SAFETY RELAY AD SR0 INSTALLATION USE AND MAINTENANCE

Similar documents
SAFETY RELAY AD SR0 INSTALLATION USE AND MAINTENANCE

AUS X CONTROL UNIT... 4 OPERATING MODES DESCRIPTION AUTOMATIC... 4 MANUAL... 5 CONNECTION OF EXTERNAL CONTACTORS K1 and K2...

HM1 Operator panel Installation and use

Dichiarazione CE di conformità EC declaration of conformity

Dichiarazione CE di conformità EC declaration of conformity

PS3 CONTROL UNIT. for 4-wire ribbon switches, edges and mats. Instruction use and maintenance READ BEFORE ANY INSTALLATION

M1 module TERMINAL SIGNAL TYPE DESCRIPTION OPERATION

SAFETY INTERFACES SAFETY INTERFACES AND RELAYS

Installation and operation manual EPIC

SEQUENCER FOR DEDUSTING PLANTS

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

MAXIMA+ Series Rotary Level Indicator

MAXIMA + Series ROTARY LEVEL CONTROL

This Errata Sheet contains corrections or changes made after the publication of this manual.

SAFETY INFORMATION. Precautions to be observed for the choice and installation of the device

PHOTOELECTRIC BARRIER ULISSE UNC INSTALLATION, USE AND MAINTENANCE

USER MANUAL. WBI412F41 AC current transducer

USER MANUAL. WBV412U01 AC voltage transducer

Number of input channels

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

RELAY MODULE A/B INSTALLATION/USE INSTRUCTIONS

Electronic Temperature Controller. Instruction Manual Version

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

USER MANUAL. WBI414F21 AC current transducer

Operating Instructions Differential Pressure Transducer PS27

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

2 Channel DALI Power Supply and Interface Installation Instructions. This page was intentionally left blank

Dichiarazione CE di conformità EC declaration of conformity

OPERATING INSTRUCTIONS

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

MC 11 EB-2 Power supply cabinet with external bus, AC version

HI ma Simulator

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

HI ma Simulator

Operating Instructions

MODULAR SAFETY INTEGRATED CONTROLLER

Kramer Electronics, Ltd. USER MANUAL. Models: RC-2C, Wall Plate / RS-232 / IR Controller RC-2, Wall Plate / RS-232 Controller

Model DPDT Switch Module

onlinecomponents.com

7032 Digital-Analog Multimeter

I/O SIGNAL CONDITIONER

LCI User Manual mantracourt.com

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller

MCR 808LX RELAY MANAGEMENT MODULE

COGNEX. Checker SensorView. Quick Reference Guide

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

Operating instructions. Switching amplifier DN0210 DN / / 2015

Redundancy unit CP-A RU

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

EC2 EXPANSION CONTROLLER MODULE OPERATING INSTRUCTIONS

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

AUTOMATIC SHORE GENERATOR (INVERTER)- SWITCH OVER UNIT FOR 2 SOURCES LAU 216 (F)

Installation manual Digital Energy USB / RS232 / Relay Interface Card for use with GE Digital Energy VH Series UPS VA

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

ILT2 motorized screens INTERFACE

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Model SPDT Switch Module

Language of the manual

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Manual. Panelmeter EX20xx, EX30xx

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

SMVector Additional I/O Module Installation and Operation Manual

Operating Instructions

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Installation Manual BAK02

Introduction. 1. RF Module

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

2-Way Wireless I/O Expander Installation Guide

Albatros 2 Grid supervision module / PSU User manual. AVS76.39x/309. Infrastructure & Cities. Edition 2.1

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

MPF-1, Mains Power Filter User Manual

CA-A480-A Elevator Controller. Reference & Installation Manual

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

RТTH DUAL ROOM SWITCH

Tina 1A Blanking plug

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

MDM 011-Z1 Regen Resistor

EM-F-7G Safety Extension Module

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

ACCESSORIES FOR SAFETY DEVICES

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

Transcription:

SAFETY RELAY AD SR0 INSTALLATION USE AND MAINTENANCE This symbol indicates an important personal safety warning. Failure to comply with the warning may result in very high risk for exposed personnel. INTRODUCTION The AD SR0 is an accessory device for the interconnection of a photoelectric light curtain in a safety circuit. See details below about light curtain models, wiring, etc. When deciding on the safety category to be adopted, carefully consider the risks analysis of the machine. The module has been designed in particular for use with the REER light curtains of the Admiral AX (category 4), Vision VX and Vision VXL/MXL (category 2) series. Consult REER before using the interface with other light curtain models or safety devices. For safe use of the device, it is essential to read and understand the contents of this handbook. Failure to comply with the prescriptions indicated in this notice may result in very high risks for the operating personnel of the protected machine. INSTALLATION AND ELECTRICAL CONNECTIONS Install the AD SR0 safety relay in an environment with a protection rating of at least IP54. The AD SR0 safety relay must be supplied with a 24Vdc ±20% power supply. The external power supply must comply with the standard EN 60204-1. ELECTRICAL CONNECTIONS The safety relay is equipped with three terminal boards for the connections to the light curtain and to the machine. CJ3 CJ2 CJ1 Figure 1 8540554 19 Gennaio 2010 Rev.9 7

