Qualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001

Similar documents
NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling

Tarleton State University. Specifications

3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series

Copper Riser And Intrabuilding Cabling

3M Indoor Protected Building Entrance Terminal 4588V-QCS Series

Government of Prince Edward Island Structured Cabling Standards August 24, 2009

3M Indoor Protected Building Entrance Terminal 4788V-QCS Series

The six major components of a structured wiring system are:

LANmark Snap-In Toolless connector. screened, with rear cover CAT7 GG45 INSTALLATION GUIDE

NZQA unit standard version 3 Page 1 of 5. Demonstrate knowledge for telecommunications premises network cablers

SYSTIMAX 360 PATCHMAX Modular Panel Instructions

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

SECTION COMMON WORK RESULTS FOR COMMUNICATIONS

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

SYSTIMAX GigaSPEED Xpress Solution Design Guidelines

COMMON WORK RESULTS FOR COMMUNICATIONS

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Indoor Protected Entrance Terminal 4588 Series

ANSI/TIA/EIA-568-B Cabling Standard

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING

Fog machine PT Users Manual

USB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide

AT&T Switched Ethernet Service SM

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

1 Channel Strobe Controller ORDERCODE 40226

InsuLogix T Fiber Optic Probes and Extensions Installation Guide

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

SPEC SHEET. Multimode Patch Cords and Pigtails. Cable types. Description. Features. Fiber types

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

Cabling Solutions Data Center & Local Area Networks

2 Mesa Ethernet Dock User s Manual

Qualified Partner Programme QPP. Voice Integration Felice Guarna

3M Indoor Protected Building Entrance Terminal (IBET) 4688V Series

Telecommunications Structured Cabling Systems

USB 3.1 CAT6A/7 EXTENDER

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

TIA/EIA 568A Sub-system HORIZONTAL CABLING

The University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS

NZQA unit standard version 2 Page 1 of 5

MICHIGAN DEPARTMENT OF TRANSPORTATION

Installation manual plugs and connectors with screw connection (16/32 A)

KM-4800w. Installation Guide

Copper Cabling Standards

Installation Job Aid for Ethernet Routing Switch 3600 Series

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

Installation Job Aid for Ethernet Routing Switch 5900 Series

D-Pack 6 Classic ORDERCODE 50315

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

Appendix 1 to the R&Mfreenet Warranty Program

ADJUSTABLE FLOOR BOXES

Los Angeles Community College District Design Standards

FTP1 Single Channel LED DMX Driver

PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL

Flexoled FTP3HP RGB LED DMX Driver

Symbols Glossary Rev. 1 1 / 16

SUBCON 15 HD (High-density) D-Subminiature Connectors

CERTIFICATION PLUS SM

Next Generation Firewall

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

PANGEN SYSTEM WARRANTY. Warranty Guide

ANSI/TIA-568-C Cat 6A Field Test Specifications

Bonding and grounding NETCONNECT copper cabling systems

Fiber Management Tray (FMT) User Manual

Enphase S-Series Microinverter and Engage Cable Safety

ONE SD-LAN Wall Mount Splitter Housing (1LAN-SPLT C)

INDUSTRIAL TRAY CABLE PRODUCTS

Computer Network Design Guide Existing Systems 1 / 6

Appendix D. EMC Installation Guidelines. Safety Considerations. Ferrite Absorbers and P-Clips. General Product Philosophy

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

LED Slimline PAR RGBW 7x8W

Brooks Models MT3809G Metal Tube Variable Area Flowmeters HART Handheld DD Installation & Operation Manual

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

ANSI/TIA-568-C Cat 6 Field Test Specifications

SAVE THESE INSTRUCTIONS

Cat.8 Shielded Field Termination Plug Description

Peter Sharp RCDD IBI Group

CLS Atmosphere LED-panel

Description and Assembly Instructions

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station

Operating instructions. Speed monitor D / / 2014

A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

Operating instructions. Switching amplifier DN0210 DN / / 2015

Rack Installation Instructions

PCS88-90 (Black) PCS88-94 (Silver)

Model No. ET-JPF200BE

EC Series. Safety Guide

Great Western Painting Assured Equipment Grounding Conductor Program OR Ground Fault Circuit Interrupter (GFCI)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

SYSTIMAX 360 ipatch Network Manager Module Faceplate Instructions

E1135C PDU and Pod Upgrade Procedure

Ethernet Test Access Panel (ETAP) User Manual

Termination for 568A and 568B pin configurations.

