DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Similar documents
DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

PRESSURE TRANSMITTER

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Industrial Pressure Transmitter

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

Electronic pressure switch with display Model PSD-4

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Electronic pressure switch with display For sanitary applications Model PSA-31

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Inductive sensor NI3-EG08K-Y1-H1341

FlexBar HRT Pressure Transmitter

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Linear Position Transducer HLT 1000-R2

Electronic pressure switch with display For sanitary applications Model PSA-31

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor BI1.5-EG08-Y1-H1341

standard, short, preferential, top

Linear Position Transducer HLT 1000-R2

Technical Data. General specifications. Rated operating distance s n 3 mm

Digital Positioner 8049

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

Series 3730 Type Electropneumatic Positioner

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Series 3730 Electropneumatic Positioner Type

Operating manual. Plug-On Display PA 430. Important notes:

Threaded thermocouple Miniature design Model TC10-D

FlexBar 3501 Pressure Transmitter

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Inductive sensor with analog output BI15-M30-LI-EXI

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive sensor BI5-EM18-Y1X-H1141

Threaded resistance thermometer Miniature design Model TR10-D

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Level measurement. Applications. Special features. Description

CMP Applications. Features

Pneumatic Control/Feedback

KINAX WT720 absolute, programmable angular postion transmitter

Pneumatic Control/Feedback

Multi-range pressure and differential pressure transmitter

Electronic Pressure Switch EDS 300

Distance and Position Sensors

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

M5100 Heavy Industrial Pressure Transducer

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Installation Instructions Temperature transmitter TAA /00 06/2011

Relative and absolute pressure transmitter type 528

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

PROFIBUS-PA Positioner Type 3785

Level measurement CleverLevel LBFI Point level detection

HERION SERIES Indirect solenoid actuated spool valves

Pneumatic Control/Feedback

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

CMP Applications. Features

OEM Products for Large Volume Production:

Temperature Switches

T 9510 EN Media 7 Differential Pressure Meter with remote data transmission

U7100 Pressure Transducer

Float switch For industrial applications Model RLS-1000

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Safety. Detection. Control. MAGNUS RFID ENG - REV

Electronic Level Switch ENS 3000

Sensor boxes SRBG Key features

Electronic Pressure Switches. Catalogue. Electronic Pressure Switches. Control. Overview. every move

TPE 1464 Series Pressure Transducer

Electronic Temperature Switches. Catalogue. Electronic Temperature Switches. Control. Overview. every move

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

PI-EX-ME-2NAM/COC-24VDC

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

SM9000. Magnetic-inductive flow meter. Made in Germany

ExCos-P Pressure sensor 20 Pa Pa

VM series. features. web contents. code description. available models. inductive sensors. Cylindrical M12 in AC B H

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Digital electropneumatic positioner

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

PHOENIX CONTACT - 12/2007

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Inductive displacement measurement system model series IE25P with programmable analogue interface

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

Transcription:

DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure from 0... 60 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire: 0 0 ma / 0 0 V others on request Special characteristics excellent long-term stability, also with high dynamic pressure loads insensitive to pressure peaks high overpressure capability Optional versions IS-version Ex ia = intrinsically safe for gases and dusts SIL version according to IEC 6508 / IEC 65 specific versions The pressure transmitter type DMP has been especially designed for use in hydraulic applications with high static and dynamic pressure. The transmitter is characterized by an excellent long term stability, also under fast changing pressure as well as positive and negative pressure peaks. The modulare concept of the device allows to combine different stainless steel sensors and electronic modules with a variety of electrical and mechanical versions. Thus a diversity of variations is created, meeting almost all requirements in hydraulic applications. Preferred areas of use are Plant and Machine Engineering - machine tools - hydraulic presses - injection moulding machine - handling equipment - elevated platforms - test benches Mobile Hydraulics BD SENSORS GmbH BD-Sensors-Straße Tel: +49 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax: +49 (0) 9 5 / 98 - info@bdsensors.de

