Protistor size 22x58 ar 690VAC (IEC) / 700VAC (UL)

Similar documents
Protistor size 14x51 gr 690VAC (IEC) / 700VAC (UL)

Protistor size 14x51 gr 690VAC (IEC) / 700VAC (UL)

Protistor size 2x72 and 2x73 ar 550 to 1250VAC (IEC)

NH fuse-links gg VAC with striker size 0, 1, 2, 3, 4

Ferrule fuse-links 14x51 am 500 to 690VAC

Ferrule fuse-links 22x58 am 500 to 690VAC

Ferrule fuse-links 10x38 gg 400 to 690VAC

Limitor - PD Back-up Fuses without Controlled Power Dissipation

L50QS SERIES HIGH-SPEED ROUND BODY FUSES

Industrial fuses NFC-DIN industrial fuselinks gg and am curves from 0.16 to 1250 A

DC Square-body Fuses Sizes 120 to 123 gr 750V DC

FLQ SERIES MIDGET (10x38mm) FUSES

AMP-TRAP Form 101 A15QS

Semiconductor (AC) fuses

Semi conductor fuses PSC 690 V DIN 43620

FUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC

TRADITIONAL HIGH-SPEED FUSES

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR-A, & JCR-B. R-Rated Fuses For Motor Circuit Protection Medium Voltage.

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

4. CIRCUIT BREAKERS. Functional Emergency Switching

L70S SERIES HIGH-SPEED FUSE

60103 Circuit Breaker

ECNR/ECSR Class RK5 Dual-Element Time-Delay Fuses. Catalog Number ECNR (1-600A) 250Vac or Less Catalog Number ECSR (1-600A) 600Vac or Less

10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

L50S SERIES HIGH-SPEED FUSE

L70S SERIES HIGH-SPEED FUSE

Non-Fusible Disconnect Switches

TeSys contactors 5. Selection 5. For utilisation category AC-3. Operational current and power conforming to IEC (θ y 60 C) Contactor size

1492-SP Supplementary Protectors

Miniature Circuit-Breaker IEC Series 8562

Applying branch circuit breakers and supplementary protectors in North America

Bulletin 1489 Circuit Breakers. Selection Guide

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Non-Fusible Disconnect Switches

PS2328 Integrated Power. System

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

L70QS SERIES HIGH-SPEED ROUND BODY FUSES

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Applying branch circuit breakers and supplementary protectors in North America

Miniature Circuit Breakers and Supplementary Protectors. Contents

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

C E R T I F I C A T E O F C O M P L I A N C E

Product Guide. UL 1077 DIN Rail Supplementary Protectors

UL 489 DIN rail branch circuit breakers

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

SPXI SERIES IN-LINE SOLAR FUSE

Digital ac/dc (24V) Input Module

CABLE PROTECTORS /SPECIAL PURPOSE

Section 4 Ground-Fault Protection Devices

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

UL 489 DIN Rail Miniature Circuit Breakers

Allen-Bradley 1492-RCDA4A40

Supplement to Instruction Manual

Metal Oxide Varistor (MOV) Data Sheet

920 Remote Control (RC) Switches

Now even more application possibilities In all facets of semiconductor protection

TeSys IEC Contactors and Overload Relays

UL 489 DIN Rail Miniature Circuit Breakers

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

System Specifications

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

ASCO 920 Remote Control (RC) Switches

IELR Rail-Mount Series Magnetic Circuit Protectors

Selection Guide. Control Circuit and Load Protection

IELR Series

Special Purpose Fuses

Special Purpose Fuses

The International Power Quality Resource

Datasheet Stock No: RS Pro

MEDIUM VOLTAGE FUSES. POWR-GARD Fuse Datasheet. 2,400-38,000 VAC Current-Limiting

Motor protection relays

S8VE (60/90/120/180/240-W Models)

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Time Delay Values (E-Series)

Metal Oxide Varistor (MOV) Data Sheet

Metal Oxide Varistor (MOV) Data Sheet

Metal Oxide Varistor (MOV) Data Sheet

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

The safest way to switch power on and off in your industrial control panels.

Metal Oxide Varistors (MOV) Data Sheet

Metal Oxide Varistors (MOV) Data Sheet

Jtec 10kA Miniature Circuit Breaker

System Specifications

Metal Oxide Varistor (MOV) Data Sheet

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

Selection Guide. Control Circuit and Load Protection

For Sales and Support call KMParts.com (866)

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

Current Limiting Protector

Ihr autorisierter Distributor: Neumüller Elektronik GmbH

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Transcription:

690VAC (IEC) / VAC (UL) Protistor size 22x58 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor protection Extremely fast acting Current limiting Excellent cycling capability UL recognized ar-class according to 60269-4 APPLICATIONS These Protistor size 22x58 have been designed to protect power semi conductors, complying with standard IEC 60269-4. They are extremely high interrupting rating fuses with large band of ratings (current rating 25 to 135A). Two models are existing: with or without striker. TECHNICAL DATA OVERVIEW Voltage AC 690 VAC AC IEC: 690V Rated Voltage AC UL: V DC UL: V Ampere Range (A) 25... 135 A Speed/Characteristic ar I.R. AC (IEC) 160 ka I.R. AC (UL) ka I.R. DC (UL) ka Protection of small inverters Protection of UPS systems Protection of variable speed drives Protection of other similar V or less equipments STANDARDS IEC 60269-4 UL recognized CSA RoHS compliant EP.MERSEN.COM 1

