User Manual. Recorder of environmental conditions THBR. Version: 2.0.2

Similar documents
User Manual. Computer Program Pomiar Win. Version: 4.0.X. Manual number: ITKU A MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

Veco User Guides. Grids, Views, and Grid Reports

Superview INSTRUCTIONS. Version 2.0x

INSTALLING THE PS3 XBOX READY SOFTWARE:

Medivators Data Management Software Installation / User Manual

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

Operating Instructions / User manual. IRSoft. Version 2.0. Documentation software for ERSA Rework Systems. ERSA GmbH

User Manual SmarTach T-Store

User Manual PDUTracker

myreports User Guide A31003-P3010-U

Backup Recording Viewer for NS

irc Pro (Not for diagnostic use)

CITO2 Installation & User Instructions

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1

Symantec Backup Exec Quick Installation Guide

BESTCOMSPlus Software

Trademark. Cadex C5100 BatteryStore v1.5 User Guide

Version: 01P02B. U3 Map Maker Operational Guide

TEMPERATURE AND HUMIDITY REGISTERING DEVICE MANUAL

LedCenterM Software Operation Manual (AniView 3000)

FX Tools Software Package - FX CommPro N2 User s Guide

User Manual MPPTracker

SolarPower Pro. User s Manual. Management Software for Solar Inverter

Instruction Manual XLComm Data Acquisition Software For XL Series Meters

User Manual. MPPTracker. Management Software for Solar Charge Controller. Version: 1.2

M-BUS AMR SOFTWARE LorusTask Ver OPERATION MANUAL

A-Scan Manager. Quick Reference Guide. Rev 1.04

Server Edition. V8 Peregrine User Manual. for Microsoft Windows

Trademark. Cadex C5100 BatteryStore User Guide

Getting Started with the IntelleView POS Operator Software

USB Instruments EasyLogger for PS40M10 "Swordfish" Help

SI-100 Digital Microscope. User Manual

Power Vision 1.5 (Cod )

ViewPower Pro. Software. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Rev T 237

User Manual WatchPower

Server Edition USER MANUAL. For Microsoft Windows

Instruction manual. testo easyemission Software

ATS System Monitoring Software ATS

RMS Monitoring Software System Operation

Intelli-Signage Signage Designer Software

U3 Encryption Utility User Guide

Remote ialarm Center. User s Manual

Products that are referred to in this document may be trademarks and/or registered trademarks of the respective owners.

PropertyBoss Upgrade

User Manual. Thermo Scientific Orion

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

Centralised monitoring software. (version v2.35) Program installation and configuration

Operating Instructions METTLER TOLEDO Calibry Software for Pipette Calibration Calibry

nfax 5.0 OceanFax User s Guide

RESmart npap Data Statistics Software. User Manual. Solutions in Sleep Therapy.

USER MANUAL. PowerFrame TM Personal. UPS Monitoring Software

ViewPower Pro. User s Manual. Management Software for Uninterruptible Power Supply Systems

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

KYOCERA Net Admin User Guide

SWC1090 configuration software for G.M. International Isolators series D1000 and E1000. Installation and use manual

Intellicus Getting Started

USER MANUAL FOR. Nano-Checker 710 THE PIONEER AND CONSISTENT INNOVATOR FOR IN VITRO DIAGNOSTICS

Frequency tables Create a new Frequency Table

9936A LogWare III. User s Guide. Revision

New User Orientation PARTICIPANT WORKBOOK

Synergy Application Software

UPGRADE INSTRUCTIONS

SCREEN RECORDER KD-Series TYPE

USER MANUAL. LG Simple Editor.

