Artistic Licence. Net-Lynx I/P. User Guide. Net-Lynx I/P User Guide. Version 1-5

Similar documents
Artistic Licence. Net-Lynx O/P. User Guide. Net-Lynx O/P User Guide. Version 1-5

Artistic Licence. Cata-Lynx I/P. User Guide. Cata-Lynx I/P User Guide. Version 1-4

Artistic Licence. artlynx duo. User Guide. artlynx duo User Guide. Version 1-0

Artistic Licence. Ether-Lynx II. User Guide. Ether-Lynx II User Guide. Version 1-5

Artistic Licence. Mica. User Guide. Mica User Guide. Version 1-1

Artistic Licence. daligate quad. User Guide. daligate quad User Guide. Version 1-0

Artistic Licence. Rail-Demux. User Guide. Rail-Demux User Guide. Version 2-7

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

Artistic Licence. Rail-Split RDM. User Guide. Serial nos and upwards. Rail-Split RDM User Guide. Version 5-0

Artistic Licence. Rail-Split extreme. User Guide. Serial numbers 151 upwards. Rail-Split extreme User Guide. Version 5-0

Artistic Licence. Rail-DALI-DMX. User Guide. Rail-DALI-DMX User Guide. Version 1-5

Artistic Licence. matisse d4 dmx. User Guide. matisse d4 dmx User Guide. Version 1-1

Artistic Licence. versasplit. User Guide. versasplit User Guide. Version 1-5

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

EtherN.8 RDM & EtherN.2 RDM

Ether-Lynx User s Guide

Artistic Licence. Dali-Scope. User Guide. Dali-Scope User Guide. Version 1-8

Artistic Licence. nanoscope. User Guide. nanoscope User Guide. Version 1-0

Artistic Licence Price List

TouchXL Intuitive Display

8 channel Ethernet to analog interface. Web Server Configuration Manual

PIXELATOR MINI PX1-8D DIN-RAIL MOUNTABLE 8 PORT PIXEL CONTROLLER USER MANUAL

CS2 DMX Distribution Splitter

FTP1 Single Channel LED DMX Driver

SAVE THESE INSTRUCTIONS

R70 Ethernet to CAN interface Manual (1.4 EN)

Flexoled FTP3HP RGB LED DMX Driver

ACTpro Single Door IP Controller. Operating & Installation Instructions

DATAGATE MK2. Box Contents. Additional Features (licenses) Features. Safety

8 Button IP Controller Installation and Operation Manual AV-IP-C8-WH

XPD-28 2:8 DMX & RDM Splitter User Manual

Wash Light User Data. User Data - Specifications Date: 01/11/2016 Page 1/7. RGBW (White 4000k) Single Colour (R,G,B,A,W)

Instruction Manual. Anker USB 3.0 Docking Station

Table of Contents. Page ii

Microbar COB System. User Manual. Order code: EQLED137

ChamSys. Inspiring Performance. SnakeSys range

USER MANUAL. VA-1USB-T USB Transmitter. VA-1USB-R USB Receiver MODELS: P/N: Rev 3

Ethernet - DMX4 MkII Range. User Guide - V4.x.x

RGB Power Batten. User Manual. Order code: EQLED032

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

STANDARDS COMPLIANCE WEIGHTS AND DIMENSIONS INCLUDED FURNISHINGS

XND-4 4-Port Ethernet DMX Node User Manual

USB 2.0 RG2304 Network Series

Model NODE2 Installation and Operations Manual

Blitzer Strobe. User Manual. Order code: EQLED366

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Crossfire. User Manual. Order code: EQLED061

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

HDMI A/V over Gigabit Ethernet Adapter. User s Manual

Slimline CW & WW Series

Domino DFWEB. DFWEB: interface module between Domino bus and Ethernet network with Web-Server function. Module Connection. Domino

Product features. Points: Support parameters setting and firmware upgrade by App. Address programmable. Fast searching. Convenience testing

USB 2.0 RG2304GE-LAN. 4-Port USB 2.0 Gigabit Ethernet LAN Extender System. User Guide

User Manual Revision English

Interface USER MANUAL. DMXking.com JPK Systems Limited New Zealand

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Firmware version Operation may differ from other firmware versions

Ethernet - DMX2 MkII Range. User Guide - V4.x.x

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

USB port Hub with Ethernet Adapter. User s Manual

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Gobo Projector XP 80W

MICRON DJ Booth Tri-colour Starcloth

R60 USB to CAN interface Manual (1.4 EN)

