Pneumatic Control/Feedback

Similar documents
Pneumatic Control/Feedback

Pneumatic Control/Feedback

Control Head for the integrated mounting on process valves

Pneumatic Control Unit for the integrated mounting on process valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Control Head for the integrated mounting on process valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Control Head for the integrated mounting on process valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Control head for decentralized automation of ELEMENT process valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process

Digital electropneumatic Positioner SideControl

Digital electropneumatic positioner SideControl

Digital electropneumatic positioner

Digital electropneumatic positioner

Digital electropneumatic Process Controller

Digital electropneumatic positioner

Control head for hygienic process valves

SideControl Positioner

Operating pressure (bar) kv factor (m 3 /h) *3)

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

21023, 21025, 2/2 Direct solenoid actuated poppet valves

Series 95000, 2/2 Direct solenoid actuated poppet valve

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Operating pressure. N/en/en

HERION SERIES Indirect solenoid actuated spool valves

Inductive sensor NI3-EG08K-Y1-H1341

26360, NAMUR. Technical data

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Inductive sensor BI1.5-EG08-Y1-H1341

Operating pressure. N/en/en

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

Electromotive process valve - 2 way angle-seat shut-off valve

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

24011 series, 3/2 Direct solenoid actuated poppet valve

Inductive sensor BI1.5-EG08-Y1-H1341

T EN TROVIS Electropneumatic Positioner

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Digital Positioner 8049

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Technical Data. General specifications. Rated operating distance s n 3 mm

Pressure sensors SDE3, with display

80265 series, 3/2 Indirect solenoid actuated poppet valve

Flow. Flow. N/en

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves

Inductive sensor BI5-EM18-Y1X-H1141

Electromotive process valve - 2 way shut-off globe valve

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Technical features. 12/ f. N/en

Operating pressure (bar)

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Installation kits for hygienic process valves

Series 3730 Type Electropneumatic Positioner

Terminal Boxes Series 8118

Material Seat seal. N/en

Sensor boxes SRBG Key features

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Type 8694 Positioner TopControl Basic. Quickstart. English Deutsch Français

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Technical features. N/en

LS 6600 Technical Datasheet

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Series 3730 Type Electropneumatic Positioner

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Flow sensors SFAB Key features

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Inductive sensor with analog output BI15-M30-LI-EXI

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Float Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Sensor boxes SRBE Key features and product range overview

Temperature Switches

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

OPTISWITCH 6600 C Technical Datasheet

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Fieldbus Gateway Type ME43

Datasheet - RSS 36-D-R-ST

Transcription:

897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G approval Type 00 Angle seat valve Type 0 Globe seat valve Type 0 Diaphragm valve Type 000 Angle seat valve The pneumatic control unit Type 897 is optimized for integrated mounting on the ELE- MENT XX process valve and CLASSIC 0XX series. Mechanical or inductive limit switches register the position of the valve. The integrated pilot valve controls single or doubleacting actuators. The design of the control unit and the actuator enables an internal control air routing without external tubings. Besides the electrical position feedback signal the status of the device is shown directly on the control unit itself via LEDs. The housing is easy to clean and features proven IP protection and chemically resistant materials for use in hygienic processing, in food, beverage and pharmaceutical industries. Combined with Bürkert ELEMENT actuators the unique pilot valve system enables a compressed air recycling that avoids actuator chambers contamination from the environment. * Supply voltage according to UL NEC Class for versions with culus approval. ) The supply pressure has to be 0. - bar above the minimum required pilot pressure for the valve actuator. Technical Data Material - Body Cover Sealing Operating voltage * Pilot valve Micro switch Initiator Control medium Dust concentration Particle density Pressure condensation point PPS PC EPDM V DC ±0% - residual ripple 0%, consumption W V Version: 0 8 V AC/DC, max. A 0V Version: 0 0 V AC/DC, max. A 0 to 0 V DC - max.00 ma per initiator neutral gases, air, quality classes acc. to ISO 87- Class 7: max. particle size 0 μm Class : max. particle density 0 mg/m³ Class : max. -0 C or min. 0 C below the lowest operating temperature Class X: max. mg/m³ Oil concentration Supply pressure to 7 bar ) Pilot air ports Threaded ports G /8 or push-in connector (tube Ø mm / / ) Position feedback x micro switch (0 8 V AC/DC, max. A) x micro switch (0 0 V AC/DC, max. A) x initiator ( V DC), PNP shutter -wire with LEDs x initiator NAMUR (8, V DC) (-wire) with LEDs x initiator ( V DC), Schließer (-wire) with LEDs Stroke range valve spindle Ambient temperature with/without pilot valve with/without pilot valve with pilot valve without pilot valve to mm Installation Protection type Protection class acc. to DIN EN 0 Conformity EMC directive 0/0/EU Ignition protection II D Ex tc IIIC TºC Dc II G Ex na IIC T Gc II D Ex ia IIIC TºC Db IP II G Ex ia IIC T Gb Approval Electrical connection Multipole 0 to +ºC (II D Ex tc IIIC TºC Dc, II G Ex na IIC T Gc) 0 to +ºC (II D Ex ia IIIC T C Db IP, II G Ex ia IIC T Gb) -0 to +ºC (without ATEX or for II G Ex ia IIC T Gb) -0 to +0ºC (without ATEX or for II G Ex ia IIC T Gb) as required, preferably with actuator in upright position IP and IP7 according to EN 09, Type X culus certifi cate no. E879 M, 8-pole Mx. SW (cable 0. bis. mm² -8 mm), terminal screws p. /8

