Experience the Latest & Safest in Building Circuit Protection

Similar documents
Experience the Latest & Safest in Building Circuit Protection

Experience the Latest & Safest in Building Circuit Protection

Experience the Latest & Safest in Building Circuit Protection

Surge Protection Devices Type 1+2

TP&N DISTRIBUTION BOARD TYPE B RANGE

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

Surge Protection Devices and Surge Protection Kit

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Lightning and Surge Arresters

Overvoltage Protection Devices

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :

The right solution for every home

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

US Catalog July 2016 SMISSLINE TP

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Experience the Latest & Safest in Building Circuit Protection

Surge & Filter Protection Addressing your industrial power quality needs.

SURGE PROTECTIVE DEVICES

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

Overvoltage Protection Devices

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

Surge Protection for Surveillance Systems

MINI-PS AC/10-15DC/8

Overvoltage Protection Devices

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

L.V. Systems & Solutions

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

RB60 RANGE. Miniature circuit breakers

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Modular surge protective devices

Surge Protection Devices Ex9UE2

Acti 9 Distribution Boards

Lightning Current Equipotential Bonding SPDs

Overvoltage Protection Devices

US CATALOG SMISSLINE TP

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

1492-SP Supplementary Protectors

Type of surge arrester

Reliability in Surge Protection. Photovoltaic Systems.

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

Equipment protection

125A SPN, type A distribution boards Incoming devices Meterpack assemblies Surge protection devices... 34

Thermal-Magnetic Circuit Breaker 4220-T...

ALPHA SIMBOX Small Distribution Boards

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Modular surge protective devices (SPDs) Cat. Nos :

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Plugs & sockets. Industrial plugs and sockets - Scame I-1 4. Industrial switched sockets - Scame I-4 5. Distribution assemblies - Scame I-6

Surge Protective Device

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

US Catalog March Surge protective devices (SPDs) UL range

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Operating Instructions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

ict contactors EN 61095, IEC 1095 Interference

Overvoltage Protection Devices

PRODUCT. Battery Charger

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

Residual Current Devices drcm Digital

Jtec 10kA Miniature Circuit Breaker

Solid-State Contactors

NEW Titan II A & B Distribution Boards

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Modular surge protective devices (SPDs)

Modular surge protective devices (SPDs)

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

EUSR. An Introduction To BS7671 Amendment 3:2015 DESIGNED FOR featuring Consumer Units for Domestic (Household) Premises as per Reg

Overvoltage Protection

Introduction Circuit Protection

Protect Circuit Protection

DSE201, DSE201 M Compact design with enhanced protection

IT power distribution Power distribution units (PDU) Basic. Versions available:

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

High Performance Network Isolator

Defender B Board. Make The Switch

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

Havells Switchgear. Trade Price List. PowerSafe - Commercial Range

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Cirprotec. Specialists in Lightning and Surge Protection for Photovoltaic Systems. Includes new plug-in SPD range and insulation monitoring device

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

KMP A3. Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

3 Design of the electrical installation protection system

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

MOTOR PROTECTION CIRCUIT BREAKERS

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

2 Principle of lightning protection

Transcription:

Experience the Latest & Safest in Building Circuit Protection LIST PRICE w.e.f. 15 th November, 2018

A Distribution Boards CBSD DCORA/Metalica/QVE...08 DBoxx Distribution Boards...09 Metalica Distribution Boards...09 Distribution Board with Lock...09 Phase Selector Distribution Boards...10 Utility Distribution Boards...11 Special Application Distribution Boards...12 B Protection Device Surge Protection Devices...16 Miniature Circuit Breaker (MCB)...17 Residual Current Circuit Breaker (RCCB)...18 Residual Current Circuit Breaker with Overload & Short-CircuitProtection (RCBO)...19 Solutions for Downstream Protection...20 CONTENT A 2 as per Havells Regular Terms & Conditions

C Industrial Plug & Connector Plug...24 Connectors...24 Wall Mounted Socket...24 Panel Socket...24 Interlocking Socket...25 Plug & Socket for Reefer Container...25 Solution with Insulated Plug & Socket...25 D Control & Monitoring Devices Automatic Changeover Devices...30 Time Switch...31 Isolator...31 MCB Changeover...31 Modular Contactors...32 E Photovoltaic Switchgear Range Photovoltaic Disconnector...33 Photovoltaic Fuse Link...33 Accessories...34 B C D as per Havells Regular Terms & Conditions 3

QVE Plus Distribution Boards 4 as per Havells Regular Terms & Conditions

Introducing QVE Plus Distribution Boards AFTER ALL, A PROTECTOR NEEDS TO BE TOUGH. Features - Robust core with smooth curve semantic - Innovative textured finish with optimized play of matte and gloss - Multiple premium colour finishes as per Havells Regular Terms & Conditions 5

Distribution Boards Distribution Boards 6 as per Havells Regular Terms & Conditions

Distribution Boards DBoxx Havells DBoxx Distribution Board is a perfact blend of aesthetics and functionality. The range has been designed with unique features ensuring user safety, convenience, easy handling, and quick, simple installation. Features: Corrosion free Door Push to open, see through glass cover Available in SPN and TPN variant Superior color finish in Mist White and Coin Grey Fitted with masking sheet, raised neutral and earth bar as per Havells Regular Terms & Conditions 7

Distribution Boards Distribution Board Base Common Distribution Board Base Suitable for DCORA / Metalica / QVE Door No. of Ways SPN Cat. No. List Price in ` TPN Cat. No. List Price in ` 4 DSSDBX0240 768.00 DSSDBX0250 1906.00 6 DSSDBX0241 922.00 DSSDBX0251 2210.00 8 DSSDBX0242 1077.00 DSSDBX0252 2838.00 12 DSSDBX0243 1293.00 DSSDBX0253 4028.00 16 DSSDBX0244 1643.00 DCORA SPN DCORA Distribution Board Door No. of Ways Klass Leather SPN Cat. No. List Price in ` Pearl Stone SPN Cat. No. Sepia Rosewood SPN Cat. No. HSN Code - 8538 4 DSSDBX0159 1119.00 DSSDBX0164 1119.00 DSSDBX0169 1065.00 6 DSSDBX0160 1204.00 DSSDBX0165 1204.00 DSSDBX0170 1156.00 8 DSSDBX0161 1247.00 DSSDBX0166 1247.00 DSSDBX0171 1226.00 12 DSSDBX0162 1563.00 DSSDBX0167 1563.00 DSSDBX0172 1520.00 16 DSSDBX0163 2082.00 DSSDBX0168 2082.00 DSSDBX0173 2039.00 TPN DCORA Distribution Board Door (for Single Phase Outgoing) suitable for MCB / RCCB / Isolator as incomer No. of Ways Klass Leather TPN Cat. No. Pearl Stone TPN Cat. No. List Price in ` Sepia Rosewood TPN Cat. No. HSN Code - 8538 4 DSSDBX0204 2638.00 DSSDBX0208 2638.00 DSSDBX0212 2520.00 6 DSSDBX0205 3344.00 DSSDBX0209 3344.00 DSSDBX0213 3205.00 8 DSSDBX0206 4548.00 DSSDBX0210 4548.00 DSSDBX0214 4318.00 12 DSSDBX0207 6495.00 DSSDBX0211 6495.00 DSSDBX0215 6474.00 METALICA awarded in 2016 SPN Metalica Distribution Board Door HSN Code - 8538 No. of Ways Sparkling White SPN Cat. No. Sparkling Gold SPN Cat. No. Silverish Grey SPN Cat. No. 4 DSSDBX0179 DSSDBX0189 DSSDBX0184 792.00 6 DSSDBX0180 DSSDBX0190 DSSDBX0185 835.00 8 DSSDBX0181 DSSDBX0191 DSSDBX0186 926.00 12 DSSDBX0182 DSSDBX0192 DSSDBX0187 1129.00 16 DSSDBX0183 DSSDBX0193 DSSDBX0188 1515.00 TPN Metalica Distribution Board Door (for Single Phase Outgoing) suitable for MCB / RCCB / Isolator as incomer HSN Code - 8538 No. of Ways Sparkling White TPN Cat. No. Sparkling Gold TPN Cat. No. Silverish Grey TPN Cat. No. 4 DSSDBX0220 DSSDBX0228 DSSDBX0224 2055.00 6 DSSDBX0221 DSSDBX0229 DSSDBX0225 2772.00 8 DSSDBX0222 DSSDBX0230 DSSDBX0226 3671.00 12 DSSDBX0223 DSSDBX0231 DSSDBX0227 5575.00 8 as per Havells Regular Terms & Conditions

