Introducing Server Technology s PRO1 Rack Power Distribution Unit

Similar documents
Sentry Power Manager (SPM): Hub and Node Feature Part Numbers SPM-Hub and SPM-Node

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

Sentry Power Manager (SPM) Software Security

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features

Zero Touch Provisioning (ZTP)

Using StartUp Stick for CDU Mass Configuration Part Number: KIT-SUS-01

Sentry Power Manager (SPM)

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.

Server Technology Technical Data Sheet

Models. Specifications

Sentry Power Manager (SPM)

Sentry Metered, Smart, and Switched High Density 30 Receptacle 208VAC, 3-Phase 30A Products

Sentry Power Manager (SPM)

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

Sentry Power Manager (SPM)

Intelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability

How do I... If you manage a datacenter, we have a solution for you.

Polar PDUs POWER MANAGEMENT

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00245, FEBRUARY 19, Release Notes Section Outline

Frequently Asked Questions

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00290, AUGUST 3, Release Notes Section Outline

PDU Solutions. PDU Solutions

Server Technology Inc.

Sentry Power Manager (SPM)

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

The -3Ph extension on a product indicates a 3 Phase power product.

IPDU-A Series User Manual. IPDU-A Series User Manual

SmartZone G5 Firmware Release Notes 2.2.2

PN5212/PN5320/PN7212/PN7320

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00109, SEPTEMBER 8, Release Notes Section Outline

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Power Distribution Unit

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

Power IQ DCIM Monitoring Version 6.2.1

Server Technology Inc.

Current Firmware Release Notes

Power Distribution. For technical support call Online catalog available at leviton.com 461

PDU Inspired by Your Data Center. W IEC PDU Series

Model# ANI SWH. Ver. 1.1

User Manual. Per Port Monitoring Models

AM-101 AM-101AirMedia Presentation Gateway. Supplemental Guide Crestron Electronics, Inc.

F. RELEASE NOTES for AP88xx Metered Rack PDU AP89xx Switched Rack PDU AP86xx Metered-by-Outlet with Switching Rack PDU

Basic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Power Distribution Units for Data Centers

Quickly place orders for your AT&T VPN inventory assets

Summit Virtual Chassis Design and Installation Guide

Solutions Guide for Cisco UCS B and C Series Servers

ipdu Pocket Guide INTERNATIONAL

ipdu Pocket Guide NORTH AMERICA

Fail-Safe Power Redundancy

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Table Of Contents. 1. Introduction... 1

Table of Contents SMARTZONE G5 USER MANUAL

Power Distribution Units for Data Centers

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

SNAP-IT-1U Installation Guide

How do I... Sentry Power Manager Rack-Level Data Center Power Monitoring & Management. If you manage a datacenter, we have a solution for you.

Mobile Apps Introduction Getting Started Features Resources

FUSION RX1600RAID. Rackmount 16-Drive SATA Storage System with Internal SAS Expanders. Drive Enclosure User s Guide

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

Intelligent Power Distribution

FUSION RX1600RAID. Rackmount 16-Drive SATA Storage System with Internal SAS Expanders. Drive Enclosure User s Guide

Using Server Technology Sentry Remote Power Managers with Avocent DSView 3 Management Software

Power Control and Distribution

Server Technology, Inc.

Power IQ DCIM Monitoring Version 6.2.2

APC Next Generation Rack ATS

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

Release Notes. Q-SYS Designer Release December 2017_Revision A

FUSION D800P2. Drive Enclosure User s Guide. 8-Drive Serial ATA Disk Array Storage System with Dual Port Multipliers. For Windows

8-Outlet eco PDU PE6208AV

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

Best Practices Guide. EMC VMAX3 Family. Best Practices Guide for AC Power Connections REVISION 2.0. August, 2015

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

Features and Benefits: Power IQ DCIM Monitoring Solutions

User Manual. (updated March 27, 2014) Information in this document is subject to change without notice.

Table of Contents SMARTZONE G5 USER MANUAL

Addonics T E C H N O L O G I E S

Safety Precautions Legrand PDU. 0U PDU Overview. Outlets. Circuits. Controller with Connector Ports: See Controller (on page 4).

Contents SMARTZONE G5 USER MANUAL

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

Rack PDU Marketing Playbook

IT Systems / Enterprise Storage Solutions EonStor A24F R2224

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

Copyright 2016 IPT PDUUM Revision

Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5. User s Guide. support.dell.com

FUSION 400. User s Guide. 4-Bay Serial ATA Hot-Swap Drive Enclosure. For Windows

ECO PDU Power Distribution Unit

RAMOS PLUS RACK MONITORING SYSTEM INTRODUCTION MANUAL

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5

FUSION D800RAID. Drive Enclosure User s Guide. 8-Drive Serial ATA Disk Array Storage System. For Windows

Eaton Open Data Centre Solutions. Kari Koli

Transcription:

