Overview Rated at 12000 VA/12000 Watts, this on-line rack UPS R12000 XR, offers a modular architecture, where each module runs in parallel (total of four 3KVA modules). Customers can choose to use the UPS as a 12KVA UPS, or configure it as a 9KVA UPS in N+1 redundant mode, or 6KVA in N+2 redundant modes. This "N+x" parallel redundant architecture enables customers to adapt to their growing power requirements, and keep their systems powered and protected against bad power. A unique patented wireless paralleling technology built into the R12000 XR eliminates system-level single point of failure by allowing both the logic and the power to be housed in the individual 3kVA module, and not in the enclosure as with most competitive UPSs. With industry leading power density (12000 Watts in 10U of rack space), the R12000 XR provides the highest levels of fault tolerance and power protection for your mission-critical enterprise solutions and rack data-centers. Several options are offered to add flexibility and adaptability to r12000 xr applications: R12000 XR Back Plate Receptacle Kit ERM, R12000 XR Modular PDUs, 40A model SNMP/Serial Port Card 1. Supervisory Bezel 7. Standby Indicator 2. Module 1 8. Test/alarm reset Indicator 3. Module 2 9. Status LED indicators 4. Module 3 10. Enter/Select 5. Module 4 11. 4-way navigation 6. On Switch 12. Excape/de-select DA - 11395 Worldwide Version 10 September 9, 2005 Page 1
Overview Models UPS R12000 XR, N+x, High Voltage (WW) 207552-B22 ERM, R12000 XR Extended Runtime Module, High Voltage (US) 217800-B21 R12000 XR Back Plate Receptacle Kit (w/x2 L6-30R) (US) 325361-001 R12000 XR Back Plate Receptacle Kit (w/x2 IEC309R) (INTL) 325361-B21 Key Features Unity Rated, 12KVA/12KW State-of-the-art "Wireless paralleling" technology Modular design with four 3KVA/3KW independent modules N+x Redundancy and scalability - 12 KW (N+0); 9KW (N+1); 6KW (N+2); 3KW (N+3) Industry leading power density with 10U rack form factor Hot-swappable battery and electronics modules provide ease of maintenance and faster time to repair Ultimate power protection with on-line technology Extended battery service life with energy-dense "pure lead-tin" batteries Easy field upgradeability with flash ROM technology Bundled power management software and Enhanced Battery Management *Site Requirements: Single phase, 200-240 VAC, 100A circuit, Certified electrician to hardwire UPS input/output DA - 11395 Worldwide Version 10 September 9, 2005 Page 2
Product Highlights Superior power conditioning and thermal efficiency with On-line technology and Unity Rating When apparent power (VA) equals true power (Watts), the UPS is said to be unity rated (or power factor correction=unity=maximum efficiency). The unity rated R12000 XR is more efficient, and provides improved power flow and thermal management (vs non-unity rated UPSs). Also, the R12000 XR uses online (also known as the double conversion) technology. The online UPS converts the incoming facility AC power (including sags, surges, spikes, noise) into DC power that feeds the battery. The DC battery output is then converted into clean, filtered, and constant AC voltage output (at a pre-set desired value), ensuring reliable, conditioned power feeding to your connected servers and other IT equipment. High Availability and fault Through a combination of four 3KW/3KVA modules, the UPS R12000 XR meets rigorous redundancy tolerance with "N+x" and fault tolerant requirements - where "x" is the number of reserve modules should a module fail. A Parallel Redundant unique patented state-of-the-art wireless paralleling technology allows all the modules to function architecture independently of each other (each electronics module houses its own electronics and also the logic). Should one of the modules fail then the remaining modules seamlessly redistribute the new load requirement through an automatic load sharing process (with transparent transfer time). And since both the logic and electronics are housed in the each of the individual 3kVA modules (and not in the enclosure as with most competitive UPSs), this technology