Type ME43. Quickstart

Similar documents
Type Quickstart

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Type Quickstart (from device Version 2)

Fieldbus Gateway Type ME43

PTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Serial PROFIBUS Interface

Type ME23. Operating Instructions. Bedienungsanleitung Manuel d utilisation

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

BVS 16 ATEX E088 X, IECEx BVS X. Operating Instructions

CPCI-PS24 24V-Power Supply

Type 8694 Positioner TopControl Basic. Quickstart. English Deutsch Français

Electronic Temperature Controller. Instruction Manual Version

Type 8652 AirLINE. Quickstart. English Deutsch Français

PHOENIX CONTACT - 05/2007

Type Flow Transmitter / Pulse divider Durchflusstransmitter / Impulsteiler Transmetteur de débit / Diviseur d impulsions

MC 11 EB-2 Power supply cabinet with external bus, AC version

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Operating instructions. Standstill monitor A / / 2011

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

CMC III Universal Sensor

Operating instructions. Switching amplifier DN0210 DN / / 2015

Type MS04. Redox potential sensor cube. Operating Instructions

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

Digital input modules

CMC III Temperature/Humidity Sensor

Control Head. Quickstart. English

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Type 8791 Positioner SideControl BASIC. Quickstart. English / Deutsch / Français

Operating instructions. Speed monitor D / / 2014

MDM 011-Z1 Regen Resistor

crio PN Installation Instructions V0.2/ COMSOFT

Type 8652 AirLINE. Modular valve terminal for pneumatics. Operating Instructions

Type Operating Instructions - Software. Bedienungsanleitung - Software Manuel d utilisation - Logiciel

PHOENIX CONTACT - 01/2008

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Operating instructions IO-Link master CabinetLine AL19xx

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

IPCB42501 / IPCB42551

CPCI System Subrack 1 U

System Control Unit (SCU)

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Assembly Instructions scancontrol 2700/2750 (500)

PNOZ m ES ETH. Configurable Control System PNOZmulti. Operating Manual EN 04

MINI MCR-SL-PT100-UI(-SP)(-NC)

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Manual Version: V1.00. Video Decoder Quick Guide

Redundancy Module QUINT-DIODE/40

3/4 U CPCI Serial Case System

Technical Data. Dimensions

TU531, TU532 Terminal Unit

PHOENIX CONTACT - 07/2006

Troubleshooting Manual

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

PHOENIX CONTACT - 12/2007

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

MINI MCR-SL-PT100-UI-200

PI-EX-ME-2NAM/COC-120VAC

TF501, TF521 Terminal Bases

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

DN-DP PROFIBUS-DP / DeviceNet-Gateway

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

PI-EX-ME-2NAM/COC-24VDC

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Operating Instructions

User Manual HMI Linkbox HL01 DP/MPI

Digital electropneumatic positioner

AO523 Analog Input Module

FIELDBUS TECHNOLOGY ETHERNET- PROFIBUS- INTERFACE PB-XEPI F1144/ 03 INSTALLATION MANUAL

onlinecomponents.com

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

User Manual Gateway component for EtherNet/IP

PTZ Control VMC Joystick

Installation Manual TH LINK PROFINET. Version: EN Copyright 2014 Softing Industrial Automation GmbH

MINI MCR-SL-CVS NC

SUBCON-PLUS-PROFIB...

User Manual. Printer P-52RUE

TPC25 active crossover. user manual

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

TETRIS 2500 High Impedance Active Probe. Instruction Manual

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Installation manual plugs and connectors with screw connection (16/32 A)


SolConeX extra-low voltage flange socket

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Transcription:

Type ME43 Fieldbus gateway büs to Industrial Ethernet, PROFIBUS DPV1, CC-Link Feldbus-Gateway büs zu Industrial Ethernet, PROFIBUS DPV1, CC-Link Passerelle bus de terrain büs vers Ethernet industriel, PROFIBUS DPV1, CC-Link Quickstart

Contents 1 The Quickstart... 2 2 Intended use... 3 3 Basic safety instructions... 3 4 Technical data... 4 5 Installation...6 6 Start-up... 8 7 Operation and function... 8 8 Disassembly... 10 9 Packaging, transport Disposal... 11 1 THE QUICKSTART The quickstart contains the most important information and notes regarding the use of the device. Keep these quickstart ready to hand at the operation site. Important safety information. Carefully read these quickstart. Observe in particular the safety instructions, authorized use and operating conditions. Persons, who work on the device, must read and understand these instructions. The operating instructions can be found on the Internet at: www.burkert.com 1.1 Symbols indicates an instruction to prevent risks. Designates a procedure which you must carry out. MENUE Representation of software interface text. Warning of injuries: WARNING! Possible danger! Serious or fatal injuries. CAUTION! Danger! Moderate or minor injuries. NOTE! Warning of damage. 2

