HyQuest Solutions Pty Ltd INSTRUCTION MANUAL RAINFALL SENTRY MODEL RS3

Similar documents
OPERATING MANUAL CMC20A Current Meter Counter

HyQuest Solutions Pty Ltd. INSTRUCTION MANUAL FCD_App (TBRG FIELD CALIBRATION APPLICATION)

PTR4-SP Controller User Manual

INSTRUCTION MANUAL BUBBLER LEVEL SENSOR Model HS30V

INSTRUCTION MANUAL ABSOLUTE SHAFT ENCODER MODEL AD375MA

Basic User and Installation Manual

ph Meter & Controller Model: NANO-PCD1

CT1 Series 2. General Purpose Timer. Installation Manual 1 st Edition

Wireless Irrigation Control System

DUAL OUTLET CO2002 DIGITAL TAP TIMER INSTRUCTION MANUAL. CO2002 Dual Outlet Digital Tap Timer Instructions.indd 1

icon Series Controls

TR-3000 STORM WATER SAMPLER MANUAL OF OPERATION.

Micro-Master Touch Release Notes

WARNING. TTDJ Series Fully-Configurable Fault Annunciator Installation and Operations Manual

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor

Challenger Version 8 Programming Macro Logic.

2.4GHz Digital Wireless 7 LCD Surveillance Kit

Series B9 and C9 Electronic Metering Pumps. Instruction Manual. Manual No : 1796 Rev. : D Rev. Date : 11/2015

BIC 100 BERMAD Irrigation Control System

HyQuest Solutions Pty Ltd. INSTRUCTION MANUAL HS-HartBeat and HS-HartBeat Plus MODEL: HBT1 and HBT1 Plus

Digital 2.4GHz 3.5 LCD Monitor

SS2200 Remote Controller

Installation & Operation and Maintenance

Hydrological Services CMC20A OPERATING MANUAL CMC20A. Current Meter Counter

Instruction Manual. BMS CARD Model: DP-OPT-CARD-OP. Supplied by: - Retrofit to (or supplied with) DIGICHEM Plus + Controllers

Waste Water Collection System Wireless Monitoring Solutions

ABSOLUTE SHAFT ENCODER MODEL AD375MA INSTRUCTION MANUAL

WeatherMation LIVE Alerts and Notifications Module

Two Door Controller GEN-045

M2500 Engine Controller Configuration Manual

Operating Manual. A 1717 Message Player IMPORTANT NOTE: Redback Proudly Made In Australia

INSTALLATION & OPERATION

Control Indicator Module (CIM) - DNP3 Communications Protocol - TECHNICAL MANUAL

Low Power Modbus GPRS Data Logger

Mini Agg 1-10 (DC/AC)

x x 60 mm, 700 gm. Wall mounted enclosure, 1 Kg. Weatherproof, high impact GF ABS. Remote control and monitoring with debug features

Universal Trigger Box Users Guide

Reyrolle Protection Devices. 7SG117 Argus 7 Synchronising Relay. Answers for energy

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

P9 ASD Simple Start Guide

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

DATA ACQUISITION Hints and Tips

Product User Guide. OctProcessV2 and QuadProcessV2. QuadProcessV2-3A 4-Channel Low Level DC Current

AN004 Using the PMDX-126 s Error Input and Restart Output with Geckodrive Servo Drivers and Mach3 CNC Software

2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation

WHIRLYBIRD AUTOMATIC WEATHER STATION. Whirlybird Electronics Pvt Ltd 140, 2 nd Cross 13 th Main, BTM-I Bangalore

Product Data Sheet. BMS/Graphics Interface. Features

EA-EL 3000, EA-EL9000, EA-EL 9000 HP 400W W ELECTRONIC DC LOADS

Irrigation Control. Quick Start Guide Version 2c. Using Soil Moisture Sensors. Delta-T Devices Ltd