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

EMC-1 TM. Ethernet Meterbus Converter. DIMENSIONS [inches (millimeters)] Installation and Operation Manual

UV Power Flood. User Manual. Order code: EQLED029

N4 Art-Net Node. Order code: CONT25. User Guide Please read these instructions carefully before use

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

EasiLED 4 DMX Controller

DOR6. Components All functions and indications are on the front of the module. Characteristics

BACnet/IP to BACnet MS/TP Router

ED-588 ETHERNET TO Digital IO 8 Inputs + 8 Outputs

Vortex. User Manual. Order code: EQLED073

DL-HDM44A-H2 Quick Install Guide

CDP 405 Digital Dimmer Pack

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

Gateway configuration manual IP - KNX EK-BE1-TP

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A

Vector Beam White. User Manual. Order code: LEDJ265

Technical Manual Nova: Cabinet Security Management System (CSMS)

APC100. User Manual.

VPort 06EC-2V Series Quick Installation Guide

Ethernet - DMX2 Box. User Guide - V3.0.0

ED-549. Ethernet to Analogue In ED-549. Connect, Configure, Control ED-549 ETHERNET TO ANALOGUE 8 INPUTS

DL-HD2100 Quick Install Guide

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

ColourChaser Touch. Installation Guide

User Manual Revision English

Kvaser USBcan II User's Guide

FieldServer X-25 Start-Up Guide

Features and Benefits. SNMP MIB-II for network management. Certifications

Product Manual. USB Charging Hub 10 Port Hi-Power 2.4A USB Charger Hub. Coolgear, Inc. Version 1.1 September 2017 Model Number: U2CHGRHUB10

1. Short description. 2. Features. 3. Technical parameters

GigaSwitch 8. User Guide

BAS Router BACnet Multi-Network Router

APM. User manual & Installation guide. Digital paging microphone.

Transcription:

Artistic Licence Net-Lynx I/P User Guide Version 1-5

Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be installed by a suitably qualified technician and in accordance with electrical regulations in the country of use. Unless directed in the instructions there are no user serviceable parts inside the outer case of this product. Always disconnect from the power supply when not in use. Any specific IP rating, where appropriate, is given in the instructions. Unless otherwise stated this product is designed for indoor use only. If used outdoors it MUST be installed in an appropriate IP rated cabinet. Do not allow this product to be exposed to rain or moisture. Do not allow liquid to penetrate the product. Please recycle all packaging. Copyright Artistic Licence Engineering Ltd. All rights reserved. Download the user guide by scanning the following QR code: Page 2

Connections Ref. Type Description 1 LED Data activity 2 LED Indicator for Power 3 LED Indicator for Ethernet 4 LED Data activity 5 Data Connection 6 Data Connection 7 Data Connection Ethernet DMX I/P A DMX I/P B 8 Power Input 9-48 VDC 9 Configuration Universe A Select 10 Configuration Sub-Net Select 11 Configuration Universe B Select Mounting Diagram Page 3

Product Overview Net-Lynx I/P is a desktop or truss-mounted DMX-to-Ethernet converter. It is capable of converting 2 Universes of DMX512 into Art- Net. The product is powered via an external power supply unit or, alternatively, the Power over Ethernet (PoE) standard. The product is easily configured by dialling in the required Sub-Net and Universe using the wheel selectors. Alternatively, Net-Lynx I/P can be remotely configured via the internal web-server or over the network using DMX- Workshop (free-of-charge software available from Artistic Licence). When used with Art- Net 3, DHCP is supported for automatic IP addressing. Summary of Key Features y Ethercon XLR/RJ45 10BaseT ethernet port, compatible with Art-Net y 2 DMX512 inputs, compatible with all variants of DMX y Ethernet data activity indicator y DMX data activity indicators y Power indicator y PoE compatible y Internal web-server for configuration (including support for DHCP when used with Art-Net 3). y Sub-Net and Universe wheels y Default IP address: 2.x.y.z y Truss-mountable using truss-ear adapter Power Net-Lynx I/P can be powered from either an external PSU (9 to 48 VDC) or with PoE (Power-Over-Ethernet). PoE requires a suitable ethernet switch for the power source, such as Art-Switch PoE4. The power LED indicator is on when the unit is powered. If it flashes, please refer to the Error Messages section for more information. Ethernet Connection Net-Lynx I/P has a single XLR-RJ45 ethernet connection. The interface is compatible with Art-Net (the public domain protocol invented by Artistic Licence). Net-Lynx I/P requires Cat 5 cable or better and supports 10BaseT. The ethernet LED data indicator is on when network data is active. If it is flashing, please refer to the Error Messages section for more information. DMX Inputs Net-Lynx I/P can convert a maximum of two Universes of DMX512 data. There are 2 DMX512 input ports (A and B) with XLR5 connectors. The DMX512-A standard specifies that Cat5 cable can be used to carry DMX data. The table below shows which cores should be used. It is recommended that Cat5E cable is used. The DMX A/B LED indicators are on when there is data activity. DMX512 Wiring XLR Pin (convention) Function Colour RJ45 Pin 1 COM Black 7 & 8 Cable Colour White/ Brown & Brown 2 DMX - Blue 2 Orange 3 DMX + Red 1 White/ Orange Universe, Sub-Net and Net Each universe being transmitted over ethernet needs to be distinguishable from other universes on the same network. For universe numbers up to 256 (the maximum limit of Art- Net II), this is achieved by setting the (4-bit) Universe and Sub-Net numbers. The settings can be made via the Sub-Net and Universe wheel selectors, or remotely (see Remote Configuration below). Page 4