eliminates system-level single point of failure. Scalable from 3KVA to 12KVA, the UPS R12000 XR allows the following "N+x" parallel redundant configurations: 12 KW (N+0); no module in reserve 9KW (N+1); one module in reserve 6KW (N+2); two modules in reserve 3KW (N+3); three modules in reserve State-of-the-art "Wireless Paralleling" Technology With its high speed Digital Signal Processing (DSP) design, the R12000 XR enables paralleling for redundancy with no inter-module communication. Via a patented wireless paralleling technology, all necessary information for paralleling is available using only the modules' output power wave form. By using a mathematical firmware approach to paralleling for redundancy, wireless paralleling eliminates single points of failure such as in communication wiring and added circuitry between the modules. Therefore, the 100% mathematical firmware is more reliable than traditional paralleling that uses communication wiring between modules. The load share control algorithms maintain synchronization and load balance by constantly making minute adjustments to variations in the output power requirements. In a traditional parallel UPS system, load sharing required communications wiring between the modules, which introduced single points of failure (if any part of the communication link failed, so did the system). The wireless technology in the R12000 XR, eliminates the necessity for inter-module communication. By eliminating communication wiring and added circuitry between the modules, the R12000 XR provides the highest level of reliability and system availability. Unlike traditional paralleling techniques, R12000 XR uses a unique patented wireless technology that eliminates system level single points of failure. By using "peer" configuration, as opposed to "master-slave" configuration, this wireless technology ensures that each module is operating independently. Each module functions autonomously; also, each electronics module houses its own control logic; and the voltage in each individual battery module is individually managed (versus as just an overall battery management). DA - 11395 Worldwide Version 10 September 9, 2005 Page 3
Product Highlights Ease of serviceability through hot-swappable battery electronics modules, and Flash ROM technology The R12000 XR has modular design architecture, consisting of four independent 3KVA modules. And each module is hot swappable. Further, a built-in automatic bypass feature ensures continuous power to your connected load even while the modules are being replaced. The Flash ROM technology provides easy field upgradeability of the firmware while load remains powered up. Ease of maintenance and serviceability Faster time to repair Automatic and manual bypass Increased flexibility through modular design Increase battery back-up time with up to two Extended Runtime Modules UPS R12000 XR supports a maximum of two Extended Runtime Modules (ERM), to further increase your battery back-up time, should you have a sudden brief power outage. Each ERM is 4U high, and consists of two battery packs. When operating at the HP recommended 80% load, each ERM will extend the available battery back up time by up to 15 minutes. For more information on battery back up times, please refer to the Back-up Times Chart. Add flexibility with the R12000 XR Back Plate Receptacle Kit This accessory kit provides customers with an interface to easily plug-in up to two devices or PDUs (power distribution units) with L6-30 or IEC309 connectors to their UPS. Typical applications include the EVA and p-class blade servers. This Back Plate Receptacle kit needs to be hardwired to the UPS. In conjunction with the Back Plate Kit, one additional PDU may also be hardwired to the UPS if needed. Support for up to two Power Distribution Units Up to two Power Distribution Units (PDUs) may be hardwired to the R12000 XR. The UPS ships with one 40A PDU; and additional PDUs may be purchased based on specific customer needs. For more information on these PDUs, please refer to the R12000 XR Options section of this document. Compatible