Distribution Boards QVE SPN QVE Distribution Board Door HSN Code - 8538 No. of Ways Regal Grey Pearl Ivory 4 DSSDBX0194 DSSDBX0199 567.00 6 DSSDBX0195 DSSDBX0200 629.00 8 DSSDBX0196 DSSDBX0201 644.00 12 DSSDBX0197 DSSDBX0202 804.00 16 DSSDBX0198 DSSDBX0203 1139.00 TPN QVE Distribution Board Door (for Single Phase Outgoing) suitable for MCB / RCCB / Isolator as incomer HSN Code - 8538 No. of Ways Regal Grey Pearl Ivory 4 DSSDBX0232 DSSDBX0236 1401.00 6 DSSDBX0233 DSSDBX0237 1906.00 8 DSSDBX0234 DSSDBX0238 2452.00 12 DSSDBX0235 DSSDBX0239 3786.00 DBoxx DB DBOXx SPN & TPN The New Style Statement for your DBs No. of Ways Mist White SPN Cat. No. Coin Grey SPN Cat. No. List Price in ` No. of Ways Mist White TPN Cat. No. Coin Grey TPN Cat. No. List Price in ` 8 DHDNSHCDOW08 DHDNSHCDDW08 1749.00 6 DHDNTHCDOW06 DHDNTHCDDW06 4558.00 12 DHDNSHCDOW12 DHDNSHCDDW12 2067.00 8 DHDNTHCDOW08 DHDNTHCDDW08 5724.00 16 DHDNSHCDOW16 DHDNSHCDDW16 2809.00 12 DHDNTHCDOW12 DHDNTHCDDW12 8321.00 Metalica DB SPN Metalica Distribution Board awarded in 2016 No. of Ways Sparkling White SPN Cat. No. Sparkling Gold SPN Cat. No. Silverish Grey SPN Cat. No. 4 DHDNSHODAW04 DHDNSHODGW04 DHDNSHODDW04 1584.00 6 DHDNSHODAW06 DHDNSHODGW06 DHDNSHODDW06 1793.00 8 DHDNSHODAW08 DHDNSHODGW08 DHDNSHODDW08 2044.00 12 DHDNSHODAW12 DHDNSHODGW12 DHDNSHODDW12 2472.00 16 DHDNSHODAW16 DHDNSHODGW16 DHDNSHODDW16 3221.00 TPN Metalica Distribution Board No. of Ways Sparkling White TPN Cat. No. Sparkling Gold TPN Cat. No. Silverish Grey TPN Cat. No. 4 DHDNTHODAW04 DHDNTHODGW04 DHDNTHODDW04 3997.00 6 DHDNTHODAW06 DHDNTHODGW06 DHDNTHODDW06 5019.00 8 DHDNTHODAW08 DHDNTHODGW08 DHDNTHODDW08 6554.00 12 DHDNTHODAW12 DHDNTHODGW12 DHDNTHODDW12 9673.00 Distribution Boards with Lock Distribution Board With Lock No. of Ways DD DB With Lock SPN Cat. No. No. of Ways DD DB With Lock TPN Cat. No. 8 DHDMSHODCW08 1721.00 4 DHDMTHODCW04 3307.00 12 DHDMSHODCW12 2091.00 6 DHDMTHODCW06 4115.00 - - - 8 DHDMTHODCW08 5295.00 as per Havells Regular Terms & Conditions 9

Distribution Boards Phase Selector Phase Selector (Horizontal - 4 Quadrant) (with rotary switches, duly wired) No. of Ways Rating Regal Grey Cat. No. (DD) I/C 4 40 A DHDSCHDRZ04040 Eight way 7993.00 4 63 A DHDSCHDRZ04063 Eight way 10707.00 6 40 A DHDSCHDRZ06040 Eight way 8858.00 6 63 A DHDSCHDRZ06063 Eight way 11073.00 8 40 A DHDSCHDRZ08040 Eight way 9625.00 8 63 A DHDSCHDRZ08063 Eight way 12408.00 Phase Selector (Vertical) (with rotary switches, duly wired & provision for 8 Way I/C) No. of Ways Rating Regal Grey Cat. No. (DD) Pearl Ivory Cat. No. (DD) 4 40 A DHDSNVDRZ04040 DHDSNVDPZ04040 10510.00 4 63 A DHDSNVDRZ04063 DHDSNVDPZ04063 12408.00 6 40 A DHDSNVDRZ06040 DHDSNVDPZ06040 10638.00 6 63 A DHDSNVDRZ06063 DHDSNVDPZ06063 12535.00 8 40 A DHDSNVDRZ08040 DHDSNVDPZ08040 11772.00 8 63 A DHDSNVDRZ08063 DHDSNVDPZ08063 13166.00 Automatic Phase Selector DB No. of Ways Cat. No. Description 4 DHDANVDRZ04032 Auto Ph-Sel DB 4 Way D/D 32 A 13664.00 6 DHDANVDRZ06032 Auto Ph-Sel DB 6 Way D/D 32 A 16500.00 Phase Selector Enclosure (Vertical) (with rotary switches, duly wired) Rating Regal Grey Cat. No. 40 A DHDATVFS40 4050.00 63 A DHDATVFS63 5883.00 Automatic Phase Selector Unit Rating* ** Cat. No. 32 A* DHDAMHSCZ00032 12498.00 Note: Supplied with 63 A, 4 P MCB as incomer. * Changeover Capacity Per Phase ** 63 A Current Carrying Capacity Per Phase QVE Series DB SP&N No. of Ways O/G Regal Grey Cat. No. (SD) Regal Grey Cat. No. (DD) Pearl Ivory Cat. No. (DD) 4 4 DHDPSHOSRW04 861.00 DHDPSHODRW04 DHDPSHODPW04 1334.00 6 6 DHDPSHOSRW06 953.00 DHDQSHODRW06 DHDQSHODPWO6 1551.00 8 8 DHDPSHOSRW08 1030.00 DHDPSHODRW08 DHDPSHODPW08 1721.00 12 12 DHDPSHOSRW12 1396.00 DHDPSHODRW12 DHDPSHODPW12 2091.00 16 16 DHDPSHOSRW16 1726.00 DHDPSHODRW16 DHDPSHODPW16 2781.00 10 as per Havells Regular Terms & Conditions

Distribution Boards T&PN (for Single Phase Outgoing) suitable for MCB / RCCB / Isolator as incomer No. of Ways I/C+O/G Regal Grey Cat. No. (SD) Regal Grey Cat. No. (DD) Pearl Ivory Cat. No. (DD) 4 4+12 DHDQTHCSRW04 2488.00 DHDNTHCDRW04 DHDNTHCDPW04 3307.00 6 8+18 DHDQTHCSRW06 3024.00 DHDNTHCDRW06 DHDNTHCDPW06 4115.00 8 8+24 DHDQTHCSRW08 3482.00 DHDNTHCDRW08 DHDNTHCDPW08 5295.00 12 8+36 DHDQTHCSRW12 4527.00 DHDNTHCDRW12 DHDNTHCDPW12 7818.00 T&PN (for Single Phase Outgoing) suitable for TPN RCBO as incomer No. of Ways I/C+O/G Regal Grey Cat. No. (SD) Regal Grey Cat. No. (DD) Pearl Ivory Cat. No. (DD) 4 4+12 DHDPTHOSRW04 2718.00 DHDPTHODRW04 DHDPTHODPW04 3617.00 6 8+18 DHDPTHOSRW06 3301.00 DHDPTHODRW06 DHDPTHODPW06 4505.00 8 8+24 DHDPTHOSRW08 3804.00 DHDPTHODRW08 DHDPTHODPW08 5789.00 12 8+36 DHDPTHOSRW12 4955.00 DHDPTHODRW12 DHDPTHODPW12 8539.00 Consumer Units Single Door with Acrylic Window Sheet Steel, Phosphatised, Powder Painted MCB DBs with Bus Bar, Neutral Link, Earth Bar and Din Rail (In accordance with IS 13032, IS 8623, IEC/BS EN 60439-3) No. of Ways Regal Grey Cat. No. 4 DHDMSHOSRA04 1108.00 8 DHDMSHOSRA08 1370.00 12 DHDMSHOSRA12 1761.00 16 DHDMSHOSRA16 2199.00 Single Door Consumer unit without MCB & Isolator No. of Ways Regal Grey Cat. No. 2+4 DHDCSHOSRW04 1151.00 2+8 DHDCSHOSRW08 1536.00 2+12 DHDCSHOSRW12 1852.00 TP&N Vertical TP&N Vertical No. of Ways I/C+O/G Single Door Double Door 4 8+12 DHDMTVOSRW04 6511.00 DHDPTVODRW04 9202.00 8 8+24 DHDMTVOSRW08 9112.00 DHDPTVODRW08 11492.00 12 8+36 DHDMTVOSRW12 11701.00 DHDPTVODRW12 15157.00 as per Havells Regular Terms & Conditions 11

Distribution Boards TP&N Vertical Loadline Loadline DBs are fitted with Bus Bars, Neutral Links, Blanking Plates (without MCCB) No. of Ways Cat. No. Description SINGLE DOOR Note: (i) MCBs & Accessories Should Be Selected And Purchased Separately (ii) For Any Other Configuration Contact Us (iii) For Appropriate MCCB Price, Please see Havells IP List Price SUITABLE FOR TP/FP G FRAME MCCB 4 DHDLVSRWGOFO04 DB LL 4 Way SD VERT W/O MCCB 7801.00 8 DHDLVSRWGOFO08 DB LL 8 Way SD VERT W/O MCCB 9968.00 12 DHDLVSRWGOFO12 DB LL 12 Way SD VERT W/O MCCB 12145.00 DOUBLE DOOR SUITABLE FOR TP/FP G FRAME MCCB 4 DHDLVDRWGOFO04 DB LL 4 Way DD VERT W/O MCCB 9844.00 8 DHDLVDRWGOFO08 DB LL 8 Way DD VERT W/O MCCB 11375.00 12 DHDLVDRWGOFO12 DB LL 12 Way DD VERT W/O MCCB 13418.00 DOUBLE DOOR SUITABLE FOR TP/FP A FRAME MCCB - 250A 4 DHDLVDRWAOFO04 DB LL 4 Way DD VERT W/O MCCB 11375.00 8 DHDLVDRWAOFO08 DB LL 8 Way DD VERT W/O MCCB 14825.00 12 DHDLVDRWAOFO12 DB LL 12 Way DD VERT W/O MCCB 19170.00 7 Segment 7 Segment No. of Ways Regal Grey Cat. No. (DD). I/C 4 DHDMTHDDRW04 Eight way 7924.00 6 DHDMTHDDRW06 Eight way 9459.00 8 DHDMTHDDRW08 Eight way 12134.00 12 DHDMTHDDRW12 Eight way 13311.00 Per Phase Isolation Per Phase Isolation (PPI) Vertical - 4 Tier No. of Ways I/C + O/G Regal Grey Cat. No. (DD). 2+8 4+6+24 DHDPTVPDRW08 10412.00 2+12 4+6+36 DHDPTVPDRW12 12883.00 Per Phase Isolation (PPI) Horizontal- QVE Series suitable for MCB / RCCB / Isolator as incomer No. of Ways I/C + O/G Regal Grey Cat. No. (DD) 2+4 4+6+12 DHDNTHPDRW04 5029.00 2+6 4+6+18 DHDNTHPDRW06 6543.00 2+8 4+6+24 DHDNTHPDRW08 7811.00 Prewired SP&N Prewired (with cable end box) No. of Ways IC/OG DD Cat. No. * 6 2+6 DHDMSHMLRW06 4821.00 8 2+8 DHDMSHMLRW08 5613.00 10 2+10 DHDMSHMLRW10 7111.00 12 2+12 DHDMSHMLRW12 8363.00 16 2+16 DHDMSHMLRW16 9470.00 12 as per Havells Regular Terms & Conditions

