ATS22C14Q meki upuštač ATS22 upravljanje 220V-snaga 230V (37kW)/ V(75kW)

Similar documents
ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV71HU75M3Z frekv.pretvarač promj.brzineatv71 7,5 kw 10 KS 240 V filtar EMC bez graf.priklj

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

ATV212HD18N4 variable speed drive ATV kW - 25hp - 480V - 3ph - EMC - IP21

ATV212WU40N4 variable speed drive ATV212-4kW - 5hp - 480V - 3ph - EMC class C2 - IP55

ATV212HD11N4 variable speed drive ATV212-11kW - 15hp - 480V - 3ph - EMC - IP21

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

LXM32AD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATV61HC11N4 SPEED DRIVE 150 HP 460 V ATV61

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM35TF V AC

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV212WD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC class C2 - IP55

ATV212HU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC - IP21

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV32H018M2 variable speed drive ATV32-0,18 kw V - 1 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV61QC31N4 variable speed drive ATV61Q - 315kW / 500HP V - IP20

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

ATV61HU55M3 ATV61 5,5 kw 7,5HP 240V single phase EMC IP20

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

ATV212WU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC class C2 - IP55

ATV212HD15N4 variable speed drive ATV212-15kW - 20hp - 480V - 3ph - EMC - IP21

RM35LM33MW liquid level control relay RM35-L V AC/DC

TM3DI16 module TM3-16 inputs

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

ATV71QC16N4 variable speed drive ATV71Q - 160kW / 250HP V - IP20

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

ATV212HD75N4. Main. Range of product Altivar 212. Device short name. Motor power hp 160 A 460 V khz with derating factor

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

ATV340D18N4E variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

ATV212HD15N4 variable speed drive ATV212-15kW - 20hp - 480V - 3ph - EMC - IP21

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

TM258LF42DT compact base M I/O - 24 V DC - CANopen

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

ATV212HD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC - IP21

TM258LD42DT4L compact base M I/O - 24 V DC

ATV630D15N4 variable speed drive ATV630-15kW/20HP V - IP21/UL type 1

RM4JA01F current measurement relay RM4-J - range ma V AC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

ATV212HU15N4. Main. Range of product Altivar 212. Device short name 3.7 A 460 V khz adjustable

ATV212HD11M3X variable speed drive ATV212-11kW - 15hp - 240V - 3ph -wo EMC - IP21

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

RM17UB3. Price* : USD

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Transcription:

Podatkovni list proizvoda Karakteristike ATS22C14Q meki upuštač ATS22 upravljanje 220V-snaga 230V (37kW)/400...440V(75kW) Komplementarno Assembly style Function available Supply voltage limits Glavno Range of product Altistart 22 Product or component type Product destination Product specific application Component name Network number of phases Soft starter Asynchronous motors Pumps and fans ATS22 3 phases [Us] rated supply voltage 230...440 V - 15...10 % Motor power kw Factory setting current Power dissipation in W Utilisation category Type of start IcL starter rating IP degree of protection With heat sink Internal bypass 195...484 V Supply frequency 50...60 Hz - 10...10 % Network frequency Device connection [Uc] control circuit voltage Control circuit consumption Discrete output number 2 Discrete output type Minimum switching current Maximum switching current Discrete input number 3 Discrete input type Discrete input voltage Discrete input logic Output current PTC probe input Communication port protocol Connector type Communication data link Physical interface Transmission rate 45...66 Hz In the motor supply line To the motor delta terminals 230 V -15...10 % 50/60 Hz 20 W 37 kw 230 V 75 kw 400 V 75 kw 440 V 131 A 82 W for standard applications AC-53A Start with torque control (current limited to 3.5 In) 140 A connection in the motor supply line for standard applications IP00 Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O 100 ma 12 V DC relay outputs 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs Logic LI1, LI2, LI3 5 ma 4.3 kohm 24 V <= 30 V Positive logic LI1, LI2, LI3 < 5 V and <= 2 ma > 11 V >= 5 ma 0.4...1 Icl adjustable 750 Ohm Modbus 1 RJ45 Serial RS485 multidrop 4800, 9600 or 19200 bps 1 / 8 Informacije dane u ovoj dokumentaciji sadrže opće opise i/ili tehničke karakteristike o performansama ovdje sadržanih proizvoda. Ova dokumentacija nije namijenjena kao zamjena za niti bi se trebala koristiti za određivanje prikladnosti ili pouzdanosti predmetnih proizvoda za konkretne korisničke primjene. Svaki takav korisnik ili integrator dužan je provesti odgovarajuću i potpunu analizu rizika, procjenu i ispitivanje proizvoda u odnosu na odgovarajuću specifičnu primjenu ili uporabu istog. Niti društvo Schneider Electric Industries SAS niti bilo koje od njegovih povezanih poduzeća ili podružnica neće preuzeti obvezu ili snositi odgovornost za pogrešnu upotrebu ovdje sadržanih informacija.

