Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

Similar documents
Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

Lantech I(P)GS-0008B. 8 10/100/1000T (PoE at/af) Industrial Unmanaged Ethernet Switch I(P)ES-0008B

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

LNX-0702G-SFP Series

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

LNX-1002C-SFP Series

I(P)GS-3208MGSFP I(P)GS-3208C I(P)GS-3204MGSFP I(P)GS-3008 IP30-rated Series

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

LNP-0501 Series. User Manual. 5-Port Industrial PoE+ Unmanaged Ethernet Switches with 4*10/100Tx (30W/Port) + 1*10/100Tx

IWMR-3002 Industrial Multifunction VPN Router w/up to 2x WiFi 11ac + up to 2 LTE 4G + 2/4 serial ports + 2 Gigabit Ethernet Switch

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

IEEE BASE-T IEEE 802.3u 100BASE-TX. ITU-T -G.993.1(VDSL) -G compatible

Manual Documentation Number EIR418-2SFP-T 0912m

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

LT-PIGE-802GBTME User Manual Version 1.0

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

5-Port 10/100Mbps with 4-Port PoE. Industrial Fast Ethernet Switch ISW-504PT / ISW-514PT / ISW-514PT15 / ISW-514PTF. User's Manual

Industrial 8-Port 10/100TX 802.3at PoE+ + 2-Port Gigabit TP/SFP Combo Ethernet Switch IFGS-1022HPT. User s Manual

Industrial 5-/8-Port 10/100TX Compact Ethernet Switch. ISW-500T/ISW-800T User s Manual

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

IPGS-3XXX IPGS-5XXX IGS-3XXX IGS-5XXX IP30-rated Series

Industrial 8-Port 10/100/1000T + 2-Port 100/1000X SFP Ethernet Switch (-40~75 degrees C)

Manual Elinx EIR408-T. 8 Port-10/100/1000 Unmanaged Din Rail Ethernet Switch

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

IPES/IES-0208 Series

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Manual Elinx EIRHP305-T. 5 Ports10/100 with 4 PoE Ports Unmanaged Din Rail Ethernet Switch

IFS MC350-1T-2S User Manual

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

IMC-21GA Quick Installation Guide

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

FRG-3105 Series Residential Gateway

Quick Start Guide. Physical Description. The Port Status LEDs

5/8-Port 10/100/1000Mbps. Industrial Gigabit Ethernet Switch IGS-501 / IGS-801 / IGS-501T / IGS-801T. User's Manual

Raven Series Standalone Media Converters

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

INDUSTRIAL POE SWITCH

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

HES-3106-PLUS SERIES

FSM-510G Series Ethernet Management Switch Quick Start Guide

Hardened Media Converter

Hardened PoE Ethernet Switch

Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and

Industrial 1-Port Coax/UTP Long Reach PoE+ 4-Port. 10/100TX PoE Extender LRP-104CET. User s Manual

Industrial 3-Port Fast Ethernet Media Converter Switches

Industrial Ethernet Switch

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

PoE Injector Hutschiene PoE-H

Industrial 10G/5G/2.5G/1G/100M Copper to 10GBASE-X SFP+ Media Converter

Fast Ethernet Converter. User Guide MICROSENS

4. 4 x Foot Pads 5. Rack-Mount Kit

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

XPress-Pro SW User Guide

4-Port 10/100Mbps +1/2 100FX Fiber Port. Industrial Fast Ethernet Switch. ISW-511 / ISW-621 Series. ISW-511T / ISW-621T Series.

MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC:

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

User Guide TL-SG1005D TL-SG1008D. 5/8-Port Gigabit Desktop Switch. alarm shop. Rev:

1000Base-SX / LX to 10/100/1000Base-T 802.3at PoE Industrial Media Converter

EDS-G308 Series Quick Installation Guide

ROCKETLINX ES7110. Quick Installation Guide Rev C ES7110 ES7110-VB. Industrial PoE Switch

10/100/1000Base-T to 1000Base-FX Switch Converter User Guide

8~14-Port Managed Ethernet Switch

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

IMC-21 Quick Installation Guide

Industrial Slim Type Fast Ethernet Rail Switch

IPS-3110 Managed Industrial PoE Gigabit Ethernet Switch

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

Industrial 10/100/1000T to 2 100/1000X SFP Media Converter IGT-1205AT. Copyright PLANET Technology Corporation. All rights reserved.