Distribution Boards TP&N Prewired No. of Ways IC/OG DD Cat. No. (without cable end box) * DD Cat. No. (with cable end box) * 4 8+12 DHDMTHMKDRA04 9935.00 DHDMTHMLXW04 10321.00 6 8+18 DHDMTHMKDRA06 11974.00 DHDMTHMLXW06 12370.00 8 8+24 DHDMTHMKDRA08 13771.00 DHDMTHMLXW08 14301.00 12 8+36 DHDMTHMKDRA12 16639.00 DHDMTHMLXW12 16644.00 IP 54 SP&N (IP 54) No. of Ways Description Horizontal Cat. No. 4 SPN DB DD 4 Way DHDMSHODRW040002 5987.00 8 SPN DB DD 8 Way DHDMSHODRW080002 6897.00 12 SPN DB DD 12 Way DHDMSHODRW120002 8197.00 TP&N (IP 54) No. of Ways Description Horizontal Cat. No. Vertical Cat. No. 4 TPN DB DD 4 Way DHDMTHODRW040002 9502.00 - - 8 TPN DB DD 8 Way DHDMTHODRW080002 12498.00 DHDMTVODR080002 24471.00 12 TPN DB DD 12 Way DHDMTHODRW120002 17308.00 DHDMTVODR120002 28639.00 TV-TEL SPN TV-TELEPHONE DD DB No. of Ways Description SPN DD Cat. No. 4 SPN 4 Way TV-TELEPHONE DD DB DHDMSHADRW04 2745.00 6 SPN 6 Way TV-TELEPHONE DD DB DHDMSHADRW06 2904.00 8 SPN 8 Way TV-TELEPHONE DD DB DHDMSHADRW08 3159.00 12 SPN 12 Way TV-TELEPHONE DD DB DHDMSHADRW12 3678.00 16 SPN 16 Way TV-TELEPHONE DD DB DHDMSHADRW16 4293.00 TPN TV-TELEPHONE DD DB No. of Ways Description TPN DD Cat. No. 4 TPN 4 Way TV-TELEPHONE DD DB DHDMTHADRW04 6583.00 6 TPN 6 Way TV-TELEPHONE DD DB DHDETHADRW06 7367.00 8 TPN 8 Way TV-TELEPHONE DD DB DHDMTHADRW08 7717.00 12 TPN 12 Way TV-TELEPHONE DD DB DHDMTHADRW12 9985.00 as per Havells Regular Terms & Conditions 13

Protection Devices 14 as per Havells Regular Terms & Conditions

Protection Devices Surge Protection Devices Today s residential, commercial and industrial set-ups are heavily reliant on the continuous and efficient running of electrical and electronic systems. Over-voltage surges are a major cause of failure of these equipment. Such transient over-voltage surges are often generated due to direct/indirect effects of lightning strikes, switching of utility grid or capacitor banks, electrical accidents, turning on/ off of nearby heavy load machines, AC chillers, motors, pumps, circuit-breaker tripping etc. Surges can cause destruction of electronic circuitry components, logic failures and breakdowns. Loss of operation, loss of service, loss of data, and loss of production can be huge and by far higher than the cost of damaged equipment. Long term exposure to lower level transient over-voltages can also lead to premature ageing of equipment. Havells offers a comprehensive range of Surge Protection Devices designed to protect your installation by limiting transient over-voltages and diverting surge currents to ground. Features: Visual & remote end-of-life indicators. Simple, Professional Installation of Arrester Modules High Terminal Capacity - 35 mm 2 for Ease of Installation. Bi-stable Snap-pusher for Easy Installation and Extractioin from DIN-rail. TUV Tested and approved. Range AC SPD s Type 1+2, Type 2 DC SPD s Type 1+2, Type 2 Dataline SPD 6 V, 12 V, 24 V, 48 V Satisfactory operation Cartridge must be replaced Remote Signaling Contact Option to remotely monitor the status of the surge protector. Simplified cabling thanks to a single terminal for monitoring all poles. End of Life Indicator Green shows the satisfactory operation and Red indicates that Cartridge must be replaced. Pluggable Cartridges Faulty cartridges can be replaced without changing the entire SPD. Cartridges can be replaced with mains voltage ON. All cartridges are marked with characteristics for ease of maintenance. Dedicated Protection of the Neutral The 1P+N and 3P+N SPDs with dedicated protection of the neutral pole discharge the common and differential mode overvoltages that may occur in installations with TT and TNS systems, when there is a voltage surge. as per Havells Regular Terms & Conditions 15

Protection Devices EURO II SPD Type 1+2 AC Surge Protection Device Cartridges Order Code Poles Uc (V) In (ka) Iimp (ka) Dataline Surge Protection Device Order Code Un (V) In (ka) Iimp (ka) Imax (ka) Up (V) Remote Signaling 16 DHSDDN1A20006 6 5 5 20 20 No 2766.00 DHSDDN1A20012 12 5 5 20 30 No 2766.00 DHSDDN1A20024 24 5 5 20 40 No 2954.00 DHSDDN1A20048 48 5 5 20 70 No 2954.00 Imax (ka) Up (kv) Remote Signaling DHSAANBC50320 TP+N 320 20 12.5 50 1.5 No 11573.00 DHSAANAC50320 1P+N 320 20 12.5 50 1.5 No 6303.00 DHSAARBC50320 TP+N 320 20 12.5 50 1.5 Yes 11839.00 DHSAARAC50320 1P+N 320 20 12.5 50 1.5 Yes 6560.00 Order Code Pole Uc (V) In (ka) Iimp (ka) Imax (ka) Up (kv) DSSRCX0149 L - N 320 20 12.5 50 1.5 2354.00 DSSRCX0150 N - PE 255 40 12.5 70 1.5 2889.00 Type 2 AC Surge Protection Device Order Code Poles Uc (V) In (ka) Imax (ka) Up (kv) Remote Signaling Type 1+2 Photovoltaic Surge Protection Device Order Code Ucpv (V) In (ka) Iimp (ka) Imax (ka) Up (kv) Remote Signaling HSN Code - 8535 DHSDANCC6012H 1200 Vdc 20 12.5 60 4 No 16842.00 DHSDARCC6012H 1200 Vdc 20 12.5 60 4 Yes 17099.00 DHSDANCB4012H 1200 Vdc 20 6 40 4 No 6955.00 DHSDARCB4012H 1200 Vdc 20 6 40 4 Yes 7207.00 Cartridges Order Code Pole Ucpv (V) In (ka) Iimp (ka) Imax (ka) Up (kv) DSSRCX0154-1200 Vdc 20 6 40 4 1284.00 Order Code Ucpv (V) In (ka) Imax (ka) Up (kv) Remote Signaling DHSA2N1N40320 1P 320 20 40 1.5 No 1910.00 DHSA2N1N40275 1P 275 20 40 1.3 No 1910.00 DHSA2NAN40320 1P+N 320 20 40 1.5 No 3194.00 DHSA2NAN40275 1P+N 275 20 40 1.3 No 3194.00 DHSA2NBN40320 TP+N 320 20 40 1.5 No 5682.00 DHSA2NBN40275 TP+N 275 20 40 1.3 No 5682.00 DHSA2R1N40320 1P 320 20 40 1.5 Yes 2119.00 DHSA2R1N40275 1P 275 20 40 1.3 Yes 2119.00 DHSA2RAN40320 1P+N 320 20 40 1.5 Yes 3398.00 DHSA2RAN40275 1P+N 275 20 40 1.3 Yes 3398.00 DHSA2RBN40320 TP+N 320 20 40 1.5 Yes 5891.00 DHSA2RBN40275 TP+N 275 20 40 1.3 Yes 5891.00 Cartridges Order Code Pole Uc (V) In (ka) Imax (ka) Up (kv) DSSRCX0151 L - N 320 20 40 1.5 963.00 DSSRCX0152 L - N 275 20 40 1.3 963.00 DSSRCX0153 N - PE 255 20 40 1.5 1284.00 Type 2 Photovoltaic Surge Protection Device HSN Code - 8535 DHSD2NCN4012H 1200 Vdc 20 40 4 No 3253.00 DHSD2RCN4012H 1200 Vdc 20 40 4 Yes 3462.00 Cartridges Order Code Pole Ucpv (V) In (ka) Imax (ka) Up (kv) List Price ` DSSRCX0155-1200 Vdc 20 40 4 749.00 * Spare Cartridges Available on Request. as per Havells Regular Terms & Conditions