DMP Input pressure range Nominal pressure gauge / abs. [bar] 60 00 60 50 400 600 Overpressure [bar] 0 600 600 050 50 50 Burst pressure [bar] 40 000 000 50 50 50 Output signal / Supply Standard -wire: 4... 0 ma / V S = 8... V DC Option IS-protection -wire: 4... 0 ma / V S = 0... 8 V DC Options -wire -wire: 0... 0 ma / V S = 4... 0 V DC 0... 0 V / V S = 4... 0 V DC Performance Accuracy standard: ± 0.5 % FSO option : ± 0.5 % FSO option : ± 0. % FSO Permissible load current -wire: R max = [(V S V S min) / 0.0] Ω current -wire: R max = 500 Ω voltage -wire: R min = 0 kω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year at reference conditions Response time -wire: 0 msec -wire: msec accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Tolerance band ± 0.75 % FSO in compensated range -0... 85 C Permissible temperatures Permissible temperatures medium: -40... 5 C electronics / environment: -40... 85 C storage: -40... 00 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (5... 000 Hz) according to DIN EN 60068--6 Shock 00 g / msec according to DIN EN 60068--7 Materials Pressure port stainless steel.4404 (6 L) Housing stainless steel.4404 (6 L) Option compact field housing stainless steel.405 (0), cable gland brass, nickel plated others on request Seals (media wetted) standard: FKM options: EPDM (for P N 60 bar) NBR others on request Diaphragm stainless steel.445 (6 L) Media wetted parts pressure port, seals, diaphragm Explosion protection (only for 4... 0 ma / -wire) Approval DX9-DMP IBExU 0 ATEX 068 X zone 0: II G Ex ia IIC T4 Ga zone 0: II D Ex iad 0 T85 C Safety technical maximum values U i = 8 V DC, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 μh Permissible temperatures for environment in zone 0: -0... 60 C with p atm 0.8 bar up to. bar in zone or higher: -0... 70 C Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: μh/m pressure measurement

DMP Miscellaneous Option SIL according to IEC 6508 / IEC 65 Current consumption signal output current: max. 5 ma signal output voltage: max. 7 ma Weight approx. 40 g Installation position any Operational life > 00 x 0 6 pressure cycles CE-conformity EMC Directive: 004/08/EC Pressure Equipment Directive: 97//EC (module A) 4 Pressure transmitters are calibrated in a vertical position with the pressure connection down. 4 This directive is only valid for devices with maximum permissible overpressure > 00 bar Wiring diagrams -wire-system (current) p supply + -wire-system (current / voltage) supply + p VS VS supply I supply I/U signal + A/V Pin configuration Electrical connection ISO 4400 Supply + Supply Signal + (for -Leiter) Electrical connections (dimensions in mm) Binder 7 (5-pin) 4 Mx / Metall (4-pin) Shield ground pin 5 4 field housing IN + IN OUT + cable colours (DIN 4700) wh (white) bn (brown) gn (green) gn/ye (green / yellow) standard option ISO 4400 Binder Series 7 5-pin Mx 4-pin cable outlet with PVC cable (IP 65) (IP 67) (IP 67) (IP 67) 5 compact field housing (IP 67) universal field housing stainless steel.4404 (6 L) with cable gland M0x.5 (ordering code 880) and other versions on request 5 standard: m PVC cable without ventilation tube (permissible temperature: -5... 70 C) 6 different cable types and lengths available, permissible temperature depends on kind of cable cable outlet, cable with ventilation tube (IP 68) 6 www.bdsensors.com

DMP Mechanical connections (dimensions in mm) standard for accuracy 0.5 / 0.5 % standard for accuracy 0. % ; SIL- and SIL-IS-version G/" DIN 85 G/" DIN 85 with ISO 4400 with ISO 4400 option G/" EN 87 G/4" DIN 85 G/4" EN 87 /" NPT metric threads and other versions on request This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. pressure measurement Telefon +49 (0) 9 5 / 98-0 Telefax +49 (0) 9 5 / 98 - www.bdsensors.com info@bdsensors.de DMP_E_007

Fax: +49 (0) 9 5 / 98 - Ordering code DMP DMP - - - - - - - Pressure Input Output gauge absolute 0 [bar] 60 6 0 0 00 0 0 60 6 0 50 5 0 400 4 0 0 600 6 0 0 9 9 9 4 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire E S Intrinsic safety 4 0 ma / -wire SIL 4 0 ma / -wire SIL with Intrinsic safety 4 0 ma / -wire ES Accuracy standard 0.5 % option 0.5 % option 0.0 % Electrical connection Male and female plug ISO 4400 Male plug Binder series 7 (5-pin) 0 0 0 0 Cable outlet with PVC cable Cable outlet Male plug Mx (4-pin) / metal T A 0 T R 0 M 0 Compact field housing stainless steel.405 Mechanical connection G/" DIN 85 G/" EN 87 G/4" DIN 85 G/4" EN 87 /" NPT Seals FKM EPDM NBR Special version standard 4 8 5 0 9 9 0 0 0 0 0 0 4 0 0 N 0 0 9 9 measurement starts with ambient pressure standard: m PVC cable without ventilation tube (permissible temperature: -5 70 C), optionally without ventilation tube cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, permissible temperature depends on kind of cable, price without cable 4 possible for nominal pressure ranges P N 60 bar 5 BD SENSORS GmbH BD-Sensors-Straße Telefon +49 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Telefax +49 (0) 9 5 / 98 - info@bdsensors.de 0 0 0 9 9 007 list contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice. This price li