3D registration of micro-ct images for the identification of trabecular fracture region.

Similar documents
2008 International ANSYS Conference

FEMORAL STEM SHAPE DESIGN OF ARTIFICIAL HIP JOINT USING A VOXEL BASED FINITE ELEMENT METHOD

Geometrically accurate 3D FE models from medical scans created to analyse the causes of sports injuries

Grey value images as a basis for finite element models and their mechanical properties

David Wagner, Kaan Divringi, Can Ozcan Ozen Engineering

A New Quantitative Approach for Measuring Changes of 3D Structures in Trabecular Bone

A New Quantitative Approach for Measuring Changes of 3D Structures in Trabecular Bone

The Anatomical Equivalence Class Formulation and its Application to Shape-based Computational Neuroanatomy

Available online at ScienceDirect. Procedia Engineering 161 (2016 ) Bohdan Stawiski a, *, Tomasz Kania a

How does the ROI affect the thresholding?

Annales UMCS Informatica AI 1 (2003) UMCS. Registration of CT and MRI brain images. Karol Kuczyński, Paweł Mikołajczak

Prostate Detection Using Principal Component Analysis

Semantic Context Forests for Learning- Based Knee Cartilage Segmentation in 3D MR Images

CHARACTERISATION OF WAVINESS DEFECTS IN INDUSTRIAL COMPOSITE SAMPLES

Micro-CT analysis of mouse long bones (proximal tibia, distal femur)

Surface roughness parameters determination model in machining with the use of design and visualization technologies

Determination of Mechanic Resistance of Osseous Element Through Finite Element Modeling

Conference Biomedical Engineering

Evaluation of Credibility and Limitations of the Non- Rigid Registration of Micro-CT Images as a Tool for Local Strain Analysis

MEASURING CHANGES OF 3D STRUCTURES IN HIGH-RESOLUTION µct IMAGES OF TRABECULAR BONE

Performance Evaluation of 3-Axis Scanner Automated For Industrial Gamma- Ray Computed Tomography

Non-Linear Analysis of Bolted Flush End-Plate Steel Beam-to-Column Connection Nur Ashikin Latip, Redzuan Abdulla

An Improved Tracking Technique for Assessment of High Resolution Dynamic Radiography Kinematics

Cannulated Screw System. Surgical Technique

True Advancements for Longitudinal Weld Pipe Inspection in PA

ANATOMIA Tutorial. Fig. 1 Obtaining CT scan data

Segmentation of Bony Structures with Ligament Attachment Sites

Method note. Page 1 of 7

Acknowledgements. Atlas-based automatic measurements of the morphology of the tibiofemoral joint

Computerized determination of the ischio-iliac angle from CT images of the pelvis

3D Numerical Analysis of an ACL Reconstructed Knee

Efficient Image Compression of Medical Images Using the Wavelet Transform and Fuzzy c-means Clustering on Regions of Interest.

8/3/2017. Contour Assessment for Quality Assurance and Data Mining. Objective. Outline. Tom Purdie, PhD, MCCPM

Fatigue Simulation of Human Cortical Bone using Non-Homogeneous Finite Element Models to Examine the Importance of Sizing Factors on Damage Laws

Predicting the mechanical behaviour of large composite rocket motor cases

microct Systems for Life Science Innovation with Integrity High Resolution Microtomography for in vivo and ex vivo Applications Microtomography

Enhanced material contrast by dual-energy microct imaging

Morphometric Analysis of Biomedical Images. Sara Rolfe 10/9/17

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT

SIMULATION OF BONE AGING AND VIRTUAL REALITY VISUALIZATION OF CANCELLOUS BONE STRUCTURE

μct for the Pharmaceutical Industries Innovation with Integrity From R&D to Production, Inspection and Failure Analysis Microtomography

Visualisation : Lecture 1. So what is visualisation? Visualisation

DARWIN 8.1 Release Notes

Using Probability Maps for Multi organ Automatic Segmentation

2. Equipment, specimens and inspection procedures

3D Computed Tomography (CT) Its Application to Aerospace Industry

ULTRAVISION 3.7R21. Product Bulletin. UltraVision, a complete UT and Phased Array inspection package!

