NI PXI Contents GETTING STARTED GUIDE. 8 GHz RF Amplifier

Similar documents
NI PXIe Contents GETTING STARTED GUIDE. RF Preselector Module

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

24-Channel, ±24 V Precision PXI Source Measure Unit

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral

12-Channel, ±24 V Precision PXI Source Measure Unit

To access NI 5622 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

NI PXIe-5160/5162. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10-Bit Oscilloscope

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

Electromagnetic Compatibility Guidelines

NI PXI-5650/5651/5652

NI PXIe-4080/4081/4082

To access NI 5105 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

NI USB Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10 MHz to 18 GHz RF Power Meter

To access NI 5114 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

PXI/PCI Contents GETTING STARTED GUIDE. 2 GS/s Oscilloscope

NI PXI/PXIe/PCI Contents GETTING STARTED GUIDE. 14-Bit, 100 MS/s PXI Oscilloscope

To access NI 5671 documentation, navigate to Start»All Programs»National Instruments» NI-RFSG»Documentation.

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product.

PXIe Contents GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

PXIe Contents. Verifying the System Requirements GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

NI PXIe-6544/6545/6547/6548

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

Single-Channel Precision System Source Measure Unit (SMU)

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

NI PXIe Contents GETTING STARTED GUIDE. 6 GHz T/R Two-Port Vector Network Analyzer

NI PXIe-6555/6556. Contents GETTING STARTED GUIDE. 200 MHz Digital Waveform Generator/Analyzer with PPMU

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

Electromagnetic Compatibility Guidelines

Contents. Software. CALIBRATION PROCEDURE NI Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module

6 GHz Reconfigurable RF Vector Signal Transceiver with 1 GHz Bandwidth

±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module

NI R Series. Contents. Software CALIBRATION PROCEDURE

NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

USRP Contents. Verifying the System Requirements GETTING STARTED GUIDE. USRP Software Defined Radio Stand-Alone Device

100 MHz, 250 MS/s, 14-Bit PXI Express Oscilloscope. This document explains how to install and start using the PXIe-5172.

6 GHz Reconfigurable RF Vector Signal Transceiver with 200 MHz Bandwidth

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

Contents. CALIBRATION PROCEDURE NI PXIe-5624R 2 GS/s, 12-Bit IF Digitizer

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

Bracket and Mounting Dimensions

CALIBRATION PROCEDURE NI channel, ±2- ma/±10 V, 24-bit Analog Input Module. ni.com/manuals

INSTALLATION GUIDE AND SPECIFICATIONS PXIe-4844

10 MHz to 6 GHz, x86 Processor, GPS-Disciplined OCXO, USRP Software Defined Radio Stand-Alone Device

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

Foundation Fieldbus Hardware and NI-FBUS Software

Figure 1. NI-7935R. Related Information For information about the device specifications, refer to the NI-7935R Specifications at ni.com/manuals.

GETTING STARTED GUIDE NI S/s/channel, 4-Channel C Series Universal Analog Input Module

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

CALIBRATION PROCEDURE NI PXIe Channel, Isolated Voltage/Current Analog Output Module

NI Safety Guidelines. Safety Guidelines for Hazardous Locations GETTING STARTED GUIDE. Ethernet Expansion Chassis for C Series Modules

NI PXI Contents GETTING STARTED GUIDE

GETTING STARTED GUIDE NI Ch 24 V Sinking DI, 8-Ch 24 V Sourcing DO SIL3 Capable

This document includes instructions for installing and configuring your PXIe-8821 PXI Express controller module.

Embedded Real-Time Controller with Reconfigurable FPGA for C Series Modules. This document describes how to begin using the NI crio-9064.

This document includes instructions for installing and configuring your PXIe-8861 PXI Express controller module.