690VAC (IEC) / VAC (UL) PRODUCT RANGE Size 22x58 ar with striker Catalog Item Rated voltage AC (IEC) Rated current In Pre-arcing I²t Clearing I²t at Rated Voltage Rated breaking capacity AC Power dissipation at In Package Weight FR22AR69V25T B1056667 690 V 25 A 32.4 A²s A²s 160 ka 8.5 W 10 57 g FR22AR69V32T C1056668 690 V 32 A 60.3 A²s 6 A²s 160 ka 10.5 W 10 57 g FR22AR69V40T D1056669 690 V 40 A 101.8 A²s 9 A²s 160 ka 12 W 10 57 g FR22AR69VT E10566 690 V A 217.6 A²s 18 A²s 160 ka 13.4 W 10 57 g FR22AR69V63T F1056671 690 V 63 A 386.8 A²s 3 A²s 160 ka 15.5 W 10 57 g FR22AR69V80T G1056672 690 V 80 A 840.1 A²s 6800 A²s 160 ka 16 W 10 57 g FR22AR69VT H1056673 690 V A 1890 A²s 10 A²s 160 ka 17.8 W 10 57 g FR22AR69V125T J1056674 690 V 125 A 2897 A²s 15 A²s 160 ka 22.8 W 10 57 g FR22AR69V135T K1056675 690 V 135 A 3360 A²s 18 A²s 160 ka 27 W 10 57 g Size 22x58 ar without striker Catalog Item Rated voltage AC (IEC) Rated current In Pre-arcing I²t Clearing I²t at Rated Voltage Rated breaking capacity AC Power dissipation at In Package Weight FR22AR69V25 Y1027316 690 V 25 A 32.4 A²s A²s 160 ka 8.5 W 10 57 g FR22AR69V32 Z1027317 690 V 32 A 60.3 A²s 6 A²s 160 ka 10.5 W 10 57 g FR22AR69V40 A1027318 690 V 40 A 101.8 A²s 9 A²s 160 ka 12 W 10 57 g FR22AR69V B1027319 690 V A 217.6 A²s 18 A²s 160 ka 13.4 W 10 57 g FR22AR69V63 C1027320 690 V 63 A 386.8 A²s 3 A²s 160 ka 15.5 W 10 57 g FR22AR69V80 D1027321 690 V 80 A 840.1 A²s 6800 A²s 160 ka 16 W 10 57 g FR22AR69V E1027322 690 V A 1890 A²s 10 A²s 160 ka 17.8 W 10 57 g FR22AR60V125 F1027323 690 V 125 A 2897 A²s 15 A²s 160 A 22.8 W 10 57 g FR22AR60V135 G1027324 690 V 135 A 3360 A²s 18 A²s 160 ka 27 W 10 57 g EP.MERSEN.COM 2

690VAC (IEC) / VAC (UL) TIME CURRENT CHARACTERISTIC CURVES 0 Pre-arcing time (s) C C' 25 A 30 20 32 A 10 7 5 40 A 3 A 2 1 63 A 0.7 0.5 80 A 0.3 0.2 A 0.1 0.07 125 A 0.05 0.03 0.02 0.01 0.007 0.005 0.003 0.002 0.001 0.0007 0.0005 0.0003 0.0002 0.0001 10 20 30 RMS value of prospective current (A) +/- 8% 0 135 A 0 0 0 0 00 EP.MERSEN.COM 3

690VAC (IEC) / VAC (UL) CUT-OFF CURRENT CHARACTERISTIC 00 Maximum peak let thru current Ic (A) 00 00 00 0 0 0 0 0 lm = 23 lp 135 A 125 A A 80 A 63 A A 40 A 32 A 25 A 0 0 0 0 0 00 00 00 00 00 000 000 000 000 Hz RMS symmetrical prospective current Ip (A) I²T MULTIPLIER COEFFICIENT Clearing I²t and arcing time correction factor 1,1 1 0,9 0,8 0,7 0,6 0,5 0,4 0,3 400 Applied AC voltage (V) 600 800 EP.MERSEN.COM 4

690VAC (IEC) / VAC (UL) CHARACTERISTICS TOTAL I²T CURVE Operating I²t (A²s) 00 00 00 0 0 0 0 0 135 A 125 A A 80 A 63 A A 40 A 35 A 25 A 0 0 0 0 0 00 00 00 00 00 000 000 000 000 000 1e+06 Hz RMS symetrical prospective current (Ip)(A) POWER DISSIPATION Correction factor for power dissipation 1 0,8 0,6 0,4 0,2 0 20 30 40 % of rated current 60 80 90 EP.MERSEN.COM 5

690VAC (IEC) / VAC (UL) PEAK ARC VOLTAGE 1 Peak arc voltage (V) 1400 1 1 1 0 900 800 600 400 600 800 Applied AC voltage (V) DIMENSIONS Size 22x58 ar without striker +0.1 58-2 Dimensions in mm 57,5 Ø 22.2 ± 0.1 EP.MERSEN.COM 6

690VAC (IEC) / VAC (UL) DIMENSIONS Size 22x58 ar with striker 0.5 Visual indicator Ø 22.2 ± 0.1 58 +0.1-2 Dimensions in mm EP.MERSEN.COM 7