New York State Regents Examination in Geometry (Common Core) Performance Level Descriptions

A biometric iris recognition system based on principal components analysis, genetic algorithms and cosine-distance

Character Recognition

An open source software tool to assign the material properties of bone for ABAQUS finite element simulations

3D VISUALIZATION OF SEGMENTED CRUCIATE LIGAMENTS 1. INTRODUCTION

LEVEL-SET METHOD FOR WORKSPACE ANALYSIS OF SERIAL MANIPULATORS

Using X-Ray Micro Tomography to assess the quality of Packaging Foil

Document Version: Publisher s PDF, also known as Version of Record (includes final page, issue and volume numbers)

Correction of refraction. volume deformation measurements

CT IMAGE PROCESSING IN HIP ARTHROPLASTY

TOLERANCE ANALYSIS OF THIN-WALL CFRP STRUCTURAL ELEMENTS USING TOMOGRAPHIC IMAGING

arxiv: v1 [cs.cv] 11 Apr 2018

Machine Learning for Medical Image Analysis. A. Criminisi

Comparison of fiber orientation analysis methods in Avizo

CHAPTER 7 SIMULATIONS OF EXPERIMENTAL WORK PERFORMED ON COMPOSITE SPECIMENS BY USING ANSYS

Texture Analysis in Quantitative Osteoporosis Assessment

Network Traffic Measurements and Analysis

Thresholding technique for accurate analysis of density and geometry in QCT, pqct and ÌCT images

University of Florida CISE department Gator Engineering. Data Preprocessing. Dr. Sanjay Ranka

Additional file 1: Online Supplementary Material 1

Derivation of Draft FlexPLI prototype impactor limits by BASt

How to Analyze Materials

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography

CNC Milling Machines Advanced Cutting Strategies for Forging Die Manufacturing

A Study of Medical Image Analysis System

DEFORMABLE MATCHING OF HAND SHAPES FOR USER VERIFICATION. Ani1 K. Jain and Nicolae Duta

Computed tomography (Item No.: P )

Elastic registration of medical images using finite element meshes

Applying Hounsfield unit density calibration in SkyScan CT-analyser

Image Registration with Local Rigidity Constraints

ScienceDirect. The use of Optical Methods for Leak Testing Dampers

Data Preprocessing. Data Preprocessing

Automatic Modelling Image Represented Objects Using a Statistic Based Approach

An Ensemble Approach for Record Matching in Data Linkage

User Guide. Customized Patient Instrumentation Web Based Surgical Planning and Tracking Software Guide

THE EFFECT OF THE FREE SURFACE ON THE SINGULAR STRESS FIELD AT THE FATIGUE CRACK FRONT

THE USE OF OPTICAL METHODS FOR LEAK TESTING DAMPERS

Prototype of Silver Corpus Merging Framework

Spherical Geometry Selection Used for Error Evaluation

Digital Volume Correlation for Materials Characterization

Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset

TRANSFORMATIONS AND CONGRUENCE

Learning-based Neuroimage Registration

Equipment Site Description

Parametric Investigation of Single Point Incremental Forming For Al 8011A H-14

2 Michael E. Leventon and Sarah F. F. Gibson a b c d Fig. 1. (a, b) Two MR scans of a person's knee. Both images have high resolution in-plane, but ha

Motion artifact detection in four-dimensional computed tomography images

Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-ct bone analysis

A Generation Methodology for Numerical Phantoms with Statistically Relevant Variability of Geometric and Physical Properties

Mirrored LH Histograms for the Visualization of Material Boundaries

Fingerprint Recognition using Texture Features

Measurements using three-dimensional product imaging

Validation of a Finite Element Analysis (FEA) Model of a Nuclear Transportation Package under Impact Conditions

Transcription:

3D registration of micro-ct images for the identification of trabecular fracture region. S. Tassani 1,2, P.A. Asvestas 3, G.K. Matsopoulos 1, and F. Baruffaldi 2 1 Institute of Communication and Computer System, School of Electrical and Computer Engineering, National Technical University of Athens, Athens, Greece 2 Laboratorio di Tecnologia Medica, Istituti Ortopedici Rizzoli, Bologna, Italy, 3 Department of Medical Instruments Technology, Faculty of Technological Applications, Technological Educational Institute of Athens, Athens, Greece Aims Microtomographic devices (Micro-CT) are commonly used for in-vitro analysis of trabecular bone structure and its relation to the mechanical behavior of the tissue. The standard examination for the evaluation of the trabecular resistance to load is the assessment of its bone volume fraction (BV/TV) [1, 2]. Even though the BV/TV has been proved to correlate to fracture behavior, it does not allow to determine structural changes within the cancellous bone microarchitecture, which was found to have an important effect on bone strength [3]. Particularly, in [4], a 17% of wrong fracture zone identification was recorded using only BV/TV as a classifier. This quite high classification error was achieved in a situation of controlled involvement of the trabecular structure (i.e. reduced off-axis angle [5]) and with half of the specimen identified as broken (maximum classification error 50%). The correct identification of the trabecular broken region have a potential impact in the understanding of the structural mechanisms driving the mechanical fracture of bone, by the calculation of morphometric parameters in the actual broken region instead of the whole specimen. Image processing tools, as 3D image registration, were already presented in literature for the study of mechanical behavior of bone tissue [6]. The combined use of image guide failure analysis of micro-ct datasets and the mechanical tests can lead to a more comprehensive study of the fracture behaviour in the near future. Aim of the present work is to present a new methodological approach for the automatic identification of trabecular bone fracture zone based on 3D image registration. Method Bone Specimens extraction and Micro-CT scanning Five cylindrical specimens of trabecular bone, with a diameter of 10 mm and a height of 26 mm, were extracted from the epiphysial slices, i.e. femoral condyles, tibial plateau and distal tibia, by means of a holed diamond-coated milling cutter. Trabecular specimens were acquired using a micro-ct device (model Skyscan 1072, Skyscan, Kontich, Belgium) and applying a previously published protocol [7]. The same acquisition procedure was performed before and after the mechanical test (see below). Global fixed threshold was used for the segmentation of trabecular specimens and the measurement of morphometric parameters (see below) as previously reported in literature [7].