Distribution Module Cat 5E Panels

M250 (M LL) Safety

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Transcription:

Qualified Partner Programme QPP Installation Practice Felice Guarna Wetzikon,

Why installation quality Product performance must be preserved by an accurate installation Long term warranty requires design integrity to assure performance during the whole operational life of the cabling. Standards cover installation practice. New cabling categories have performance very close to limit of the hardware; margin for errors do not exist anymore. Installation Practice / Page 2

EN 50174 It is recognised that the cabling Installer, operating a quality assurance system in accordance with EN/ISO 9000 series has a common approach to all installation projects Compliance with ISO 9000 is not required but suggested Consistent approach to cabling is the way to assure quality to customer Quality is the signature of the installer and manufacturer Quality comes from a structured and ordered approach to the work Installation Practice / Page 3

EN/ISO 9000 PLAN EXECUTE Quality means continuous improvement process Improvement is achieved with learning IMPROVE LEARN VERIFY Learning is changing as result of experience Experience is the way of capitalizing on errors Installation Practice / Page 4

The approach PLAN EXECUTE VERIFY SPECIFY REALIZE TEST Cabling installation is part of whole IT project IT project will specify cabling requirements Installation must be regulated by its specification Specifications should cover from planning to test Installation Practice / Page 5

Installation specification Agreed between customer, designer and installer Subset of I.T. project specification Covering all aspects of cabling Installers job from planning to consignment including contractual aspect and possibly maintenance. Installation Practice / Page 6

Planning Understand the PURPOSE Know all elements Outline working plan Verify it on site Document Installation Practice / Page 7

Logistic Parts procurement Receiving inspection Storing with relative operations Move to working area Installation Practice / Page 8

Safety Safety and legal have priority Safety is your and your people protection Safety precautions are not signs only Safety has people as subject to prevent them becoming victims Installation Practice / Page 9

Safety site premises Four categories of exposures are present during the installation: Mechanical Chemical Electrical Fire These exposures are related to the premises as well as cabling Installation Practice / Page 10

Safety cabling components R&M cabling components are SAFE, as material and performance LS0H Comply with most stringent European and American norms To be used for the specific purpose of cabling UL/CSA Installation Practice / Page 11

Safety electrical Protective earthing, grounding and bonding Analysis of the building Protective earthing evaluation Measurements and physical verification Bonding structure decision Based on protective earth evaluation decide which bonding structure to adopt for cabling design Installation Practice / Page 12

Safety optical Two main cause of exposures: Laser light Usage of protected components Installer practice Mechanical Skin abrasion/intrusion Usage of chemical Proper disposal of consumable/debris Installation Practice / Page 13

Quality assurance Certification All activities to guarantee that customers objective is met Involve components, building, people, contract, job, tools. Establish criteria for consignment Installation Practice / Page 14

Administration Continuous changes and relocations require perfect knowledge of network users Manual or automatic generation of network plans are the must for the IT administrator Methodology and naming convention to be consistent with customer building identification All cabling elements to be identified/located Installation Practice / Page 15

Testing Testing section to cover purpose, subject of testing, methodology and tools Inspection criteria definition Link certification, channel certification, limits to be synchronized with IT installation test and cabling producer Corrective action to be planned Installation Practice / Page 16

Maintenance Preventive maintenance Reactive maintenance Cabling components do not require maintenance To be covered as per customer request Installation Practice / Page 17

Installation practice Logistic Order Transport Store Execute Pull Terminate Consign Document Label Record cable route Attach test result Quality Inspect Test Installation Practice / Page 18

Installation During transportation do not expose cabling material to pressure, strokes, environmental agents which visibly give damage to packing Store in dry place, indoor and with original packing. Should this be removed, do not expose to sunlight. Bringing material from cold to hot place, maintain packing material and allow temperature to set and eventually moisture to dry-out. Installation Practice / Page 19

Installation Cable can be installed only once! Horizontal cable must be used only indoor. In dry room and away from corrosive chemicals. Horizontal cable is not supposed to be exposed to rodent animals. Installation temperature 0 C to 50 C Operating temperature -20 C to +60 C Installation Practice / Page 20

Installation Horizontal cable is not intended for carrying electrical power or sustain mechanical loads. Horizontal cable is supposed to maintain jacket as much as possible Horizontal cable is intended to be used according to specifications and applicable standards Installation Practice / Page 21

Installation Cable is not supposed to be pulled but to be laid down! However Cable pulling by: hand Pull continuously with same force Never exceed max. pulling force Do not kink Installation Practice / Page 22

Installation Cable pulling by: knot Never exceed Max pulling force (see data sheet or catalogue) Pull slowly, continuously and with same force Do not kink After pulling remove 1 m before knot 1 meter Installation Practice / Page 23

Installation Cable pulling by: tool Pull continuously with same force Never exceed max. pulling force (better using fused rods) Do not kink Force spread on large area Installation Practice / Page 24

Installation Backbone cables: Multipairs/ four pair Fibre optic Not pulled but possibly lowered Fixed at least every floor by straps or positive fastening Allow weight relief loop at every other floor Never install in elevator rooms or too close to power installation Never fill conduit for more than 70% Maintain fire barrier at each floor Installation Practice / Page 25

Installation Cable preparation Pull cable outside the wall or panel for a length of 20-25 cm Remove jacket for 10 cm by using cable stripper and caution not to damage insulation 40 mm 15 mm Cat.. 6 proposal to reduce by 50% Installation Practice / Page 26