2 INTENDED USE The fieldbus gateway type ME43 is used as a field bus converter between büs and Industrial Ethernet, PROFIBUS DPV1, CC-Link. When using the device, observe the permitted data, operating conditions and application conditions. This information can be found in the contractual documents, the operating instructions and on the type label. In areas at risk of explosion, only use devices approved for use in those areas. These devices are labeled with a separate Ex type label. In use, note the information provided on the separate Ex type label and the additional explosion-related information or separate explosion-related operating instructions. The device Do not use the device outside. Do not open the device. Use the device only in conjunction with third-party devices and components recommended and authorized by Bürkert. Only operate the device when in perfect condition and always ensure proper storage, transportation, installation and operation. Use only as intended. 3 BASIC SAFETY INSTRUCTIONS These safety instructions do not consider any contingencies or incidents which occur during installation, operation and maintenance. The operator is responsible for observing the location-specific safety regulations, also with reference to the personnel. General hazardous situations. To prevent injury, ensure the following: Operate the device only in perfect condition and in accordance with the operating instructions. Do not make any changes to the device and do not subject it to mechanical stress. Secure device or system to prevent unintentional activation. Only trained technicians may perform installation and maintenance work. Install the device according to the regulations applicable in the country. After an interruption in the power supply, ensure that the process is restarted in a controlled manner. Observe the general rules of technology. 3

NOTE! Electrostatic sensitive components and modules. The device contains electronic components which react sensitively to electrostatic discharge (ESD). Contact with electrostatically charged persons or objects are hazardous to these components. In the worst case scenario, these components will be destroyed immediately or will fail after starting up. To minimize or eliminate the risk of damage resulting from sudden electrostatic discharges, ensure compliance with the requirements of EN 61340-5-1. Do not touch electronic components while the supply voltage is switched on! 3.1 Definition of the term device In these instructions the term device denotes the following device types: ME43 Ex area: stands for explosion-risk area Ex approval: stands for approval in the potentially explosive area 4 TECHNICAL DATA 4.1 Conformity The device conforms to the EU Directives as per the EU Declaration of Conformity (if applicable). 4.2 Standards The applied standards, which are used to demonstrate conformity with the EU Directives, are listed in the EU type examination certificate and/or the EU Declaration of Conformity (if applicable). 4.3 Operating conditions WARNING! Risk of injury due to malfunction if device used outdoors. Do not use the device outdoors and avoid heat sources which may cause the permitted temperature range to be exceeded. Permitted ambient temperature range: -20 C to +60 C Operating altitude: 4.4 Mechanical data Housing material: Polycarbonate up to 2000 m above sea level 4

4.5 Electrical data Supply voltage: 24 V ±10 % - residual ripple 10% Power consumption < 2 W Degree of protection: IP 20 according to EN 60529 / IEC 60529 (only if cables, plugs and sockets have been connected correctly) verified by Bürkert, not evaluated by UL Protection class: 3 according DIN EN 61140 (VDE 0140) Interfaces PROFIBUS version: CC-LINK version: 1 spring-type terminal 5-pin for supply voltage and büs connection 1 plug-in connector D-Sub, 9-pin 1 plug-in connector D-Sub, 9-pin Industrial Ethernet version: 2 sockets for RJ45 plug-in connector UL Devices: Limited Energy Circuit (LEC) according to UL/ IEC 61010-1 Limited Power Source (LPS) according to UL/ IEC 60950 SELV/ PELV with UL Recognized Overcurrent Protection dimensioned according to UL/ IEC 61010-1 Table 18 NEC Class 2 power source 4.6 Type label, device labeling Identification number of the device QR code (link for further information to the device) Permitted ambient temperature range Fig. 1: Description of type label and device labeling Type Serial number Manufacture code CE mark Supply voltage, Nominal power, Degree of protection 5

5 INSTALLATION WARNING! Risk of injury from improper installation. Installation may be carried out by authorized technicians only and with the appropriate tools. 5.1 Mounting on top hat rail Electrical connection upwards: Mount device in the lower guide of the top hat rail. Push device upwards while also swiveling it to the left; lock it into the upper guide of the top hat rail. Electrical connection downwards: Mount device in the upper guide of the top hat rail. Push device downwards while also swiveling it to the left; lock it into the lower guide of the top hat rail. 5.2 Electrical connection Connect 5-pin spring-type terminal in accordance with configuration. Color of terminal Description Red Supply voltage 24 V White CAN H (büs connection) Green Shielding Blue CAN L (büs connection) Black GND Tab. 1: Configuration of 5-pin spring-type terminal 5.3 Establishing connection to fieldbus Fig. 2: 8 7 6 5 4 3 2 1 Plug configuration Pin RJ45 1 TX+ 2 TX 3 RX+ 4, 5 not used 6 RX 7, 8 not used Configuration of X1 and X2 interfaces; connection to fieldbus 6