Protection Devices MCB awarded in 2017 B Series SP MCB (In accordance with IS/IEC 60898-1) 240 V, 50 Hz,10 ka Suitable for lighting and other domestic loads Rating SP Cat. No. 6-32 A DHMGBSPF006-032 200.00 40 A DHMGBSPF040 462.00 C Series MCB (In accordance with IS/IEC 60898-1) 240 V/415 V, 50 Hz, 10 ka Suitable for Motor and other Inductive loads Rating SP Cat. No. SPN Cat. No. DP Cat. No List Price in ` 0.5-5 A DHMGCSPF0x5-005 343.00 DHMGCSNF0x5-005 760.00 DHMGCDPF0x5-005 883.00 6-32 A DHMGCSPF006-032 245.00 DHMGCSNF006-032 660.00 DHMGCDPF006-032 680.00 40 A DHMGCSPF040 479.00 DHMGCSNF040 984.00 DHMGCDPF040 1056.00 50 A DHMGCSPF050 526.00 DHMGCSNF050 1056.00 DHMGCDPF050 1139.00 63 A DHMGCSPF063 526.00 DHMGCSNF063 1056.00 DHMGCDPF063 1139.00 Rating TP Cat. No. TPN Cat. No. FP Cat. No List Price in ` 0.5-5 A DHMGCTPF0x5-005 1135.00 DHMGCTNF0x5-005 1675.00 DHMGCFPF0x5-005 1771.00 6-32 A DHMGCTPF006-032 1056.00 DHMGCTNF006-032 1469.00 DHMGCFPF006-032 1532.00 40 A DHMGCTPF040 1540.00 DHMGCTNF040 2035.00 DHMGCFPF040 2050.00 50 A DHMGCTPF050 1623.00 DHMGCTNF050 2086.00 DHMGCFPF050 2148.00 63 A DHMGCTPF063 1623.00 DHMGCTNF063 2086.00 DHMGCFPF063 2148.00 D Series MCB (In accordance with IEC 60898-1) 240 V/415 V, 50 Hz Suitable for high inrush current loads. Rating SP Cat. No. DP Cat. No. 0.5-5 A DHMGDSPF0x5-005 359.00 DHMGDDPF0x5-005 958.00 6-32 A DHMGDSPF006-032 311.00 DHMGDDPF006-032 782.00 40 A DHMGDSPF040 562.00 DHMGDDPF040 1177.00 50 A DHMGDSPF050 573.00 DHMGDDPF050 1242.00 63 A DHMGDSPF063 573.00 DHMGDDPF063 1242.00 Rating TP Cat. No. FP Cat. No 0.5-5 A DHMGDTPF0x5-005 1466.00 DHMGDFPF0x5-005 1782.00 6-32 A DHMGDTPF006-032 1204.00 DHMGDFPF006-032 1600.00 40 A DHMGDTPF040 1755.00 DHMGDFPF040 2194.00 50 A DHMGDTPF050 1873.00 DHMGDFPF050 2381.00 63 A DHMGDTPF063 1873.00 DHMGDFPF063 2381.00 Higher Rating MCB (80 to 125A) C Series, (In accordance with IEC 60947-2) 240 V/415 V, 50 Hz, 10 ka Rating SP Cat. No. List Price in ` Per Unit DP Cat. No. List Price ` TP Cat. No. List Price ` FP Cat. No. List Price in ` Per Unit 80 A DHMJCSPF080 1921.00 DHMJCDPF080 4200.00 DHMJCTPF080 6132.00 DHMJCFPF080 7360.00 100 A DHMJCSPF100 2151.00 DHMJCDPF100 4313.00 DHMJCTPF100 6453.00 DHMJCFPF100 8040.00 125 A DHMJCSPF125 2360.00 DHMJCDPF125 4928.00 DHMJCTPF125 7260.00 DHMJCFPF125 8534.00 as per Havells Regular Terms & Conditions 17

Protection Devices DC Series MCB For DC Supply, upto 220 V Rating SP Cat. No. DP Cat. No. 0.5-5 A DHMGESPF0x50022-0050022 386.00 DHMGEDPF0x50022-0050022 910.00 6-32 A DHMGESPF0060022-0320022 375.00 DHMGEDPF0060022-0350022 739.00 40 A DHMGESPF0400022 503.00 DHMGEDPF0400022 1054.00 50 A-63 A DHMGESPF0500022-0630022 589.00 DHMGEDPF0500022-0630022 1172.00 DC Series MCB for Railway application Fitted with extended terminals & mounting brackets, Drg. SKEL. 3700 alt-1 & specification No. SPEC/E-12/1/04 Rating SP Cat. No. 0.5-5 A DHMCRSPF0x50013-0050013 418.00 6-35 A DHMCRSPF0060013-0350013 407.00 40 A DHMCRSPF0400013 541.00 50 A-63 A DHMCRSPF0500013-0630013 584.00 Mini MCB C Series (In accordance with IS/IEC 60898-1) 240 V/415 V, 50 Hz, 3 ka Rating SP Cat. No. List Price in ` DP Cat. No. * AC Series also available on request. 6 A-32 A DHMNCSPA006-032 145.00 DHMNCDPA006-032 316.00 RCCB - AC Type RCCB - AC Type (In accordance with IS 12640-1 & IEC 61008-1) 240 V/415 V, 50 Hz with 10 ka short circuit withstand capacity Rating (DP) 30 ma Cat. No. 100 ma Cat. No. 300 ma Cat. No. 16 A DHRGCTDF030016 2771.00 DHRGCTDF100016 2709.00 DHRGCTDF300016 2788.00 25 A DHRGCTDF030025 2771.00 DHRGCTDF100025 2709.00 DHRGCTDF300025 2788.00 32 A DHRGCTDF030032 2792.00 DHRGCTDF100032 2761.00 DHRGCTDF300032 2873.00 40 A DHRGCTDF030040 2792.00 DHRGCTDF100040 2761.00 DHRGCTDF300040 2873.00 63 A DHRGCTDF030063 3657.00 DHRGCTDF100063 3657.00 DHRGCTDF300063 3763.00 Rating (FP) 30 ma Cat. No. 100 ma Cat. No. 300 ma Cat. No. 25 A DHRGCRFF030025 3456.00 DHRGCRFF100025 3343.00 DHRGCRFF300025 3440.00 40 A DHRGCRFF030040 3482.00 DHRGCRFF100040 3405.00 DHRGCRFF300040 3504.00 63 A DHRGCRFF030063 3667.00 DHRGCRFF100063 3667.00 DHRGCRFF300063 3774.00 Higher Rating RCCB Higher Rating RCCB (80-100 A) DP (In accordance with IS 12640-1 & IEC 61008-1) 240 V/415 V, 50 Hz with 10 ka short circuit withstand capacity Rating (DP) 30 ma Cat. No. List Price in ` 100 ma Cat. No. List Price in ` 300 ma Cat. No. 80 A DHRMCMDF030080 5869.00 DHRMCMDF100080 5869.00 DHRMCMDF300080 5869.00 100 A DHRMCMDF030100 5960.00 DHRMCMDF100100 5960.00 DHRMCMDF300100 5960.00 Rating (FP) 30 ma Cat. No. List Price in ` 100 ma Cat. No. List Price in ` 300 ma Cat. No. 80 A DHRMCMFF030080 6164.00 DHRMCMFF100080 6164.00 DHRMCMFF300080 6164.00 100 A DHRMCMFF030100 6324.00 DHRMCMFF100100 6324.00 DHRMCMFF300100 6324.00 RCCB - A Type (In accordance with IS 12640-1 & IEC 61008-1) 240 V/415 V, 50 Hz with 10 ka short circuit withstand capacity Rating (DP) 30 ma Cat. No. List Price in ` 100 ma Cat. No. List Price in ` 300 ma Cat. No. 16 A DHRMAMDF030016 3424.00 DHRMAMDF100016 3307.00 DHRMAMDF300016 3307.00 25 A DHRMAMDF030025 3424.00 DHRMAMDF100025 3307.00 DHRMAMDF300025 3307.00 32 A DHRMAMDF030032 3601.00 DHRMAMDF100032 3521.00 DHRMAMDF300032 3521.00 40 A DHRMAMDF030040 3601.00 DHRMAMDF100040 3521.00 DHRMAMDF300040 3521.00 63 A DHRMAMDF030063 4329.00 DHRMAMDF100063 4195.00 DHRMAMDF300063 4195.00 Rating (FP) 30 ma Cat. No. List Price in ` 100 ma Cat. No. List Price in ` 300 ma Cat. No. 16 A DHRMAMFF030016 4125.00 DHRMAMFF100016 3997.00 DHRMAMFF300016 3997.00 25 A DHRMAMFF030025 4125.00 DHRMAMFF100025 3997.00 DHRMAMFF300025 3997.00 32 A DHRMAMFF030032 4184.00 DHRMAMFF100032 4056.00 DHRMAMFF300032 4056.00 40 A DHRMAMFF030040 4184.00 DHRMAMFF100040 4056.00 DHRMAMFF300040 4056.00 63 A DHRMAMFF030063 4398.00 DHRMAMFF100063 4323.00 DHRMAMFF300063 4323.00 18 as per Havells Regular Terms & Conditions