Introducing Server Technology s PRO1 Rack Power Distribution Unit Purpose This technical note provides an introduction to the features of the PRO1 hardware and user interface. What is the PRO1? The PRO1 (Switched and Smart) is the latest design in Server Technology s reliable power distribution units (PDUs), providing flexibility for power management, cost savings, and advanced data center solutions. What s Unique About the PRO1? Server Technology s PRO1 design allows for PRO2 functionality in a CDU1 form factor. The PRO1 uses the Sentry4-MIB and the PRO2 firmware, version 8.0.x, allowing PRO1 products to offer the latest features and functions of the PRO2 product family. Equipment View of the PRO1 Unit Key Product Features of the PRO1 The PRO1 offers many features for power management, including: PIPS, (or TRMS), and (optionally) POPS high-accuracy measurements for current, voltage, power, and other key metrics. Single modular HDOT section with five available options. Auto-Flip LED display gives the proper display orientation no matter how the PRO1 is mounted in the cabinet. Outlet naming on all PRO1 products (for both Switched and Smart products). Hot-swappable network interface card (NIC) allows swapping the card in the field without causing a change in outlet state. The NIC can easily be replaced even when power is applied. Support for IPv6 address names and support for SNMPv3. Equipped for the mobile power monitoring solution using a Bluetooth module (for either Google Android or Apple ios), along with Server Technology s ST Eye mobile application. 303-9999-41 Rev A (090616) 1 OF 6

Several new levels of power monitoring for high-low warning-alarm thresholds and threshold hysteresis. If the master unit loses power, redundant power is provided to the master via the first linked unit, ensuring uptime. On-board firmware file system to allow direct GUI downloads of system files, firmware version updates, and MIB/OID tree files without using FTP. Intuitive and soft-mapped naming conventions used in both the PRO1 hardware and firmware to reflect the system hierarchy of units, cords, lines, phases, over-current protectors (OCPs), branches, outlets, outlet groups, and sensors. Server Technology s multi-linking technology that supports the optional linking of up to three expansion (link) units per one PRO1 master unit, allowing a single IP address for multiple cabinets. Feature Comparison: PRO1 vs. PRO2 The PRO1 is similar to the PRO2 in hardware architecture, object mapping, user interfaces (GUI and CLI), firmware (version 8.0.x or later), and new Sentry4-MIB, but the PRO1 does not include the following PRO2 items: Branch Current Monitoring feature TRMS Current Input Monitoring (in some cases rather than PIPS) The following table shows a detailed benefit comparison: Product PRO1 PRO2 Benefits CDU with NIM2/PRO2 Network Card: Faster processor and more memory Hot swap network card Network card swap with no re-programming (PCM) Features/functions can be added as needed Multi-linking (up to 4 units) Power from link unit keeps network up if power from master unit goes down Sentry4-MIB allows additional alarm warning and threshold levels PRO2 Architecture with NIM2 Network Card: PRO1 features, plus additional features PIPS standard Branch monitoring standard Locking data and low voltage cables Smart products with breaker/fuse branch circuit sensing All products 60 degrees Celsius rated 303-9999-41 Rev A (090616) 2 OF 6

PRO1 Hardware Architecture What s New? The new hardware design of PRO1 products reflects the many possible combinations of power data that can occur within a hierarchy of units, cords, lines, phases, over-current protectors (OCPs), branches, outlets, outlet groups, and sensors. The PRO1 firmware user interface (GUI and CLI) mirrors this fixed arrangement of system objects to support optimal monitoring and management of power metrics, and for user-configuration of PRO1 system values. System objects in the PRO1 hierarchy relate to each other in an overall fixed structure, top to bottom, as illustrated: Unit For the PRO1, unit is the physical enclosure. In the CDU1, this is tower. Cord For the PRO1, there is only one cord per a PRO1 unit. PRO1 lines/phases are part of the one cord. Line PRO1 data for individual lines includes current (A), thresholds, capacity, hysteresis, and more. Phase Data for each phase of a multi-phase line includes (phase) voltage and power factor. Over-Current Protectors (OCPs) Reports failed OCPs for Switched/Smart units. Outlets Configure multiple low/high warning/alarm threshold levels. Outlet Groups Assign outlets to named outlet groups. Sensors Set low/high temp/humidity thresholds. Using the PRO1 Firmware The PRO1 products use the same PRO2 firmware (version 8.0x or later), providing a similar GUI and Command Line Interface (CLI) as available with the PRO2 products. Note: Firmware, version 8.0, for the PRO1 product is not compatible with other Server Technology Rack Power Distribution Unit products. There is no upgrade path from earlier PDU products to PRO1 products. The PRO1 firmware provides the following key features: On-Board File System The firmware Web Interface provides an embedded file system to give quick access to system configuration files, as well as the on-board and downloadable Sentry4-MIB and OID Tree for the PRO1, eliminating website MIB/OID downloads. The page also allows GUI-based file uploads (without FTP) for system, configuration, and firmware versions. However, all PRO1 configuration/system files, MIB, and OID Tree can also be accessed via FTP/SFTP. Intuitive and Consistent Terminology The design of the firmware includes intuitive and soft-mapped naming conventions between the interfaces (Web and CLI) and the PRO1 product. For example, the firmware GUI areas (cords, lines, phases, over-current protectors, branches, outlets, sensors, etc.) match the same areas designed in the PRO1 hardware architecture. Outlet numbers are named 1-n sequentially and the outlet name is not tied to infeeds or branches. Input cords are also simply named 1-n sequentially (like 1-24), no longer 1-n for each phase (like XY 1-8, YZ 1-8, ZX 1-8). Also, firmware naming formats match the exact silkscreened names on the hardware unit. 303-9999-41 Rev A (090616) 3 OF 6

