Optical Time Domain Reflectometer USER'S GUIDE

Similar documents
AOR500-P PON Optical Time Domain Reflectometer USER'S GUIDE

MT-7610 Optical Time Domain Reflectometer USER'S GUIDE

USER'S GUIDE. Optical Time Domain Reflectometer

PON Optical power meter USER'S GUIDE

Optical Power Meter MT-7603

AE3100 Series User Manual. Version 1.02

FlexScan OTDR With SmartAuto and LinkMap

CS260 Contractor Series OTDR

MT9085 Series. ACCESS Master. Quick User s Guide

PROLITE-50/51/52 OPTICAL REFLECTOMETER (OTDR)

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter

HCC-CW-201A. CWDM Analyzer. Operation Guide

INSTRUCTION MANUAL 920XC-20C 920XC-20M 920XC-30F 920XC-30P. Handheld OTDRs. Register this product at

RA3301Optical Multimeter

Mini OTDR MOT-700 USER MANUAL

FlexScan OTDR With SmartAuto and LinkMap

OFL250 OTDR. Quick Reference Guide. or +1 (800) , +1 (603)

PRO-5350 OPTICAL TIME DOMAIN REFLECTOR

Optical Power Meter With VFL. User Manual

PM-204A/B. Power Meter. Operation Guide

PM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL

OTDR Testing Quick Reference Guide

920XC Training. 920XC Handheld OTDR. Training Presentation VER 1.0

OFT-3 Optical Time Domain Reflectometer User's Guide

Optical CWDM Power Meter

OFT-CWDM SERIES. Operation Guide. Optical Time Domain Reflectometer (OTDR) with CWDM Wavelengths V

User Manual. Optical DWDM Power Meter ODPM-48

Operation Manual for OLS-1315 Optical Light Source

FlexScan FS200 OTDR With SmartAuto, FleXpress and LinkMap

SKF Thermal Camera TKTI 21 & 31

CS Contractor Series Live PON OTDR

OVR Optical Time Domain Reflectometer User's Guide

AQ1200A/AQ1200B/AQ1200C/ AQ1200E/AQ1205A/AQ1205E/ AQ1205F OTDR Multi Field Tester

FlexScan FS200 OTDR With SmartAuto, FleXpress and LinkMap Quick Reference Guide

OTR 500 OTDR USER S MANUAL

CONTENTS CHAPTER I: BEFORE USE I. BEFORE USE

TOM103. Optical Power Meter OPTICAL POWER METER

PM-100 SERIES. Operation Guide. Power Meter V

FTE-7500 OTDR USER S MANUAL

EVOBOOK 2. User s Manual.

Thunder Bolt Multi-Tester Operations Manual

C2000 POWER METER With Data Storage

Operation Manual for OPM-1315 Optical Power Meter

OPM-50 Optical Power Meter User s Manual

Revolution for the installation and servicing of optical network. mini-otdr AQ7250

5.6" Multi-function Monitor

palmotdr User s Manual

PM-212-SI3 Pocket Optical Power Meter INSTRUCTION MANUAL

Handheld Optical Power Meter. Model SSF-TKITP-400 OPTICAL POWER METER. Manual

Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved.

M200 Handheld OTDR User s Guide

DV 5470 User Manual Package Contents:

Table of Contents. Chapter 1. Safety Precautions Notice Chapter 2. Components and accessories Chapter 3. Camera components...

AF-OLK5A Series Fiber Optic Test kit

PPM-30 PON Power Meter. User s Manual. Shineway Technologies, Inc. All rights reserved.

User manual Model: VIU-800 Brand:

User Manual. Cobia Flex R/F. English - v2014.3a

User Manual. Cobia Flex R/F English - v2016.5a

User s Manual BeamPod User Manual

SLIMLINE DASH CAM Audio & Video Recorder

b. Time Setting c. Volume Setting d. Backlight Setting e. Sleep Setting f. Pin Setting g. Joystick Calibration...

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

Multi-functional Camera

TC-600 VDSL2 TESTER (VDSL2/DMM/TDR/OPM/VFL/CABLE TRACING)

FIBER. WP-TEST-FIBER-400 Optical Power Meter Owner s Manual

1.Installation 2.Channel 3. Setting 4.Service 5.Information

IMPORTANT SAFETY INSTRUCTIONS

Overview 1. Foreword 2. Warnings

M-Series OTDRs. User s Guide. (800) or (603)

FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities

AK-C6A In Car Dash Camera. Instruction Manual Model Ref: MM347

DH-PFM906 Integrated Mount Tester

Portable Document & Image Scanner. User s Manual

EOS-6000 Series Optical A/B Switch User Manual DC Version

QuiX Startup Kit Quick Start Guide

Datasheet: Fiber OneShot PRO Singlemode Fiber Distance and Fault Locator; Fiber QuickMap Multimode Fiber Distance and Fault Locator

VS-K20 Compact Camera Controller. User Manual English

RA3211 PON optical power meter

User s Manual. ASE-1019 ASE Light Source

Windows " Intel Apollo Lake N3350 Clamshell Laptop

Always there to help you. Register your product and get support at CVR600. Question? Contact Philips.