Colour Graphic Terminal User Manual. Rev 3.1

LED Wall Clock With Calendar and Temperature Display

Micro-Master 4500 Series Controllers

OPERATING MANUAL FOR SMIT-301MH STREAM SELECTOR

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

PEL-3031E Programmable D.C. Electronic Load

TS InteliSwitch Digital Time Switch 24VDC/VAC

Model: 8R5PR. 8 Channel RS485 Relay Xpander. Installation Manual. Product Revisions F/G

Setup Instructions. This manual is only valid for A12B Chargers equipped with the following: S2A-225C card with software version P225C0630

Bearing (Shock Pulse) Condition Analyzer -110

Mercury 11-10PV Pack / Condenser Controller Installation & User Guide V6 or Higher

DS-4483 Standard Logger Program Quick Reference For Software Version: 4.06

Each receiver has 4 switched outputs, which, using our one touch easy-learn process can be controlled from any switch on any compatible transmitter.

Challenger Series Administrators Manual

Cutout size : 138 X 138 mm 1

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

DPP601. Portable Programmer Installation Manual. contents

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

Data Transmitter 795. Data sheet

For more detailed instruction, see the KTA-282 user manual. This document is a condensed version; intended as a reference.

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS

Reyrolle Protection Devices. 7SG21 DDB20 Multi Range Digital Setting Time Delay Relay. Energy Management

Installation Instructions

Interface BL232 with RS232/422/485 MODBUS and 0-10V outputs. Interface BL232

PC180 USER MANUAL CHEMICAL MANAGEMENT SYSTEM

Touchpad User Guide. National Sales. Product Support. Freecall: Ph:

629/P32 (X10/P32) PIC CHIP. On - Off Operating Instructions (Revision 2)

Table of Contents. Technical Characteristics. Technical Characteristics 5. Parameters 7. User Interface 9. Installation 15. Product Selection 19

RAIN GAUGE TIPPING BUCKET TYPE

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Instruction Manual. For file reference, please record the following data:

EZY SWITCH. SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above

Micro Instruments price list All pricing excludes 15%

FCU-4 FAN COIL CONTROLLER

BB5-Lite TECHNICAL MANUAL

ENVIRORANGER ERS 500 NVIRORANGER ERS 500 USER GUIDE. Instruction Manual PL-600 January Rev. 1.2

Operating Instructions CHARGERY 440B V1.0

The IRC-Setup Software allows you to set the variables of the infrared sensors made by ALCAPLAST.

SEQUENCER FOR DEDUSTING PLANTS

Signet 5700 ph/orp Monitor - ORP Instructions

INSTALLATION PROCEDURE FOR THE INNOVEC IPT POWERED PRINTING TOTALISOR

PROFESSIONAL WIRELESS WEATHER STATION. Operation Manual - 1 -

Touchpad User Guide (Model: C-LCD-122-TL)

EGCP-2. Application Note (Revision NEW, 4/2003) Original Instructions

Water Distribution System Wireless Monitoring Solutions

SE-win User Instructions

TECHNICAL MANUAL FOR THE SHAFTENCODER PROGRAMMING TOOL

Modbus. Serial communication and control of Rotork actuators. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

Isolation Verification Control Mining - Marine - Transit Solutions LIVE Distributed By Locksafe Industrial Safety Equipment

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

DPR-34+ GB Revision 2

Transcription:

INSTRUCTION MANUAL RAINFALL SENTRY MODEL RS3 QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD 48-50 Scrivener St, Warwick Farm, NSW 2170, AUSTRALIA Phone: +61 2 9601 2022 Fax: +61 2 9602 6971 Email: sales@hyquestsolutions.com.au Web: www.hyquestsolutions.com.au 1

TABLE OF CONTENTS 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. INSTALLATION... 4 4. CONFIGURING / OPERATION... 5 2