Outlet Grouping An outlet group is named group with a collection of PRO1 outlets assigned to the group. Outlet groups can be granted access to selected outlets by the administrative user (via the Web interface or CLI), and outlet activity by group can be monitored on a separate Web interface page for outlet group monitoring. Setting Thresholds When setting threshold values, the PRO1 firmware allows expanded alerting capabilities. Threshold values can be set by the administrative-user for multiple low/high warning/alarm levels (and threshold hysteresis), as listed below in the following PRO1 areas. Every item shown in the following list for which a threshold can be set also has a corresponding Monitoring page for viewing the item s current threshold values and operational status. Cord power (low and high), cord apparent power (low and high), cord power factor (low), 3-phase out-of-balance (high). Line current (low and high). Outlet current (low and high), outlet power (low and high), outlet power factor (low). Phase voltage (low and high), phase power factor (low). Temperature sensor (low and high). Humidity sensor (low and high). Analog-to-Digital (ADC) sensor (low and high) if an EMCU is connected to the PRO1 unit. The User Interfaces The PRO1 product offers two built-in user interfaces: Web interface (GUI) accessed via HTTP-enabled Ethernet connections. Command Line Interface (CLI) for serial and Telnet connections. Both interfaces allow power monitoring of PIPS/POPS data points, temperature/humidity measurements, system/network configuration, outlet control, ST Eye Bluetooth connection, user account management, and numerous other operations for PRO1 units. Either interface can be used as preferred; most firmware operations can be performed on GUI screens or by CLI commands on the command line. When using either interface, the availability of firmware functions for your user login account depends on your current user access rights as granted by the system administrator. 303-9999-41 Rev A (090616) 4 OF 6

PRO1 Dashboard View The Overview > System page provides a fast and high-level view of the overall condition of the PRO1 unit. The subsystem status view shows the current operational state of individual PRO1 units, cords, lines, etc. The color-coded status icon for each area is hot-linked to the corresponding monitoring page to show the operating details behind the status, illustrated below: Summary of PRO1 User Interface Options Overview As described above, the Overview option (System page) provides monitoring of major PRO1 operational areas. The page displays a quick view of color-coded icons showing current status of the units, cords, branches, lines, phases, sensors. Click an icon for the related monitoring page to view the metrics behind the status. Also shows color-coded graphs for the operational status of line current and temperature/humidity sensor readings. Monitoring The Monitoring option provides viewing of dynamically updated metrics for the PRO2 operational areas that have the highest power impact on the unit and the data center. The design of the GUI monitoring pages follows the major areas in the hardware architecture of the PRO2, providing a separate and detailed page for the overall status of units, cords, lines, OCPs, branches, outlets, groups, and sensors. 303-9999-41 Rev A (090616) 5 OF 6

Control For Switched PRO1 products only: The Control option allows the issuing of control actions On, Off, and Reboot for all PRO2 individual outlets, global outlets, and named outlet groups. Outlet details are also available by individual outlet to provide the outlet s general identification, socket type, capacity, operational state, power factor, as well as color-coded graphs for current and power. Configuration The Configuration option allows administrative access to all options for setting PRO2 values. The pages are organized into three major areas of configuration: System (options for PRO1 hardware areas) Network (options for setting up network protocols) Access (options for local/remote user access and management) Additional PRO1 Resources For information about the specific PRO1 product models, visit the Server Technology website at www.servertech.com Contact Technical Support Experience Server Technology's FREE Technical Support Server Technology understands that there are often questions when installing and/or using a new product. Free Technical Support is provided from 8 a.m. to 5 p.m. PST, Monday through Friday. After-hours service is provided to ensure your requests are handled quickly no matter what time zone or country you are located in. Server Technology, Inc. 1040 Sandhill Drive Tel: 1-800-835-1515 Web: www.servertech.com Reno, Nevada 89521 USA Fax: 775-284-2065 Email: support@servertech.com Server Technology, the Globe logo, Sentry, Switched CDU, CDU, PRO2, PIPS, POPS, PDU Power Pivot, and StartUp Stick are trademarks of Server Technology, Inc., registered in the US. EZip is a trademark of Server Technology. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Server Technology, Inc. disclaims any proprietary interest in trademarks and trade names other than its own. 303-9999-41 Rev A (090616) 6 OF 6