10.1 HD Memory View Instruction Manual

DRAG 2. Manual Instruction

TABLET PC. Quick Start Guide. Model: TVE100 I

AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE

LDM M LASER DISTANCE MEASURER

HawkEye 45T Display User Manual

OFL 200 Single-mode Optical Time Domain Reflectometer User s Guide

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL

IMPORTANT SAFETY INSTRUCTIONS Do not use the product before you have studied the Safety instructions and the User Manual.

Contents. Important Safety Notice. Your dash cam Introduction What's in the box

Warning! It will cause malfunction if the monitor is operating with unspecified power supply adaptor or incorrect power voltage. Do not expose this

+ + Swift F1+ is a way on future splicers.

1. PRECAUTIONS. Thank you for choosing RUIDE theodolite Disteo 23. Please read this manual carefully before use.

User s Manual. AQ7270 Series OTDR IM E. 9th Edition

CF3000 Dealer Diagnostic Tool Instruction Manual

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Transcription:

Optical Time Domain Reflectometer USER'S GUIDE

AVOD EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION AVOD EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION WARNING You are cautioned that changes or modifications not espressly approved in this document could void yout authority to operate this VISIBLE LASER RADIATION equipment. SEMICONDUCTOR LASER To reduce the risk of fire or electric shock,do not expose this Wavelength:635-650nm apparatus to rain or moisture. To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only. NOTE As the laser is harmful to the eyes, do not attempt to disassemble the cabinet. Precautions for Use Use batteries 1 INVISIBLE LASER RADIATION SEMICONDUCTOR LASER Wavelength:800-1700nm CLASS I LASER PRODUCT At the same time, can not use different style or different capacitance batteries. And only charge the rechargeable batteries. Avoiding condensation problems As much as possible, avoid sudden temperature changes. Do not attempt to use the drive immediately after moving it from a cold to a warm location, to raising the room temperature suddenly, as condensation may form with in the drive. If the temperature changes suddenly while using the drive, Stop using it and take out batteries for at least an hour. Storage When long time no use,must take out the batteries to avoid destroying the device.

Standard Lithium battery Power adapter Host(with TF card) Carrying bag USB cable 2

1 2 3 4 10 11 12 24 5 6 7 8 9 16 19 17 20 18 Description 23 21 22 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 USB interface TF(micro SD) card slot Power adapter socket Charge indicator Menu button Cursor select button File operation button OPM fast enter button VFL control button Zoom control button Full screen button Power button Cancel button Real-time measurement button Average measurement button Up button Right button Down button Left button Confirming button OTDR optic fiber connector VFL optic fiber connector Anti-dust cover LCD 3

On/off Optical Time Domain Reflectometer Button is used to turn on/off the device. Keep pressing it for 2 seconds to turn on device. Short press it again to turn off the device. Press SCAN button to start measuring. But user should modify 2012-01-01 WED 21:25 * CHARGE measurement setting by real MENU Marker File OPM VFL ESC requirement before test start. ENTER REAL SCAN A-B: ---.---Km --.--db --.--db/km Km/div No. Distance Loss Reflection db/km C.Loss File Info: 4

Measurement Interface 2012-01-01 WED 21:25 Date and time Power 2012-01-01 WED 21:25 There are 10x10 grids in waveform region. Horizontal grids mean distance, vertical grids 40.00 36.00 A:0.000Km 32.00 B:0.000Km 28.00 174622_0001.sor 174622_0001.sor File name mean db value. As shown in figure, each horizontal grid represents 0.2km, each 24.00 20.00 16.00 12.00 Waveform region vertical grid represents 4dB. 8.00 4.00 0.00 A-B: 000.000Km 00.00dB 00.00dB/Km 0.200Km/div No. Distance Loss Reflection db/km C.Loss 1/3 0.000 0.00-28.00 --.-- 0.00 Measure Info: 1550nm 2.0Km 10ns Events list A-B: 000.000Km 00.00dB 00.00dB/Km 0.200Km/div The distance and Attenuation between A and B cursor Every horizontal grid is 0.2Km Measure info Measurement setting info 5