Installed device 31 Protection type Marking Type of cooling Operating position Height Width Depth Product weight Power range Motor starter type Thermal protection motor Phase failure line Thermal protection starter CE Forced convection Vertical +/- 10 degree 356 mm 150 mm 229.5 mm 18 kg 30...50 kw at 200...240 V 3 phases 55...100 kw at 380...440 V 3 phases Soft starter Okolina electromagnetic compatibility Conducted and radiated emissions level A IEC 60947-4-2 Damped oscillating waves level 3 IEC 61000-4-12 Electrostatic discharge level 3 IEC 61000-4-2 Immunity to electrical transients level 4 IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 Voltage/current impulse level 3 IEC 61000-4-5 standards EN/IEC 60947-4-2 product certifications CCC CSA C-Tick GOST UL vibration resistance 1 gn 13...200 Hz EN/IEC 60068-2-6 1.5 mm 2...13 Hz EN/IEC 60068-2-6 shock resistance 15 gn 11 ms EN/IEC 60068-2-27 noise level 56 db pollution degree Level 2 IEC 60664-1 relative humidity 0...95 % without condensation or dripping water EN/IEC 60068-2-3 ambient air temperature for operation ambient air temperature for storage -25...70 C operating altitude -10...40 C without derating > 40...< 60 C with current derating 2.2 % per C <= 1000 m without derating > 1000...< 2000 m with current derating of 2.2 % per additional 100 m Offer Sustainability Green Premium product Compliant - since 0938 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Available Available Green Premium product Compliant - since 0938 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Available Available Contractual warranty Warranty period 18 months Frame Size C Dimensions 2 / 8

Precautions Standards The Altistart 22 soft starter is compliant with pollution Degree 2 as defined in NEMA ICS1-1 or IEC 60664-1. For environment pollution degree 3, install the Altistart 22 soft starter inside a cabinet type 12 or IP54. Air Circulation DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH ATS22 soft starters are open devices and must be mounted in a suitable enclosure. Failure to follow these instructions will result in death or serious injury. Leave sufficient free space to help the air required for cooling purposes to circulate from the bottom to the top of the unit. Overheating To avoid the soft starter to overheat, respect the following recommendations: Mount the Altistart 22 Soft Starter within ± 10 of vertical. Do not locate the Altistart 22 Soft Starter near heat radiating elements. Electrical current through the Altistart 22 Soft Starter will result in heat losses that must be dissipated into the ambient air immediately surrounding the soft starter. To help prevent a thermal fault, provide sufficient enclosure cooling and/or ventilation to limit the ambient temperature around the soft starter. 3 / 8

If several soft starters are installed in a control panel, arrange them in a row. Do not stack soft starters. Heat generated from the bottom soft starter can adversely affect the ambient temperature around the top soft starter. Mounting Connection Between the Fan and the Altistart 22 Soft Starter 1 Altistart 22 Soft Starter 2 Fan Wall mounted or Floor-standing Enclosure with IP 23 Degree of protection Introduction To help proper air circulation in the soft starter, grilles and forced ventilation can be installed. Ventilation Grilles Forced Ventilation Unit Power Terminal Bar Style 4 / 8

Power supply and output to motor Bar b 20 mm (0.79 in) a Bolt Cable and protective cover Size Gauge Protective cover Tightening torque 5 mm (0.2 in) M8 (0.31 in) 95 mm² 250 MCM LA9F702 18 N.m 157.5 lb.in Power connections, minimum required wiring section IEC cable mm² (Cu 70 C/158 F) (1) UL cable AWG (Cu 75 C/167 F) (1) 50 2/0 230 Vac control, logic Inputs (LI) 24 Vdc, 3-wire control With Line Contactor, Freewheel or Controlled Stop 230 Vac control, logic Inputs (LI) 24 Vdc, 2-wire control,freewheel stop 5 / 8

Connection in the motor delta winding in series with each winding Wiring ATS22 soft starters connected to motors with the delta connections can be inserted in series in the motor windings. The following wiring requieres particular attention. It is documented in the Altistart 22 Soft start - soft stop unit user manual. Please contact Schneider Electric commercial organisation for further informations. Example A 400 V - 110 kw motor with a line current of 195 A (nominal current for the delta connection). The current in each winding is equal to 195/1.5 or 130 A. The rating is determined by selecting the soft starter with a permanent nominal current (ICL) just above this current. Motor Thermal Protection - Cold Curves Curves 6 / 8

A Class 10 B Class 20 C Class 30 Trip time for a Standard Application (Class 10) 32 s Trip time for a Severe Application (Class 20) 63 s Trip time for a Severe Application (Class 30) 95 s Motor Thermal Protection - Warm Curves Curves 7 / 8

A Class 10 B Class 20 C Class 30 Trip time for a Standard Application (Class 10) 16 s Trip time for a Severe Application (Class 20) 32 s Trip time for a Severe Application (Class 30) 48 s 8 / 8