Mechanical testing All specimens underwent compressive testing [5]. Each specimen was cemented directly onto the testing machine (Mod. 8502, Instron Corp., Canton, MA, USA) to ensure the alignment between the testing direction and the specimen axis. The specimen free length was set to 20 mm. Before testing, the specimen was immersed in Ringer s solution for an additional hour. Each specimen was compressively loaded until failure, with a strain rate of 0.01 s-1 [1, 8, 9]. Visual inspection for the identification of the broken region A comparison was performed by three operators in the datasets acquired before and after the mechanical compression for the identification of the broken regions. These regions were identified visually, by comparing the stack of pre- and post-failure micro-ct cross-sections (slices) over the whole free height of the specimens, using the pre-failure cross sections as reference. Depending on the presence or absence of trabecular fracture in the post-failure micro-ct slices, each of the corresponding pre-failure slice was labeled as a broken crosssection or unbroken cross-section. Consistency threshold was identified based on the measures of the operators. The automatic registration method Automatic identification of the fracture zone was performed by the application of 3D automatic registration method applied on the acquired data sets. For each specimen, two data sets were acquired: the pre-failure data set and the post-failure data set, after mechanical compression. The purpose of the 3D registration is to automatically identify the zone on the pre-failure set that corresponds to the fracture zone of the post-failure data set. The method presented is a surface-based registration which involves the determination and matching of the surfaces of the two sets and the minimization of a distance measure of these corresponding surfaces [10, 11]. The transformation model employed was the rigid transformation model [12]. No scaling was used. Identification of the fracture zone using the automatic registration procedure For all the acquired data the automatic registration procedure was applied. Two subsets of the post-failure set were defined: the upper and the lower subsets relatively to the fracture zone. The upper subset was formed from slices of the post-failure set from the first upper slice of the set up to a randomly selected slice located above the fracture zone that clearly corresponds to an unbroken region, whereas the lower subset was formed from slices of the post-failure set from the lowest slice up to a randomly selected slice located below the fracture zone that also clearly corresponds to an unbroken region. The proposed registration method was applied twice: the first registration involving the upper subset with the pre-failure set and the second registration the lower subset with the pre-failure set (Figure 1).

Figure 1 The volume registrations steps are shown. (a) The pre and post-failure sets. The float set is registered on the reference set. The procedure is applied twice: one involving the upper subsets of both sets (b) and the other involving the lower subsets (c). The regions belonging to clearly unbroken regions coincide while the regions belonging to the fracture zone (red fracture zone) present misalignments. Full 3D identification of broken region A full 3D definition of the broken region (ROI), not related to the identification of broken slices, was performed starting from the 3D distribution of misaligned ROIs. The 3D volume (VOI) was identified applying a dilation procedure around the misaligned ROIs. Every ROI was dilated in every direction of 0.5mm obtaining for every ROI an ellipsoidal VOI centered on broken trabecula. When ROIs were close enough, the VOIs were fused creating a single 3D VOI. Validation of the registration procedure The procedure has been applied on 5 specimens, which have previously been mechanically tested. The outcome of the 3D registration, the fracture zone, was compared to the broken regions as visually identified by the operators. When differences between the two procedures were greater than the consistency threshold identified during the visual inspection, the operators were asked to verify if the error was due to the 3D registration approach or the visual one. Results Five trabecular bone specimens were mechanically tested in compression and acquired by means of a micro-ct device before and after the mechanical test. Figure 2 shows the result of applying the automatic registration procedure on a specimen underwent mechanical testing in order to define the fracture zone. Pre and post-failure sets were compared (Figure 2 a) and the broken region was identified both visually and automatically in order to identify the starting and ending broken slides. A plot for the identification of the fracture zone was obtained by the automatic registration procedure (blue line) while the visual inspection of the observers gave as result the starting and ending broken slides (red straight lines) (Figure 2 b). Finally the full 3D identification of the broken structure was performed for every specimen (Figure 2 c).