Real-time and average measurement Real-time measurement can quickly judge basic faults of optical fiber. Press Optical Time Domain Reflectometer REAL button to start real-time measuring. During measuring, you can change CHARGE MENU Marker File OPM VFL ESC range, zoom in or zoom out. Press button again or esc button to REAL stop. The device will not analyses event after real-time measurement in default. Unless you turn on RT analyse in System settings, the device will analyse events according to the last refreshed waveform. Average measurement can judge the line condition more accurate. It can get a ENTER REAL better SNR and fits high requirement circuit. Press SCAN button to start. User can SCAN set measurement time from 5 second to 180 second. The device analyses events and generates event list automatically. Press button during measuring, device will stop measuring, analyses events and generates event list automatically. esc 6

Event list No. Dis. Loss Ref. db/km C.Loss 1/3 0.000 0.00-28.00 --.-- 0.00 Event List No. Dis. Loss Ref. db/km C.Loss 1/6 2/6 3/6 4/6 5/6 6/6 Event list on main interface 0.000 0.940 4.301 5.589 18.712 39.809 0.00 0.08 0.12 -.-- -0.05 -.-- -51.74-51.74-54.67 -.-- -41.03-46.02 -.-- 0.24 0.28 -.-- 0.22 0.21 0.00 0.26 1.18 -.-- 4.07 9.41 After measurement or open a waveform in memory, there is event list on the bottom of waveform interface. Press button to show the whole event list. Six types of events as followed: Optic fiber start Reflection event Attenuation event Mix event Gain event optic fiber ending ENTER Press Up or Down button to select an event which needs to be located by cursor on the waveform. Then press button ENTER Press key ENTER to locate the corresponding event. Event List to return to waveform interface. The cursor will stay on the position of the selected event. Press button to return to waveform interface. 7 ESC

Real-time measurement tips The device supports user to change measurement range during real-time Optical Time Domain Reflectometer measurement. Start Real-time measuring function and press Up or Down button to increase or decrease the range. And it also supports to change the cursor position and zoom in/out waveform in realtime, which means you can zoom in partial waveform while measuring to judge the network fault. CHARGE MENU Marker File OPM VFL ESC ENTER REAL SCAN 8

Marker Cusor selection and waveform zoom in/out This device has two cursors, A and B. 2012-01-01 WED 21:25 Optical Time Domain Reflectometer Default distance is 0m, activated cursor turned to bright red. Press 40.00 36.00 A:0.000Km 32.00 28.00 24.00 B:0.583Km * 20.00 button switch to another cursor. Press Left 16.00 12.00 or Right button to move cursor. Press Up or 8.00 4.00 CHARGE MENU Marker File OPM ENTER VFL ESC REAL Down button to previous or next event. You can calculate the distance and attenuation between two cursors. 0.00 A-B: 000.000Km 00.00dB 00.00dB/Km 0.200Km/div No. Distance Loss Reflection db/km C.Loss 1/3 0.000 0.00-28.00 --.-- 0.00 Measure Info: 1550nm 2.0Km 10ns SCAN Keep pressing, then press and Up/Down button to zoom in or out waveform vertically. Keep pressing, then press Left/Right button to zoom in or out horizontally. Press button to return to full screen display. Notice: the focus of zooming is the location of the activated cursor. 9

Press key MENU to switch the menu tag. Menu Optical Time Domain Reflectometer CHARGE MENU Marker File OPM VFL ESC File Measure Settings System Settings About Open... Format SD Card... File Measure Settings System Settings About System Settings Wavelength 1550 nm Scan Mode Manual Range File Measure 80 Settings System Km Settings About Pulse Width 10000 ns Auto Power Off 10min Average Time 120 s Auto Name On Splice Loss 0.05 db Language/ File Measure English Settings System Settings About Reflection Threshold 65.0 db brightness 60 End Threshold 2.0Firmware Version: db TEN1A20V35_MAIN_V1.2 Date 2013 11 02 Refractive Rate 1.46832 TEN1A20V35_ANALOG_V0.3 Time 21 : 57 Scatter Coefficient 52.1 db TEN1A20V35_TFT_V1.1 Length Unit Metric Firmware Version: SEN1A20V35_MAIN_V1.2.0 Factory Settings No Firmware Version: FEN1A20V35_MAIN_V1.x.0 Press key ENTER to edit settings. Firmware Version: A4B75978 Language: English There are four pages of menu which used to configure parameters. Under waveform interface, press MENU button to switch the four menus cyclically. The four menus are: 1. File menu ENTER REAL SCAN 2. Measure settings menu 3. System settings menu 4. About 10