XPress-Pro SW User Guide

KFC-200. Installation Guide

8-port 10/100Base-TX Switch (INS-806) User s Guide

Industrial 10G/5G/2.5G/1G/100M Copper to. 10GBASE-X SFP+ Media Converter IXT-705AT. User s Manual

EKI-7529MI, EKI-7529MI/ST FX Port Unmanaged Industrial Ethernet Switch. User Manual

IMC-21A Quick Installation Guide

4-Port 10/100Mbps +1/2 100FX Fiber Port. Industrial Fast Ethernet Switch. ISW-511 / ISW-621 Series. ISW-511T / ISW-621T Series.

EDS-G205A-4PoE Hardware Installation Guide

PTC-101 Quick Installation Guide

5/8 Port Gigabit Ethernet Switch

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

EKI-2528PAI 8-port Industrial Unmanaged Ethernet Switch with 4-port PoE. User Manual

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide

Transcription:

Lantech IGC-0101DSFP IPGC-0101DSFP 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter User Manual Dec 2016

Recommendation for Shielded network cables STP cables have additional shielding material that is used to reduce external interference. The shield also reduces the emission at any point in the path of the cable. Our recommendation is to deploy an STP network cable in demanding electrical environments. Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable. It is also mandatory to use an STP cable where the power device (like IP camera) is used outdoors or where the network cable is routed outdoors.

Content Overview... 1 Introduction: IGC-0101DSFP... 1 Introduction: IPGC-0101DSFP... 2 Packing List... 3 Safety Precaution... 3 Hardware Description... 4 Front Panel... 4 Top View... 5 Wiring the Power Inputs... 5 Wiring the Fault Alarm Contact... 6 LED Indicators... 7 DIP-Switch... 7 Ports... 8 Cabling... 9 Mounting Installation... 13 DIN-Rail Mounting... 13 Wall Mount Plate Mounting... 15

Hardware Installation... 16 Installation Steps... 16 Troubles shooting... 18

FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. CE Mark Warning This is a Class-A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Overview Introduction: IGC-0101DSFP The Lantech IGC-0101DSFP is an Industrial Converter converting from 10/100/1000BaseT to 100/1000M-FX dual speed. It supports 10K bytes jumbo frame. Auto-sensing LLF and Power Fault LED/relay alarm setting by DIP switch Featured with LLF (Link Loss Forwarding) function, Lantech IPGC-0101DSFP is able to auto cut off connection if one end of connection is down. When copper port disconnects, it will auto turn off fiber port. When fiber port disconnects, it will auto turn off copper port. Smart LLF function alert central side switch immediate remedy action when connection is lost. Power Fault LED and relay alarm can be off by DIP switch. Dual power input from 9V~72VDC/18~36VAC with galvanic isolation IGC-0101DSFP supports dual wide range input from 9V~72VDC (12V model) and 18~36VAC (AC model) with galvanic isolation that is good for various application including vehicle, railway, solar panel etc. Hardened design with extended temperature range It provides ±2000V EFT and ±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet. It has high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines. The -E model can be used in extreme environments with an operating temperature range of -40 C to 75 C. 1

Introduction: IPGC-0101DSFP The Lantech IPGC-0101DSFP is an Industrial Converter converging from 10/100/1000BaseT to 100/1000M-FX dual speed with 802.3at/af PoE support. It supports 10K jumbo frame. Auto-sensing LLF and Power Fault LED/relay alarm setting by DIP switch Featured with LLF (Link Loss Forwarding) function, Lantech IPGC-0101DSFP is able to auto cut off connection if one end of connection is down. When copper port disconnects, it will auto turn off fiber port. When fiber port disconnects, it will auto turn off copper port. Smart LLF function alert central side switch immediate remedy action when connection is lost. Power Fault LED and relay alarm can be off by DIP switch. Dual DC input power IPGC-0101DSFP supports dual input from 9.5V~72VDC (12V model) or 44V~57VDC (48V model) for various application including vehicle, railway, solar panel etc. Hardened design with extended temperature range It provides ±2000V EFT and ±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet. It has high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines. The -E model can be used in extreme environments with an operating temperature range of -40 C to 75 C. 19 Rack mount-able kit for single or dual converter mounting The optional 19 rack-mount kit can be mounted with single or dual converters. 2

