How to Configure the DE1 Variable Speed Starter for Reversing Motor Starting Applications.

Similar documents
Operating a PowerXL DC1/DE1 Drive with a Rockwell PLC on Ethernet/IP

Power Xpert incontrol One Installer Release Note

How to control and monitor up to 16 Motor Insight motor protection relays via an HMi and Modbus serial

Firmware Manual - EC Series Drives

DC1 Series 1 Hour Product Overview Eaton Corporation. All rights reserved.

PowerXL DG1 Firmware Release Note

Operating a Power Xpert C445 Global Motor Management Relay with a Rockwell PLC via Ethernet/IP

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

Variable Frequency Drive Design Guidelines

Adjustable Frequency Drives

TECO L510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

SSW06. Soft Starters.

Table of Contents. Safety. Attention. Warnings

QUICK REFERENCE GUIDE

Quick Start Guide Cutler-Hammer SVX9000 Drives from Eaton Corporation CONTENT STEP 1 Keypad Operation Overview STEP 2 Standard Wiring Diagrams and

GPD515/G5 Software Option (VSG114701) Part Number: CIMR-G5MXXXXXF-017 (1) (1) ZZZZ refers to the base Model Number

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Unidrive M400 (Frame 1 to 4) Quick Start Guide

Operating comfort redefined Frequency Inverters M-MAX

AP070002EN Differences between ELC series and ELC2 series PLCs

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

LS M100 Frequency Inverter Easy Start Guide

CATALOG SELECTION / PRODUCT SELECTION

Series G JG-Frame 310+ circuit breaker time current curves

Type S801, soft starters

Power Xpert C445 Competitive Comparison

Basic Drive Programming PowerFlex 755 Basic Start Up

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

PowerXL DG1 Redundant Drive Application

Smartstart Control Module

EQ5 SERIES Quick Start Guide for Constant Torque Applications

SVX9000 Adjustable Frequency Drives. Modular, Configurable, Compact

Baltimore Aircoil Company

Status line The top line of the LCD display shows the basic status information of the drive.

Flexible, simple, economical, robust.

Bosch Rexroth EFC3610 Frequency Inverter. Easy Start Guide L1 L2 L3 (+) B U V W

Galileo training: Logix platform DF1 RS232 driver and tag import

Step 1: Choose the Appropriate CPU Step 2: Make the Connections

DC1 Series 10 min Product Overview Eaton Corporation. All rights reserved.

Basic control panel. Features. Control panels 75

For Classroom Use Only! Flying Start PowerFlex 755 AC Drives

Intelligent Technologies QCPort Cover Control

Quick Start Guide RSi S Series VFD. Using the 7-segment (4 digit LED) Keypad/Display

Types R, RV, RX, VW, VWV, W, WV time- current curves

For normal duty, design the VFD voltage level at 480 Volt, 3 Phase, 60 Hertz. (In Canada, 600 Volt, 3 Phase, 60 Hertz.)

Eaton s SPD Series for integration into electrical distribution equipment

Low Voltage Drives. ABB component drives ACS55, 0.25 to 3 hp (0.18 to 2.2 kw) Catalog

Enclosed DOL Motor Starter Type 4x, Plastic, 3-Phase

FlexPak 3000 Drive Operator Interface Module (OIM) User s Guide

Variable Speed Drives

May Delivers real-time, Web-enabled monitoring of electrical distribution and control equipment

Taxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V Molded case circuit breaker

Intelligent Technologies (IT.) Starter Network Adapter Products (SNAP) Product Focus D77B-DSNAP D77B-QSNAP

PowerXL DX-NET-SWD SmartWire-DT Interface Module for Variable Frequency Drive/ Variable Speed Starter PowerXL

DRMS SERIES DIN RAIL MOUNT HYBRID MOTOR STARTERS

Delta C200 Series AC Drives

Quick Start Guide For GVX9000 AF Drives

Variable Speed Drives

E-Series Troubleshooting Guide

Contents. Volume 8 Sensing Solutions CA E February

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

SUPPLEMENTAL MANUAL FACTORY-INSTALLED LENZE AC TECH VARIABLE FREQUENCY DRIVES (VFD) IN RENEWAIRE (ERV) VENTILATORS TABLE OF CONTENTS

SED2 Variable Frequency Drives

18805 Adams Ct., #110 ~ Morgan Hill, CA 95037, USA ~ ~ ~

DXE-EXT-SET Configuration module

Product Guide. UL 1077 DIN Rail Supplementary Protectors

ABB AC500 Technical Help Sheet

For our complete product offering, see Volume 7 Motor Controls, Logic and Connectivity, CA E and PG E.