897 Ordering information for process valve system with integrated pneumatic control unit A complete process valve system consists of a pneumatic control unit Type 897 and a process valve Type ELEMENT XX or CLASSIC 0XX. The following information is necessary for the selection of a complete system: Item no. of the desired pneumatic control unit Type 897 (see Ordering chart) Item no. of the selected process valve Type XX or Type 0XX If you order two components, you receive a complete assembled and certified valve. When you click on the orange box "More info." below, you will come to our website for the resp. product where you can download the datasheet. Example for process valve systems Unit Type 897 Desired process valve, example 00 Angle-seat valve 0 Diaphragm valve 000 Angle-seat valve Complete process valve system Process valve system On/Off ELEMENT Type 880-YE-U 00+897 Process valve system On/Off ELEMENT Type 880-DF-U 0+897 Process valve system On/Off CLASSIC Type 880-YA-U 000+897 p. /8

Ordering chart (other versions on request) End position feedback 897 Item no. Inductive Switch -wire PNP Inductive Switch -wire NAMUR Inductive Switch -wire V DC Micro Switch V DC Micro Switch 0-0V AC/DC Feedback status LEDs Electrical connection ATEX / IECEx Cat. D/G Zone / ) ATEX / IECEx Cat. D/G Zone / ) ATEX/ IECEX Cat. G Zone ) culus Pilot air ports threaded ports Actuator series ELEMENT Type XX Actuator series CLASSIC Types 0XX Unit (pilot valve / way, single acting NO/NC) yes yes G/8 8 8 na yes yes G/8 / M na 8 89 yes yes G/8 87 na yes yes G/8 / M na 8 yes yes G/8 89 na yes yes G/8 / M na 8 M connector yes yes G/8 8 88 na yes yes G/8 / M na 8 80 yes yes G/8 8 8 na yes yes G/8 / M na 8 8 yes yes G/8 8 na yes yes G/8 / M na 8 yes yes G/8 8 8 na yes yes G/8 / M na 8 88 yes yes G/8 8 na yes yes G/8 / M na 8 M Multipole yes G/8 0 78 na Without end position feedback yes G/8 0 79 na yes G/8 0 80 na Feedback (without pilot valve) yes yes G/8 8 8 na yes yes without na 8 87 yes yes G/8 8 na yes yes without na 8 yes yes G/8 87 na yes yes without na 88 M connector yes yes G/8 0 7 na yes yes without na 0 7 yes yes G/8 8 80 na yes yes without na 8 8 yes yes G/8 80 na yes yes without na 8 yes yes G/8 8 80 na yes yes without na 8 8 yes yes G/8 8 na yes yes without na 80 yes G/8 8 8 na yes without na 8 8 yes G/8 8 808 na yes without na 8 8 Note: culus only valid for versions without ATEX approval ) II D Ex tc IIIC T / II G Ex na IIC T Gc ) II D Ex ia IIIC T C Db IP / II G Ex ia IIC T Gb ) II G Ex ia IIC T Gb Approvals FM Additional Feedback switchpoint NPN-coded Push-in pilot air ports (tube Ø mm; / ) p. /8

