Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Similar documents
Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Functional data Factory settings Variable Setting Torque Inhibiting torque

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Products no longer available

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Products no longer available

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data sheet. Technical data

Power consumption In operation At rest For wire sizing

Technical data sheets

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overview of types. Technical data

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

s Spring return C / max C

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

Brief description. Type overview

Brief description. Type overview

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes. Product features

Technical data. PRCA-BAC-S2-T en-gb subject to changes 1

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

VAV system solution for non-pressure dependent applications in enclosed spaces

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical Actuators

Electrical Actuators

NKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

Electrical Actuators

ASI Systems ML5740A Series

ASI Systems ML5720A Series

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Power consumption motor (motion) 2,5 W Power consumption standby (end position) 1,0 W. Position feedback -

Technical data sheet

Electrical actuator AME 855

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

VA-7700 Series. Electric Valve Actuators. Product Bulletin

ML7421A,B Electric Linear Valve Actuators

Electromotoric actuators

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

Electromotive actuators for combi valves

Actuators AMV 655, 658 and 659 can be controlled by electronic controllers with 3-point output.

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

A CLOSER LOOK. Electronic Fail-Safe Series Direct Coupled Actuators. The Belimo Difference. Brushless DC Motor for Added Accuracy and Controllability

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Belimo ZoneTight TM QCV 2-way characterised control valves and 3-way change-over ball valves. Table of Contents. Notes for project planning

AVM 321, 322: Valve actuator

Operating instructions. Standstill monitor A / / 2011

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

Rotary version, three-position control

N20010-SER. NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

Rotary actuators for ball valves

24V, Motorized Actuators

Actuators for three point control AMV 655 without safety function AMV 658 SU, AMV 658 SD with safety function (spring up/down)

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

VAV compact controller GDB181.1E/3 GLB181.1E/3

Actuators AME 655, 658 and 659 can be controlled by electronic controllers with modulating or 3-point control output.

Operating instructions. Switching amplifier DN0210 DN / / 2015

N20010, N NON-SPRING RETURN DAMPER ACTUATOR 20/34 Nm (177/300 lb-in) FOR MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

Room Temperature Controller

Room Temperature Controllers

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

ZN230-24MP-1 MP-BUS

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Room Temperature Controller

Air damper actuators

Modulating controlled actuator AME 11

Actuators for modulating control AME 13SU, AME 23SU - safety function (spring up)

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Electrical actuators

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Belimo Gateway MP to Modbus RTU - UK24MOD

Installation VAV-Compact Retrofit Set

QUINT-BUFFER/24DC/24DC/40

252F 5WG FB_1 DELTA

Actuators for modulating & 3-point control

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Electromotoric actuators

Transcription:

echnical data sheet NVK4A-SR-PC Modulating globe valve actuator for -way and 3-way globe valves Actuating force 000 N Nominal voltage AC/DC 4 V Control: modulating DC (0) V...0 V Nominal stroke 0 mm Design life SuperCaps 5 years echnical data Electrical data Nominal voltage AC/DC 4 V Nominal voltage frequency 50/60 Hz Nominal voltage range AC 9...8.8 V / DC.6...8.8 V Power consumption in operation.5 W Power consumption in rest position.5 W Power consumption for wire sizing 6 VA Connection supply / control erminals 4 mm² and cable m, 4 x 0.75 mm² Parallel operation Yes Functional data Actuating force 000 N Positioning signal Y DC 0...0 V Positioning signal Y note Input impedance 00 kω Operating range Y DC...0 V Position feedback U DC...0 V Position feedback U note max. 0.5 ma Setting emergency setting position Actuator spindle 0...00%, adjustable (POP rotary knob) Position accuracy 5% absolute Manual override Gear disengagement with push-button Nominal stroke 0 mm Actuating time 50 s / 0 mm Actuating time emergency control 35 s / 0 mm function Sound power level motor max. 55 db (A) Sound power level emergency setting 60 db (A) position max. Position indication Mechanical 5 0 mm stroke Safety Protection class IEC/EN III Safety extra-low voltage Degree of protection IEC/EN IP54 EMC CE in accordance with 004/08/EC Certification IEC/EN Certified to: IEC/EN 60730- and IEC/EN 60730--4 Mode of operation ype.aa Rated impulse voltage supply / control 0.8 kv Control pollution degree 3 Ambient temperature 0 C... 50 C Non-operating temperature -40 C... 80 C Ambient humidity 95% r.h., non-condensing Maintenance Maintenance-free Weight Weight approx..60 kg Safety notes! his actuator has been designed for application in stationary heating, ventilation and air-conditioning systems and is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied with during installation. www.belimo.com NVK4A-SR-PC en-gb 0-- Subject to modification