CALIBRATION PROCEDURE CAL Contents. Software

NI SMD-7610 Stepper Drives and NI 9512 C Series Modules

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals

NI ELVIS RIO Control Module

SCXI -1104/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

USER GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4340 and TB Ch, 24-bit, 25.6 ks/s Simultaneous AC LVDT Input Module

GETTING STARTED GUIDE

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals

NI WSN-9791 Ethernet Gateway

Contents. Software CALIBRATION PROCEDURE NI TC-4353

NI crio-9101/9102/9103/9104

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

Electromagnetic Compatibility Guidelines

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

Getting Results with the NI 5752R

Contents. Software Requirements. CALIBRATION PROCEDURE NI PXIe-4357

Getting Results with the NI PXI-6585R

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

GETTING STARTED NI 9501 C Series Stepper Drive Modules and NI SoftMotion Module

Contents. Software Requirements CALIBRATION PROCEDURE NI TB-4353

GETTING STARTED NI SMD-7611/7612 Stepper Drives and NI 9512 C Series Modules

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4322 and TB Channel, Isolated Voltage/Current Analog Output Module

NI CMS-9068 and NI MMS-9068

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

Electrical. SPECIFICATIONS SH Cable

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

Getting Started with R Series Multifunction RIO

This document describes the features, functions, and operation of the NI PXIe-8383mc PXImc adapter module.

Getting Started with R Series Intelligent DAQ

Embedded Direct Injector Control and Measurement (DCM) Device with Real-Time Processor and Reconfigurable FPGA

Transcription:

GETTING STARTED GUIDE NI PXI-5691 8 GHz RF Amplifier Note Before you begin, install and configure your chassis and controller. This document explains how to install, configure, and test the NI PXI-5691 (NI 5691). The NI 5691 is a two-channel programmable RF amplifier that provides fixed gain and programmable gain in a single-slot PXI module. The NI 5691 signal conditioning device ships with the NI-5690 instrument driver, which you can use to program the device. To access NI 5691 documentation, navigate to Start»All Programs»National Instruments» NI-5690»Documentation. Contents Electromagnetic Compatibility Guidelines...2 Unpacking the Kit...2 Preparing the Environment... 3 Verifying the System Requirements... 3 Verifying the Kit Contents... 3 Other Equipment...4 Installing the Software... 4 Installing the NI 5691... 4 Connecting Signals... 6 Direct Connections to the NI 5691... 6 Torquing SMA Connections... 6 Hardware Front Panel Connectors and Indicators... 8 Configuring the NI 5691 in... 9 Programming the Device... 10 NI-5690 Instrument Driver Examples... 10 Making Your First Measurement... 11 Troubleshooting... 11 NI 5691 Does Not Appear in...11 Module Fails the Self-Test... 11 Why Is the ACCESS LED Off When the Chassis is On?...12 Device Is Too Hot... 12 Performance Issues Using an MXI Connection...12 Where to Go Next... 13 Worldwide Support and Services...13

Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Caution To ensure the specified EMC performance, the length of all I/O cables except for that connected to the GPS antenna input must be no longer than 3 m (10 ft). Unpacking the Kit Caution To prevent electrostatic discharge from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis. 1. Touch the antistatic package to a metal part of the computer chassis. 2. Remove the device from the package and inspect the device for loose components or any other sign of damage. Caution Never touch the exposed pins of connectors. Notify NI if the device appears damaged in any way. Do not install a damaged device. 3. Unpack any other items and documentation from the kit. Store the device in the antistatic package when the device is not in use. 2 ni.com NI PXI-5691 Getting Started Guide

Preparing the Environment Ensure that the environment you are using the NI 5691 in meets the following specifications.... Operating temperature 0 to 55 C... Operating humidity 10% to 90% RH, noncondensing... Pollution Degree 2... Maximum altitude 2,000 m Indoor use only. Note Refer to the device specifications on ni.com/manuals for complete specifications. Note Do not operate the device in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to National Instruments for repair. Verifying the System Requirements To use the NI-5690 instrument driver, your system must meet certain requirements. For more information about minimum system requirements, recommended system, and supported application development environments (ADEs), refer to the product readme, which is available on the driver software media or online at ni.com/updates. Verifying the Kit Contents Figure 1. NI 5691 Kit Contents 1 2 3 4 1. NI 5690 Module 2. SMA Cable 3. NI-5690 Driver Software Media 4. NI PXI-5691 Getting Started Guide (this document) NI PXI-5691 Getting Started Guide National Instruments 3