Packing List 1 x 10/100/1000 to Mini-GBIC Industrial Switch Converter 1 x Terminal Block Safety Precaution Attention IF DC voltage is supplied by an external circuit, please use a protection device on the power supply input. 3

Hardware Description In this paragraph, we will introduce the Industrial switch converter s hardware spec, port, cabling information, and wiring installation. Front Panel The Front Panel of the IGC-0101DSFP/IPGC-0101DSFP is shown as below. Front Panel of the Industrial Switch Converter 4

Top View The top panel of the Industrial Switch Converter is equipped one terminal block connector of two DC power inputs. Top panel of the Industrial Switch Converter Wiring the Power Inputs Please follow the steps below to insert the power wire. 1. Insert the positive and negative wires into the V+ and V- contacts on the terminal block connector. 5

2. To tighten the wire-clamp screws for preventing the DC wires to loose. Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the picture shows below. Inserting the wires, it will detect the fault status which the power is failure or port link failure (for managed model) and form an open circuit. Insert the wires into the fault alarm contact (No. 3 & 4) Note The wire gauge for the terminal block should be in the range between 12~ 24 AWG. 6

LED Indicators There are few LEDs display the power status and network status located on the front panel of the Industrial switch converter, each of them has its own specific meaning as below table. Table 2.1: Industrial Switch Converter LED Definition LED Color Description PWR1 Green On Power input 1 is active Off Power input 1 is inactive PWR2 Green On Power input 2 is active Off Power input 2 is inactive On Power input 1 or 2 has failed Fault Red Power input 1 and 2 are both functional, Off or no power input On Connected to network LNK/ACT Green Flashing Networking is active (fiber port) Off Not connected to network PoE On Link to PD(PoE device) Green (IPGC only) Off Link to none PoE device DIP-Switch The DIP-Switch is used to configure operation mode for LLF (Link Lost Forwarding) and power alarm. The default value of DIP-switch is OFF. Table 2.2: Industrial Switch Converter DIP-Switch Definition S/W Status Description Fault ON Enable Power Alarm OFF Disable Power Alarm SFP 100M Set SFP speed as 100M Speed 1000M Set SFP speed as 1000M 7

Ports RJ-45 ports (Auto MDI/MDIX): The RJ-45 ports are auto-sensing for 10Base-T, 100Base-TX or 1000Base-T devices connections. Auto MDI/MDIX means that you can connect to another switch or workstation without changing straight through or crossover cabling. See figures as below for straight through and crossover cable schematic. RJ-45 Pin Assignments Pin Number Assignment 1 Tx+ 2 Tx- 3 Rx+ 6 Rx- Note + and - signs represent the polarity of the wires that make up each wire pair. All ports on this industrial switch converter support automatic MDI/MDI-X operation, you can use straight-through cables (See Figure below) for all network connections to PCs or servers, or to other switches or hubs. In straight-through cable, pins 1, 2, 3, and 6, at one end of the cable, are connected straight through to pins 1, 2, 3 and 6 at the other end of the cable. The table below shows the 10BASE-T/ 100BASE-TX /1000Base-T MDI and MDI-X port pin outs. Pin MDI-X Signal Name MDI Signal Name 1 Receive Data plus (RD+) Transmit Data plus (TD+) 2 Receive Data minus (RD-) Transmit Data minus (TD-) 3 Transmit Data plus (TD+) Receive Data plus (RD+) 6 Transmit Data minus (TD-) Receive Data minus (RD-) 8

Straight Through Cable Schematic Cross Over Cable Schematic Cabling Twisted-pair segment can use unshielded twisted pair (UTP) or shielded twisted pair (STP) cabling. The cable between the link partner (switch, hub, workstation, etc.) and the converter must be less than 100 meters (328 ft.) long and comply with the IEEE 802.3ab 1000Base-T standard for Category 5e or above. Fiber segment using single-mode connector type must use 9/125μm single-mode fiber cable. You can connect two devices in the distance of 10 km. Fiber segment using multi-mode connector type must use 50/125 or 62.5/125μm multi-mode fiber cable. You can connect two devices up to 550m distances. The small form-factor pluggable (SFP) is a compact optical transceiver used in optical communications for both telecommunication and data communication applications. To connect the transceiver and LC cable, please follow the steps shown below: First, insert the transceiver into the SFP module. Notice that the triangle mark is the bottom of the module. 9

