User Guide. Westermo Teleindustri AB RedFox. Ethernet switch and router approved for railway usage.

Similar documents
User Guide. Westermo Teleindustri AB TD-29 DC. FSK-modem Multidrop 2-wire.

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

DDW-002-B1. EN Ethernet Broadband Bridge. User Guide Westermo Teleindustri AB. 10/100 BASE-TX LINK DC1 X1 X1 DC2

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

Viper-12A. 12 port Ethernet M12 switch. User Guide Westermo Teleindustri AB. ON USB X2 X3 RSTP FRNT CON V ON USB

Viper port Ethernet M12 switch. User Guide Westermo Teleindustri AB. X1 X5 X9 X6 X10 X7 X11 SRV 1 X2 X8 X12 DC X4

User Guide. Westermo Teleindustri AB Lynx DSS L105-S1/L205-S1. WeOS. Industrial Ethernet 5-port Device Server Switch.

User Guide. Westermo Teleindustri AB DDW-220 WOLVERINE SERIES DDW-220. Industrial Ethernet SHDSL extender.

User Guide. Westermo Teleindustri AB Lynx DSS L106-S2/L206-S2. WeOS. Industrial Ethernet 6-port Device Server Switch.

User Guide. Westermo Teleindustri AB DDW-226 WOLVERINE SERIES. WeOS. Industrial Ethernet SHDSL extender.

User Guide Westermo Teleindustri AB SDW-500. Industrial Ethernet 5-port Switch.

Viper 20A Series. 20 port Ethernet M12 switches. User Guide REV. C. Westermo Teleindustri AB. X9 X15 X16 X17 X10 X11

User Guide. Westermo Teleindustri AB 2004 REV.A SDW Industrial Ethernet 5-port Switch.

User Guide. Westermo Teleindustri AB DDW-120. Industrial Ethernet SHDSL Extender.

User Guide. Westermo Teleindustri AB Lynx DSS L108 / L208-F2G-S2. WeOS. Industrial Ethernet 8-port Device Server Switch.

User Guide. Westermo Teleindustri AB RV-07B. 19 rack system PS-20 Power card.

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

Lynx. Industrial Ethernet 10-port Switch L110 / L210. User Guide

Legacy Serial. Legacy Serial Redundant Ring Ethernet Extender DDW-222. High Speed Ethernet extension over copper. Configuration and diagnostics

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

Wolverine DDW DDW Industrial Ethernet Extender WeOS

User Guide Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

AD-01 M-BUS Adapter. Industrial adapter, M-bus, Repeater, Converter and zone controller.

User Guide. Westermo Teleindustri AB BRD-355. Industrial ADSL/VDSL Router.

User Guide. Westermo Teleindustri AB Lynx DSS. WeOS. Industrial Ethernet Device Server Switch.

User Guide. Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

RedFox Industrial Series

MCW-211-F1G-T1G. Industrial Ethernet Media Converter.

Industrial Routing Switch

Ethernet Extender with serial support DDW-226

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

ODW-622 Fibre Optic Modem

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

ODW-621 Fibre Optic Modem

Trackside Networks. Solutions for Railway and Trackside Applications. Robust Industrial Data Communications Made Easy

User Guide. Westermo Teleindustri AB DDW-220. Wolverine series DDW-220. Industrial Ethernet SHDSL extender.

MRD-405. Industrial M2M/4G Gateway/Router GSM / GPRS / EDGE / HSDPA / HSUPA / HSPA/ 4G LTE. User Guide Westermo Teleindustri AB

Output Voltage* (nom.)(adjustable)

Industrial Routing Switch

User Guide. Westermo Teleindustri AB MCW-211. Industrial Ethernet Media Converter.

Output Voltage* (nom.)(adjustable)

MC 11 EB-2 Power supply cabinet with external bus, AC version

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

User Guide Westermo Teleindustri AB. Lynx SERIES. Industrial Ethernet 8-port Switch.

Trackside Networks. Solutions for Railway and Trackside Applications. Robust Industrial Data Communications Made Easy

Support Services. Industrial Data Communications

Redundancy unit CP-A RU

Safety Standards. Model Number:

TN-5308 Quick Installation Guide

RTU500 series Data Sheet Power Supply CP-E 24/2.5

User Guide Westermo Teleindustri AB. Lynx SERIES. Industrial Ethernet 8-port Switch.

Universal Power Supplies

User Guide. Westermo Teleindustri AB 2006 EDW Serial Adapter.