Protection Devices RCBO RCBO is designed for use in domestic, commercial and industrial distribution systems at the most downstream circuit for ensuring protection from leakage current, short circuit & over load to the user for a particular circuit. In normal use, it is safe to use and free of threat to user as well as to environment. RCBO - A Type (SPN - 2 M) (In accordance with IS 12640-2 & IEC 61009-1) 240 V/415 V, 50 Hz, with 10 ka short circuit capacity Rating (SPN) 30 ma Cat. No. 100 ma Cat. No. 300 ma Cat. No. 6 A DHCEACSN2030006 3542.00 DHCEACSN2100006 3542.00 DHCEACSN2300006 3542.00 10 A DHCEACSN2030010 3542.00 DHCEACSN2100010 3542.00 DHCEACSN2300010 3542.00 16 A DHCEACSN2030016 3542.00 DHCEACSN2100016 3542.00 DHCEACSN2300016 3542.00 20 A DHCEACSN2030020 3542.00 DHCEACSN2100020 3542.00 DHCEACSN2300020 3542.00 25 A DHCEACSN2030025 3542.00 DHCEACSN2100025 3542.00 DHCEACSN2300025 3542.00 32 A DHCEACSN2030032 3542.00 DHCEACSN2100032 3542.00 DHCEACSN2300032 3542.00 40 A DHCEACSN2030040 4366.00 DHCEACSN2100040 4366.00 DHCEACSN2300040 4366.00 RCBO - A Type (TPN - 4 M) (In accordance with IS 12640-2 & IEC 61009-1) 240 V/415 V, 50 Hz, with 10 ka short circuit capacity Rating (TPN) 30 ma Cat. No. 100 ma Cat. No. 300 ma Cat. No. 6 A DHCEACTN4030006 4553.00 DHCEACTN4100006 4553.00 DHCEACTN4300006 4553.00 10 A DHCEACTN4030010 4553.00 DHCEACTN4100010 4553.00 DHCEACTN4300010 4553.00 16 A DHCEACTN4030016 4553.00 DHCEACTN4100016 4553.00 DHCEACTN4300016 4553.00 20 A DHCEACTN4030020 4553.00 DHCEACTN4100020 4553.00 DHCEACTN4300020 4553.00 25 A DHCEACTN4030025 4553.00 DHCEACTN4100025 4553.00 DHCEACTN4300025 4553.00 32 A DHCEACTN4030032 4553.00 DHCEACTN4100032 4553.00 DHCEACTN4300032 4553.00 40 A DHCEACTN4030040 4842.00 DHCEACTN4100040 4842.00 DHCEACTN4300040 4842.00 Electromechanical 2 P RCBOs used as (SPN & 2 P RCBOs) (In accordance with IS 12640-2 & IEC 61009-1) 240 V/415 V, 50 Hz, with 10 ka short circuit capacity Rating (SPN) 30 ma Cat. No. 100 ma Cat. No. 300 ma Cat. No. 16 A DHBMACDP4030016 3638.00 DHBMACDP4100016 3938.00 DHBMACDP4300016 4280.00 25 A DHBMACDP4030025 3638.00 DHBMACDP4100025 3938.00 DHBMACDP4300025 4280.00 32 A DHBMACDP4030032 3745.00 DHBMACDP4100032 4045.00 DHBMACDP4300032 4387.00 40 A DHBMACDP4030040 4120.00 DHBMACDP4100040 4601.00 DHBMACDP4300040 4976.00 6 3A DHBMACDP4030063 5056.00 DHBMACDP4100063 5324.00 DHBMACDP4300063 5591.00 Electromechanical 4P RCBOs used as (TPN & FP RCBOs) (In accordance with IS 12640-2 & IEC 61009-1) 240 V/415 V, 50 Hz, with 10 ka short circuit capacity Rating (TPN) 30 ma Cat. No. 100 ma Cat. No. 300 ma Cat. No. 16 A DHBMACTN8030016 4601.00 DHBMACTN8100016 4949.00 DHBMACTN8300016 5163.00 25 A DHBMACTN8030025 4601.00 DHBMACTN8100025 4949.00 DHBMACTN8300025 5163.00 32 A DHBMACTN8030032 4708.00 DHBMACTN8100032 5056.00 DHBMACTN8300032 5270.00 40 A DHBMACTN8030040 4762.00 DHBMACTN8100040 5340.00 DHBMACTN8300040 5618.00 63 A DHBMACTN8030063 5671.00 DHBMACTN8100063 5918.00 DHBMACTN8300063 5918.00 as per Havells Regular Terms & Conditions 19

Protection Devices 7 Home Segment Safe Havells HomeSafe is ready to use all-in-one device that provides protection to humans from electric shock due to direct or indirect contact as well as provide protection from overload and short circuit. It is a one stop solution to protect appliances as well as humans operating it and it is designed for quick & easy installation. Home Safe SRCD Description Rating DP Cat. No. Havells SRCD WOCP HomeSafe 16 A DHDPACSN2030016 1311.00 Havells SRCD WOCP HomeSafe 20 A DHDPACSN2030020 1311.00 Havells SRCD WOCP HomeSafe 25 A DHDPACSN2030025 1311.00 *WOCP: With Over-Current Protection Home Safe MCB Description DP Cat. No. DP C 06-32 A mini MCB with enclosure DHMPCDPA006-32 361.00 SRCD 7 Segment DBOXx Retro Fit Havells DBOXx SRCD is ready plug & play all-in-one device that provides protection to humans from electric shock due to direct or indirect contact as well as provides protection from overload and short circuit faults. It is designed such that user can easily upgrade his installation by replacing existing socket boxes and get built-in protectioin. SRCD DBOXx (Socket Residual Current Device) Rating Description Cat. Number DBOXX SRCD Protected Socket (With Steel Enclosure) 16 A Havells SRCD WOCP Dboxx Steel Encl DHDDCDP025201603 1990.00 20 A Havells SRCD WOCP Dboxx Steel Encl DHDDCDP025202003 1990.00 25 A Havells SRCD WOCP Dboxx Steel Encl DHDDCDP025202503 1990.00 DBOXX SRCD Protected Socket (With Plastic Enclosure for surface mounting) 16 A Havells SRCD WOCP Dboxx Plastic box DHDBCDP025201603 1926.00 20 A Havells SRCD WOCP Dboxx Plastic box DHDBCDP025202003 1926.00 25 A Havells SRCD WOCP Dboxx Plastic box DHDBCDP025202503 1926.00 DBOXX MCB Protected Socket (Without Enclosure) 16 A Havells SRCD WOCP Dboxx W/O ENCL. DHDACDP025201603 1840.00 20 A Havells SRCD WOCP Dboxx W/O ENCL. DHDACDP025202003 1840.00 25 A Havells SRCD WOCP Dboxx W/O ENCL. DHDACDP025202503 1840.00 *WOCP: With Over-Current Protection DBOXx MCB Protected Socket Rating Cat. No. Description (With Sheet Steel Enclosure) 16 A DHDMCSN0251016 16 A MCB DBOXX COMBO 680.00 20 A DHDMCSN0251020 20 A MCB DBOXX COMBO 680.00 25 A DHDMCSN0251025 25 A MCB DBOXX COMBO 680.00 16 A DHDMCDP0253016 16 A MCB DBOXX COMBO DP 886.00 20 A DHDMCDP0253020 20 A MCB DBOXX COMBO DP 886.00 25 A DHDMCDP0253025 25 A MCB DBOXX COMBO DP 886.00 With Plastic Enclosure (for surface mounting) 16 A DHDTCSN0251016 16 A MCB DBOXX COMBO Plastic 680.00 20 A DHDTCSN0251020 20 A MCB DBOXX COMBO Plastic 680.00 25 A DHDTCSN0251025 25 A MCB DBOXX COMBO Plastic 680.00 Without Enclosure 16 A DHDWCSN0251016 16 A MCB DBOXX COMBO W/O ENCL. 626.00 20 A DHDWCSN0251020 20 A MCB DBOXX COMBO W/O ENCL. 626.00 25 A DHDWCSN0251025 25 A MCB DBOXX COMBO W/O ENCL 626.00 16 A DHDWCM30251016 16 A MCB DBOXX COMBO 3M W/O ENCL. 594.00 20 A DHDWCM30251020 20 A MCB DBOXX COMBO 3M W/O ENCL. 594.00 25 A DHDWCM30251025 25 A MCB DBOXX COMBO 3M W/O ENCL 594.00 20 as per Havells Regular Terms & Conditions

Protection Devices DBOXx MCB Protected Power Unit Rating Description Cat. No. 16 A-25 A 16 A-25 A MCB Protected Power Unit DHDUCDP0253016-25 1156.00 Plug & Socket Plug & Socket Box with Plastic Plug Rating Description Cat. No. 20 A Plug & Socket 20 A DP With Plastic Plug DHDPHDP020 610.00 20 A Plug & Socket 20 A SPN With Plastic Plug DHDPHSN020 610.00 DBOXx Plug and Socket Rating Description Cat. No. 20 A Plug & Socket 20 A DP With Plastic Cover DHDCUDP020 947.00 20 A Plug & Socket 20 A SPN With Plastic Cover DHDCUSN020 947.00 Plug & Socket Board SP&N enclosure with 2 pole and Earth Metal Plug & Socket for incorporating 10 A / 20 A SPN / DP MCB Rating Cat. No. TP&N enclosure with 3 pole and Earth Metal Plug & Socket for Incorporating TP MCB Rating Cat. No. 20 A DHDPUSN020/DHDPUDP020 947.00 30 A DHDPUTN020 / DHDPUTN030 2900.00 MCB Enclosure MCB Enclosure (Cutout) Sheet Steel, Phosphatised, Powder Painted MCB DBs with Din Rail (In accordance with IS 13032, IS 8623, IEC/BS EN 60439-3) Plastic No. of Ways Cat. No. Sheet Steel No. of Ways Cat. No. 2 DHDEPDP 175.00 2 DHDESDP 297.00 4 DHDEPFP 260.00 4 DHDESFP 361.00 as per Havells Regular Terms & Conditions 21