with the SNMP/Serial Port Card Allows network communications, including network power diagnostics, power event alerts, and remote UPS reboot and testing. IMPORTANT: Please NOTE that you must download the new Rack and Power Manager software to use this card with the UPS r12000xr. Remote Emergency Power Off Feature R12000 XR includes an isolated REPO (Remote Emergency Power Off) port. The REPO feature allows the power to the UPS outlets to be switched off from a remote location. For more information, refer the R12000 XR users manual/guide shipped with the unit. Superior Battery Management HP UPS R12000 XR incorporates Enhanced Battery Management: an exclusive, patented technology that doubles battery service life, optimizes battery recharge time, and provides advance notice of pending battery failure. With Enhanced Battery Management, you have a lower total cost of ownership and receive the best in the industry protection for your critical equipment. Also, the R12000 XR uses superior "pure lead-tin" batteries that provide extended battery shelf life to up to 5-7 years. DA - 11395 Worldwide Version 10 September 9, 2005 Page 4
Product Highlights Site Planning and Requirements Customers are strongly advised to refer to the R12000 XR Site Planning Tool (available on http://www.hp.com/products/ups), to make sure that their site is prepared for the installation of the R12000 XR. UPS R12000 XR requires a single phase, 200-240 VAC facility. Both the input and the output ends of the UPS need to be hardwired by a certified electrician. In addition, any optional ERMs and/or PDUs must be hardwired to the UPS by a licensed electrician. The unit will need a 100A circuit with over current protection. Also, the unit weighs 420lb, so it is advised that the facility shipping/receiving and installation teams be notified prior to the unit being delivered. This is further detailed in the r12000 xr Site Planning tool posted on http://www.hp.com/products/ups. An optional R12000 XR installation service is also available. For additional information on this service, please refer to the Services section below. Compatibility Compatible with HP servers, storage, racks (10000, 9000, 7000 series), rack options, and other rack mountable HP equipment (equipment should be compatible with IEC 320 C13/C14 or IEC 320 C19/C20 or L6-30 or IEC309 connectors). The site should have single phase, 100A circuit, 200-220 volts AC power. DA - 11395 Worldwide Version 10 September 9, 2005 Page 5
Service and Support, HP Care Pack, and Warranty Information Warranty Standard three year warranty with first year including parts and labor. HP UPSs are backed by a standard three year limited warranty; 3 year parts, 1 year Labor, 1 year onsite. Optional UPS HP Care Pack and packaged services are also available for purchase. You can choose the precise level of support based on your needs, from basic to business critical. Pre-Failure Battery Warning and Its associated Warranty. The Pre-Failure Battery Warning is proactively detected and notified by a LED indicator light, showing that the battery needs to be replaced. This notice is given 30 days prior to the battery failure. This indicator provides ample time to order a spare battery (1-800-OK-COMPAQ). Avoid storing battery spares as a back up because of short shelf life of the battery. The battery warranty coverage is 3 years for parts. The warranty for the first year of ownership includes parts and labor. Warranty, standard on all HP Uninterruptible Power System (UPS) units, extends the advantage of a HP three-year limited warranty by applying it to the battery before it actually fails. Specifically, the Pre-Failure Battery Warranty ensures that when customers receive the notification from their HP UPS that the battery may fail, the battery is replaced free of charge under the warranty. HP maintains the highest standards in the industry, as evidenced by the HP Pre-Failure Battery Warranty. In addition, HP UPSs are covered by a $25,000 equipment protection guarantee. Should your connected equipment get damaged due to a UPS failure, then your damaged