FL MC 2000E (SM40) LC

EH-RIO IP67 Profibus-DP I/O modules

User Guide Westermo Teleindustri AB EDW-100. Serial Adapter.

Industrial Power Supplies

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Power supply CP-D 12/2.1 Primary switch mode power supply

Power supply CP-E 48/1.25 Primary switch mode power supply

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

PSC600-series DC/DC W

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

CPCI-PS24 24V-Power Supply

AO523 Analog Input Module

AI561 Analog Input Module

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Rhino PSM Power Supplies. Operating Instructions

Power supply CP-E 24/0.75 Primary switch mode power supply

MINI-PS AC/10-15DC/8

PTC-101-M12 Hardware Installation Guide

PMT. Model Number: CC Code PM 24V 200W 1 A Panel Mount Product Type T Enclosed L L Frame*

Power supply CP-E 24/10.0 Primary switch mode power supply

Safety Standards. Model Number: Unit Weight:

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

PHOENIX CONTACT - 07/2006

TU531, TU532 Terminal Unit

CompactBlock Guard I/O EtherNet/IP Safety Modules

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-AHD.22

Features and Benefits. Certifications

Electronic timer CT-ERD.12

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

RedFox Industrial Rack Series

AO561 Analog Output Module

Safety Standards. Model Number:

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Enclosed Power Supplies

Transcription:

User Guide 6641-2223 RedFox R A I L Westermo Teleindustri AB Ethernet switch and router approved for railway usage www.westermo.com

Software tools Related software tools are available in the folder software tools under technical support on the Westermo website. Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice. Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused. More information about Westermo can be found at the following Internet address: http://www.westermo.com 2 6641-2223

Safety!! Before installation: Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, recom mended fuse: 4 A slow. It must be possible to manually disconnect power. Ensure compliance to national installation regulations. This unit relies on convection heating. Make sure that it is installed so that the ambient temperature is within the specified temperature range, e.g. by avoiding obstruction of the airflow around the unit. Before mounting, using or removing this unit: Prevent access to hazardous voltage by disconnecting the unit from all power supply. WARNING Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply. Before powering-up, a protective earthing conductor must be connected to the protective earthing terminal and have a cross-sectional area of at least 1.5 mm². When this unit is operated at an ambient temperature above +55 C (+131 F), +55 C (+131 F), the External Surface of Equipment may exceed Touch Temperature Limit according to EN/IEC/UL 60950-1. To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfill the warranty obligations. This unit must not be operating with removed covers or lids. Do not attempt to disassemble the unit. There are not any user serviceable parts inside. Do not drop, knock or shake the unit. Rough handling above the specification may cause damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not expose the unit to any kind of liquids (rain, beverages, paint etc), unless all connectors and the ventilation membrane are sufficiently protected. Do not use or store the unit in dusty or dirty areas, unless all connectors and the ventilation membrane are sufficiently protected. Do not cover or bring mechanical force to the ventilation membrane on the back of the unit. If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support. Maintenance No maintenance is required, as long as the unit is used as intended within the specified conditions. 6641-2223 3

Agency approvals and standards compliance Type EMC Safety Approval / Compliance EN 50121-3-2, Railway applications EMC: Rolling stock Apparatus EN 50121-4, Railway signalling and telecommunications apparatus EN 55022, Emission IT equipment EN 55024, Immunity IT equipment EN 61000-6-1, Immunity residential environments EN 61000-6-2, Immunity industrial environments EN 61000-6-3, Emission residential, commercial and light-industrial environments EN 61000-6-4, Emission industrial environments EN 50155, Railway applications, Approval/Compliance EN 60950-1, IT equipment 4 6641-2223