PAAS Lifestyle Coach

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

SOFTWARE USER S GUIDE

WinQbase / Caliber. Getting started

Kingston SecureTraveler User Guide

Procom PPC Software User s Manual

User Manual WatchPower

LEDsynergy Sign Control Software Advanced Software Operation Manual Version: The Communication Method for Your Software is:

Quick Start Guide (V1.03) UD.6L0201B1064A01

Operating Manual. Version 7.3.4

BackupVault Desktop & Laptop Edition. USER MANUAL For Microsoft Windows

EasyBuilder Pro Installation and Startup Guide

RMS Monitoring Software System Operation

DriveWizard Plus Instruction Manual

INSTRUCTIONS MANUAL V2.9x B

Calendar & Buttons Dashboard Menu Features My Profile My Favorites Watch List Adding a New Request...

User s Manual. Management Software for Uninterruptible Power Supply Systems

ANALYSIS SOFTWARE. CAmReport

Paragon Exact Image. User Manual CONTENTS. Introduction. Key Features. Installation. Package Contents. Minimum System Requirements.

Introduction. Summary. Otasuke GP-EX! Introduction Summary. Intro-21. Development Environment Intro-4. Procedures of Creating New Screen

BST-DL114 / BST-DL115/BST-DL116/BST-DL117 Wireless Monitor Temperature Humidity Data Logger. Manual V1.0

SNMP Web Management. User s Manual

testo Comfort Software Professional 4 Instruction manual

Chapter 2: Clients, charts of accounts, and bank accounts

3M Molecular Detection System Software Upgrade/Installation Instructions

Copyright 2017 Xi'an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

testo easyheat Configuration and Analysis software Instruction manual

LID1265 Custom names uploader

Instructions for Use

Grain Tracker Operators Manual

HD32MTLogger Software Manual for the instrument HD32MT.1 Introduction

Temperature And Humidity Recorder-Operating Instruction. Product Overview. Notes - 1 -

C-322. Model. Instruction Manual. Datalogging Sound Level Meter. reedinstruments. www. com. Tripod sold separately (Model BS-6)

Welcome 1. Precaution

Transcription:

User Manual Recorder of environmental conditions THBR Version: 2.0.2

2

TABLE OF CONTENTS 1. INTENDED USE... 4 2. INSTALLATION... 5 2.1. System requirements... 5 2.2. Installation process... 5 2.3. Program upgrade... 8 3. DEVICE SETUP... 9 4. STARTING PROGRAM... 10 5. MAIN PROGRAM WINDOW... 12 5.1. Description... 12 5.2. Closing the program... 13 6. PROGRAM MENU... 14 6.1. Settings... 14 6.1.1. Language... 17 6.1.2. About the program... 17 7. CHARTS... 18 8. ARCHIVE... 18 8.1. Report on measurements... 20 8.2. Measurements chart... 22 8.3. Table of measurements... 23 9. TECHNICAL DATA... 26 3

1. INTENDED USE The recorder of environmental conditions THBR is a system designer for monitoring environmental conditions for indoor applications. The system measures temperature related humidity of air and atmospheric pressure. All the meteorological data mentioned above are read and saved continuously by software. On the basis of measurements air density and saturation point temperature are calculated for every monitored room. Basic program functions: current (continuous) read and archiving of environmental parameters: atmospheric pressure, humidity, temperature, generating and archiving charts of humidity, temperature and atmospheric pressure versus time, the possibility of entering critical parameters of environmental conditions, which if exceeded the user is warned, printout of reports from measurements, language versions of GUI: Polish, English, German. Caution: 1. Due to the continual updates, there is a possibility of minor discrepancies between the contents of this manual and the program. 2. RADWAG takes no responsibility for the unexpected effects of program operation and possible consequences resulting from the wrong use of the program. 4

