4

Self Contained - Non Knockout Layouts 125 & 200 Amp Continuous - 600 VAC Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Knockouts - Conduit Sizes = 1 2" - 3 8" dia. 2D = 1 1 2" - 1 1 4" = 2-1 1 2" - 1 1 4" - 1 = 2 1 2" - 2-1 1 2" - 1 1 4" = 3-2 1 2" - 2-1 1 2" = Hub Opening (Small) 2D Fig. 7 5

Self Contained - Non-Jaw Clamping 125 Amp Continuous - 600 VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction Ringless Type 3R construction 16 Ga. galvanneal/galvanized steel EC12L41GR1N Standards UL 414 listed Complies with ANSI C12.7 Finish ANSI 61 gray painted finish Accessories Replacement sockets hub assemblies Cap setscrew assemblies 5th jaw terminal kits Lug kits Closing plates Touch-up paint EC12L71GRST Part/UPC Catalog Top Service No. of Conductors Ground Provision Overall Dimensions Knockout Number Number Service Provision Type Terminals Line/Load (Qty) Height Width Depth Layout 125 Amp - Continuous (AIC Rated per Table RL1 on page 42) 78205138492 EC12L41GR1N OH 1Ø/3W 5 NJCLB * Opening #10 G-#2 G 78205158366 EC12L43GR2N CAP 1Ø/3W 5 NJCLB * 78205138491 EC12L71GRST OH Opening 3Ø/4W 7 NJCLB * #10 G-#2 G * lever operates bypass only, non-jaw clamping Includes 5th jaw kit installed at nine (9) o clock, may be relocated at six (6) o clock 19 1 /8 10 1 /4 5 5 /8 Fig. 1 19 1 /8 10 1 /4 5 1 /2 Fig. 2 19 1 /8 10 1 /4 5 5 /8 Fig. 3 6

Self Contained - Non-Jaw Clamping 125 Amp Continuous - 600 VAC Knockout Layouts 1V 1V Fig. 1 Fig. 2 Fig. 3 Knockouts - Conduit Sizes 1V = 1 2" dia. = 1 4" dia. 1Z = 7 16" dia. = 3 4" - 1 2" = 3-2 1 2" - 2-1 1 2" = 2 1 2" - 2-1 1 2" - 1 1 4" - 1 = Hub Opening (Small) 7

Self Contained - 200 Amp Continuous - 600 VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction Ringless Type 3R construction 16 Ga. galvanneal/galvanized steel EL20L53GRST EL20L73GRST Standards UL 414 listed Complies with ANSI C12.7 Finish ANSI 61 gray painted finish Accessories Replacement sockets & H-Base hub assemblies Cap setscrew assemblies 5th jaw terminal kits Lug kits Closing plates Touch-up paint Part/UPC Catalog Top Service No. of Conductors Ground Provision Overall Dimensions Knockout Number Number Service Provision Type Terminals Line/Load (Qty) Height Width Depth Layout 200 Amp - Continuous (AIC Rated per Table RL1 on page 42) 78205138480 EL20L41GR1N OH 1Ø/3W 5 Opening 78205158361 EL20L41GR2N OH H7 1Ø/3W 5 #14-2/0 G 78205138490 EL20L43GRST CAP 1Ø/3W 4 78205158367 EL20L43GR2N H7/ CAP 1Ø/3W 4 ##14-2/0 G 78205158322 EL20L4RST UG Bussed offset None 1Ø/3W 4 #10-2/0 G 78205138479 EL20L4R1N Non-bussed offset H10 1Ø/3W 5 78205132601 EL20L51GRST OH Opening 1Ø/3W or 3Ø/3W 5 78205158364 EL20L51GR2N OH 1Ø/3W 5 Opening or 3Ø/3W 78205132605 EL20L53GRST CAP 1Ø/3W or 3Ø/3W 5 78205138487 EL20L71GRST OH Opening 3Ø/4W 7 78205138483 EL20L71GR1N OH Opening 3Ø/4W 7 78205158359 EL20L71GR2N OH H7 3Ø/4W 7 78205138488 EL20L73GRST CAP 3Ø/4W 7 78205158363 EL20L73GR2N CAP H7 3Ø/4W 7 78205138482 EL20L7R1N Non-bussed offset H10 3Ø/4W 7 8 19 1 /8 10 1 /4 5 5 /8 Fig. 1 19 1 /8 10 1 /4 5 5 /8 Fig. 2 19 1 /8 13 1 /4 5 5 /8 Fig. 3 19 1 /8 13 1 /4 5 1 /2 Fig. 4 19 1 /8 13 1 /4 5 5 /8 Fig. 5 22 1 /8 16 1 /4 6 5 /8 Fig. 6 19 1 /8 10 1 /4 5 5 /8 Fig. 7 19 1 /8 10 1 /4 5 1 /2 Fig. 8 19 1 /8 13 1 /4 5 5 /8 Fig. 3 21 1 /4 10 1 /4 5 5 /8 Fig. 9 21 1 /4 10 1 /4 5 5 /8 Fig. 1 21 1 /8 10 1 /4 5 1 /2 Fig. 2 21 1 /4 13 1 /4 5 5 /8 Fig. 3 21 1 /4 13 1 /4 5 1 /2 Fig. 10 22 1 /8 16 1 /4 6 5 /8 Fig. 6 5th jaw provisions at six (6) o clock and nine (9) o clock Includes 5th jaw kit installed at nine (9) o clock, may be relocated at six (6) o clock Includes 5th jaw kit installed at six (6) o clock, may be relocated at nine (9) o clock