In contrast, Art-Net 3 and sacn can carry up to 32768 and 65536 universes respectively. To handle these large values, the concept of a 16-bit port address including a Net field is introduced. The port address of each DMX512 universe is a number composed of the (Net)+(Sub-Net)+(Universe). Because the product has no Net wheel selectors, configuration must be done remotely if a port address greater than 256 is required. Note that settings made remotely override the wheel selectors on the front panel, in effect locking them out. If all the LED indicators flash 3 times when a wheel selector setting is changed, this means that the product has been remotely configured. Remote Configuration There are two ways of remotely configuring Net-Lynx I/P. These are: 1) using DMX- Workshop or 2) using the product s internal web-server. DMX-Workshop DMX-Workshop is a software application that runs on the Windows XP & Windows 7 platforms. It is free of charge and available via download from the Artistic Licence website. DMX-Workshop is a fully featured network management, analysis, configuration and diagnostics tool for Art-Net networks. When Net-Lynx I/P is connected to a computer running DMX-Workshop, it should be detected and displayed as an Art-Net node (click the Node List tab to verify this). The node can be expanded to show the configuration and DMX input information, as shown in the screen-shot opposite. Right-clicking on any entry brings up a menu that offers various functionality: y The Configure Node option enables configuration of the Universe, Sub-Net and Net values. It also allows the user to give the device a short and long name. y Copy to clipboard enables all the node information to be pasted into a support request email. DMX-Workshop Node List Note port address structure: (Net)-(Sub-Net)-(Universe) y Indicators enables selection of normal, locate or mute for the LED indicators. Normal is the default behaviour, locate causes the selected port LED to flash, and mute turns off all the LEDs. y Advanced leads to Programme Upload and Configure IP Address. These are described in more detail below. Firmware Upgrades The Programme Upload option enables the user to upgrade the product s firmware. DMX-Workshop stores the firmware files in C:\Program Files (x86)\artistic Licence\ DMX-Workshop\Firmware\*.alf. Selection of the desired file is made via a pop-up window that shows the available files. Ensure that the firmware upgrade is applied to all ports (check the Tick All box in the next window). Cycle the power after a successful upload. IP Address Configuration Choosing the Configure IP Address in the Advanced menu brings up a window that shows the IP and Subnet Mask. The IP uniquely identifies any nodes or controllers on a network, while the Subnet Mask defines which part of the IP represents the Network address and which part represents the Node address. For example, a Subnet Mask of 255.0.0.0 means that the first byte of the IP defines the network address and the remaining three bytes define the Node address. Page 5

By default, the product has a static IP address in the range 2.x.x.x. There are situations in which the user may wish to change this - for example, a 192.168.x.x address is generally used in office environments. A very useful additional feature of Net-Lynx I/P is the ability to enable automatic IP address allocation on networks controlled by a DHCP server (check the Enable DHCP box to activate this feature). Note that the default IP and static addressing can be forced manually by setting all 3 wheel selectors to F and turning the power off then on again. Web-Server To configure Net-Lynx I/P via the internal web-server, either type in the IP address of the product or, if your web-browser supports NetBios, then enter the name: http://netlynxip. To find the IP address, use DMX-Workshop or type ping 2.255.255.255 in a command line window. The internal web page shows the DMX port status and options to change the DMX and IP settings, as illustrated below. Web Browser Homepage DMX Input Settings The DMX Settings tab leads to the following configuration options: y Set Net, Sub-Net & Universe values y Enable/disable unicast y Set the IP address if unicast enabled IP Settings The configuration menu for the IP settings allows the user to set a custom IP address, Subnet Mask and Gateway IP. There is also an option to enable/disable DHCP for automatic IP address allocation. IP Settings Detail Module Info DMX Settings Detail The module info tab describes the jumper functionality (see Jumper configuration ), and also provides some helpful information regarding the DMX data transmission. Jumper Configuration There are several advanced settings, beyond the scope of normal operation, that can be accessed by fitting the supplied jumpers over the configuration pins. The jumper settings information is shown in the following table: Page 6