Other Equipment There are several required items not included in your device kit that you need to install or operate the NI 5691. Required Items A PXI chassis and chassis documentation. The NI PXI-1045 chassis is one available option for your device. For more information about compatible chassis options, refer to ni.com. A PXI embedded controller or MXI controller system that meets the system requirements specified in this guide and chassis documentation. Optional Items A 1 N m standard SMA torque wrench (NI part number 780487-01). Installing the Software You must be an Administrator to install NI software on your computer. 1. Install an ADE, such as LabVIEW or LabWindows /CVI. 2. Insert the driver software media into your computer. The installer should open automatically. If the installation window does not appear, navigate to the drive, double-click it, and double-click autorun.exe. 3. Follow the instructions in the installation prompts. Note Windows users may see access and security messages during installation. Accept the prompts to complete the installation. 4. When the installer completes, select Restart in the dialog box that prompts you to restart, shut down, or restart later. Installing the NI 5691 Caution To prevent damage to the device caused by ESD or contamination, handle the device using the edges or the metal bracket. Note Ground yourself with a resistor-isolated wrist strap before installing the module, before touching the center pin of any connector, and before removing or adjusting any connections to the module. 1. Ensure the AC power source is connected to the chassis before installing the modules. The AC power cord grounds the chassis and protects it from electrical damage while you install the modules. 2. Power off the chassis. 4 ni.com NI PXI-5691 Getting Started Guide

3. Inspect the slot pins on the chassis backplane for any bends or damage prior to installation. Do not install a module if the backplane is damaged. 4. Remove the black plastic connectors from all the captive screws on the module front panel. 5. Identify a supported slot in the chassis. The following figure shows the symbols that indicate the slot types. Figure 2. Chassis Compatibility Symbols NI PXIe-1062Q 1 2 3 4 5 1. PXI Express System Controller Slot 2. PXI Peripheral Slot 3. PXI Express Hybrid Peripheral Slot 4. PXI Express System Timing Slot 5. PXI Express Peripheral Slot NI 5691 modules can be placed only in PXI peripheral slots. 6. Touch any metal part of the chassis to discharge static electricity. 7. Ensure that the ejector handle is in the unlatched (downward) position. 8. Place the module edges into the module guides at the top and bottom of the chassis. Slide the device into the slot until it is fully inserted. Figure 3. Module Installation 1 NI PXIe-1075 2 3 1. Chassis 2. Hardware Module 3. Ejector Handle in Down (Unlatched Position) 9. Latch the module in place by pulling up on the ejector handle. 10. Secure the device front panel to the chassis using the front-panel mounting screws. NI PXI-5691 Getting Started Guide National Instruments 5

11. Cover all empty slots using filler panels or slot blockers to maximize cooling air flow. 12. Power on the chassis. Connecting Signals Direct Connections to the NI 5691 The NI 5691 is a precision RF instrument that is sensitive to ESD and transients. Ensure you are making proper direct connections to the NI 5691 to avoid damaging the device. Caution Apply external signals only while the NI 5691 is powered on. Applying external signals while the device is powered off may cause damage. To prevent possible damage to the device, use caution when connecting signal sources and RF antennas directly to the IN connectors of the NI 5691. Operators, technicians, and all other users should ensure they are properly grounded when manipulating cables or antennas connected to the NI 5691 IN connectors. If you are using noninsulated devices, such as a noninsulated RF antenna, ensure the devices are maintained in a static-free environment. If you are using an active device, such as a preamplifier or switch routed to the NI 5691 IN connectors, ensure that there are no signal transients greater than the RF and DC specifications for the device that are being generated and sourced to the NI 5691 IN connectors. Torquing SMA Connections Note A coaxial cable with open ends can function as a capacitor. Before connecting any open-ended cable to the NI 5691, momentarily short the center and outer connectors of the cable together. Note For best results when connecting signals to the NI 5691 front panel SMA connectors, use shielded low-loss coaxial cables. Torque all connections to 100 N cm using a standard SMA torque wrench. Apply force until the wrench clicks. 6 ni.com NI PXI-5691 Getting Started Guide

Figure 4. Using the Standard SMA Torque Wrench RF Amplifier ACCESS ACTIVE 50 MHz - 8 GHz IN +30 dbm 1 OUT +25 dbm Reverse Power +20 dbm CH 0 IN +30 dbm OUT +25 dbm Reverse Power +20 dbm CH 1 2 1. 100 N cm SMA Torque Wrench 2. Apply Force Here Until Wrench Clicks NI PXI-5691 Getting Started Guide National Instruments 7