Insert the Ethernet cable into the sockets of the X1 and X2 interfaces. The X1 and X2 interfaces for RJ45 plug-in connectors are equivalent. NOTE! To ensure electromagnetic compatibility (EMC) Only use shielded Ethernet cables. Connect the Ethernet cables of all devices to the top hat rail to ground the cable shielding. 5.3.1 CC-Link version Configuration of plug-in connector D-Sub, 9-pin D-Sub, 9-pin Pin Signal Function Connection 1 and 2 not used 1 3 DA Data line minus Mandatory 6 2 (A conductor) 7 3 4 DG Data ground Mandatory 8 4 5, 6 and 7 not used 9 5 8 DB Data line plus Mandatory (B conductor) 9 not used Fig. 3: CC-Link, Belegung Steckverbinder D-Sub 9-polig 5.3.2 PROFIBUS version Configuration of plug-in connector D-Sub, 9-pin D-Sub, 9-pin Pin Signal Funkcion Connection 1 and 2 not used 3 RxD/TxD-P Data line minus (A conductor) Mandatory 4 CNTR-P Repeater directional control Optional 1 6 2 5 DGND Ground for data Mandatory 7 3 signals and VP 8 4 9 6 VP +5 V supply for Optional 5 bus terminating resistor 7 and 9 not used 8 RxD/TxD-N Data line plus (B conductor) Mandatory Fig. 4: PROFIBUS, Configuration of plug-in connector D-Sub, 9-pin 7

6 START-UP 8 WARNING! Risk of injury from improper operation! Only trained and qualified personnel may start up the device or system. The following base settings can be made on the display of the device: Set IP address Fieldbus versions: set PROFIBUS address or CC-Link address Select protocol (not with PROFIBUS version and CC-Link address) The description for configuration and parameterization of the Typ ME43 can be found in the operating instructions. The Bürkert Communicator PC software and the büs stick, which is available as an accessory, are required for configuration. The Bürkert Communicator software and a general description of it are available on the Bürkert homepage. 7 OPERATION AND FUNCTION WARNING! Only adequately trained personnel may operate the system or device. Operation using the display is achieved by means of the two arrow keys and the round menu key. Opening the main menu: Press the menu key twice. First the start screen appears, then the main menus with the detailed views Parameter, Diagnostics and Maintenance. Returning from a menu: Using the arrow keys, select Exit or Abort or Save and confirm using the menu key. 7.3.1 Description of the keys Element Description Arrow Page down through menu keys Decrease numerical values Menu key Open main menu Confirm selection, confirm input. Tab. 2: Description of the keys

7.1 Settings of the fieldbus gateway ME43 The following functions can be adjusted or read on the display and also with the PC software Bürkert Communicator. Function Further functions for the setting and configuration of the device are offered by the PC software Bürkert-Communicator. Set IP address. Field bus versions: set PROFIBUS address or CC-Link address. See operating instructions Start-Up. Select protocol. See operating instructions Setting up the büs network Setting on display Parameter Setting with Bürkert Communicator Industrial communication Parameter Setting display brightness Parameter General contrast installation position settings Parameter Function Setting on display Setting with Bürkert Communicator Restart device Maintenance General Information Ident.-number settings about the Serial number Maintenance device Software version Hardware version büs version ICom version Maintenance Industrial communication Maintenance Tab. 3: Settings of the fieldbus gateway ME43 7.2 Operation of type ME 43 with the software Bürkert Communicator The device can be configured on the PC using the Bürkert Communicator software. A detailed description of the operation and configuration of the PC software Bürkert Communicator can be found on the website www. burkert.com Type 8920. 9

7.3 Micro SD card The Micro SD card can be used to save and transfer device-specific values and user settings to a different device. Card holder for Micro SD card Carefully pull the cover out of the recess and rotate it upwards to the left. Remove the Micro SD card: Press on the edge of the engaged Micro SD card to unlock it. 8 DISASSEMBLY WARNING! Risk of injury from improper disassembly. Disassembly may be carried out by authorized technicians only. 1. Switch off supply voltage 2. Remove 5-pin spring-type terminal. Fig. 5: Micro SD card; fieldbus gateway ME43 The Micro SD card is not suitable for backups. If the Micro SD card of the device is re-inserted at a later date, the most recently saved data is not restored. Do not use conventional retail Micro SD cards for the device. The Micro SD card is available as an accessory. 3. Remove Ethernet cable from the X2 and X2 interfaces. For the PROFIBUS version and CC-Link version: Remove plug-in connector D-Sub, 9-pin. 4. Remove the device from the top hat rail Push the device upwards and detach it from the upper guide of the top hat rail 10

9 PACKAGING, TRANSPORT DISPOSAL NOTE! Damage in transit due to inadequately protected devices. Protect the device against moisture and dirt in shock-resistant packaging during transportation. Observe permitted storage temperature. Incorrect storage may damage the device. Store the device in a dry and dust-free location. Storage temperature: -30 C to +80 C. Damage to the environment caused by device components contaminated with media. Dispose of the device and packaging in an environmentally friendly manner. Observe applicable disposal and environmental regulations. 11

Bürkert Fluid Control Systems Sales Center Christian-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel. + 49 (0) 7940-10-91 111 Fax + 49 (0) 7940-10-91 448 E-mail: info@de.burkert.com International address www.burkert.com Manuals and data sheets on the Internet : www.burkert.com Bedienungsanleitungen und Datenblätter im Internet: www.buerkert.de Manuels d'utilisation et fiches techniques sur Internet: www.buerkert.fr Bürkert Werke GmbH & Co. KG, 2017 Operating Instructions 1711/00_EU-ML_00810655 / Original DE www.burkert.com