Figure 2.8: Transceiver to the SFP module Figure 2.9: Transceiver Inserted 10

Second, insert the fiber cable of LC connector into the transceiver. Figure 2.10: LC connector to the transceiver To remove the LC connector from the transceiver, please follow the steps shown below: First, press the upper side of the LC connector from the transceiver and pull it out to release. Figure 2.11: Remove LC connector 11

Second, push down the metal loop and pull the transceiver out by the plastic part. Figure 2.12: Pull out from the SFP module 12

Mounting Installation DIN-Rail Mounting The DIN-Rail is screwed on the industrial switch when out of factory. If the DIN-Rail is not screwed on the industrial switch, please see the following figure to screw the DIN-Rail on the switch. Follow the below steps to hang the industrial switch. 1. Use the screws to screw on the DIN-Rail on the industrial switch 2. To remove the DIN-Rail, reverse the step 1. 13

3. First, insert the top of DIN-Rail into the track. 4. Then, lightly push the button of DIN-Rail into the track. 5. Check the DIN-Rail is tightly on the track. 6. To remove the industrial switch from the track, reverse steps above. 14

Wall Mount Plate Mounting *Optional Wall Mount Kit required Follow the steps below to mount the industrial switch with wall mount plate. 1. Remove the DIN-Rail from the industrial switch; loose the screws to remove the DIN-Rail. 2. Place the wall mount plate on the rear panel of the industrial switch. 3. Use the screws to screw the wall mount plate on the industrial switch. 4. Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall. 5. To remove the wall mount plate, reverse steps above. 15

Hardware Installation In this paragraph, we will describe how to install the 10/100/1000Base-T Industrial Switch converter and the installation points for the attention. Installation Steps 1. Unpacked the Industrial switch converter packing. 2. Check the DIN-Rail is screwed on the Industrial switch converter. If the DIN-Rail is not screwed on the Industrial switch converter. Please refer to DIN-Rail Mounting section for DIN-Rail installation. If you want to wall mount the Industrial switch converter, then please refer to Wall Mount Plate Mounting section for wall mount plate installation. 3. To hang the Industrial switch converter on the DIN-Rail track or wall, please refer to the Mounting Installation section. 4. Power on the Industrial switch converter. How to wire the power; please refer to the Wiring the Power Inputs section. The power LED on the 16

Industrial switch converter will light up. Please refer to the LED Indicators section for meaning of LED lights. 5. Prepare the twisted-pair, straight through Category 5 cable for Ethernet connection. 6. Insert one side of Category 5e or above cables into the Industrial switch converter Ethernet port (RJ-45 port) and another side of category 5e or above cables to the network devices Ethernet port (RJ-45 port), e.g. switch, PC or Server. The UTP port (RJ-45) LED on the Industrial switch converter will light up when the cable connected with the network device. Please refer to the LED Indicators section for LED light meaning. Note Be sure the connected network devices support MDI/MDI-X. If it does not support, then use the crossover category 5e/above cable. 7. When all connections are all set and LED lights all show in normal, the installation is complete. 17

Troubles shooting Verify that you are using the right power cord/adapter (DC 9.5 ~ 56V), please don t use the power adapter with DC output higher than 56V, or it will burn this switch converter down. Select the proper UTP cable to construct your network. Please check that you are using the right cable. Use unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections: 100Ω Category 3, 4 or 5 cable for 10Mbps connections, 100Ω Category 5 cable for 100Mbps, or 100Ω Category 5e/above cable for 1000Mbps connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet). Diagnosing LED Indicators: To assist in identifying problems, the industrial switch converter can be easily monitored through panel indicators which describe common problems the user may encounter and where the user can find possible solutions. IF the power indicator does not light on when the power cord is plugged in, you may have a problem with power cord. Then check for loose power connections, power losses or surges at power outlet. IF you still cannot resolve the problem, contact your local dealer for assistance. If the Industrial switch converter LED indicators are normal and the connected cables are correct and the packets still cannot transmit. Please check your system s Ethernet devices configuration or status. 18