Installation Cable preparation Prepare pairs in the sequence indicated on the module Trim pairs for a length not exceeding 40 mm: Leaving maylar tape and drain wire for FTP cable Removing all for other cables Be careful not to untwist and keeping coloured wire together with its white pair. 40 mm 15 mm Cat.. 6 proposal to reduce by 50% Installation Practice / Page 27

Installation Module termination is the operation that if completed in a wrong way destroys most of the electrical characteristic of the link R&Mfreenet jack has been design to facilitate the operation and to give as less opportunities for error as possible Before proceeding to copper cable termination, you must identify carefully the elements of the cable mainly on the screened ones: The foil and its conductive side The drain wire that is running along and in contact with the conductive side of the foil The braid in case of S-FTP or S-STP Installation Practice / Page 28

Installation Conductive part of foil is silver coloured, insulated is red or blue Mylar tape is of insulated material Drain wire runs between conductive part of foil and maylar tape R&Mfreenet jack bayonet must be inserted between drain wire and conductive part of foil (FTP) or between foil and braid (other screened cables) Installation Practice / Page 29

Mounting connection module 4xRJ45u/s 568 B 87 45 63 21 568 A 87 45 63 21 8 8 p4 7 7 4 4 5 5 p2 p1 6 6 3 3 2 2 p3 p4 p 1 p2 p3 1 1 Pin assignment Colour Code: 568 A Pin 1: green / white Pin 2: green Pin 3: orange / white Pin 6: orange Pin 5: blue / white Pin 4: blue Pin 7: brown / white Pin 8: brown Installation Practice / Page 30

Installation QUALITY Inspect What Criteria Test Link Certification Installation Practice / Page 31

Inspection What? the cable route for proper workmanship cable laying and pulling cable fixing and bending damaged caused at site property during cable pulling/fixing restoring fire barrier and safety/security installations cable complete and correct labelling Installation Practice / Page 32

Inspection Criteria Sample check of 5% all terminations on panel side Sample check of 5% of all terminations on the Terminal Outlet side If error is found, increase sample to 10% If additional errors are found during second pass check, then inspect 100% Installation Practice / Page 33

Inspection Criteria Check cable jacket removal < 40 mm for Cat 5e and < 20 mm for Cat 6 Check pair untwisting < 13 mm for Cat 5e and Cat 6 Cable bending radius < 8 times cable diameter Cable fastening (connector, panel, cable bundle) not too tight (cable should still move after fastening) FILL UP CHECK LIST!!!!!! Installation Practice / Page 34

Fastening cable to connector Fastening cable: Do not tighten too much to deform cable. Strap should be free to rotate with minimum force applied Strap lock to be placed underneath the connector cable plate (not as shown in the picture) Strap Strap lock Installation Practice / Page 35

Fastening cable to panel Fastening cable to panel: Do not tighten too much to deform cable. Strap should be free to rotate with minimum force applied Strap lock to be placed underneath the connector cable plate ( as shown in the picture). To do this, first lock the strap, then cut excess length, last rotate 180 with minimum force the strap. Installation Practice / Page 36

Fastening cable, bundling the cables Bundling Fastening and bundling: Do not tighten too much to deform cables. Strap should be free to rotate with minimum force applied Note large bending radius Fastening to Rack Installation Practice / Page 37

Inspection What? the cable termination for manufacturing instruction cable management inside the rack and outlet complete identification and labelling grounding as per design instructions and manufacturers recommendations Installation Practice / Page 38

Installation Labelling Labelling means identify by means of a naming convention all elements of the cabling. Naming convention may varies depending on: Customer special requirements Local rules Building planner So far only EIA/TIA regulated, ISO in process to include Identification must be positive, unique, containing to/from information Installation Practice / Page 39

Installation What to identify Pathways Backbone conduit Conduit Cable tray Handhole Maintenance hole Spaces Entrance facility Equipment room Service entrance Telecom. closet Work area Cables Horizontal cable Backbone cable Fibre cable Terminations Crossconnect Splice Jack Consolidation Transition Grounding Bonding conductor Grounding BusBar Telecom. grdn BusBar Telecom. main GBB Installation Practice / Page 40

Claim and problem reporting procedure Should any problem arise that need R&M attention, CLAIM FORM must be filled and sent to R&M Customer Support Warranty Claims must be mandatorily communicated through CLAIM FORM CLAIM FORM must be filled in any part Parts must be identified by Part Number and Lot code Installation Practice / Page 41

Cable Identification Part Number Picture shows: R35257 = Part Number Batch no. 0142 725345/1 = production date and production lot number Both are blue ink printed Batch Installation Practice / Page 42

Patch Cord Identification Product Code (Part Number) Picture shows: 791435 = Product code (product Part Number) Not required Batch no. 0051 760829 = Patch cable production identification Both are blue ink printed Batch no. Installation Practice / Page 43

Patch Cord Identification Mfg no. Picture shows: 205256 = Mfg number (Manufacturing number) Required This number identify patch cord assembly and testing and is blank ink marked Installation Practice / Page 44

Connector Identification Picture shows a connection module with red arrow pointing to: Product batch identification number Batch id. number Installation Practice / Page 45