Hardware Front Panel Connectors and Indicators ACCESS ACTIVE 50 MHz - 8 GHz IN +30 dbm CH 0 OUT +25 dbm Reverse Power +20 dbm IN +30 dbm CH 1 OUT +25 dbm Reverse Power +20 dbm Table 1. NI 5691 Front Panel Connectors Connector Access Function CH 0 IN Input CH 0 IN and CH 0 OUT each function as a fixed-gain amplifier. CH 0 OUT Output These channels offer a low noise figure and a flat frequency response. CH 0 IN and CH 0 OUT are AC-coupled. 8 ni.com NI PXI-5691 Getting Started Guide

Table 1. NI 5691 Front Panel Connectors (Continued) Connector Access Function CH 1 IN Input CH 1 IN and CH 1 OUT each function as a programmable amplifier CH 1 OUT Output with switchable main and direct paths. The main path offers fixed gain amplification in series with a step attenuator that is adjustable in 0.5 db nominal steps 1. The direct path bypasses the programmable circuitry and routes the signal directly to the output. The direct path passes DC level to output, whereas the main path is AC-coupled. Table 2. NI 5691 Front Panel LED Indicators LED Indications ACCESS Indicates the basic hardware status of the NI RF signal conditioning module. OFF The module is not yet functional, or has detected a problem with a PXI power rail. AMBER The module is being accessed. GREEN The module is ready to be programmed. ACTIVE Indicates the operational status of the NI RF signal conditioning module. OFF The module is in an uninitialized state. GREEN The module is in a ready state or in use. Related Information Refer to the Devices book in the NI RF Signal Conditioning Devices Help for more information about using channels and paths. Configuring the NI 5691 in Use Measurement & Automation Explorer () to configure your National Instruments hardware. informs other programs about which devices reside in the system and how they are configured. is automatically installed with the NI-5690 instrument driver. 1. Launch Measurement & Automation Explorer (). should automatically detect the device you installed. 1 Refer to the NI PXI-5691 Specifications for detailed gain specifications. NI PXI-5691 Getting Started Guide National Instruments 9

2. In the Configuration pane, double-click Devices and Interfaces to see the list of installed devices. Installed devices appear under the name of their associated chassis. Note If you are using the NI 5691 with the LabVIEW Real-Time Module, expand Remote Systems. Find your target IP address or name, expand it, and then expand Devices and Interfaces. 3. Expand your Chassis tree item. lists all devices installed in the chassis. Your default device names may vary. Note If you do not see your hardware listed, press <F5> to refresh the list of installed devices. If the device is still not listed, power off the system, ensure the device is correctly installed, and restart. 4. Record the device identifier assigns to the hardware. Use this identifier when programming the NI 5691. 5. The self-test performs a basic verification of hardware resources. To self-test a module in, right click the module and select Self-Test. Programming the Device You can use the NI-5690 instrument driver to program the NI 5691 in the supported ADE of your choice. NI-5690 Instrument Driver Examples Examples demonstrate the functionality of the device and serve as programming models and building blocks for your own applications. The NI Example Finder is a utility available for some ADEs that organizes examples into categories and allows you to easily browse and search installed examples. You can see descriptions and compatible hardware models for each example, or see all the examples compatible with one particular hardware model. To locate examples, refer to the following table. Application Development Environment (ADE) Table 3. Locating NI-5690 Examples Locating Examples LabVIEW or LabWindows/CVI LabVIEW, LabWindows/ CVI, or C Locate examples with the NI Example Finder. Within LabVIEW or LabWindows/CVI, select Help»Find Examples, and navigate to Hardware Input and Output» Modular Instruments»NI-5690 (RF Preamplifier). Locate examples 2 from the Start menu by navigating to Start»All Programs»National Instruments»NI-5690» Examples. 2 You can modify an NI-5690 C example to create an application with Microsoft Visual C/C++, and all required include and library files are automatically added to the project. 10 ni.com NI PXI-5691 Getting Started Guide