Industrial Plug & Connector 22 as per Havells Regular Terms & Conditions

Industrial Plug & Connector Industrial plug and socket are used to provide power in industrial environments and areas exposed to corrosive chemicals, extremes of weather and rough use with high demands on safety, reliability and durability. Havells provides a comprehensive range of plug and socket to suit all environments & applications, manufactured to the highest quality and having robust ergonomic design. Havells industrial plug & socket range adopts preventing incorrect insertion design and its high grade thermoplastic material ensures good electric insulation, high impact resistance, dustproof, damp proof and watertight connections. Nickel plated contacts provide better corrosion resistance in aggressive environments and at high degrees of air humidity. HAVELLS provides IP 44 range of plug & socket, protected against splashing and spraying of water, and IP 67 weatherproof plug and socket range that can withstand temporary immersion in water. Some typical applications are highlighted below. Application Agriculture Chemical industry Construction sites and shipyards Sports complexes and other places of public entertainment, TV and film studios Food industry Heavy industry Light industry Installations for IT centres Ports Airports Water treatment plants IP-44 Mobile or portable equipment or appliances used or stored on sheltered premises. Indoors on premises for storage and maintenance purposes where connections are not exposed to the risk of immersion or chemicals. On covered construction sites sheltered against weathering but exposed to splashing with water. On sheltered premises protected against the weather, though exposed to splashing, without high connected loads. In sheltered locations, on indoor premises used for storage and maintenance. In sheltered warehouses, maintenance workshops, assembly and moulding areas. Locations without high humidity or ambient pollution serving for assembly, moulding, maintenance and storage For electrical connections executed above floor level. In sheltered locations such as docks, repair shops, offices, etc. In sheltered locations, hangars, repair shops, warehouses. Indoor use in repair shops, etc. IP-67 Outdoor installation of pumping, ventilation, drying equipment. On premises without risk of explosions but where the connections are exposed to chemicals and subject to possible immersion. On outdoor construction sites where the connections are left on damp ground exposed to freezing, dust and weathering. Outdoor connections exposed to rain, snow, mud, freezing and other critical weather conditions. Where mated safety is required. Where high voltage for lighting installations, T.V. and audio are foreseen. In locations subject to washing by hosing down and where connections are subject to heavy duty. In rolling mills, foundries, blast furnaces, etc., where the connections are exposed to dust, metallic shavings, coolants and are subject to vibrations and impact. On premises subject to cleaning by means of chemical solvents. Also where heavy loads require high safety in connections. For electrical connections under raised floors with risk of immersion. Where heavy loads require high safety in connections. Quays, docks, piers, etc. where there is risk of high waves and partial flooding. Outdoors for connection between mobile or portable appliances and aircraft. In all locations with risk of flooding and for outdoor use with pumps, aeration and ventilation systems. as per Havells Regular Terms & Conditions 23

Industrial Plug & Connector Industrial Plug Industrial Plug Rating Poles Code Type Earth-Contact position Std. / Master Packing (No. of Unit/s) 16 A 2P+E DHQBA63016 IP44 6 h 4 N 375.00 32 A 2P+E DHQBA63032 IP44 6 h 4 N 525.00 16 A 3P+N+E DHQBA65016 IP44 6 h 4 N 455.00 32 A 3P+N+E DHQBA65032 IP44 6 h 4 N 680.00 16 A 2P+E DHQBB63016 IP67 6 h 4 N 642.00 32 A 2P+E DHQBB63032 IP67 6 h 4 N 1012.00 16 A 3P+N+E DHQBB65016 IP67 6 h 4 N 878.00 32 A 3P+N+E DHQBB65032 IP67 6 h 2 N 1049.00 63 A 2P+E DHQBB63063 IP67 6 h 1 N 2247.00 63 A 3P+N+E DHQBB65063 IP67 6 h 1 N 2665.00 Industrial Connector Industrial Connector Rating Poles Code Type Earth-Contact position Std. / Master Packing (No. of Unit/s) 16 A 2P+E DHQDA63016 IP44 6 h 4 N 493.00 32 A 2P+E DHQDA63032 IP44 6 h 4 N 621.00 16 A 3P+N+E DHQDA65016 IP44 6 h 4 N 589.00 32 A 3P+N+E DHQDA65032 IP44 6 h 4 N 792.00 16 A 2P+E DHQDB63016 IP67 6 h 4 N 867.00 32 A 2P+E DHQDB63032 IP67 6 h 4 N 1210.00 16 A 3P+N+E DHQDB65016 IP67 6 h 4 N 1156.00 32 A 3P+N+E DHQDB65032 IP67 6 h 2 N 1359.00 63 A 3P+N+E DHQDB65063 IP67 6 h 1 N 3098.00 Industrial Wall Mounted Socket Industrial Wall Mounted Socket Rating Poles Code Type Earth-Contact position Std. / Master Packing (No. of Unit/s) 16 A 2P+E DHQSA63016 IP44 6 h 2 N 578.00 32 A 2P+E DHQSA63032 IP44 6 h 2 N 792.00 16 A 3P+N+E DHQSA65016 IP44 6 h 2 N 642.00 32 A 3P+N+E DHQSA65032 IP44 6 h 2 N 830.00 16 A 2P+E DHQSB63016 IP67 6 h 2 N 958.00 32 A 2P+E DHQSB63032 IP67 6 h 2 N 1338.00 16 A 3P+N+E DHQSB65016 IP67 6 h 2 N 1215.00 32 A 3P+N+E DHQSB65032 IP67 6 h 2 N 1456.00 63 A 3P+N+E DHQSB65063 IP67 6 h 1 N 3558.00 Industrial Panel Socket Industrial Panel Socket Rating Poles Code Type Earth-Contact position Std. / Master Packing (No. of Unit/s) 16 A 2P+E DHQCA63016 IP44 6 h 6 N 343.00 32 A 2P+E DHQCA63032 IP44 6 h 4 N 594.00 16 A 3P+N+E DHQCA65016 IP44 6 h 4 N 557.00 32 A 3P+N+E DHQCA65032 IP44 6 h 4 N 675.00 16 A 2P+E DHQCB63016 IP67 6 h 4 N 885.00 32 A 2P+E DHQCB63032 IP67 6 h 4 N 803.00 16 A 3P+N+E DHQCB65016 IP67 6 h 4 N 798.00 32 A 3P+N+E DHQCB65032 IP67 6 h 3 N 1044.00 63 A 3P+N+E DHQCB65063 IP67 6 h 1 N 2782.00 24 as per Havells Regular Terms & Conditions

Industrial Plug & Connector Industrial Plug & Socket for Reefer Container Industrial Plug & Socket for Reefer Container Category Rating Poles Code Type Earth-Contact position Std. / Master Packing (No. of Unit/s) Panel Socket 32 A 3P+E DHQCB34032 IP67 3 h 4 N 1044.00 Plug 32 A 3P+E DHQBB34032 IP67 3 h 4 N 1049.00 Connector 32 A 3P+E DHQDB34032 IP67 3 h 4 N 1359.00 Wall mounted socket 32 A 3P+E DHQSB34032 IP67 3 h 2 N 1456.00 Interlock socket 32 A 3P+E DHQWB34032 IP67 3 h 1 N 6404.00 Industrial Interlocking Socket Industrial Interlocking Socket Rating Poles Code Type Earth-Contact position Std. / Master Packing (No. of Unit/s) 16 A 2P+E DHQIA63016 IP44 6 h 1 N 4783.00 32 A 2P+E DHQIA63032 IP44 6 h 1 N 6132.00 16 A 3P+N+E DHQIA65016 IP44 6 h 1 N 6741.00 32 A 3P+N+E DHQIA65032 IP44 6 h 1 N 7239.00 16 A 2P+E DHQWB63016 IP67 6 h 1 N 4639.00 32 A 2P+E DHQWB63032 IP67 6 h 1 N 6404.00 16 A 3P+N+E DHQWB65016 IP67 6 h 1 N 6939.00 32 A 3P+N+E DHQWB65032 IP67 6 h 1 N 7704.00 Industrial Interlocking Socket with MCB Provision Rating Poles Code Type Earth-Contact position *MCB & Plug to be bought seperately. Std. / Master Packing (No. of Unit/s) 63 A 2P+E DHQEB63063 IP67 6 h 1 N 11770.00* 63 A 3P+N+E DHQEB65063 IP67 6 h 1 N 12305.00* Solution with Insulated Plug & Socket Solution with Insulated Plug & Socket Rating Poles Code Type Earth-Contact position Note: MCB to be bought seperately. Std. / Master Packing (No. of Unit/s) 16 A 2P+E DHDPBDP016 IP40 6 h 1 N 1301.00 16 A 3P+N+E DHDPBTN016 IP40 6 h 1 N 1568.00 32 A 2P+E DHDPBDP032 IP40 6 h 1 N 1782.00 32 A 3P+N+E DHDPBTN032 IP40 6 h 1 N 2012.00 as per Havells Regular Terms & Conditions 25

Havells Time Switch 26 as per Havells Regular Terms & Conditions

Advance Range of Time Switch as per Havells Regular Terms & Conditions 27

Control & Monitoring Devices 28 as per Havells Regular Terms & Conditions

Control & Monitoring Devices Modular Contractor AUTOMATIC MODULAR CONTACTOR In automatic contactors the switching operation depends solely on the availability of coil supply. When coil supply is provided sufficient electromagnetic force is generated for closing the NO main contacts or opening the NC main contacts. In the absence of coil supply, the contacts revert to their original position. AUTOMATIC MODULAR CONTACTOR WITH MANUAL OVERRIDE Automatic Contactors with manual override knob have a manual over-ride switch to select between three function modes and 4 operating positions. Automatic Mode: It is the normal operating mode i.e. Contactor is operational (ON) when Coil voltage is applied and vice versa. ON Mode : - Temporary ON position: When manual knob is not locked at ON position the main contacts remain ON as long as coil supply is absent. When oil supply becomes available, the contactor automatically reverts to automatic mode. - Permanent ON position: Here, the contactor is operational (ON) irrespective of the availability of coil supply. OFF Mode: Here, the contactor is shutdown irrespective of the availability of coil supply. Manual override option provides customers with the following features: - Functional test prior to start/commissioning - High degree of safety and availability in case of automation system failure - Testing or repairs can be carried out safely, reliably and quickly without interrupting other automatic functions. - Force ON and Force OFF feature allows user to run high energy load during low teriff periods only, thereby over-ruling the normal operation of contactor at all times. as per Havells Regular Terms & Conditions 29

