Installation manual CF8-W-Disp-AL

Similar documents
asense m III in industrial wall mounted housing / CO sensor with built-in general purpose controller

Installation manual CF3-D, CF3-D-Disp

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

AQS51/61-KAM COMBINED CO 2 -/TEMPERATURE DUCT SENSOR/CONTROLLER

esense Duct (-Disp) Conduit

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

2001VT Temp & CO 2. - air quality sensor/controller NOTE!!! Manual for Installation. General. SenseAir AB

Digital Keypad Introduction

RТTH DUAL ROOM SWITCH

CDD4 Series Room CO2 Transmitter Installation Instructions

RXTP ROOM TEMPERATURE

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RXTH DUAL ROOM SENSOR / SWITCH

Installing Keypad and Backplate

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

CDD4 Duct Carbon Dioxide Transmitter

CDD Carbon Dioxide Transmitter

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

CODE 50108, 50110, 50164, 50165

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

The unit is designed for connecting to Direct Digital Control (DDC). The linear output functions are pre-programmed as CO 2

NSGV Series "90DM3" Carbon Dioxide Detector

Mechanical Relay Board: 8 and 4 gang

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL

BMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding.

CDD ModBus Carbon Dioxide Detector

D/E Remote Relay Panel User Guide

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Carbon Monoxide Sensor - ModBus

Wireless Key fob, Key pad & Receiver Range

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

TPE 1464 Series Pressure Transducer

System Components Surge Arrester HAW 261 and HAW 262

TruPortal Output Expansion Board Quick Reference

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

LPG STM 94442A User s Manual

Fingerprint Access Control F1. User Manual

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

Installing Sentor. Hardware Installation

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

PSM-2 POWER SUPPLY MODULE INSTRUCTIONS

MAXIMA+ Series Rotary Level Indicator

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

Component identification

GF92 Installation, Operation and Troubleshooting Guide

H3CA-8H-AC/100/110/120

RTD-NET Installation Instructions

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

DTMF-4HC. DTMF decoder board with four high current relays. Copyright 2004 Intuitive Circuits, LLC

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

PTC/PT100 board 2.0 Option

MAXIMA + Series ROTARY LEVEL CONTROL

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

Devices raised mounting

User Manual. PCKeypad Wireless Keypad

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Installation Guide. Section 1 - Room... pg 03. Section 2 - Duct... pg 23. I-CDD3_Modbus Installation. Modbus Gas Transmitters I-CDD3 Series

Analog Output Module Installation Instructions

smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Product and functional description

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector

Differential Liquid/Gas Pressure Transmitter

DSI-4. DMX Optically Isolated 1x4 Splitter. D Series. DSI_4 Users Manual r3.lwp copyright 2009, 2010, 2011 ELM V. T. Inc.

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

SLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L)

SITRANS F Coriolis Flowmeters SITRANS FCT030 transmitter Quick Start

Operation and Maintenance Manual

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

RTD-W Installation Instructions

USER S MANUAL. DAS-G01 The Power of Tomorrow

Switching Power Supply

Displays Transducers. Displays and transducers

The Single Dimmer Board

Installation Instructions (KF-2000)

Installation Guide. Carbon Dioxide (CO 2. ) Detectors. General Information. Mounting WARNING CAUTION. SAE-1011/1012 Space Mount SAE-1011/1012/1062

Installation Instructions

Switched Mode Power Supply Operating manual PAP800

Manual Control Unit GFC 32

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

HOW TO REPLACE A PARKER INVERTER DRIVE WITH A YASKAWA V1000 INVERTER DRIVE

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

InBin-P Pressure switches from 5 Pa Pa

Modbus Header Temperature Sensor Kits: Standard Voltage Low Voltage

Product and functional description

PTC/PT100 board 2.0 Option

Switching Power Supply

Gadget Freak Case #238: Controller Adjusts Garage Lights Build Instructions

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Transcription:

Installation manual CF8-W-Disp-AL CO 2 transmitter with two relays mounted in industrial housing prepared for Modbus communication protocol 4 7 8 8 6 3 2 5 Wall plate 5 Snap-in lid 2 PCB (Factory supplied mounted in box) 6 Locking screw of the lid (not shown) 3 Temperature sensor 7 PG9 cable entry bushing 4 Hole for wall plate hooks 8 Air holes IMA 20 (6)