Self Contained - 200 Amp Continuous - 600 VAC Knockout Layouts HH 1V Fig. 1 1V Fig. 2 Fig. 3 Fig. 4 HH 1Z 4J 4J 4J Fig. 5 1Y Fig. 6 Fig. 7 1V Fig. 8 Knockouts - Conduit Sizes 1V Fig. 9 Fig. 10 1V = 1 2" dia. = 1 4" dia. 1Y = 5 16" dia. 1Z = 7 16" dia. = 3 4" - 1 2" = 3-2 1 2" - 2-1 1 2" 4J = 3 1 2" - 3-2 1 2" - 2 = 2 1 2" - 2-1 1 2" - 1 1 4" - 1 = Hub Opening (Small) HH = H Hub Opening (Large) 9

Self Contained - 320 Amp Continuous - 600 VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction Ringless Type 3R construction 16 Ga. galvanneal/galvanized steel EL32T76GRST shown open & closed Standards UL 414 listed Complies with ANSI C12.7 Finish ANSI 61 gray painted finish Accessories Replacement sockets H-Base hub assemblies 5th jaw terminal kits Lug kits Lug/stud landing pads Closing plates Touch-up paint Part/UPC Catalog Top Service No. of Conductors Ground Provision Overall Dimensions Knockout Number Number Service Provision Type Terminals Line/Load (Qty) Height Width Depth Layout 320 Amp - Continuous (AIC Rated per Table RL9 on page 43) 78205140883 EL32T4RST 78205138481 EL32T4R1N 78205138485 EL32T46GRST 78205138484 EL32T7R1N 78205138486 EL32T76GRST 5th jaw provisions at six (6) o clock and nine (9) o clock UG None 1Ø/3W 4 3 /8-16 Stud Bussed Offset 3 /8-16 Stud #10 G-1/0 G H10 1Ø/3W 4 3 /8-16 Stud Non-Bussed Offset 3 /8-16 Stud #10 G-1/0 G H10 1Ø/3W 4 3 /8-16 Stud Bussed Offset 3 /8-16 Stud #10 G-1/0 G H10 3Ø/4W 7 3 /8-16 Stud Non-Bussed Offset 3 /8-16 Stud #10 G-1/0 G H10 3Ø/4W 7 3 /8-16 Stud Bussed Offset 3 /8-16 Stud #10 G-1/0 G 27 5 /8 18 1 /4 7 1 /8 Fig. 1 38 1 /8 18 1 /4 7 1 /8 Fig. 2 36 5 /8 18 1 /4 7 1 /8 Fig. 3 38 1 /8 18 1 /4 7 1 /8 Fig. 2 39 1 /8 20 1 /4 7 1 /8 Fig. 3 10

Self Contained - Knockout Layouts 320 Amp Continuous - 600 VAC HH 1Y Fig. 1 1Y Fig. 2 HH Knockouts - Conduit Sizes 1Y = 5 16" dia. 1Z = 7 16" dia. = 3 4" - 1 2" = 4, 3 1 2" - 3-2 1 2" HH = H Hub Opening (Large) 1Y Fig. 3 11