equipment is covered to up to $25,0000. This applies only if: A qualified electrician properly wires the UPS to utility power; UPS installation complies with all applicable electrical and safety codes specified by the National Electrical Code (NEC); UPS is used under normal operating conditions. Users must comply with all instructions and labels specified by HP; UPS is not damaged by accident (other than a utility power transient), misuse, or abuse. NOTE: The $25,000 Equipment Protection Guarantee is offered only in North America. HP Care Pack Installation Hardware Installation (Electronic) HP Care Pack Services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basis to mission-critical. U4696E A full range of HP Care Pack hardware and software services are available including: Installation and start up Education courses Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7 days call window with options including 4-hour response or 6-hour Call to Repair Comprehensive range of software technical support for Microsoft, Linux, ProLiant essentials and VMwarebased IT solutions helping to deliver high level of application availability. Response times range from 30 mins for critical problems to 2 hours. System Management, Performance Services and Mission Critical Support Solution NOTE: For more information on HP Care Pack Services, contact any of our worldwide sales offices or resellers or visit our worldwide web site on the internet at: http://www.hp.com/hps/carepack NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at: http://www/hp.com/hps NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html NOTE: For additional information on Server Services, Rack and Power Options, please visit: http://h20219.www2.hp.com/services/cache/111072-0-0-225-121.html NOTE: The information contained herein is subject to change without notice and is provided "as is" without warranty of any kind. DA - 11395 Worldwide Version 10 September 9, 2005 Page 6
Service and Support, HP Care Pack, and Warranty Information NOTE: The warranties for HP products and services are set forth in the express limited warranty statements accompanying such products and services. DA - 11395 Worldwide Version 10 September 9, 2005 Page 7
Supported Options Extended Runtime Module (WW) 217800-B21 Modular PDU, 40A, 1U/0U, WW, 28 outlets (WW) 252663-B21 Back Plate Receptacle Kit (US) 325361-001 Back Plate Receptacle Kit (WW) 325361-B21 Step down transformer for Converts three phase 400VAC supply to single phase 230VAC and supports a EMEA (Europe, Middle maximum of 12KW load East, Africa) NOTE: To order contact HP/HP Logistics, at +44 1753 608700. 1019899 SNMP/Serial Port Card (WW) 192189-B21 DA - 11395 Worldwide Version 10 September 9, 2005 Page 8
Kit Contents UPS, R12000 XR (P/N 207552-B22) UPS Chassis, x4 Electronics Modules, x4 Battery Modules; x5 Bezel pieces Power Products Documentation CD and Power Management Software CD Rails with mounting hardware; rack template tool (10U); nuts/screws/washers; installation instructions One 40A Power Distribution Unit Option Kit (PN 252663-B21); this PDU offers up to 32 outlets One 12ft (3.7m) communication cable Unit Dimensions Shipping Dimensions Unit Weight Shipping Weight 17.5 x 17.5 x 28.6 in (44.45 x 44.45 x 72.64 cm) 47.1 x 39.1 x 43.7 in (120 x 99 x 111 cm) 420 lb (190 kg) 520 lb (236 kg) ERM, R12000 XR (P/N 217800-B21) ERM chassis, x2 battery packs, front bezel Rails with mounting hardware; rack template tool (4U); nuts/screws/washers; installation instructions UPS-ERM cable set (x3 cable harnesses: positive, negative, ground) ERM-ERM cable set (x3 cable harnesses: positive, negative, ground) Unit Dimensions Shipping Dimensions Unit Weight Shipping Weight 26.5 x 7 x 18.8 in (67.3 x 17.78 x 47.7 cm) 47.1 x 22 x 37.75 in (120 x 56 x 96 cm) 186 lb (84 kg) 271 lb (123 kg) R12000 XR Back Plate Specifications (P/N 325361-001 and 325361-B21) Unit Dimensions Shipping Dimensions Unit Weight Shipping Weight Electrical Output Electrical Input Conformance 7 x 8 x3 in (17.8 x 20.32 x 7.62 cm) 24 x24 x 6 in (60.96 x 60.96 x 15.24 cm) 4.9 lb (2.2 kg) 8.2 lb (3.7 kg) Maximum total current 24A @208VAC; 32A@220VAC draw Overload Protection Yes Output circuit breakers X2 30A breakers Nominal input voltage 200-240VAC Safety agency approvals UL/cUL for NA model UL/cUL CE, NEMKO for INTL model DA - 11395 Worldwide Version 10 September 9, 2005 Page 9