9 Lid locking screw 0 Wall plate Locking screw 2 Drill mark for cable entry bushing 3 Drill mark for cable entry bushing Dismounting the wall plate The sensor is delivered with the wall plate mounted. The wall plate has to be removed before the sensor is mounted onto the wall. Unscrew the screw on the side of the box. See figure 3. Wall Mounting Instruction Normally the PCB should not be removed from the housing. If for some reason the PCB must be removed it must be handed carefully and protected from electrostatic discharge. ) Electrical cable entry: The box has a factory mounted cable entry bushing in dimension PG9. Never feed more than one cable through each cable entry bushing, or else gas might leak through! 2) Screw the wall plate onto the wall: The wall plate has holes for three screws. Drill holes for 3,5mm screws and put dowel into them. Dowels and screws 3,5 x 25mm are included in a plastic bag 3) Attaching the sensor box to the wall plate is done by a snap-in fitting. The wall plate has three hooks that fit in holes in the sensor box. Fasten the screw on the side of the box. 4) The lid can be locked with the screw at the bottom of the sensor box. If for some reason the PCB must be removed it must be handed carefully and protected from electrostatic discharge! Normally, removing the PCB is not required. IMA 20 2 (6)

Electrical connections The power supply has to be connected to and. is considered as system ground. If the analogue output is connected to a controller the same ground reference has to be used for the CF8-W-Disp-AL unit and for the control system! Unless different transformers are used, special precautions need to be taken. PLEASE NOTE! The CF8-W-Disp-AL signal and power supply grounds are common. PLEASE NOTE! The same ground reference has to be used for the CF8-W-Disp-AL unit and for the control system! If possible keep the sensor powered up after mounting. Connect the analogue output before measuring. ~ + IMA 20 3 (6)

No Connection Terminal ~ + Function Electrical Data Remarks Power (+) 24 VAC/DC+ (+-20%), 3W 2W without output load See note! 2 3 Out() Power ground (-) Analogue Output (+) 24 VAC/DC- 0-0 VDC or 0-20 ma 2-0 VDC or 4-20 ma According to positions of OUT and start point jumpers. See note 2! 4 5 6 7 8 9 0 Out(2) Unmarked NO COM NC (OUT3) NO2 COM2 NC2 (OUT4) Communication jumper Analogue Output 2 (+) Signal Ground (-) Relay Normally Open Relay Common Relay Normally Closed Relay2 Normally Open Relay2 Common Relay2 Normally Closed Used to set communication protocol 0-0 VDC or 0-20 ma 2-0 VDC or 4-20 ma Connected to via PTC fuse Contact free relay minimum load ma/5v rated load 0,5A/25VAC; A/24VDC Contact free relay minimum load ma/5v rated load 0,5A/25VAC; A/24VDC Upper According to positions of OUT2 and start point jumpers. See note 2! See note! Standard Open <.4 % CO 2 Closed >.5 % CO 2 The relay output is potential free Standard Open < 2.9 % CO 2 Closed > 3.0 % CO 2 The relay output is potential free Modbus communication protocol Table I. Electrical terminal connections for CF8-W-Disp-AL Note : The ground terminal is used as negative power supply DC input or AC phase ground (halfwave rectifier). The signal ground M, protected by a PTC resistor, is the same as power ground G0 (permitting a 3-wire configuration). A single transformer may be used for the entire system. Note 2: CF8-W-Disp-AL can deliver a voltage or a current loop for Out()/Out(2). To change between voltage and current output mode the hardware jumpers are used. There is one jumper for Out() and one for Out(2), so that one output can be a voltage output and the other a current output. Both, voltage output and current output, can have start points 0 % (0-0 VDC or 0-20mA) or 20% (2-0 VDC or 4-20mA). The same start point is used for both outputs. See the user manual. IMA 20 4 (6)

~ + An application example illustrating connections to peripheral alarm devices are shown here. Connection of peripheral alarm devices to relay and relay 2 IMA 20 5 (6)

Dimensions and holes 85 (3,35) 38,5(,5) 0(0,39) 9,5 (0,37) 85 (3,35) 4,8 (5,58) 40 (,57) The dimensions of the sensor in mm and inches 63(2,48) 42(,65) 66(2,60) 39,9(,57) Ø5(0,20) Ø5(0,20) 40,5(,59) 7,5(0,69) 4(,6) 82(3,23) Ø5(0,20) The measurements of the wall plate in mm and inches IMA 20 6 (6)