Menu-File menu File Measure Settings System Settings About Open... Format SD Card... File Measure Settings System Settings About 20140615 20140617 20140618 2014-06-15 2014-06-17 2014-06-18 20140619 2014-06-19 20140622 2014-06-22 Warnning Press key MENU to switch to the menu tag. Enter File menu, there are two options, "open" and "formatting SD card". Select Are you sure to format the SD card? one option and press ENTER button to OK Cancel enter the corresponding operation. Attention: formatting SD card operation will delete all files and cannot recover, please be cautious. 11

Menu-File menu Select "open" option, there are folders. The folder name is the date of the file saved, which is generated automatically by system. Files measured in the same day will be stored in the same folder. Folder can only be delete, but not rename. And must delete all files before delete the folder. Press Up or Down button to select a folder and press button to open delete tip. Then press ENTER button to finish deleting, or press ESC or button to cancel.

Menu-File menu File Measure settings System settings About... 133210_0001.sor 133210_0002.sor 2014-06-18 2014-06-18 133210_0003.sor 133210_0004.sor File 2014-06-18 Measure Settings2014-06-18 System Settings About... 133210_0001.sor 133210_0002.sor Delete... 133210_0003.sor Rename... 133210_0004.sor File Info: 1550nm 370m 10ns 2014-06-18 2014-06-18 2014-06-18 2014-06-18 13 Select one folder to display all files inside. Press Up or Down button to select one file and press ENTER button to display it in main interface. The file information at the bottom is the file's main measurement setting. Press button can delete or rename the file. Filename can make up of 23 digits, alphabets and special symbols at most. The last four numbers_xxxx is generated by "Automatic naming"function. Shut down this function will not generate. File Info 1550nm 370m 10ns

Menu-File menu Save File Name: 140950 Caps back Save a b c d e f g 7 Rename 8 9 h i jfile Name: k l m n 4 5 6 140950 o p q r s t u 1 2 3 Caps back Save v w x y z. _ 0 # a b c d e f g 7 8 9 h i j k l m n 4 5 6 14 When finish measuring an optic fiber, press File button to enter storage interface. Default filename is hour/minute/second of first time storage. Press Up/Down/Left/Right button to select alphabets, digits and symbols on soft keyboard. You can input 23 alphabets at most. If "Automatic naming" is enabled, the filename will automatically generated with four digits. Without shutting down the device, the following stored file's name will o p q r s t u v w x y z. 1 2 3 _ 0 # automatically plus 1. The file format is.sor. On file recalling interface, press Right button can Modify filename, as the same operations above.

Menu-Measure settings File Measure Settings System Settings About Wavelength Scan Mode Range Pulse Width Average Time Splice Loss Reflection Threshold End Threshold Refractive Rate Scatter Coefficient 1550 Manual 40 1000 120 0.05 65.0 2.0 1.46832 52.1 nm Km ns s db db db db Measure settings menu is used to set relative measurement data, which the judgment of events list is based on. Wrong setting might leads to wrong or missing events. Wavelength---wavelength of laser. Scan mode---manual and auto mode. Under auto mode, it will match the distance, range and pulse width. Range---match with the length of measured optic fiber, usually over one level. Pulse width---set the pulse width of output laser. Usually, small pulse width can measure close event, large pulse width can measure remote distance, but enlarge event's blind area. Average time--- can set between 5 second and 180 second as average measurement time. Splice loss---treat as an event when the loss is higher than setting value. Reflection threshold---treat as an event when the reflection is higher than setting value. End threshold---treat as the end of optic fiber when the loss is higher than setting value. Refractive rate---represent the average refractive index of entire optic fiber. Scatter coefficient--- the intrinsic value of Rayleigh Scattering. 15

Menu-System settings File Measure Settings System Settings About System settings menu is used to set the device's basic functions. Auto Power Off Auto Name Optical Dectector RT Analyse Brightness Date Time Length Unit Factory Settings 10min On On Off 60 2013 11 02 21 : 57 Metric No Auto Power Off--- set time of automatic off or cancel this function. Auto Name---name automatically when file is saving, can cancel this function. Optical Detector --- detect whether there is signal in optic fiber or not before measuring. RT Analyse --- set whether analyses events after real-time measuring or not. Brightness--- adjust brightness of LCD. Press key ENTER to edit settings. Date--- set year, month, day. Time ---set hour, minute. Length unit --- default is metric units. Factory settings --- is used in resetting to default, and has no effect on The set time and stored data. 16