GS1 and GS2 Series AC Drives

ACE-SDC-V3 Stepper Driver +Controller with USB 2.0 Communication

The easy to use three-phase digital DC drive for regenerative and non-regenerative applications from HP

Mitsubishi D700-SC Frequency Inverter. Easy Start Guide. The Mitsubishi D700-SC Frequency Inverter range is available to order from inverterdrive.

Power Xpert Gateway 900 Advanced Color Touchscreen Display Quick Start Guide

SV9000 AF DRIVES SVReady User Manual. Pump and Fan Control Application

Important Safety Notice

Version 1.7. Module Firmware Version 4

SOFT STARTERS PLANET -LOGIC

Macro Guide. Affinity. Model sizes 1 to 6. Building Automation HVAC/R drive. Part Number: Issue: 1.

Aspire RF smart dimmer system masters

SMARTSTART MOTOR STARTERS

PROGRAMMING MANUAL IM262R00. AQUAVAR Intelligent Pump Controller START-UP GENIE PROGRAMMING MANUAL

Parameter Reference Guide. KBG2 Series. RFC-A Mode

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Easy Start Guide. Parker SSD Drives 650 Series Frequency Inverter available from Parker.InverterDrive.com

Application Note: Wiring Diagrams to replace DS2000 with DS2020

Section 0.0 Warnings... 2 Section 1.0 Quick Set-up... 3 Section 2.0 Description Section 3.0. Section 4.0. Section 5.0. Section 6.0. Section 7.

Section 0.0 Warnings... 3 Section 1.0 Quick Set-up... 4 Section 2.0 Description Section 3.0. Section 4.0. Section 5.0. Section 6.0. Section 7.

A66N2 Installation and Programming Manual

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

IMPORTANT! PLEASE READ!

Bus Regulation. PowerFlex 755 AC Drives. For Classroom Use Only!

Series NRX drawout circuit breaker and cassette rejection interlocks

ABB Component Drives ACS55, 0.25 to 3 Hp

Application Note. Applicable Products

PowerXL Series Trouble Shooting Guide

Z-Wave wireless smart master dimmer

Type 330SA High-Performance Electric Actuator

SmartWire-DT In-panel and on-machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

Transcription:

How to Configure the DE1 Variable Speed Starter for Reversing Motor Starting Applications. Application The DE1 Variable Speed Starter (VSS) offers the advantages of both a direct online (DOL) starter and a variable frequency drive (VFD) in a single device by providing the ease of use of a DOL starter and the variable motor speed of a variable frequency drive. The DE1 makes it possible to ensure a soft motor start that uses configured time parameters to take a motor to a defined speed with full torque at low motor RPM while avoiding inrush current peaks, enabling users to achieve the energy efficiency and product reliability required for their applications. Additionally, the DE1 can be easily configured for other applications such as basic starting and/or 2 speed applications. Overview The DE1 Variable Speed Starter can be quickly configured by using the DXE-EXT-SET configuration module to change default values if required by the application. This module snaps into the face of the DE1 enabling the user to configure Mains Frequency, Ramp Time, Fixed Frequency, Mode Selection and Motor FLA (protection) with only a small screwdriver. While other devices such as DriveConnect software, the DX-KEY-LED keypad, etc. may be used to configure the DE1, examples in this document refer to the use of the DXE-EXT-SET configuration module to provide a straightforward setup procedure when the DE1 is to be used for basic motor starting. Additional capabilities and configuration settings for the DE1 may be found in the DE1 User Manual. Contents DXE-EXT-SET Configuration Module Functionality... 2 Transfer parameter values of the DXE-EXT-SET module to the DE1... 3 DE1 Functionality Mode 0 Terminal Assignment... 3 DE1 Functionality Connection Diagram for a reversing starter application... 4