NVK4A-SR-PC Globe valve actuator, modulating, AC/DC 4 V, 000 N Safety notes! he switch for changing the direction of motion/the closing point may be adjusted only by authorised personnel. he direction of stroke is critical, particularly in connection with frost protection circuits. he device may only be opened at the manufacturer's site. It does not contain any parts that can be replaced or repaired by the user. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. Product features Principle of operation Pre-charging time (start up) he actuator is connected with a standard modulating signal of DC 0... 0V and travels to the position defined by the positioning signal at the same time the integrated capacitors are being charged.. Interrupting the supply voltage causes the valve to be moved to the selected emergency setting position (POP) by means of stored electrical energy. he capacitor actuators require a pre-charging time. his time is used for charging the capacitors up to a usable voltage level. his ensures that, in the event of an electricity interruption, the actuator can move at any time from its current position into the preset emergency setting position (POP). he duration of the pre-charging time depends mainly on how long the power was interrupted. ypical pre-charging time 30 30 5 5 0 0 [s] 5 5 0 0 5 5 0 0 0 4 6 8 0 [d ] [d] = Electricity interruption in days [s] = Pre-charging time in seconds PF[s] = Bridging time Delivery condition (capacitors) Direct mounting Manual override High functional reliability Combination valve/actuator Position indication [ d] 0 7 0 [s] 6 9 6 0 he actuator is completely discharged after delivery from the factory, which is why the actuator requires approximately 0 s pre-charging time before initial commissioning in order to bring the capacitors up to the required voltage level. Simple direct mounting on the globe valve by means of form-fit hollow clamping jaws. he actuator can be rotated by 360 on the valve neck. Manual override with push-button possible - temporary. he gear is disengaged and the actuator decoupled for as long as the button is pressed. he stroke can be adjusted by using a hexagon socket screw key (4 mm), which is inserted into the top of the actuator. he stroke spindle extends when the key is rotated clockwise. he actuator is overload protected, requires no limit switches and automatically stops when the end stop is reached. Refer to the valve documentation for suitable valves, their permitted medium temperatures and closing pressures. he stroke is indicated mechanically on the bracket with tabs. he stroke range adjusts itself automatically during operation. NVK4A-SR-PC en-gb 0-- Subject to modification www.belimo.com

NVK4A-SR-PC Globe valve actuator, modulating, AC/DC 4 V, 000 N Product features Home position Direction of stroke switch Adaption of stroke range Rotary knob emergency setting position Setting ex-works: Actuator spindle is retracted. When valve-actuator combinations are shipped, the direction of motion is set in accordance with the closing point of the valve. When actuated, the direction of stroke switch changes the running direction in normal operation. he direction of stroke switch has no influence on the emergency setting position (POP) which has been set he first time the supply voltage is switched on, i.e. at the time of commissioning, the actuator carries out a stroke adaption, which is when the operating range and position feedback adjust themselves to the mechanical stroke. Manual triggering of the adaption can be carried out by pressing the "Adaption" button. he actuator then moves into the position defined by the positioning signal. he "Emergency setting position" rotary knob can be used to adjust the desired emergency setting position (POP) from 0% to 00% in 0% increments. he rotary knob is in reference to the adapted or programmed height of stroke. In the event of an electricity interruption, the actuator will move into the selected emergency setting position, taking into account the bridging time (PF) of s which was set ex-works. Accessories Description ype Electrical accessories Auxiliary switch add-on, x SPD SA-H Electrical installation! Notes Connection via safety isolating transformer. Parallel connection of other actuators possible. Direction of stroke switch factory setting: Actuator spindle retracted. Wiring diagrams AC/DC 4V, modulating Y U DC (0)... 0 V DC (0)... 0 V 3 5 Cable colours: = black = red 3 = white 5 = orange www.belimo.com NVK4A-SR-PC en-gb 0-- Subject to modification 3