Fig. 2 The whole identification process is shown. (a) Micro-CT volumes of the bone specimen before and after the mechanical test are shown. (b) The visual procedure by the observers is compared to the automatic identification of the fracture zone. The percentage of overlapping of all ROIs for each slice as obtained by the proposed registration procedure is shown in the graph. (c) Finally a full 3D broken region is identified. The visual approach and automatic registration procedure were in agreement in 7 out of 10 cases. In fact, the difference between the procedures was smaller than the operators variability in the identification (18 slices). In the last three cases, the visual approach and the automatic registration procedure disagreed of 37, 76 and 103 slices. For these cases, the operators had to compare their findings against the ones suggested by the automatic registration procedure. In all three cases, the operators had to correct their findings suggesting that the proposed automatic registration procedure was successfully performed and the identification of the fracture zone was correct. The full 3D broken region was also identified for every specimen (Figure 2 c). Through this kind of visualization was possible to identify the 3D shape of every principal and secondary broken region. Moreover, was possible to identify some single broken trabeculae. Once again the operators were asked to verify the presence of the broken trabeculae. Operators agreed in the validation of the principal broken region fully 3D identified. Moreover, operators generally agreed with the automatic identification of single broken trabeculae, but in some cases they disagreed among themselves. Conclusion Aim of the present work was to present a new methodological approach for the automatic identification of trabecular bone fracture zone, based on 3D image registration. The technique was presented and validated against the visual approach of three expert operators. The presented study has shown comparable results between the visual approach and the automatic registration procedure, in the identification of the principal broken region. Moreover, the execution time for the application of the proposed registration procedure was 50 sec in total, for all data sets within this study. This result in a substantial reduction of the time for the identification of the fracture zone compared with the 20 to 30 minutes that required for the visual approach by each observer. Image guide failure analysis is becoming an important field of study for the comprehension of bone mechanical behavior. New technologies are nowadays able to produce huge amount of data, but researchers need more tools for a more exhaustive mechanical study. The combined use of image guide failure analysis of micro-ct datasets and the mechanical tests can lead to a more comprehensive study of the fracture behaviour in the near future. In conclusion, a novel procedure for the identification of trabecular bone fracture zone was presented and validated throughout this study. The correct identification of the trabecular broken region have a potential impact in the understanding of the structural mechanisms driving the mechanical fracture of bone, by the calculation of morphometric parameters in the actual broken region instead of the whole specimen.

References: 1. Goulet, R.W., et al., The relationship between the structural and orthogonal compressive properties of trabecular bone. J Biomech, 27(4): p. 375-89, 1994. 2. Helgason, B., et al., Mathematical relationships between bone density and mechanical properties: a literature review. Clin Biomech (Bristol, Avon), 23(2): p. 135-46, 2008. 3. Gibson, L.J., Biomechanics of cellular solids. J Biomech, 38(3): p. 377-99, 2005. 4. Perilli, E., et al., Dependence of mechanical compressive strength on local variations in microarchitecture in cancellous bone of proximal human femur. J Biomech, 41(2): p. 438-46, 2008. 5. Ohman, C., et al., Mechanical testing of cancellous bone from the femoral head: experimental errors due to off-axis measurements. J Biomech, 40(11): p. 2426-33, 2007. 6. Hulme, P.A., S.J. Ferguson, and S.K. Boyd, Determination of vertebral endplate deformation under load using micro-computed tomography. J Biomech, 41(1): p. 78-85, 2008. 7. Perilli, E., et al., MicroCT examination of human bone specimens: effects of polymethylmethacrylate embedding on structural parameters. J Microsc, 225(Pt 2): p. 192-200, 2007. 8. Ciarelli, T.E., et al., Variations in three-dimensional cancellous bone architecture of the proximal femur in female hip fractures and in controls. J Bone Miner Res, 15(1): p. 32-40, 2000. 9. Linde, F., I. Hvid, and F. Madsen, The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens. J Biomech, 25(4): p. 359-68, 1992. 10. Matsopoulos, G.K., Medical Image Registration and Fusion Techniques: A Review, in Advanced Signal Processing Handbook Theory and Implementation for Radar, Sonar, and Medical Imaging Real-Time Systems, S. Stergiopoulos, Editor. 2009, CRC Press, Taylor & Francis, Inc.: Florida. p. 148-221. 11. Matsopoulos, G.K., et al., CT-MRI automatic surface-based registration schemes combining global and local optimization techniques. Technol Health Care, 11(4): p. 219-32, 2003. 12. van den Elsen, P.A., E.J.D. Pol, and M.A. Viergever, Medical image matching-a review with classification. IEEE Engineering in Medicine and Biology Magazine, 12(1): p. 26-39, 1993.