Menu- About File Measure Settings System Settings About This menu is version details about device's configuration of Firmware Version: TEN1A20V35_MAIN_V1.2 TEN1A20V35_ANALOG_V0.3 TEN1A20V35_TFT_V1.1 Firmware Version: SEN1A20V35_MAIN_V1.2.0 Firmware Version: FEN1A20V35_MAIN_V1.x.0 hardware and software. CPU number is used to generate upgrading code, which should inform distributor or factory before software upgrading. Firmware Version: A4B75978 Language: English 17

OPM function Optical Power Meter Press OPM button on device with OPM function to enter Power +00.00 000.00 dbm mw OPM measurement interface. Press button to start measuring. Press button to change the wavelength. The meter's six calibration wavelengths are: 850nm, 1300nm, 1310nm, ENTER 1490nm, 1550nm, 1625nm. Press key Down to change the wavelength. 1310 nm Press ESC button to quit OPM function. Press key Enter to start or to stop measure. On 18

VFL 40.00 2012-01-01 WED 21:25 36.00 A:0.000Km 32.00 B:0.000Km 28.00 24.00 20.00 * This device has VFL function, the output power is about 1nW. Press VFL button to control red laser on-flashing-off. When Laser is on, the prompt icon will occur at upper right corner. 16.00 12.00 8.00 4.00 0.00 A-B: 000.000Km 00.00dB 00.00dB/Km 0.200Km/div No. Distance Loss Reflection db/km C.Loss 1/3 0.000 0.00-28.00 --.-- 0.00 Measure Info; 1550nm 2.0Km 10ns VFL laser output connector 19

TF card and USB communication All measured waveforms are stored in TF card. Using mini USB cable can store data to PC. PC will show a new disk icon, data inside. According to filename, user can store or recall files. 2012-01-01 WED 21:25 40.00 36.00 A:0.000Km 32.00 B:0.000Km 28.00 * 24.00 20.00 16.00 12.00 8.00 4.00 0.00 A-B: 000.000Km 00.00dB 00.00dB/Km 0.200Km/div No. Distance Loss Reflection db/km C.Loss 1/3 0.000 0.00-28.00 --.-- 0.00 Measure Info: 1550nm 2.0Km 10ns 20

User upgrading File Measure Settings System Settings About When device needs upgrading, user does not need to send it Firmware Version: TEN1A20V35_MAIN_V1.2 TEN1A20V35_ANALOG_V0.3 TEN1A20V35_TFT_V1.1 Firmware Version: SEN1A20V35_MAIN_V1.2.0 Firmware Version: FEN1A20V35_MAIN_V1.x.0 Firmware Version: A4B75978 Optical Time Domain Reflectometer back to factory. Prepare materials before upgrading as followed: 1. CPU ID 2. TF(micro SD) card, capacity is less than 16GB Inform the CPU ID to distributor or factory, you can get upgrading Language: English firmware only for your device. Store the firmware to TF card through CHARGE computer. Insert TF card to device when it is power off. Press MENU Marker File OPM VFL MENU and SCAN button and hold them, then press ENTER ESC REAL SCAN button to turn on the device, upgrading is starting. You can delete upgrading file in TF card when finish upgrading. 21

Charging 40.00 24.00 20.00 16.00 12.00 8.00 4.00 2012-01-01 WED 21:25 36.00 A:0.000Km 32.00 B:0.000Km 28.00 * This device has lithium batteries inside, and can only use the power adapter from factory to charge it. Insert the adapter to device, and finish charging in 8-10 hours. Red charge indicator means charging, while green means finish. Optical Time Domain Reflectometer 0.00 A-B: 000.000Km 00.00dB 00.00dB/Km 0.200Km/div No. Distance Loss Reflection db/km C.Loss 1/3 0.000 0.00-28.00 --.-- 0.00 Measure Info: 1550nm 2.0Km 10ns CHARGE MENU Marker File OPM VFL ESC ENTER REAL SCAN 22

Detail parameters Dynamic range Optic fiber type Wavelength Optic fiber connector LCD Test range Pulse width Measurement time Attenuation blind area Event blind area Distance accuracy Data storage Communication connector VFL power power Battery lifetime Working temperature Storage temperature Relative humidity Weight Appearance size Type S: 22/24dB, Type A: 26/28dB, Type B: 30dB/32dB, Type C: 34dB/36dB SM optical fiber 1310nm 20nm,1550nm 20nm FC/PC (SC/PC Optional) 3.5 inch colour LCD TypeS:80Km TypeA:100Km Type B:120Km Type C:140Km 10ns~10us 5s~180s 8m 1.5m 1.25m Micro SD card, less than 16GB USB 1mW Special lithium battery packet Standby>15 hour, measurement>8 hour 0 ~-50-20 ~-70 <90% 0.75Kg 197mmx107mmx67mm 23

P/N40331 Rev.1023