Technical Specifications Electrical Output Electrical Input Battery Online Regulation On battery Regulation Voltage Wave Form ± 3% of nominal ± 3% of nominal Sine wave Output Connections Hardwired (x1 40A PDU shipped with the UPS, p/n: 252663-B21; (32) IEC320-C13 & (4) IEC320-C19 outlets; 0U/1U). Output Protection (Circuit breakers) Voltage Range Frequency Input connection Online Efficiency >83% Surge Suppression Input Current Inrush Current Type Backup Time Typical Recharge Time The UPS does not have any output circuit breakers (on the input-end, the UPS will need a 100A circuit with over current protection). When a HP PDU is hardwired to the UPS, the output circuit breaker protection is provided by the PDU circuit breakers. 200-240 VAC 50/60 Hz ± 5Hz (auto sensing) Hardwired, single phase High energy 6500A peak; 88A maximum (100A circuit breaker is recommended upstream from UPS) 100A peak maximum Each module contains maintenance-free, sealed valve regulated lead-acid (VRLA) batteries with an 8-year min. float service. Each Battery Module consists of four 12v Lead Acid batteries. See Backup Times Chart Extended Runtime Module Supports up to two ERMs (PN 217800-B21) Communications Type Backup Time Recharge Time Serial Ports Management Software Included Control Panel Front Panel Button Controls LED Indicators Audible Alarms < 3 hours to 80% usable capacity; < 48 hours for complete recharge Two battery modules in a 4U chassis; (4) 12V 42AH batteries; (2) batteries on (2) trays. Extends runtime 15 min. at 80% load 80% in 8 hrs Two; DB9 RS232 connectors Yes LCD Front Panel display to configure and monitor UPS 2 line x 16 character LCD display; 7 languages (English, French, Spanish, German, Japanese, Italian, Dutch, Danish) Six-button control Environmental and Safety Operating Temperature 50 to 104 F (10 to 40 C) Five modes of operation; standby, operate, bypass, battery, and redundant. Yes Transit Temperature -13 to 131 F (-25 to 55 C) Storage Temperature 32 to 77 F (0 to 25 C) Operating Humidity Storage Humidity 5% to 95% Operating Altitude Transit Altitude Storage Altitude 5% to 95%; non-condensing Up to 10,000 ft (3048m) (0 to 4000 ft de-rated linearly to 80% at 10000 ft) 49,212 ft (15,000 m) above sea level 0 to 30,000 ft (9,144 m) above sea level DA - 11395 Worldwide Version 10 September 9, 2005 Page 10
Technical Specifications Availability Conformance Service and Warranty Audible Noise (dba) Online Thermal Dissipation (BTU/hr) Generator Compatible Mean Time Between Failure (MTBF) Bypass (during hot- swapping modules) Typically 60 dba 8,990 BTU/hr Yes 104,389.4 hours Yes, both automatic and manual bypass available Safety Markings FCS, UL, CSA, VDE, NEMKO, FIMKO, DEMKO, SEMKO, NOM, EN 60950 & IEC61000-4-X Safety Certifications UL1778; CSA22.2 No.107.1, No.107.2, No.950; CB Bulletin No.86AI; EN50091-1; EN60950; EMKO-TSE207/95; NOM-019-SCFI-1993 EMC Markings FCC; CISPR; VCCI; CE; IEC61000-4-X (Class A 210m) Emissions FCC CFR 47, Part 15 Class A, EN50091-2 Immunity IEC 801-2; IEC 801-3; IEC 801-4 Surge Suppression High energy 6500A peak; Conforms to IEEE 587B and ANSI C62.41 REPO Port Standard Warranty Installation and Start-up Services; Optional HP Care Pack Service Yes; Meets NEC code 645-11 intent and UL requirements Three-year limited warranty. For more details please refer to the Services and Warranty section above. Yes, FM-BPINS-IN (US) and FP-UPSXR-IN (WW). For more information refer services section above. Estimated Backup Times Chart (Minutes) Load (Percent*) With Standard Battery With 1 ERM With 2 ERMs 20 43 69 101 50 14 28 41 80 7 15 24 100 5 11 18 * Percent of 12000VA or 12000W of load NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions. Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. DA - 11395 Worldwide Version 10 September 9, 2005 Page 11