CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Similar documents
POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

Communication module to connect M-bus devices to POL6xx.xxx controllers.

Climatix programmable controller

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

HVAC&R controller. Climatix C600. POL648.x0, POL688.x0, POL69x.x0

Web interface BACnet/IP

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Resistance measuring module

Compact universal controllers

Digital input modules

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Super universal modules

02/11/2015

Power supply module, bus connection module

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Room unit with PPS2 interface

Zelio Control-modular measurement and control relays 1

IMIO100 IMIO105. DDC controllers. Summary

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Extension module for lighting control

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Programmable controller MCX152V

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

MCX06C Programmable controller

Evo2. Free programmable room controller. Summary

Climatix range. Climatix TM

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Non-communicating room controllers

Island bus expansion module

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

MCX08M2 Programmable controller

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Room unit with PPS2 interface

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Immersion Temperature Sensors

Airflow Pressure Sensor

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

AI531 Analog Input Module

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

mark150s mark150/485s DDC controllers Summary

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

LBVR1718. Description. Features channel paperless recorder

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

APP 700 Technical Specification

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Room automation station

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

General information. Display. Supply voltage

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Logic Controller Millenium Evo

ABB i-bus KNX HCC/S Heating/cooling circuit controller

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display

Logic Controller Millenium Evo

RM35LM33MW liquid level control relay RM35-L V AC/DC

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Control Panel CP600-eCo CP604, CP604-B

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

BACnet/IP Web Interface

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Programmable controller Type MCX06C

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TM200C24R controller M IO relay

RM35LM33MW liquid level control relay RM35-L V AC/DC

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

02/11/2015

TM200CE24T controller M IO transistor Source+ Ethernet

Operating instructions. Standstill monitor A / / 2011

InteliLite MRS17 Click Here to Learn More

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

IntesisBox Modbus Server Panasonic

General information. Display. Supply voltage. Input current. Encoder supply. Output current

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Non-communicating room controllers

Electrical Actuators

TM241C40U controller M IO transistor NPN

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Millenium II +: general characteristics

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

TM241C24T controller M IO transistor PNP

Transcription:

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. 4. Relays Power supply 2. Relays 8. Universal Inputs/ Process Bus (KNX) RS485 (Modbus) Tool (USB) Ethernet Tool (USB)/ HMI (RS485) 2. Analog Inputs 5. Digital Inputs POWER SUPPLY 0 V, AC/DC 24 V Operating voltage AC 24 V ±20 % DC 24 V ±10 % Frequency Power consumption Max. Current consumtion of Controller Max. Current for Extension-Modules 45 65 Hz ca. 15 VA (without Extension modules) 1.8 A (@ AC 24 V) 2.2 A RELAY OUTPUTS Q1...Q6 Relay: type, contact Mono stable, NO contact Contact rating Switching voltage AC 24V 230V (-20%, +10%) Nominal current (res. / ind.) max. AC 4 A/3 A (cos 0.6) Switching current at AC 19 V min. AC 30 ma

2 Datasheet UNIVERSAL I/OS X1,X2 only input X3 X8 universal Configurable Reference potential Contact voltage Overvoltage protection by software terminals max. DC 24 V (SELV) up to 40 V POWERING SENSORS; ACTIVE/RATIO METRIC 2 x 2 outputs +24 V Voltage/current DC 24 V +10%, -25%/2 x 40 ma Reference potential Connection terminals short-circuit-proof ANALOG INPUTS (X1 X8) PT1000 Sensor current Accuracy within the range -40 120 C DC 0...10 V input Input resistance DIGITAL INPUTS (X1 X8) 1.8 ma 0.1 K 0.5 K 1 mv 2 mv 25 mv 50 mv 100 kω 0/1 digital signal (binary) for potential free contacts Sampling voltage/current Contact resistance Delay Pulse frequency ANALOG OUTPUTS (X3 X8) DC 0 10 V output Output current DC 24 V/8 ma max. 200 Ω (closed) min. 50 k Ω (open) 10 ms max. 20 Hz 11 mv 66 mv 95 mv 124 mv 1 ma (short-circuitproof) DIGITAL INPUTS D1 D5 0/1 digital signal (binary) for potential free contacts Sampling voltage/current Contact resistance Delay Pulse frequency ANALOG OUTPUTS (Y1, Y2) DC 0 10 V output Output current INTERFACES Process Bus CE+, CE Process Bus Bus connection 2-wire twisted pair Bus connection / electronics Bus load Bus cable Bus cable length between 2 KNX-Nodes Total length of Bus KNX-Cable Bus power supply via DC 24 V/8 ma max. 200 Ω (closed), min. 50 kωω (open) 10 ms max. 30 Hz 11 mv 66 mv 95 mv 124 mv 2 ma (short-circuitproof) Based on KNX TP1 (refer to KNX Manual) CE+, CE-, not interchangeable Galvanic isolated Max. 5 ma Must be shielded; Please refer to KNX Manual System Specifications Max lenght is 700 m Max lenght of KNX-Cable is 1000 m Internal DPSU with 50 ma nominal current External standard KNX power pack DIGITAL OUTPUTS (X5 X8) DC output for off board loads Switching voltage DC 24 V Switching capacity max. 25 ma