Ordering chart adapter kit (has to be ordered separately) 897 Description Actuator size Control function Item no. Adapter kit ELEMENT Types XX Adapter kit CLASSIC Types 0XX Unit / Feedback Ø0mm single acting / universal 8 9 Unit Ø0mm single acting 98 7 Unit Ø0mm Seat valve Types 000 / 0 single acting 8 Unit Ø0mm Diaphragm valve Types 00 / 0 single acting 8 8 Unit Ømm ) single acting 8 Feedback Ø0mm universal 98 7 Feedback Ø0//80mm universal 8 Feedback Ø00/mm universal 8 Feedback Ø7/mm universal 8 9 For installation kits to rd party process valves please see datasheet "Installation Kits for hygienic process valves" or contact your sales office for related drawings or individual engineering support ) When combining actuator size Ø mm with 897 CLASSIC reduced switching dynamics should be expected. Please choose Type 890 for shorter response times. Ordering chart accessories Description Item no. M socket, 8-pins, m assembled cable 99 0 M socket, 8-pins, m assembled cable 99 7 Silencer G/8 780 779 Silencer, push-in connector 90 Stroke limitation actuator CLASSIC Ø0/mm 89 Stroke limitation actuator CLASSIC Ø80mm 89 Stroke limitation actuator CLASSIC Ø00/mm 89 Materials Transparent cap PC Basic body PPS Sealing EPDM Plug M PA Brass nickel plated Screws Stainless steel Push-in connector Threaded ports G/8 POM / stainless steel stainless steel p. /8

Dimensions [mm] for mounting on process valve ELEMENT Types XX 897. 7.7.7.7 0. 9 9 0... p. /8

Dimensions [mm] Control Unit for mounting on process valve CLASSIC Types 0XX 897 Ø. 7.7.7.... 0.9 89.9 0. 8. 8. 9 9 0..7 7. Feedback for mounting on process valve CLASSIC Types 0XX 0.. p. /8

Connection options Multipole, plug M 8-pins 897 8 7 Plug configuration with -wire inductive switch, V DC Pin no. Wire Configuration External circuit colour ) white INI Bottom OUT Output Output ( V) brown INI Top OUT Output Output ( V) green INI - () Supply yellow INI + ( V DC) Supply + V DC grey 0/ V 0/ V DC ±0% pink Residual ripple 0% ) The indicated colours refer to the connecting cable available as an accessory (99 0), M x. (cable-ø 0 mm), terminal screws (. mm ) Port configuration with micro switch, V DC / 0 V AC/DC Terminal Configuration External circuit Screw terminals Terminal No Micro switch top Micro switch bottom NO NC Joint connection NO NC Joint connection Port configuration with -wire inductive switch, V DC Terminal Configuration INI + ( V DC) Supply INI Supply INI Top OUT Output INI Bottom OUT Output 0/ V DC External circuit + V DC Output Output 0/ V DC ±0% Residual ripple 0% p. 7/8

Port configuration with -wire inductive proximity switches 897 Screw terminals -wire inductive proximity switches (NAMUR) Terminal Configuration External circuit INI Top + Explosion Non-hazardous protected area area 7) Terminal No INI Top - INI Bottom + INI Bottom - + / / NAMUR- Sensor R +8, V DC 0 V 8) -wire inductive proximity switches, V Terminal Configuration External circuit INI Top + INI Top - INI Bottom + / / load + INI Bottom - + 7) (Acc. to NAMUR recommendation). Please note the prototype test certifi cate from Turck KEMA 0 ATEX 090X 8) Barrier signal, see PTB 07 ATEX 08 To find your nearest Bürkert facility, click on the orange box In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 0/9_EU-en_0089 p. 8/8