2. INSTALLATION 2.1. System requirements Minimal configuration: Processor INTEL or AMD 2000MHz or faster, 1 GB RAM, Graphic card SVGA (resolution at least 1024x768 pixels with 24-bits colour palette), Communication port USB, HD 50 GB or larger, Computer mouse, Keyboard, Colour monitor with resolution 1024x768, Operation System Windows XP/Vista/7, Environment Microsoft.NET Framework 2.0, Printer (A4), 2.2. Installation process In order to install the program put you installation CD into the CD-ROM drive. The THBR installation wizard should start automatically. If the installation needs to be started manually run program <THBR_Install_X.X.X.exe> in the main folder of the installation CD. After running the program the following dialogue window appears with the possibility of choosing the language to be used during the installation: Choose the language and press OK. 5

In further steps follow the instructions displayed in subsequent windows. Welcome window: In order to continue press Next. Window of creating shortcuts to the program: Options: according to your preferences tick choosen fields. In order to continue press Next. 6

Ready-to-install window: In order to continue press Next. Installing components: 7

Completing installation window: When the field View User Manual.PDF is ticked, after pressing button Finish a PDF manual to this program will be displayed. Caution: For the appropriate operation of the program the Microsoft.NET Framework 2.0. environment needs to be installed. The program installer check out the computer resources and in case of the lack of necessary components installs them automatically. 2.3. Program upgrade In case when a version of THBR program has already been installed and when a user starts the installation of a newer version of the program the installation process will proceed in a similar way. Follow all the appearing instructions according to point 2.2 of this manual. Notice! Before starting the installation program it is advisable to backup the folder where the previous version of the program has been installed. Default path: <C:\Program Files\RADWAG\THBR\>. 8

3. DEVICE SETUP The measurement unit of the environmental conditions recorder THBR is connected to a personal computer via interface USB through the cable accompanied the device. battery supply switch USB RS485 Measurement unit THBR There are modules of THB-2 sensors connected to the recorder. They perform measurements of temperature, humidity and atmospheric pressure. The modules of sensors communicate with the main unit via interface RS 485 so they need to be connected to the RS 485 socket as in the drawing below. Connecting the module of sensors to the main unit 9

For the standard operation of the device the battery switch should be set to position OFF (to the right side). OFF Battery switch Connect the device to the computer after installing the software. In case of problems with establishing communication check the settings of communication port (see chapter 6.1). 4. STARTING PROGRAM The program can be run by pressing the shortcut icon on the desktop provided it has been created. You can also run the program from the Quick launch bar (option to choose during installation). 10

You can always run the program form the Windows START menu: START/Programs/RADWAG/THBR/THBR. 11

5. MAIN PROGRAM WINDOW The main program window is displayed after starting the program: 5.1. Description Title bar displays the name and program version and system buttons manipulating with windows. Function buttons accessing all options and program functions: Information window displays information on current measurements of environmental parameters. 12

Transparency slider sets the transparency ratio of the program window. Clock the place where the current date and time is displayed. Notice: If a computer cannot establish communication with the environmental module then the information window does not show any values. Check the correctness of the connection settings described in section 6.1, and the port USB. 5.2. Closing the program In order to close the program press button main window. in the title bar of the Closing the program is preceded by the dialogue window in order to confirm the action: 13

6. PROGRAM MENU The access to the program menu press button window. in the main program 6.1. Settings Press button this manual and then press. or enter the program menu according to section 6 of On the overlap Connection set port COM to which the device is connected and the baud rate that is set to 115200 by default. 14

After setting the connection parameters press button in order to save the changes. Overlap Calibration is accessible only for RADWAG authorized services after entering the right password. On overlap Archive set the time of collecting and time of segregating measurements as well as limit values of environmental parameters. 15

Fields: Archive measures - Ticking this field enables recording parameters in the program database. Interval [s] - The time during which measurements are saved in the database. Segregation time - Mode of segregating measurements in the database. Changing this option causes the system of creating files of database. Data can be segregated according to options: All together, Daily, Weekly, Monthly Notice: The change in segregating data causes creating a new empty database to which old measurements are not moved. Setting the threshold parameters allows for showing the reference levels for minimum and maximum values of measurements presented in the window together with the chart and report. The top and bottom limit of the parameter can be enabled/disabled by clicking on the right side of the choosen window. Limit enabled Limit disabled After setting archiving parameters press button changes. in order to save Notice: After opening the configuration window the main window is locked. 16