JP0-2 JP3 JP4 JP5 JP6 JP7 ROM Boot *Factory ROM mode ready for firmware upload. It is not usually necessary to use this procedure as firmware uploads can be initiated directly using DMX-Workshop. Error Messages On power-up, Net-Lynx I/P goes through a number of self-checks to ensure that it is functioning correctly. If an internal fault occurs the indicator LEDs are used to display an error code. **Contact Artistic Licence for advice. LED State Power & All alternately flashing Art-Net & All alternately flashing DMX A & All alternately flashing All flashing (informational) For future use HTTP server disabled (e.g. no web page functionality) 10.x.x.x IP addressing active (ignored when DHCP is active) RDM disabled on all outputs Inverts the low byte of the IP address For future use Description SRAM Fault** E2Prom Fault** System ROM Fault** Boot loader mode Net-Lynx I/P Specification Mechanical Switch to boot-loader* mode on power cycle y Housing: Desktop style case y Material: metal y Overall dimensions: 115 mm (H) x 195 mm (W) x 55 mm (D) y Weight: 0.7 kg y Mounting: Desktop or truss (requires adapter) y Country of manufacture: UK Environmental y Operating temperature: 0 C to 40 C y Storage temperature: -10 C to +50 C y Operating relative humidity (max): 80% noncondensing y IP rating: IP20 indoor use only y Certification: CE, FCC, WEEE, RoHS y Warranty: 2-year (return to base) Power & Electrical y Input voltage: 9-48 VDC y Input connector: 4-pin male XLR (1 no.) y Input power (max): 2 W y Duty cycle: 80% @ 25 C y DC fuse: internal resettable fuse for control electronics Ethernet y Type: 10BaseT y Isolation: 1 kv y PoE: supported DMX512 Inputs y Input mode: non-isolated y Input ESD protection: 2 kv y Input voltage protection: -7V to +12 V Control y Input Protocols: DMX512, DMX512 (1990), DMX512-A y Output Protocols: Art-Net Data Connections y Ethercon XLR-RJ45 (1 no.) y 5-pin male XLR DMX inputs (2 no.) LED Indication y Power / Ethernet Link / DMX Activity Configuration y Remote: Web-browser, DMX Workshop y Manual: Wheels / Jumpers y Configurable settings include: -- Net, Sub-Net, Universe -- IP Address (DHCP) -- ROM boot Page 7

Package Contents y Net-Lynx I/P y User guide y Jumpers (for configuration pins) Ordering Info y Product code: Net-Lynx I/P Accessories (not included) y PSU-9-1.5-XLR4 (powers 1 x Net-Lynx I/P) y Art-Switch PoE4 & PSU-48-1-DR (powers up to 4 x Net-Lynx I/P) y Truss-mount adapter Warranty All products are covered from date of purchase by a two-year return to base warranty. By return to base, we mean that the customer is responsible for all costs of transport to and from Artistic Licence. Returns will not be accepted without prior authorisation. In order to discuss a request to return goods, please email: Sales@ArtisticLicence.com Compliance All Products manufactured or sold by Artistic Licence Engineering Ltd are fully compliant with the appropriate CE, FCC, and RoHS regulations. Product specific information is available on request. Waste Electrical & Electronic Equipment (WEEE) Artistic Licence is a member of a WEEE compliance scheme and will happily recycle any of our products that you, at your expense, return to us. Artistic Licence Studio 1, Spectrum House 32-34 Gordon House Road London NW5 1LP United Kingdom Telephone +44 (0) 20 8863 4515 Fax +44 (0) 20 8426 0551 Email: Sales@ArtisticLicence.com Web: www.artisticlicence.com Customer support and knowledge base: www.artisticlicence.com/support.html CE Compliance Net-Lynx I/P is CE compliant Due to our policy of continuing product improvement specifications are subject to change without notice