Control & Monitoring Devices ACCL 3 Module SPN ACCL (Automatic Source Changeover with Current Limiter) Mains Rating Gen Rating Product Code Description SPN 30 (6000 W) SPN 1.5 (300 W) DHADOSN301X 30 A/1.5 A ACCL W/O GEN START/STOP 1691.00 SPN 30 (6000 W) SPN 2.5 (500 W) DHADOSN302X 30 A/2.5 A ACCL W/O GEN START/STOP 1691.00 SPN 30 (6000 W) SPN 3 (600 W) DHADOSN3003 30 A/03 A ACCL W/O GEN START/STOP 1691.00 SPN 30 (6000 W) SPN 4 (800 W) DHADOSN3004 30 A/4 A ACCL W/O GEN START/STOP 1691.00 SPN 30 (6000 W) SPN 5 (1000 W) DHADOSN3005 30 A/5 A ACCL W/O GEN START/STOP 1691.00 SPN 30 (6000 W) SPN 6 (1200 W) DHADOSN3006 30 A/06 A ACCL W/O GEN START/STOP 1691.00 SPN 30 (6000 W) SPN 9 (1800 W) DHADOSN3009 30 A/09 A ACCL W/O GEN START/STOP 1691.00 SPN 30 (6000 W) SPN 12 (2400 W) DHADOSN3012 30 A/12 A ACCL W/O GEN START/STOP 1691.00 SPN 30 (6000 W) SPN 15 (3000 W) DHADOSN3015 30 A/15 A ACCL W/O GEN START/STOP 1691.00 SPN 30 (6000 W) SPN 20 (4000 W) DHADOSN3020 30 A/20 A ACCL W/O GEN START/STOP 1691.00 Premium SPN ACCL (Automatic Source Changeover with Current Limiter) Gen Rating Description Cat. No. w/o GEN Start/Stop TPN ACCL (TPN/TPN) (Automatic Source Changeover with Current Limiter) Gen Rating Description Cat. No. Cat. No. with GEN Start/Stop Cat. No. with GEN Start/Stop SPN 1.5 (300 W) 30 A/1.5 A ACCL DHABOSN301X 2089.00 SPN 2.5 (500 W) 30 A/2.5 A ACCL DHABOSN302X 2089.00 SPN 3 (600 W) 30 A/03 A ACCL DHABOSN3003 2089.00 DHABWSN3003 2349.00 SPN 4 (800 W) 30 A/4 A ACCL DHABOSN3004 2089.00 SPN 5 (1000 W) 30 A/5 A ACCL DHABOSN3005 2089.00 SPN 6 (1200 W) 30 A/06 A ACCL DHABOSN3006 2089.00 DHABWSN3006 2349.00 SPN 9 (1800 W) 30 A/09 A ACCL DHABOSN3009 2089.00 DHABWSN3009 2349.00 SPN 12 (2400 W) 30 A/12 A ACCL DHABOSN3012 2089.00 DHABWSN3012 2349.00 SPN 15 (3000 W) 30 A/15 A ACCL DHABOSN3015 2089.00 DHABWSN3015 2349.00 SPN 20 (4000 W) 30 A/20 A ACCL DHABOSN3020 2089.00 DHABWSN3020 2349.00 Automatic Changeover Gen Rating Description Cat. No. w/o GEN Start/Stop TPN ACCL (TPN/SPN) (Automatic Source Changeover with Current Limiter) Gen Rating Description Cat. No. Cat. No. with GEN Start/Stop Cat. No. with GEN Start/Stop SPN 30 (6000 W) SPN 30 (6000 W) DHAAOSN3030 1972.00 DHAAWSN3030 2178.00 SPN 63 (12600 W) SPN 63 (12600 W) DHAAOSN6363 4638.00 DHAAWSN6363 4799.00 20 A 40 A/20 A TPN/SPN ACCL DHACOTN4020 12466.00 DHACWTN4020 12776.00 25 A 40 A/25 A TPN/SPN ACCL DHACOTN4025 12466.00 DHACWTN4025 12776.00 30 A 40 A/30 A TPN/SPN ACCL DHACOTN4030 12466.00 DHACWTN4030 12776.00 40 A 40 A/40 A TPN/SPN ACCL DHACOTN4040 12466.00 DHACWTN4040 12776.00 20 A 63 A/20 A TPN/SPN ACCL DHACOTN6320 18554.00 DHACWTN6320 18859.00 25 A 63 A/25 A TPN/SPN ACCL DHACOTN6325 18554.00 DHACWTN6325 18859.00 30 A 63 A/30 A TPN/SPN ACCL DHACOTN6330 18554.00 DHACWTN6330 18859.00 40 A 63 A/40 A TPN/SPN ACCL DHACOTN6340 18554.00 DHACWTN6340 18859.00 63 A 80 A/63 A TPN/SPN ACCL DHACOTN8063 30415.00 20 A 40 A/20 A TPN/TPN ACCL DHACOTT4020 12776.00 DHACWTT4020 13381.00 25 A 40 A/25 A TPN/TPN ACCL DHACOTT4025 12776.00 DHACWTT4025 13381.00 30 A 40 A/30 A TPN/TPN ACCL DHACOTT4030 12776.00 DHACWTT4030 13381.00 40 A 40 A/40 A TPN/TPN ACCL DHACOTT4040 12776.00 DHACWTT4040 13381.00 20 A 63 A/20 A TPN/TPN ACCL DHACOTT6320 18859.00 DHACWTT6320 19464.00 25 A 63 A/25 A TPN/TPN ACCL DHACOTT6325 18859.00 DHACWTT6325 19464.00 30 A 63 A/30 A TPN/TPN ACCL DHACOTT6330 18859.00 DHACWTT6330 19464.00 40 A 63 A/40 A TPN/TPN ACCL DHACOTT6340 18859.00 DHACWTT6340 19464.00 63 A 63 A/63 A TPN/TPN ACCL DHACOTT6363 25857.00 63 A 80 A/63 A TPN/TPN ACCL DHACOTT8063 31646.00 30 as per Havells Regular Terms & Conditions

Control & Monitoring Devices Time Switch Time switches are used in residential, commercial and industrial premises to improve comfort and save energy by switching loads automatically as per real time. Havells offers a variety of time switches to precisely meet the requirements of different applications. The range offers several feature benefits such as different options of minimum switching time, internal battery to enable the timing function in case of power failure, daily and weekly versions, simple and compact design. Time Switch Description Cat. No. 24 Hour Analog Time Switch (SST* - 15 min) DHTED15016 2633.00 24 Hour Analog Time Switch (SST* - 30 min) DHTED30016 2381.00 Programmable Time Switch 24 Hour (SST - 15 min) DHTDD15016 2526.00 Digital Weekly Programmable Time Switch (SST - 1 min) DHTAW01016 2365.00 Astronomical Weekly Programmable Time Switch (SST - 1 min) DHTBW01006 2729.00 Staircase Light Time Switch (Adjustment Range 0.5-20 min) DHTCNX5016 1263.00 * Shortest Switching Time HSN Code - 9107 MCB Isolator MCB ISOLATOR (Switching Devices) MCB Isolators (AC-22 A, In accordance with IS/IEC 60947-3) 240 V/415 V, 50 Hz Rating SP Cat. No. DP Cat. No. 40 A DHMGISPX040 300.00 DHMGIDPX040 407.00 63 A DHMGISPX063 348.00 DHMGIDPX063 526.00 80 A DHMGIDPX080 705.00 100 A DHMGIDPX100 705.00 125 A DHMGIDPX125 771.00 Rating TP Cat. No. FP Cat. No 40 A DHMGITPX040 856.00 DHMGIFPX040 969.00 63 A DHMGITPX063 969.00 DHMGIFPX063 969.00 80 A DHMGITPX080 1145.00 DHMGIFPX080 1267.00 100 A DHMGITPX100 1145.00 DHMGIFPX100 1267.00 125 A DHMGITPX125 1177.00 DHMGIFPX125 1389.00 Mini MCB Isolator Mini DP Isolator In accordance with IS/IEC 60947-3, 240 V/415 V, 50 Hz Rating DP Cat. No. List Price in ` 40 A DHMNIDPX040 382.00 MCB Changeover Two Way Centre Off Changeover Switch For Dual Electricity Supply Management (In accordance with IS/IEC 60947-3) Rating DP Cat. No. FP Cat. No. 25 A DHMGODPX025 1272.00 DHMGOFPX025 2226.00 40 A DHMGODPX040 1545.00 DHMGOFPX040 2862.00 63 A DHMGODPX063 1751.00 DHMGOFPX063 3286.00 as per Havells Regular Terms & Conditions 31