6.1.1. Language Press button or enter the program menu according to section 5 of the manual and press button. In menu item Language you can set the GUI language, after choosing the language press Save and restart the program in order to apply the changes. 6.1.2. About the program Press button or enter the program menu according to section 6 of the manual and press button. Menu item About displays a window including name, version and license information concerning the program. Press Esc to close the window. 17

7. CHARTS In the window all measurements are displayed. In order to start the window with the chart of measurements refreshed in real time, press button in the main program window. Notice: After changing the bottom or top limit of the parameter described in section 6.1 of this manual restart the chart window to apply the change. 8. ARCHIVE In the window of archived measurements users have an insight into performed measurements of environmental parameters together with charts. Additionally reports from saved data can be printed. 18

In order to start the archive window press button window. in the main program In this window performed measurements can be viewed after selecting the appropriate database and pressing button. Then a progress bar is displayed. The button Print report is enabled after all measurements are subtracted from the archive. 19

8.1. Report on measurements After pressing button be printed. a report from measurements can The report on measurements of environmental parameters: 20

Report menu In the window of reports, using the menu bar or item File, users can choose from advanced options. Menu items: Page Setup - Print Print Printout options e.g. type and size of paper, margins, page position. - Advanced printing - Printing the report on a default printer. Export Document - Exporting the report to a file in a choosen format (pdf, html, mht, rtf, xls, csv, txt, bmp, jpg, other). Send via E-Mail - Sending the report by e-mail using one of a chosen file formats ( pdf, html, mht, rtf, xls, csv, txt, bmp, jpg, other). Exit - Closing the window of reports. 21

8.2. Measurements chart Overlap Chart allows for opening the window with measurements from the selected database. 22

8.3. Table of measurements On overlap Grid all measurements from the selected database are displayed The status of measurement can be displayed after ticking field. Measurement status: - Correct - Over the set threshold - Below the set threshold 23

In the bottom part of the window Count there is the number of all measurements from the selected database displayed. In the bottom part of the window there is the average value for each column displayed. On overlap Table the measurements can be sorted and filtered. Filtering Press button to choose an appropriate criterion of filtering. Sorting Sorting can be started after pressing the top bar of the column or from the menu. The sorting mode is signalled by the changing pictogram: Menu After right-clicking on a column an extended pop-up menu appears. 24

Items: Sort Ascending - Sort Descending - Clear Sorting - Sorts in ascending way of the given column, Sorts in descending way of the given column, Cancelling the sorting procedure for the given column, Group By This Column * - Groups the displayed rows according to the indicated column. Group By Box - Remove This Column Column Chooser - Enables the grouping field to which you can drag headings of columns, - Removes the column form displaying, Enables the adjustment window from which you can drag removed columns, Best Fit - Automatic column sizing, Filter Editor - Best Fit (all columns) Starts the filter wizard with advanced options, - Automatic sizing of all columns, Show All * - Shows grouped items, Hide All * Cancel Grouping * - - Hides grouped items, *) options enabled while grouping is active Deletes grouping, accessible after indicating a field of grouping. 25

9. TECHNICAL DATA This table holds technical parameters of the environmental module: Range of measuring temperature -10 C 85 C Accuracy of measuring d=0.01 C, error +/- 0.2 C temperature Range of measuring pressure 850 1050 hpa Accuracy of measuring pressure d = 0.1 hpa error +/- 1 hpa Range of measuring humidity 0 100% Accuracy of measuring humidity d = 0.1 % error +/- 2 % Working temperature -10 40 C Casing Plastic Power Supply 5 V DC - USB Interface PC USB Connection to modules of RS 485 sensors Dimensions in mm without the 131 68 34 handle Weight 0.75kg 26