Declaration of Conformity Westermo Teleindustri AB Declaration of Conformity The manufacturer Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Herewith declares that the product(s) Type of product Model Art no EN 50155 Backbone Routing Switch RFR-212-FB 3641-1640 is in conformity with the following EU directive(s). No Short name 2014/35/EU Electromagnetic Compatibility (EMC) 2014/30/EU Low Voltage Directive (LVD) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) References of standards applied for this EU declaration of conformity. No Title Issue EN 50121-3-2 Railway applications - Electromagnetic compatibility -- Rolling 2015 stock - Apparatus EN 50121-4 Railway applications Electromagnetic compatibility Emission 2015 and immunity of the signalling and telecommunications apparatus EN 55022 Information technology equipment Radio disturbance 2010 characteristics Limits and methods of measurement EN 55024 Information technology equipment Immunity characteristics 2010 Limits and methods of measurement EN 61000-6-1 Electromagnetic compatibility Immunity for residential 2007 environments EN 61000-6-2 Electromagnetic compatibility Immunity for industrial 2005 environments EN 61000-6-3 Electromagnetic compatibility Emission for residential environments 2007 +A1:2011 EN 61000-6-4 Electromagnetic compatibility Emission for industrial environments 2007 +A1:2011 EN 50581 Technical documentation for the assessment of electrical and 2012 electronic products with respect to the restriction of hazardous substances EN 60950-1 Information technology equipment -- Safety -- General requirements 2006 +A11:2009 +A1: 2010 +A12:2011 The last two digits of the year in which the CE marking was affixed: 16 Pierre Öberg Technical Manager 22 nd March 2016 Org.nr/ Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. identity number Registered office S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna Sweden Int+46 16428000 Int+46 16428001 6641-2223 5

Type tests and environmental conditions Electromagnetic Compatibility Phenomena Standard Description Test Levels ESD EN 61000-4-2 Enclosure contact ±6 kv discharge immunity Enclosure air discharge ±8 kv immunity RF field AM modulated EN 61000-4-3 Enclosure RF immunity 20 V/m, 80 2700 MHz 10 V/m, 2700 600 MHz Fast transients EN 61000-4-4 Signal port immunity ±2 kv Power port immunity ±2 kv Surges EN 61000-4-5 Power port immunity ±2 kv (L-E) ±1 kv (L-L) EN 50155:2001 Power port immunity ±8.4 kv (L-E) ±8.4 kv (L-L) Conducted RF immunity EN 61000-4-6 Signal port immunity 10 V/m, 0.15 80 MHz Power port immunity 10 V/m, 0.15 80 MHz Power frequency magnetic field EN 61000-4-8 Enclosure immunity 300 A/m, 0, 16.7, 50 Hz Pulsed magnetic field EN 61000-4-9 Enclosure immunity 300 A/m Voltage interruption EN 50155 Residual voltage 0% 10 ms Supply overvoltage and undervoltage EN 50155 Overvoltage 140% Residual voltage 60% 100 ms & 1000 ms 100 ms Radiated emission EN 55011 Limits: EN 50121-3-2 Enclosure measurement 40 dbµv/m QP 30 230 MHz 47 dbµv/m QP 230 1000 MHz 56 dbµv/m AVG 1000 3000 MHz 60 dbµv/m AVG 3000 6000 MHz Conducted emission EN 55011 Limits: EN 50121-3-2 Power port measurement 99 dbµv QP 0.15 5 MHz 93 dbµv QP 5 30 MHz Signal port measurement 99 dbµv QP 0.15 5 MHz 93 dbµv QP 5 30 MHz Environmental Temperature EN 60068-2-1 EN 60068-2-2 Operating 40 to +70 C ( 40 to +158 F) Storage & Transport 40 to +85 C ( 40 to +185 F) Humidity EN 60068-2-30 Operating 5 to 95% relative humidity Storage & Transport 5 to 95% relative humidity Altitude Operating 2 000 m / 70 kpa Reliability prediction (MTBF) MIL-HDBK- 217F Operating 305,000 hours Vibration IEC 60068-2-64 Operating Vertical 2.0 m/s² Transverse 2.0 m/s² Longit. 2.0 m/s² Non operating 11.4 m/s² Shock IEC 60068-2-27 Operating 10 g, 30 ms Half sine ±3 shocks IEEE 1478 Operating 20 g, 11 ms Saw tooth ±3 shocks Packaging Dimension W x H x D 175 x 100 x 144 mm Weight 2295 g Degree of protection IEC 529 Enclosure IP65 Cooling Convection Mounting Rear panel wall mounting 6 6641-2223

Description Functional description RFR-212-FB is a switch developed for rail on board and industrial applications, approved according to EN 50155. To meet the environmental requirements from rail and harsh industrial applications the switch is equipped with rugged M12 Ethernet connectors and full metal housing and it fulfills IP 65 ingress protection. The unique FRNT (Fast Recovery of Network Topology) technology is the fastest protocol on the market to re-configure a network in the event of any failure of a link or hardware. RFR-212-FB supports QoS (Quality of Service) with four priority queues and strict priority scheduling as well as HoL (Head of Line Blocking Prevention), in order to assure a deterministic behaviour of the network. In the event of power loss or other switch failure, the RFR-212-FB is equipped with dual by-pass relays which can maintain communication through the switch of dual backbone links. 6641-2223 7

