Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator Air supply filter Type 00 Angle-seat valve Type 0 Globe valve Type 0 Diaphragm valve Type 000 Angle-seat valve The 890 pneumatic control unit is optimised for integrated mounting on the XX process valve series. Mechanical or inductive limit switches register the position of the valve. The integrated pilot valve controls single or doubleacting actuators. The design of the control unit and the actuator enables an internal control air channel without external tubings. Besides the electrical position feedback signal the status of the device is shown directly on the control head itself. ) The supply pressure has to be 0, - bar above the minimum required pilot pressure for the valve actuator. Technical data Material Body Cover Sealing Operating voltage Pilot valve PPS PC EPDM VDC ±0%, residual ripple 0% (no technical direct current); Consumption W max. VDC, max. A Initiator 0 to VDC, max. 00mA ext. load per initiator According to Fieldbus specifi cation Control medium neutral gases, air DIN ISO 87- Dust concentration Class (<0μm particle size) Particle density Class (<0mg/m ) Pressure condensation point Class (<-0 C) Oil concentration Class (<mg/m ) Supply pressure to 7 bar ) Air input filter exchangeable Mesh aperture ~0,mm Pilot air ports Push-in connector (external Ø mm or /") or threaded ports G/8 Position feedback or x micro switch ( VDC) or x initiator -wires ( VDC) or x initiator NAMUR (8 VDC) (in preparation) Stroke range valve spindle to 8 mm Initiator 7 to 8 mm Ambient temperature 0 to + ºC Installation as required, preferably with actuator in upright position Protection class IP /7 according to EN 09 (NEMAx in preparation) Protection class according to VDE 080 Conformity according to CE in compliance with EMV00/08/EG Type of protection II G na II B T II D td A T II G EEx ia IIC, ATEX (option) Electrical connection Multipole Cable gland M, 8-pole Mx, (cable-ø0mm), terminal screws (,mm ) Approval CSA (in preparation) www.burkert.com p. /
Ordering information for process valve system with integrated pneumatic control unit A complete process valve system consists of a pneumatic control unit Type 890 and a process valve Type xx or 0xx. The following information is necessary for the selection of a complete system: of the desired pneumatic control unit Type 890 (see Ordering chart on p. ) of the selected process valve Type xx or Type 0xx (see separate datasheet for e.g. Types 00, 0, 0 and 000, 0, 0) You order two components and receive a complete assembled and certified valve. When you click on the orange box "More info." below, you will come to our website for the resp. product where you can download the datasheet. Example for process valve systems Pneumatic Control Unit Type 890 Desired process valve, example 00 Angle-seat valve 0 Diaphragm valve 000 Angle-seat valve Complete process valve system Process valve system On/Off ELEMENT Type 880-YE-K 00+890 Process valve system On/Off ELEMENT Type 880-DF-K 0+890 Process valve system On/Off Classic Type 880-YA-K 000+890 p. /
Ordering chart pneumatic control unit Type 890 (other versions on request) Position feedback Pilot air ports Valve function for usage with 0xx actuator 0/mm With cable gland micro switch Push-in connector external ø mm single-acting DN,0 7 7 0 78 double-acting DN,0 7 8 without 79 Threaded ports G/8 Single-acting DN,0 8 Single-acting DN,0 8 Double-acting DN,0 8 9 Without 8 0 7 micro switch Push-in connector external ø mm single-acting DN,0 80 0 Double-acting DN,0 80 0 Threaded ports G/8 Single-acting DN,0 8 With Multipole M micro switch Push-in connector external ø mm Single-acting DN,0 8 0 7 Double-acting DN,0 8 Without 8 0 Threaded ports G/8 Single-acting DN,0 8 0 0 micro switch Push-in connector external ø mm Single-acting DN,0 8 Double-acting DN,0 8 without 8 0 Threaded ports G/8 Single-acting DN,0 8 9 Initiator With cable gland initiator Push-in connector external ø mm Single-acting DN,0 8 97 Double-acting DN,0 8 99 Threaded ports G/8 Single-acting DN,0 8 7 Double-acting DN,0 8 8 Single-acting DN,0 8 0 initiator Push-in connector external ø mm Single-acting DN,0 8 9 Double-acting DN,0 8 98 Threaded ports G/8 Single-acting DN,0 8 With Multipole M initiator Push-in connector external ø mm Single-acting DN,0 8 9 Double-acting DN,0 8 without 8 7 Threaded ports G/8 Single-acting DN,0 8 0 Without 8 8 0 initiator Push-in connector external ø mm Single-acting DN,0 8 8 Double-acting DN,0 8 0 Without 8 Threaded ports G/8 Single-acting DN,0 8 Without With cable gland Without Push-in connector external ø mm Single-acting DN,0 8 9 Approvals CSA Additional Type of protection: II G EEx ia IIC, ATEX or x initiator NAMUR (8 V DC) p. /
Ordering chart adapter kit Description Actuator size Control function Adapter set for Type xx Ø 70 / 90 mm NC / NO / springless (A / B / I) 70 Adapter set for Type 0xx Ø 0 mm NC (A) / NO (B) 7 7 Springless (I) 7 Ø mm NC (A) / NO (B) 7 Springless (I) 7 Ø 80 mm NC (A) / NO (B) 7 8 Springless (I) 7 Ø 00 mm NC (A) / NO (B) 7 9 Springless (I) 7 Ø mm NC (A) / NO (B) 7 0 Springless (I) 7 Ordering chart accessories Description M socket, 8-pins, m assembled cable 99 0 Silencer G/8 780 779 Silencer, push-in connector 90 p. /
Materials Transparent cap PC Basic body PPS Sealing EPDM Cable gland Plug PA M St. st. Screws St. st. Push-in connector Threaded ports G/8 POM/St. st. St. st. Dimensions [mm] Mounting on process valve Type xx Mounting on process valve Type 0xx p. /
Connection options Multipole, plug M 8-pins 8 7 Plug configuration V with micro switch Pin no. Configuration External circuit top (NO) top (NO) top (NO) bottom (NO) bottom (NO) bottom (NO) 0/ V 0/ V DC ± 0 % residual ripple 0 % GND 7 8 not assigned Plug configuration with initiator Pin no. Configuration INI OUT Output INI OUT Output INI - (GND) Supply INI + ( V DC) Supply 0 / V DC GND Cable gland, M x, (cable-ø 0 mm), terminal screws (, mm ) Port configuration V with micro switch Clamp no. Configuration top (NO) bottom (NO) External circuit top (NO) top (NO) bottom (NO) bottom (NO) 0/ V GND 0/ V DC ± 0 % Residual ripple 0 % Port configuration with initiator Clamp no. Configuration INI - (GND) Supply INI OUT Output INI OUT Output INI + ( V DC) Output 0 / V DC GND To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 0909/_EU-en_0089080 p. /