1. INTRODUCTION The HyQuest Solutions Rainfall Sentry model RS3 is a low power, microprocessor controlled device designed to monitor rainfall and operate external pumps and/or solenoid valves to control the discharge of storm water into a sewage system. It detects pulses from a Tipping Bucket Rain Gauge, and when a set number of tips have been detected within a selected time period, a relay is operated to control a pump. Another settable timer determines how long the relay is held on for. If pulses from the TBRG are detected while the relay is activated, then the relay hold timer is restarted. 2. SPECIFICATIONS Programmable Settings: Tipping bucket size (0.2mm, 0.5mm, 1.0mm, 0.01 ) Rainfall required to trigger operation (1mm to 20mm) (0.01 to 0.5 ) Rainfall Period (1hr to 24 hrs) Relay hold time (1hr to 24 hrs) Power Requirements: Input: 6V DC (to power internal relay only) Tipping Bucket Rain Gauge (TBRG) Output Relay: 2 x Voltage Free contacts rated at 30V DC 0.5A 3

3. INSTALLATION *** Please Note *** The RS3 must be powered by a 6V DC supply. The relay contact outputs are voltage free and rated at 30V DC 0.5A. If operating a mains powered pump, the user must supply a separate slave relay/contactor. The RS3 does not have an IP rating, so a weatherproof enclosure may be required. 4

4. CONFIGURING / OPERATION There are 8 LCD screens available for status and configuring the RS3. The screens can be stepped through by pressing the Scroll button. The Select button is used to change a configurable option (display flashes) then press Scroll to change the option and press Select again to save the selection and stop the option flashing. Press any button to switch on the LCD screen. The LCD will turn off automatically after 15 seconds. LCD Display RSentry3 Rev 1.1 Battery OK 0.2mm 00:15 Reset No Bucket 0.2mm RainTrip 1.6 mm RainTime 1 hr HoldTime 1 hr Description Displays the model and software revision Displays the internal 3.6V lithium battery condition as OK or Low (This battery powers the clock/timer) Replace the battery when Low Displays the rainfall in the last hh:mm if triggered, then it displays Trig d if retriggered by further bucket tips then it displays Retrig d Allows the operation to be reset. (same as powering the unit off then on) Press Select to change the No to a Yes Displays the TBRG bucket size as 0.2mm / 0.5mm / 1.0mm / 0.01in Press Select to change the bucket size to match your TBRG Displays the amount of rainfall required to trip the relay. Press Select to change the rainfall required. (1.0mm to 20.0mm) or (0.01in to 0.50in) Displays the period of time in which to measure the rainfall to trip the relay. Press Select to change the time period. (1hr to 24 hrs) Displays the period of time the relay will be closed for. Press Select to change the time period. (1hr to 24 hrs) If the RainTrip amount of rain falls within the RainTime period, then the relay will be triggered. After the relay is triggered and the HoldTime timer starts, any extra bucket tip detected will restart the HoldTime timer that keeps the relay activated. The operation can be Reset at any time by scrolling to the Reset menu and selecting Yes. The operation is shown diagrammatically on the following page. 5

This example has the following setup : Bucket is set to say 0.2mm RainTrip is set to say 1.0mm RainTime period is set to say 1 hr HoldTime is set to say 3 hrs which means 5 bucket tips in 1 hour will trip the relay operation, and a bucket tip within the next 3 hours will restart the relay timer. Relay State Off HoldTime period On Tips RainTime period Timer starts when the first tip occurs Timer expired and did not have 5 tips in period Timer starts again 5 tips within the timer period so relay turns on. Timer starts again for each bucket tip while relay is on. HoldTime period expired since no more tips occurred. Sequence starts again when the first tip occurs When a rain gauge tip input is detected, the timer is started. If no further tips occur within the timer period then the unit re-enters the reset state. If however, the selected number of tips occur within the time period then the relay is turned on. Once the relay is operated, each tip will restart the timer, whilst maintaining the on state of the relay. If no further tips occur and the timer expires, the relay is turned off and the timer enters the reset state. 6