DXE-EXT-SET Configuration Module Functionality The DXE-EXT-SET configuration module is used for configuring the DE1 during setup operations and is normally removed from the DE1 for RUN operations, as all parameterization information resides within the DE1. NOTE: The DXE-EXT-SET module can only download the potentiometer values from the module into the DE1. The DXE- EXT-SET module cannot upload parameters from a DE1 into the module. The desired parameterization values can be adjusted prior to being connected to the DE1. The module is then connected to the DE1 that is in the STOP mode and the SET button is pressed to initiate the download. Parameterization values are found in Table 1: Table 1 Parameterization with the DXE-EXT-SET Configuration Module DE1 Parameterization DXE-EXT-SET Parameter Unit PNU Range Default Settings Ramp sec. P-03 0.1-300 5 0.1/1/3/5/10/15/30/60/120/180 P-04 0.1-300 Mode P-15 0-9 0 0-9 Fixed Frequency Hz. P-20 0-60 20 1-60 I motor Amps P-08 10% - 100% x I e 100% 10% - 100% x I e Supply Frequency Hz. P-09 50-60 60 50/60 NOTES: The DXE-EXT-SET module Ramp parameter sets both Start (P-03) and Stop (P-04) ramp parameters with the same value. I e = DE1 Frame Maximum I motor = Motor Nameplate FLA, establishes motor protection thresholds. I motor potentiometer setting for a 1.9A FLA motor is calculated by the following formula: I motor = Motor Nameplate FLA = 1.9A = 0.904 = 90% DE1-342D1 Rated Current 2.1A Supply Voltage parameter P-07 is not configurable with DXE-EXT-SET module. External keypad or drivesconnect software is required to change this parameter. Parameter P-07 default values are established by product catalog number when selecting Frame Size and Frequency. Reference Table 2 2 EATON CORPORATION www.eaton.com

Table 2 Supply Voltage Parameterization Supply Voltage Vac P-07 200-240 Vac ± 10% 230 60 Hz DX-KEY, Supply Voltage Vac P-07 400-480 Vac ± 10% 460 60 Hz drivesconnect Transfer parameter values of the DXE-EXT-SET module to the DE1 1. DE1 must be in STOP mode only, with supply voltage applied. 2. Press the SET button for 2 seconds. The status LED will flash (green) 3 times for 2 seconds. 3. Steady green status LED indicates all parameters have been successfully transferred from the module to the DE1. 4. The operating parameters will be used for Start/Run/Stop profiles in both forward and reverse directions. DE1 Functionality Mode 0 Terminal Assignment The DE1 has ten (10) terminal assignment profiles. Mode 0 is default and is recommended for basic motor control consisting of a Start ramp, acceleration to motor synchronous speed, and a Stop ramp. Mode 0 terminal assignments are; Terminal 1 / digital input 1 FWD (forward) START/RUN signal - forward Terminal 2 / digital input 2 REV (reverse) START/RUN signal - reverse Terminal 3 / digital input 3 FF1 (fixed frequency 1) not used Terminal 4 / digital/analog input 4 f-ref (frequency set point value) connected to Terminal +10V to provide a reference signal to command the motor to synchronous speed. 3 EATON CORPORATION www.eaton.com

DE1 Functionality Connection Diagram for a reversing starter application Figure 2 illustrates the connections required for operation of the DE1 in a reversing motor start configuration. Terminal 3 is not used in this type of configuration. When digital input 1 gets a signal, the DE1 will accelerate the motor in the forward direction with a ramp of 5 seconds (default value) to motor synchronous speed. The DE1 will operate at forward synchronous speed as long as digital input 1 remains signaled. When the signal is removed from digital input 1, the DE1 will decelerate the motor with a ramp time of 5 seconds (12Hz/second). When digital input 2 gets a signal, the DE1 will accelerate the motor in the reverse direction with a ramp of 5 seconds (default value) to motor synchronous speed. The DE1 will operate at reverse synchronous speed as long as digital input 2 remains signaled. When the signal is removed from digital input 2, the DE1 will decelerate the motor with a ramp time of 5 seconds (12Hz/second). Figure 3illustrates the control signal logic. Figure 2: Connection Diagram Figure 3: Signal Logic 4 EATON CORPORATION www.eaton.com

Additional Help In the US or Canada: please contact the Technical Resource Center at 1-877-ETN-CARE or 1-877-326-2273. All other supporting documentation is located on the Eaton web site at www.eaton.com Eaton 1000 Eaton Boulevard Cleveland, OH 44122 USA Eaton.com 2014 Eaton All Rights Reserved Printed in USA Publication No. AP040101EN April 2014 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners