Applications: Astronomy, Photometry, EL/PL Imaging, Luminescence & Fluorescence Imaging, and Bose-Einstein Condensate (BEC) Page 1 of 7 IMAGING GROUP

Similar documents
IMAGING GROUP x 1300 imaging array; 20mm x 20mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee

IMAGING GROUP x 2048 imaging array; 13.5mm x 13.5mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee

IMAGING GROUP. 512 x 512 imaging array; 24 mm x 24 mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee

PIXIS: 512 IMAGING GROUP

PyLoN: Applications: Astronomy, Chemiluminescence, Bioluminescence, Phosphor Imaging, Ultra-low light Imaging and Spectroscopy.

Minimizes reflection losses from UV - IR; Optional AR coatings & wedge windows are available.

PIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels

20 MHz/16-bit readout 61 fps rate at full-frame resolution. Use ROI/binning for hundreds of frames per second.

ProEM -HS:1024BX3 FEATURES BENEFITS

ProEM -HS:1KBX3-10µm

ProEM -HS:1024BX3 FEATURES BENEFITS

Quad-RO: 4320 X-RAY GROUP

Frequently Asked Questions: Princeton Instruments excelon TM CCD and EMCCD Cameras

SOPHIA 2048B. Datasheet ULTRA-LOW-LIGHT, LOW-NOISE UV / VIS CAMERAS LARGE-FORMAT CCD CAMERAS

NIRvana: 640ST. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection

Frequently Asked Questions: excelon Back Illuminated CCD/EMCCD Cameras

Easy integration into complex experimental setup

PI-MAX 4: 1024 x 256 SPECTROSCOPY GROUP

NIRvana: 640. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection

Video frame rates and higher to efficiently synchronize with high repetition rate lasers

Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.

FEATURES BENEFITS 1024 x 1024 Imaging Array High resolution imaging and spectroscopy

PI-MAX 4: 1024 x 256

PI-MAX 4: 1024i-RF. Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.

PI-MAX 4: 1024 EMB. Applications:

SOPHIA -XO 2048B SOPHIA -XO 4096B

DV887 (back illuminated)

PI-MTE3. Datasheet LARGE-FORMAT, IN-VACUUM CAMERAS. Direct detection of soft x-rays. Up to 4k x 4k sensor formats. Reads out as fast as 3 full fps

. Ideal for fast, shutterless imaging

SYNCERITY TM 1024 x 256

Revolutionary High-Speed Cameras for Spectroscopy

Specifications Summary. Active pixels 1024 x Pixel size (W x H) 13 µm x 13 µm. Active area pixel well depth (typical) 100,000 e -

Specifications Summary 1. Array Size (pixels) Pixel Well Depth (typical) 94,000 e - Dark Current 2. Read Noise 3

idus 401 Series Specifications Summary Active pixels 1024 x 127 Register well depth (typical) 1,000,000 e - Maximum spectra per sec 88

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Dark Current 2. Pixel Well Depth (typical) e e -

Specifications Summary. Active pixels 1024 x Pixel size (W x H) 13 µm x 13 µm. Active area pixel well depth

Back-illuminated scientific CMOS cameras. Datasheet

25.6 mm wide / 1600 pixel, 3 MHz Spectroscopy EMCCD. Specifications Summary 1. Output node well depth: Conventional mode Electron Multiplying mode

Specifications Summary. Active pixels 2048 x Active area pixel well depth 100,000 e - Maximum readout rate. Read noise 2.9 e - Maximum cooling

Wavelength (nm) Specifications Summary. Active pixels 512 x 512. Pixel size (W x H) 24 µm x 24 µm

Newton EMCCD. Specifications Summary 1. Output node well depth (typical) High Sensitivity mode Electron Multiplying mode

pco.1600 cooled digital 14 bit CCD camera system

Specifications Summary 3. Active pixels 2048 x Pixel size (W x H) 13.5 µm x 13.5 µm. Active area pixel well depth. Maximum readout rate

Specifications Summary 2

800 nm µm Spectroscopy InGaAs PDA. Specifications Summary. Active pixels 512 or Pixel well depth (typical)

Control & Interface Electronics. CCD Sensor

pco.1600 cooled digital 14 bit CCD camera system

TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE

ikon-xl 231 VERY LARGE AREA ASTRONOMY CCD P P P P CCD NEW

Specifications Summary 2

27 mm wide, 3 MHz Spectroscopy CCD. Spectroscopy at Pace. Specifications Summary 1. Register well depth:

27 mm wide, 3 MHz Spectroscopy CCD. Spectroscopy at Pace. Specifications Summary 1. Register well depth:

High resolution Low noise High dynamic range Unparalleled sensitivity. Vision At Its Best

600 nm µm Spectroscopy InGaAs PDA. Specifications Summary. Active pixels 512 or Pixel well depth (typical)

High Resolution BSI Scientific CMOS

4.2 Megapixel Scientific CMOS Camera

sensicam qe cooled digital 12bit CCD camera system

Neo scmos. Specifications Summary. Pixel size (W x H) 6.5 µm. Pixel well depth (typical) 30,000 e - Pixel readout rate (MHz) 560, 200

Neo scmos. Specifications Summary. Pixel size (W x H) 6.5 µm. Pixel well depth (typical) 25,000 e - Pixel readout rate (MHz) 560, 400, 200

TRiCAM APPLICATIONS KEY FEATURES. Time Resolved intensified CAMera. TRiCAM 13001A01 31/10/2013

ikon-xl 230 VERY LARGE AREA ASTRONOMY CCD P P P CCD NEW

Back Illuminated Scientific CMOS

Product Information Version 1.1. ZEISS Axiocam 702 mono Your 2.3 Megapixel Microscope Camera for Fast Low Light and Live Cell Imaging

26.6 x 3.3 mm / 1024 x 127 pixel Spectroscopy CCD. Specifications Summary 2. Active pixels 1024 x 127. Register well depth (typical) 1,000,000 e -

26.6 x 3.3 mm / 1024 x 127 pixel Spectroscopy CCD. Specifications Summary 2. Active pixels 1024 x 127. Register well depth (typical) 1,000,000 e -

SBIG Research Series STL-1001E, STL-1302E, STL-4020M, STL-6303E and STL-11000M Large Format CCD Cameras

Product Information Version 1.1. ZEISS Axiocam 503 mono Your Flexible and Sensitive 3 Megapixel Microscope Camera for Live Cell Imaging

STT-1603ME and STT-3200ME High QE Camera Systems

FEATURES. APPLICATIONS Machine Vision Embedded Instrumentation Motion Control Traffic Monitoring Security

UHP-M Ultra-High Power UV-Visible LED Light Source Fluorescence Microscopy Ver. 07

Coherent kev Supercontinuum for Broad Element-Specificity. Courtesy of Dr. Daniil Kartashov. Specifications Summary 2. Register well depth

Neo scmos. Specifications Summary 2. Pixel size (W x H) 6.5 µm. Pixel well depth (typical) 30,000 e - Pixel readout rate (MHz) 560, 200

LS-785 High Throughput Lens Spectrograph User Manual

DIGITAL MICROSCOPY CAMERAS

NOW MAC COMPATIBLE INFINITY D I G I T A L M I C R O S C O P Y C A M E R A S

Lt Megapixel High-Speed CMOS Camera with SuperSpeed USB 3.0

andor.com Scientific CMOS - Fast, sensitive, compact and light Features and Benefits Specifications Summary Ultra Sensitive Imaging Low Light Imaging

WinCamD-LCM 1" CMOS Beam Profiling Camera, SuperSpeed USB 3.0, * nm * model-dependent

UHP-M Ultra-High Power UV-Visible LED Light Source Fluorescence Microscopy Ver. 04

Confocal Raman Systems SPECTROSCOPY GROUP

5.5 Megapixel, -40ºC, 1 e- Noise Rolling and Global Shutter Scientific CMOS YEAR VACUUM WARRANTY. Specifications Summary 2. Pixel size (W x H) 6.

ixon Specifications Summary Active pixels 128 x 128 Active area pixel well depth 250,000 e - Gain register pixel well depth 800,000 e -

UV-NIR LASER BEAM PROFILER

Product Information Version 1.0. ZEISS Axiocam 506 mono Your High Resolution Microscope Camera for Live Cell Imaging Fast, Flexible, and Sensitive

LIFA KEY FEATURES APPLICATIONS. Fluorescence Lifetime Attachment LIFA 15001A02 16/03/2015

FIXED FOCAL LENGTH LENSES

ASI174 Manual. Revision 1.2 Nov, 2017

2.8 Megapixel GigE camera with Sony ICX674 CCD sensor

Prosilica GC 1380H. GigE Vision, Sony ICX285 EXview CCD sensor, auto-iris, 30 fps. Benefits and features: Options:

Chemlux Imager. Applications

below. AOTF Module / Optics R O B U ST. R E L I A B L E. A C C U R A T E AOTF Video Adapter (Series VA310) KEY FEATURES POTENTIAL APPLICATIONS

Prosilica GT Megapixel industrial camera with GigE Vision interface. Benefits and features: Options:

Eagle V. Models: EA4240-CL and EA4710-CL USER MANUAL

GigE Vision, Sony ICX625 CCD sensor, auto-iris, 15 fps

APPLICATIONS KEY FEATURES. High-speed intensified Camera Attachment

Product Specification Sapphire

Manta G-419 NIR. GigE camera with NIR optimized CMOSIS/ams CMV4000 CMOS sensor. Benefits and features: Options:

Product Specifications Q-4A180/CL

Dual Fiber SWIR Laser Doppler Vibrometer

scmos discover new ways of seeing andor.com Features and Benefits Scientific CMOS - Fast, sensitive, compact and light. Specifications Summary

Transcription:

Now Powered by LightField PIXIS: 124 The PIXIS: 124 series of cameras from Princeton Instruments (PI) are fully integrated, low noise cameras with 124 x 124 resolution designed for quantitative scientific imaging applications from UV to NIR. Based on PI s exclusive XP cooling technology, PIXIS are the only cameras that offer cooling down to -9 C, with an all-metal, hermetically sealed design and the industry s only lifetime vacuum guarantee. High QE and ultra low-noise electronics make the PIXIS: 124 series of cameras ideal for demanding, low light applications such as astronomy, Bose-Einstein Condensate (BEC), solar cell inspection, chemiluminescence and fluorescence imaging. The exclusive B_eXcelon and BR_eXcelon technologies of the PIXIS:124 deliver the highest sensitivity in the UV-NIR range while suppressing the etaloning that occurs in standard back illuminated CCDs. Dual speed operation at 1kHz or 2MHz enables these cameras to be used both for steady state as well as fast kinetics studies. FEATURE Back-illuminated, deep depletion CCD with excelon technology (BR_eXcelon) Back-illuminated, excelon technology (B_eXcelon) 124 x 124 imaging array, 13 mm x 13 mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee Deep cooling Single fused silica vacuum window Optional UV phosphor coatings TTL input and output, and shutter control Low noise electronics Dual digitizers Software selectable system gains Kinetics USB2. data interface LightField for 64-bit Windows 7 or WinSpec for 32-bit Windows PICAM/PVCAM software development kits (SDKs) BENEFITS Highest QE in the UV and NIR range; High QE in the NIR range; Eliminates etaloning Lower dark charge than back-illuminated deep depletion CCDs; Extremely low etaloning High spatial resolution Low noise, few defects, linear response No out-gassing (as in epoxy seals) which can compromise vacuum performance; Worry free operation Low dark noise allows detection of faint signals; CoolCUBE II, a compact room temperature coolant circulator, is available for vibration sensitive environments Minimizes reflection losses from UV to IR; No optical losses due to multiple optical surfaces; Optional AR coating and wedge windows available Enhances sensitivity throughout the UV to below 2 nm (not available for excelon cameras) External control and triggering Best performance for low light level applications Dual-speed digitization allows complete freedom to select between slow operation for low noise and highest SNR or fast operation for rapid image acquisition Flexibility to optimize signal-to-noise ratio and dynamic range Custom readout mode offers microsecond resolution Plug-and-play operation with desktops or laptops; Optional fiber optic interface for remote operation Powerful, yet easy-to-use software packages for acquisition, display and analysis; LightField offers cutting edge interface, direct to hard drive streaming, time stamping & more Universal programming interfaces for easy custom programming; Compatible with Windows XP/Vista/7 and Linux Applications: Astronomy, Photometry, EL/PL Imaging, Luminescence & Fluorescence Imaging, and Bose-Einstein Condensate (BEC) Page 1 of 7 PIXIS: 124 excelon Rev. N2

SPECIFICATIONS Features CCD Image Sensor Dark current @ -7 C (e-/p/sec) CCD UV coating CCD format Imaging area Lens mount Deepest cooling temperature Thermostating precision Cooling method Full well: ADC speed/bits Single pixel Output node System read noise @1 khz @2 MHz Vertical shift speed Non-linearity Software selectable gains Operating systems supported Data interface I/O signals Operating environment Certification Dimensions / Weight PIXIS: 124BR_eXcelon PIXIS: 124BR PIXIS: 124B_eXcelon PIXIS: 124B/BUV PIXIS: 124F Back-illuminated, deep depletion CCD with excelon technology. Highest QE in the UV and the NIR. No etaloning. Princeton Instruments proprietary CCD with excelon technology, grade 1, NIMO.2 (typical).7 (max) All specifications subject to change Optional UV coating (not needed for BUV version) 124 x 124 imaging pixels; 13 x 13 mm pixels; 1% fill factor 13.3 x 13.3 mm (optically centered) Adjustable C-mount with integral 25mm shutter; spectrometer adapter available -9 C typical; -7 C guaranteed, specified at ambient temperature of +2 C ±.5 C Thermoelectric air or liquid cooling (CoolCUBE II liquid circulator available) 1 ke- (typical), 6 ke- (min) 25 ke- (typical), 22 ke- (min) 1kHz/16-bit and 2MHz/16-bit 3. e- rms (typical), 5 e- rms (max) 9. e- rms (typical), 15 e- rms (max) < 3.2 msec/row to18 msec/row (programmable) <1% @ 1 khz 1, 2, 4 e-/adu (typical); available at all speeds Windows XP/7 (32-bit), Windows 7 (64-bit) and Linux USB2. (5m interface cable provided); Optional Fiberoptic interface is available for remote operation Two MCX connectors for programmable frame readout, shutter, trigger in +5 to +3 C non-condensing CE Back-illuminated, deep depletion CCD. High QE in the NIR and no etaloning. e2v CCD47-1 back-illuminated deep depletion, grade 1, NIMO.2 (typical).7 (max) Back-illuminated CCD with excelon technology. Highest QE in the visible and high QE in the NIR. Extremely low etaloning. 5x - 1x lower dark charge than the BR. Princeton Instruments proprietary CCD with excelon technology., grade 1, AIMO.4 (typical).1 (max) 16.59 cm (6.53") x 11.81 cm (4.65") x 11.38 cm (4.48") (L x W x H) / 2.27 kg (5 lbs) Frame Rate Binning Back-illuminated CCD. Highest sensitivity in the visible region. Special BUV version offers the highest sensivity in the UV region. e2v CCD47-1 back-illuminated, grade 1, AIMO.4 (typical).1 (max) @ 2 MHz Front-illuminated CCD. Affordable technology for moderate light level applications. No etaloning. e2v CCD47-1 front-illuminated, grade 1, AIMO.2 (typical).7 (max) Readout Time @ 1 khz 1 x 1.58 sec 1. sec 2 x 2.28 sec 2.8 sec 8 x 8.14 sec.85 sec Page 2 of 7 PIXIS: 124 excelon Rev. N2

qe DATA 1% 9% 8% 7% Quantum Efficiency (%) 6% 5% 4% 3% 2% 1% % 25 3 35 4 45 5 55 6 65 7 75 8 85 9 95 1 15 BR_eXcelon B_eXcelon BR B BUV F With optional UV coating (for non-excelon cameras only) NOTE: Graph shows typical Quantum Efficiency (QE) data measured at + 25 C. QE decreases at normal operating temperatures. For the best results for your application, please discuss the specific parameters of your experiment with your sales representative. Page 3 of 7 PIXIS: 124 excelon Rev. N2

vacuum window ar coatings 1 95 9 NOTE: Standard anti-reflection (AR) coatings shown. Custom AR coatings and wedge window options are also available. Please contact your local sales representative for more information. % Transmission 85 8 75 BBAR UV-AR VIS-AR NIR-AR Uncoated window 7 65 Vacuum Window Transmission Data 6 2 3 4 5 6 7 8 9 1 excelon Performance Back-illuminated Back-illuminated_eXcelon Data taken with white light source through a monochromator comparing etaloning performance of excelon vs. back-illuminated CCDs. Page 4 of 7 PIXIS: 124 excelon Rev. N2

excelon Performance QE Improvement (B_eXcelon vs. B) Etalon Oscillations (B_eXcelon vs. B) 14.15 12 QE Improvement (B_eXcelon -B) 1 8 6 4 2 Relative Amplitude.1.5 -.5 -.1 B_eXcelon B -2 -.15 6 65 7 75 8 85 9 95 1 15 11-4 35 45 55 65 75 85 95 15 B_eXcelon provides superior QE over the standard back illuminated ( B ) version in the UV-NIR range. NOTE: QE data @ + 25 C B_eXcelon provides significantly lower etaloning (unwanted fringes) compared to standard back illuminated ( B ) version. QE Improvement (BR_eXcelon vs. BR) Etalon Oscillations (BR_eXcelon vs. BR) 5.15 45 4.1 QE Improvement (BR_eXcelon - BR) 35 3 25 2 15 1 Relative Amplitude.5 -.5 BR_eXcelon BR 5 -.1-5 35 45 55 65 75 85 95 15 BR_eXcelon provides superior QE over standard back deep depletion ( BR ) version over most of the UV-NIR range. -.15 6 65 7 75 8 85 9 95 1 15 NOTE: QE data @ + 25 C BR_eXcelon provides significantly lower etaloning (unwanted fringes) compared to standard back deep depletion ( BR ) version. Page 5 of 7 PIXIS: 124 excelon Rev. N2

OUTLINE DRAWING PIXIS: 124 (air cooled) C-MOUNT THREAD 1. - 32 UNC 4.65 118.11.69 17.53 NOMINAL FOCAL DISTANCE ADJUSTABLE C-MOUNT LENS ADAPTOR 1.85 47.2.23.23.82 2.85.45 11.43.5 12.7 4.15 15.41 2.14 54.43.48 12.19 WINDOW LOCATION COOLING AIR EXHAUST COOLING AIR INTAKE 2.14 54.36 ADAPTOR LOCKING SCREW. 2 PER CAMERA ONCE LENS IS IN FOCUS LOCKING SCREW SHOULD BE TIGHTENED TO LOCK THE POSITION OF THE LENS 1.78 45.21.25 6.35.59 15.6 1/4-2 X.25 TAPPED HOLE 6.53 165.75 5.97 151.7 4.97 126.11 NOTES: 1. WEIGHT: 5 lbs / 2.27 kg 2. POWER DISSIPATION 8 WATTS AT FULL POWER. 3. AIRFLOW 24 CFM FAN CAPACITY AT FULL POWER. 4. INTERNAL 25MM SHUTTER. 5. M6 THREADED INSERT AVAILABLE FOR CAMERA MOUNTING 6. WINDOW THICKNESS.125" [3.17mm] Page 6 of 7 PIXIS: 124 excelon Rev. N2

OUTLINE DRAWING PIXIS: 124 (liquid cooled) 1.-32 UN STANDARD C-MOUNT THREAD COOLANT INLET/OUT QUICK DISCONNECT FITTINGS 1.851 47.2 2 MCX CONNECTORS.23.23 USB 2. CONNECTOR.821 2.85.45 11.43.5 12.7 2.14 54.4 2 PIN LEMO CONNECTOR SHUTTER 9 PIN DIN CONNECTOR POWER 1/4-2 UNC.69 17.5 CCD TO MOUNT SURFACE 4.35 11.5 5.2 132.1 6.53 165.7 1.78 45.21.25 6.35.593 15.6 1.56 39.6 NOTES: 1. 2. 3. 4. WEIGHT 5.5 lbs / 2.5 kg POWER DISSIPATION 11 WATTS AT FULL POWER INTERNAL 25MM SHUTTER OPTIONAL EXTERNAL WATER CIRCULATOR COOL CUBE II 7567-2 www.princetoninstruments.com info@princetoninstruments.com TOLL-FREE +1.877.474.2286 PHONE +1 69.587.9797 Visit the Princeton Instruments website to find a representative in your area. Page 7 of 7 PIXIS: 124 excelon Rev. N2