Control & Monitoring Devices Automatic Modular Contactors Automatic Modular Contactors - SP (Applicable Standard - IEC 61095) Poles Rating Number of Contacts Width in multiples of 1 module (18 mm) Product Code 1 P 25 A 1 NO 1 DHPRG025110M 990.00 Automatic Modular Contactors - DP (Applicable Standard - IEC 61095) Poles Rating Number of Contacts Width in multiples of 1 module (18 mm) Product Code 2 P 16 A 2 NO 1 DHPRF016120M 1140.00 2 P 25 A 2 NO 1 DHPRF025120M 1386.00 2 P 40 A 2 NO 2 DHPRF040220M 2403.00 2 P 63 A 2 NO 2 DHPRF063220M 2889.00 Automatic Modular Contactors - TP (Applicable Standard - IEC 61095) Poles Rating Number of Contacts Width in multiples of 1 module (18 mm) Automatic Modular Contactors - FP (Applicable Standard - IEC 61095) Poles Rating Number of Contacts Width in multiples of 1 module (18 mm) Product Code Product Code 3 P 25 A 3 NO 2 DHPRA025230M 1771.00 3 P 40 A 3 NO 3 DHPRA040330M 4066.00 3 P 63 A 3 NO 3 DHPRA063330M 4414.00 4 P 25 A 4 NO 2 DHPRC025240M 1873.00 4 P 40 A 4 NO 3 DHPRC040340M 3949.00 4 P 63 A 4 NO 3 DHPRC063340M 4880.00 4 P 63 A 2 NO + 2 NC 3 DHPRC063322M 4270.00 Automatic Modular Contactors with Manual Override Automatic Modular Contactors with Manual Override - SP (Applicable Standard - IEC 61095) Poles Rating AC-7a Number of Contacts Width in multiples of 1 module (18 mm) Product Code 1 P 25 A 1 NO 1 DHPMG025110M 1151.00 Automatic Modular Contactors with Manual Override - DP (Applicable Standard - IEC 61095) Poles Rating AC-7a Number of Contacts Width in multiples of 1 module (18 mm) Product Code 2 P 16 A 2 NO 1 DHPMF016120M 1204.00 2 P 25 A 2 NO 1 DHPMF025120M 1445.00 2 P 40 A 2 NO 2 DHPMF040220M 2461.00 2 P 63 A 2 NO 2 DHPMF063220M 2948.00 Automatic Modular Contactors with Manual Override - TP (Applicable Standard - IEC 61095) Poles Rating AC-7a Number of Contacts Width in multiples of 1 module (18 mm) Product Code 3 P 25 A 3 NO 2 DHPMA025230M 1830.00 3 P 40 A 3 NO 3 DHPMA040330M 4131.00 3 P 63 A 3 NO 3 DHPMA063330M 4473.00 Automatic Modular Contactors with Manual Override - FP (Applicable Standard - IEC 61095) Poles Rating AC-7a Number of Contacts Width in multiples of 1 module (18 mm) Product Code 4 P 25 A 4 NO 2 DHPMC025240M 1932.00 4 P 40 A 4 NO 3 DHPMC040340M 4211.00 4 P 63 A 4 NO 3 DHPMC063340M 5083.00 32 as per Havells Regular Terms & Conditions

Photovoltaic Switchgear Range Photovoltaic Switchgear Range Photovoltaic Disconnector Pole Rating Blown Fuse Indicator Std. / Master Packing (No. of Unit/s) Product Code 1P 30 A No 10 N DHFCSN301K 193.00 1P 30 A Yes 10 N DHFDSN301K 225.00 Photovoltaic Fuse Link Rating Std. / Master Packing (No. of Unit/s) as per Havells Regular Terms & Conditions 33 Product Code 15 A 10 N DHHRHP0015 182.00 30 A 10 N DHHRHP0030 193.00

No. of Ways Item Cat No. (SD) Accessories for DB s Cable End Box (For mounting on top or bottom of Distribution Box for extra wire & cables) Cat No. (DD) 4 SP&N DHDASHOS04 461.00 DHDASHOD04 626.00 8 SP&N DHDASHOS08 594.00 DHDASHOD08 723.00 12 SP&N DHDASHOS12 728.00 DHDASHOD12 878.00 16 SP&N DHDASHOS16 856.00 DHDASHOD16 1156.00 4 TP&N - Horizontal DHDATHOS04 905.00 DHDATHOD04 963.00 6 TP&N - Horizontal DHDATHOS06 1038.00 DHDATHOD06 1183.00 8 TP&N - Horizontal DHDATHOS08 1295.00 DHDATHOD08 1429.00 12 TP&N - Horizontal DHDATHOS12 1686.00 DHDATHOD12 1959.00 4/8/12 TP&N - Vertical DHDATVOS04 1429.00 DHDATVOD04 1622.00 4/8/12 Loadline DHDATVLS04 1429.00 DHDATVLD04 1552.00 2+8 PPI DHDATVTS10 1167.00 DHDATVTD10 1295.00 2+12 PPI DHDATVTS14 1429.00 DHDATVTD14 1552.00 Plastic Channels Cat. No. P-Channel Description Where used in List DHDSNVDRZ04040/63 DSCPGMDBX099 SPN 12 Way Flat Grey DHDPTVPDRW08 311.00 DSCPGMDBX100 SPN 16 Way Flat Grey DHDPTVODRW04/08/12 HDSNVDRZ06040 DHDSNVDRZ06063 DHDSNVDRZ08040/63 DHDPTVPDRW12 HSN Code - 8538 343.00 DSCPGMDBX105 SPN 12 Way Flat Ivory DHDSNVDPZ04040/63 311.00 DHDSNVDPZ06040/63 DSCPGMDBX106 SPN 16 Way Flat Ivory DHDSNVDPZ08040/63 343.00 DSCPGMDBX126 SPN 4 Way Curve Grey DHDPSHODRW04 311.00 DSCPGMDBX127 SPN 8 Way Curve Grey DHDPSHODRW08 DHDPTHODRW04 343.00 DSCPGMDBX128 SPN 12 Way Curve Grey DHDPSHODRW12 DHDPTHODRW06 386.00 DSCPGMDBX129 SPN 16 Way Curve Grey DHDPSHODRW16 DHDPTHODRW08 407.00 DSCPGMDBX131 TPN 12 Way Curve Grey DHDPTHODRW12 482.00 DSCPGMDBX132 SPN 4 Way Curve Ivory DHDPSHODPW04 311.00 DSCPGMDBX133 SPN 8 Way Curve Ivory DHDPSHODPW08 DHDPTHODPW04 338.00 DSCPGMDBX134 SPN 12 Way Curve Ivory DHDPSHODPW12 DHDPTHODPW06 386.00 DSCPGMDBX135 SPN 16 Way Curve Ivory DHDPSHODPW16 DHDPTHODPW08 407.00 DSCPGMDBX137 TPN 12 Way Curve Ivory DHDPTHODPW12 461.00 Plug & Sockets HSN Code - 8538 Cat. No. Description DSSPLX0035 20 A DP PLUG ASSEMBLY 382.00 DSSPLX0036 20 A DP SOCKET ASSEMBLY 382.00 DSSPLX0037 30 A TP PLUG ASSEMBLY 806.00 DSSPLX0038 30 A TP SOCKET ASSEMBLY 806.00 Rotary Switch HSN Code - 8538 Cat. No. Description DSCCPAMCX010 40 A PHASE-SEL. SWITCH 674.00 DSCCPAMCX009 63 A PHASE-SEL. SWITCH 997.00 Auxiliary Contact (Factory Fitted) Rating Cat No. 2 A-4 A DHMCCDPF00211-00411 996.00 6 A-32 A DHMCCDPF00611-03211 851.00 40 A DHMCCDPF04011 1054.00 63 A DHMCCDPF06311 1194.00 Neutral Link & Earth Link HSN Code - 8538 Neutral Link Cat. No. Earth Link Cat. No. Description DSCBRCDBX002-2W P&S 166.00 DSCBRCDBX011 DSCBRCDBX006 SPN 4 Way 204.00 DSCBRCDBX090 DSCBRCDBX093 SPN 6 Way 236.00 DSCBRCDBX012 DSCBRCDBX007 SPN 8 Way 257.00 DSCBRCDBX013 DSCBRCDBX003 SPN 12 Way/TPN 4 Way 289.00 DSCBRCDBX014 DSCBRCDBX004 SPN 16 Way 332.00 DSCBRCDBX015 DSCBRCDBX005 TPN 6 Way 386.00 DSCBRCDBX016 DSCBRCDBX009 TPN 8 Way 428.00 DSCBRCDBX017 DSCBRCDBX008 TPN 12 Way 471.00 Copper Bus Bar HSN Code - 8538 Cat. No. Description DSCCUPDBP028 BUSBAR SPN 4 Way 204.00 DSCCUPDBP032 BUSBAR SPN 6 Way 247.00 DSCCUPDBP029 BUSBAR SPN 8 Way 273.00 DSCCUPDBP030 BUSBAR SPN 12 Way 364.00 DSCCUPDBP031 BUSBAR SPN 16 Way 380.00 Miscellaneous HSN Code - 8538 Cat. No. Description DSCPGMDBX019 N/L BASE 86.00 DSCPGMDBX001 Dummy (Blanking) Plate 18 mm 27.00 DSCPGMDBX045 KNOB SNAP TYPE GREY 75.00 DSCPGMDBX046 KNOB SNAP TYPE PI 75.00 DSCCPAMCX005 GREEN INDICATOR SWITCH SMALL 86.00 Indicator Light (In accordance with IS/IEC 60947-5-1) 240 V~, 50 Hz HSN Code - 8531 Colour TP Cat. No. Red DHMCYSPX000 209.00 Amber DHMCXSPX000 209.00 Blue DHMCVSPX000 209.00 Green DHMCZSPX000 209.00 Clear DHMCWSPX000 209.00 Shunt Trip (Factory Fitted) Rating Cat No. 32 A, 24 Vdc DHMCCDPF03222 466.00 32 A, 240 Vdc DHMCCDPF0322400 1857.00 Contactor Auxilary Standard Compliance Contacts Configuration Product Code IEC 60947-5-1 1 NO+1 NC DSSRCX0147 1375.00 34 as per Havells Regular Terms & Conditions