CJ1 PIN NAME DESCRIPTION 1 FB Internal relays feedback 2 24VDC 24Vdc Power Supply 3 0VDC 0Vdc Power Supply 4 IN2 Light curtain static output 5 IN1 Light curtain static output CJ2 CJ3 PIN NOME PIN NOME 6 N.O. contact 9 N.O. contact 7 N.O. contact 10 N.O. contact 8 N.C. contact 11 N.C. contact Example of connection of the AD SR0 module with JANUS safety light curtain * : USE INTERFACE SUPPRESSOR Figure 2 8 8540554 19 Gennaio 2010 Rev.9

Example of connection of the AD SR0 module with AX / VX / VXL safety light curtain in AUTOMATIC operatione mode Example of connection of the AD SR0 module with AX / VX / VXL safety light curtain in MANUAL operatione mode Connection of VXL Emitter (modification of the above schematics) * If the TEST function is not required by the application, connect pin 2 of the emitter to +24Vdc. 8540554 19 Gennaio 2010 Rev.9 9

Example of connection of the AD SR0 module with MXL safety light curtain in AUTOMATIC operatione mode Example of connection of the AD SR0 module with MXL safety light curtain in MANUAL operatione mode Further details regarding connections can be found on each curtain technical manual. 10 8540554 19 Gennaio 2010 Rev.9

Characteristics of the output circuit. For the output circuit, the safety relay uses two guided contact safety relays. These relays are rated by the manufacturer for voltage and current values above those indicated in the technical data; however, to assure correct insulation and to avoid damage or premature aging, protect each output line with a 3,15A slow-blow fuse and check that load characteristics comply with the indications given in the table below. Minimum switching voltage Minimum switching current Maximum switching voltage Maximum switching current 18 Vdc 20 ma 250Vac 2A Warnings regarding the connection cables. For light curtain/safety interface connections of more than 50m, cables with a cross-section of at least 1mm 2 must be used. It is good practice to separate the power supply of the safety relay from that of other electrical equipment (electrical motors, inverters, frequency variators) or other sources of disturbance. The path of the connection cables between the safety relay and the sensors, the connection referring to the feedback contact must be different from that of other power cables. TECHNICAL DATA Power supply Vdc 24 ± 20% Power requirement W 1,5 max Output Relay 2 N.O. + 1 N.C. contacts - 2A 250Vca Response time ms 20 max Connections Terminal block with protection against reversal of polarity Max. length of connections m 100 Operating temperature C 0-55 Enclosure protection rating IP 20 Terminal block protection rating IP 2X Fastening Fast attachment to rail according to EN 50022-35 Dimensions (h x w x d) mm 101x 35 x 120 Weight g 180 8540554 19 Gennaio 2010 Rev.9 11

WARRANTY REER warrants that each AD SR0 unit in new ex-factory condition, in conditions of normal use, is free of defects in the materials and of manufacturing defects for a period of 12 (twelve) months. In this period, REER undertakes to eliminate any faults in the product through repair or replacement of the faulty parts, completely free of charge as regards material and labor. However, REER reserves the right to replace the entire faulty appliance with another equivalent appliance or with the same characteristics instead of repairing this. Validity of this warranty is regulated by the following conditions: The user must inform REER of the fault within twelve months from the date of delivery of the product. The appliance and its components must be in the conditions in which they were delivered by REER. The serial numbers must be clearly legible. The fault or defect has not been caused directly or indirectly by: Improper use; Non-compliance with instructions for use; Carelessness, inexperience, incorrect maintenance; Repairs, modifications, adaptations not carried out by REER personnel, tampering, etc.; Accidents or impacts (also due to transportation or causes of force majeure); Other causes not to be ascribed to REER. Repairs will be carried out at the REER laboratories to which the material must be delivered or dispatched: transport risks and the risks of any damage or loss of the material during shipment are the responsibility of the user. All products and components replaced become the property of REER. REER does not recognize any other warranties or rights except for those specifically described above; therefore, no claims for damages may be submitted for expenses, interruption of business or other factors or circumstances in any way related to failure of the product or of one of its parts. Precise, complete compliance with all the rules, instructions and prohibitions indicated in this handbook is an essential requirement for correct functioning of the safety relay. REER s.p.a. therefore declines any responsibility for all and anything resulting from failure to comply, even partially, with such indications. Characteristics subject to change without notice. Total or partial reproduction is forbidden without the prior authorization of REER. 12 8540554 19 Gennaio 2010 Rev.9

Dichiarazione CE di conformità EC declaration of conformity REER SpA via Carcano 32 10153 Torino Italy Torino, 01/01/2010 dichiara che AD SR0 e AD SR0A sono Interfacce di Sicurezza realizzate in conformità alle seguenti Direttive Europee: declares that the AD SR0 and AD SR0A, Safety Interfaces comply with the following European Directives: 2006/42/CE "Direttiva Macchine" "Machine Directive" 2004/108/CE "Direttiva Compatibilità Elettromagnetica" "Electromagnetic Compatibility Directive" 2006/95/CE "Direttiva Bassa Tensione" "Low Voltage Directive" Carlo Pautasso Giancarlo Scaravelli Direttore Tecnico Technical Director Presidente della Società Company President 8540554 19 Gennaio 2010 Rev.9 13

14 8540554 19 Gennaio 2010 Rev.9

8540554 19 Gennaio 2010 Rev.9 15

REER S.p.A. 32 via Carcano 10153 Torino Italia Tel. +39/0112482215 r.a. Fax +39/011859867 Internet: www.reer.it e-mail: info@reer.it 16 8540554 19 Gennaio 2010 Rev.9