NVK4A-SR-PC Globe valve actuator, modulating, AC/DC 4 V, 000 N Indicators and operating controls () Direction of stroke switch Switching: Direction of stroke changes () Cover, POP button (3) POP button (4) Scale for manual adjustment (6) No function 0 (7) Gear disengagement button, temporary Press button: Gear disengages, motor stops, manual override possible Release button: Gear engages, standard mode (8) LED display, yellow 7 POP 4 0.5 3POP 8 9 Status Power Adaption (9) Push-button and LED display green Press button: riggers stroke adaption, followed by standard mode (0) Manual override Clockwise: Actuator spindle extends Counterclockwise: Actuator spindle retracts LED displays (8, yellow) and (9, green) yellow: Off; green: Illuminated; In operation OK yellow: Off; green: Blinking; POP function active yellow: Illuminated; green: Off; Pre-charging time SuperCap / Fault SuperCap yellow: Off; green: Off; Not in operation yellow: Illuminated; green: Illuminated; Adaption procedure active 6 4 NVK4A-SR-PC en-gb 0-- Subject to modification www.belimo.com

NVK4A-SR-PC Globe valve actuator, modulating, AC/DC 4 V, 000 N Indicators and operating controls 0.5 0.5 0.5 POP 0.5 POP % 0...00 Status Power Adaption Dimensions [mm] Dimensional drawings 45 44 98 77 67 www.belimo.com NVK4A-SR-PC en-gb 0-- Subject to modification 5

NVK4A-SR-PC Globe valve actuator, modulating, AC/DC 4 V, 000 N Further documentation Data sheets for globe valves Installation instructions for actuators and/or globe valves, respectively Notes for project planning, -way and 3-way globe valves Overview "Valve-actuator combinations" 6 NVK4A-SR-PC en-gb 0-- Subject to modification www.belimo.com

LVK..A-.. / NVK..A-.. / SVK..A-.. 7400-0000.B A AB A AB B A AB 3 4mm 5Nm 4mm 4 M www.belimo.com LVK..A-../NVK..A-../SVK..A-.. 03-06-4 /

LVK..A-.. / NVK..A-.. / SVK..A-.. AC 4 V AC 30 V! N L a b a b 3 4 3 4 LVK(C)4A-3 NVK(C)4A-3 SVK(C)4A-3 LVK30A-3 NVK30A-3 SVK30A-3 3 a 4 b AC 4 V / DC 4 V Y U DC (0) 0.5... 0 V DC (0) 0.5... 0 V Y U DC (0)... 0 V DC (0)... 0 V 3 5 3 5 LVK(C)4A-SZ NVK(C)4A-SZ SVK(C)4A-SZ LVK(C)4A-MF NVK(C)4A-MF SVK(C)4A-MF LVK(C)4A-SR NVK(C)4A-SR SVK(C)4A-SR Y U DC (0) 0.5... 0 V MP 3 5 LVK(C)4A-MP NVK(C)4A-MP SVK(C)4A-MP 3 5 6 7 MF LON LON LVK4ALON NVK4ALON SVK4ALON / LVK..A-../NVK..A-../SVK..A-.. 03-06-4 www.belimo.com