Datasheet 3 THIRD PARTY BUS (RS485 Modbus RTU) A+, B-, REF RS485 (EIA 485) Bus connection/electronics Bus connection 2-wire twisted pair Bus termination (switch by software) USB INTERFACE USB-device-interface Standard cable: Modbus RTU mode 2-wire twisted pair, with shielding Not galvanic isolated A+, B, REF 680 Ω / 120 Ω + 1 nf / 680 Ω Socked, Type B USB-Receptacle, series B Length of cable < 3m BUS LED This LED indicates the status of the integrated modem communication only. It does not indicate the status of the internal communication (to I/O or COM extension modules). This status is visible on the respective extension modules. Modes No Modem connected or LED disabled Modem connected and initialized no communication active Modem connected and communication active Modem connected but errors active (like provider missing, no initialization possible). Off Yellow on Green on Red on LED Status LOCAL SERVICE INTERFACE T-Hi Tool (USB) and HMI (RS485) LED BSP Run/Stop LED Modes Update Modus (Download active or a new BSP, application) Application not loaded Application loaded but not running Application Running BSP error (Software error) Hardware error RJ45 jack, 8 pins LED Status Every second flashing between red and green Yellow flashing with 50 ms on and 1000 ms off Yellow on Green on Red flashing with 2 Hz Red on MODEM SERVICE INTERFACE Connection via plug on the right upper side of the controller Tool and Modem (full Modem Interface) SD CARD RJ45 jack, 8 pins, on the up right side length of cable < 3 m Connection via plug on the right upper side of the controller SD card Slot ETHERNET Slot 128 MB 32 GB Sideways appropriated IP Service Interface T-IP 10/100 MBit (IEEE 802.3U) RJ45 jack, 8 pins

4 Datasheet PERIPHERAL-BUS COM - Extension communication module Connection via plug on the down left side of the controller. SPI-Interface fort the COM-Module connection Low voltage power supply for COM-Module Voltage/current : Board-to-Board Connector (not included) I/O EXTENSION I/O DC 5 V ±10% / max. 1A Short-circuit proof ZEC1,0/10-LPV-3,5 GY35AUC2CI1 Connection via plug on the down right side of the controller Power supply in the controller Ueff = AC 24 V ± 20%, main = 45...65 Hz or U = DC 24 V ± 10% Bus termination selectable Connector (Connectors are not included) Solid wire Stranded wire (twisted or with ferrule) Cable lengths TECHNICAL DATA Real-time clock Buffering with internal backup Buffering with additional Battery Environmental conditions 680 Ω / 120 Ω + 1 nf / 680 Ω Board-to-Board: ZEC 1,0/4-LPV-3,5 C1 Board-to-Wire: ZEC 1,0/4-ST-3,5 C1R1 0.2 1.0 mm² 0.2 1.0 mm² max. 30 m min. 3 days min. 200 days Operation IEC IEC 721-3-3 Temperature 40...70 C Restriction HMI 20 60 C Restriction Process-Bus 25 70 C Restriction with: 2 Com Modules 3 Com Modules Humidity Air pressure 40 65 C 40 60 C < 90% r.h. (no condensation) min. 700 hpa, corresponding to max. 3,000 m above sea level Transport IEC 721-3-2 Temperature 40...70 C Humidity Air pressure Protection < 95% r.h. (no condensation) min. 260 hpa, corresponding to max. 10.000 m above sea level Degree of protection IP 20 to EN 60529 Safety class STANDARDS suitable for use in safety class II plant Product safety: Automatic electrical controls EN 60730-1 Electromagnetic compatibility: Immunity in the industrial sector EN 61000-6-2 Emissions in the domestic sector EN 61000-6-3 CE conformity: EMC directive Low-voltage directive C-tick conformity: In accordance with AU EMC framework UL approvals Signal equipment certified for Canada RoHs compliance GENERAL DATA Dimensions of controller Weight excl. packaging controller without HMI 2004/108/EEC 2006/95/EEC Radio Communications Act 1992 UL916, UL873 CSA C22.2M205 2002/95/EC (Europe) ACPEIP (China) 180 x 110 x 75 mm 487 g Base plastic, Pigeon-blue RAL 5014 Housing plastic, light-grey RAL 7035

Datasheet 5 PLUG-SET The necessary plug-set (connector set) is not by the controller enclosed. (Spring cage, cable side entry). 1 positions or FKCT 2,5/2-ST) 3 positions or FKCT 2,5/2-ST) or FKCT 2,5/3-ST) 1 positions or FKCT 2,5/4-ST) or FKCT 2,5/6-ST) or FKCT 2,5/8-ST) Orange CONNECTION TERMINALS WARNING! Do In order to protect against accidental contact with relay connections at voltages above 42 Veff, the device must be installed in an enclosure (preferably a control panel). It must be impossible to open the enclosure without the aid of a key or tool. AC 230 V cables must be double-insulated against safety extra low-voltage (SELV) cables. DISPOSAL NOTES The controller includes electrical and electronic components and must not be disposed of as domestic waste. Current local legislations must be observed! CONNECTION TERMINALS For IO signals color: gray 110 For communication color: gray For power supply Solid wire Stranded wire (twisted or with ferrule) color: orange 0.5 2.5 mm² 0.5 1.5 mm² 180 45 19 11 Cable lengths in compliance with the load, local regulations and installation documents 47,5 75 110 116