Making Your First Measurement To begin making measurements with the NI 5691, complete the following steps: 1. Launch your ADE. 2. Navigate to Start»All Programs»National Instruments»NI-5690»Examples and open one of the examples. 3. Select your device from the resource name control. 4. Run the example. Troubleshooting If an issue persists after you complete a troubleshooting procedure, contact NI technical support or visit ni.com/support. NI 5691 Does Not Appear in 1. In the Configuration pane, click Devices and Interfaces. 2. Expand the Chassis tree to see the list of installed devices, and press <F5> to refresh the list. 3. If the module is still not listed, power off the system, ensure that all hardware is correctly installed, and restart the system. 4. Navigate to the Device Manager. Option Windows 8 Windows 7 Description Right-click the Start screen, and select All apps»control Panel» Hardware and Sound»Device Manager. Select Start»Control Panel»Device Manager. Windows Vista Select Start»Control Panel»System and Maintenance»Device Manager. Windows XP Select Start»Control Panel»System»Hardware»Device Manager. 5. If you are using a PXI controller, verify that a National Instruments entry appears in the system device list. Reinstall the NI-5690 instrument driver and the device if error conditions appear in the list. If you are using a MXI controller, right-click PCI-to-PCI Bridge, and select Properties from the shortcut menu to verify that the bridge is enabled. Module Fails the Self-Test 1. Restart the system. 2. Launch, and perform the self-test again. 3. Power off the PXI chassis. 4. Reinstall the failed module in a different PXI slot. 5. Power on the PXI chassis. NI PXI-5691 Getting Started Guide National Instruments 11

6. Perform the self-test again. Why Is the ACCESS LED Off When the Chassis is On? The LEDs may not illuminate until the device has been configured in. Before proceeding, verify that the NI 5691 appears in. If the ACCESS LED fails to illuminate after you power on the chassis, a problem may exist with the chassis power rails, a hardware module, or the LED. Caution Apply external signals only while the NI 5691 is powered on. Applying external signals while the device is powered off may cause damage. 1. Disconnect any signals from the module front panels. 2. Power off the chassis. 3. Remove the module from the chassis and inspect it for damage. Do not reinstall a damaged device. 4. Install the module in a different chassis slot from which you removed it. 5. Power on the chassis. 6. Verify that the device appears in. 7. Reset the device in and perform a self-test. Device Is Too Hot NI 5691 devices have onboard sensors that monitor the device operating temperature. When running at room temperature (25 C), the sensor typically reads a temperature of 30 C ± 5 C, depending on the module and what other devices are installed in the chassis. Access the onboard sensor using the ni5690 Get Temperature VI or the ni5690_gettemperature function. Performance Issues Using an MXI Connection When you use an MXI-3 connection to control the PXI chassis, you must run the MXI Optimization Application prior to using the NI 5691. By default, this application runs automatically when Windows starts. Using an MXI connection without running this application may result in a time exceeded or internal software error, an initialization timeout, or a performance issue when using the NI 5691. 1. Ensure the MXI software is installed. If the MXI software is not installed, refer to the setup instructions included with the MXI kit. After installation, you may be required to restart your computer before using the MXI application. 2. For MXI-3 optimization, select Start»All Programs»National Instruments MXI-3» MXI-3 Optimization. MXI-4 optimization is performed automatically by the MXI-4 hardware. If you continue to have initialization or performance issues, refer to the MXI documentation included in your MXI kit, contact NI technical support, or visit ni.com/support. 12 ni.com NI PXI-5691 Getting Started Guide

NI PXI-5690 RF Preamplifier Where to Go Next Refer to the following figure for information about other product tasks and associated resources for those tasks. Located in the hardware kit Located online at ni.com/manuals Located using the NI Example Finder EXPLORE LEARN CREATE the application development environment (ADE) for your application. about hardware features or review device specifications. custom applications within an application programming interface (API). Learn LabVIEW Basics Getting Started with LabWindows/CVI NI PXI-5691 Specifications* NI RF Signal Conditioning Devices Help* NI-5690 Instrument Driver NI-5690 Examples* NI RF Signal Conditioning Devices Help* DISCOVER more about your products through ni.com. Support ni.com/support RF Solutions ni.com/rf Services ni.com/services Updates ni.com/updates *This item is also installed with the driver software. Tip The NI RF Signal Conditioning Devices Help is an HTML version of a traditional user manual that includes detailed information about RF fundamentals, device features, and programming with the NI-5690 instrument driver. Worldwide Support and Services The National Instruments website is your complete resource for technical support. At ni.com/ support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. NI PXI-5691 Getting Started Guide National Instruments 13

Visit ni.com/register to register your National Instruments product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help» Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/ patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2014 National Instruments. All rights reserved. 376267A-01 Jul14