Interface specifications Power Rated voltage Operating voltage Rated current (using Westermo USB plug) Inrush current Startup current (Power source capability) Polarity Redundant power input Isolation to Galvanic connection to Connection 24 to 110 VDC 16.8 to 143 VDC (14.4 to 154 VDC for 100 ms) 470 ma @ 24 VDC 130 ma @ 110 VDC 5 ma²s @ 24 VDC 79 ma²s @ 110 VDC 600 ma @ 24 VDC 250 ma @ 110 VDC Reverse polarity protected No All interfaces and chassis None M12 A-coded male Connector size 0.2 2.5 mm² (AWG 24 13) Shielded cable Shielded cable Miscellaneous Not required Not required M12 A-Coded Power Connector Position Direction Description 1 U+ Positive supply voltage 2 3 0 V 0 V 4 Housing Shield Chassis of product (ground) 2 1 3 4 8 6641-2223

Ethernet TX (both switch, router and coupler ports) Electrical specification IEEE std 802.3. 2000 Edition Data rate 10 Mbit/s or 100 Mbit/s, manual or auto Protocol Duplex Full or half, manual or auto Circuit type TNV-1 Transmission range 100 m (328 ft) Isolation to All interfaces and chassis Galvanic connection to None Connection M12 D-coded Shielded cable Yes Conductive housing Yes Miscellaneous FRNT reconfiguration time Typically below 20 ms Number of ports 12 M12 D-coded, 10/100Base-TX Position Direction Description 1 Out Transmit Data + 2 In Receive Data + 3 Out Transmit Data 4 In Receive Data Housing Shield Chassis of product (ground) 6641-2223 9

Configuration backup device Electrical specification USB Memory size 16 Mbyte Protocol USB v1.1 Connection M12 A-coded female (on switch side) Isolation to All interfaces, but not to chassis Shielded cable NA Miscellaneous USB / Configuration Pin number No 1 No 2 No 3 No 4 No 5 Signal DN VBUS NC DP GND The agency approvals and standards compliance of the RFR-212-FB are valid with the WESTERMO USB configuration plug 3641-0190 attached. Only WESTERMO USB plugs are allowed for use together with this product. 10 6641-2223

Location of Interface ports, LED's LED indicators USB / Configuration Ethernet LED indicators Earth connect LED indicators Power 6641-2223 11

LED indicators LED Status Description ON OFF Unit has no power. GREEN RED BLINK All OK, no alarm condition. FRNT OFF FRNT disabled. GREEN RED BLINK Alarm condition, or until unit has started up. (Alarm conditions are configurable, see ''WeOS Management Guide''). Location indicator ("Here I am!"). Activated when connected to IPConfig Tool, or upon request from Web or CLI. FRNT OK. FRNT Error. RSTP OFF RSTP disabled. GREEN BLINK Unit configured as FRNT Focal Point. RSTP enabled. Unit selected as RSTP root switch. USR 1 OFF (Configurable) VPN disabled. GREEN RED X1 to X12 OFF No Link. GREEN GREEN FLASH YELLOW (Configurable) Default: At least one VPN tunnel up and OK. (Configurable) Default: All VPN tunnels down. Link established. Data traffic indication. Port alarm and no link. Or if FRNT, RSTP or Link Aggregation mode, port is blocked. 12 6641-2223

By-Pass functionality The by-pass functionality in RFR-212-FB secures connection in case of power failure in one of the switches. If a switch has power loss an internal relay in RFR-212-FB will bypass the switch and bridge two Ethernet ports. By-pass interfaces In case of power failure X9 will be by-passed to X11 and X10 will be by-passed to X12. Internally the switch will bypass X9.1 X11.2 X9.2 X11.1 X9.3 X11.4 X9.4 X11.3 Connected to X10.1 X12.2 X10.2 X12.1 X10.3 X12.4 X10.4 X12.3 Note! When by-passing a switch, approximately 5 m (16.4 ft) of the transmission range (100 m, 328 ft) is consumed. As an example, if a network is intended to cope with a single car blackout scenario and that two RFR-212-FB in that case will be by-passed, the total cable distance through the blackout car to adjacent switches on each side of the blackout car, should not exceed 90 m. (295 ft) Normally, RFR-212-FB can handle longer distances, up to 150 m (492 ft), but this can not be guaranteed and has to be investigated case by case. Cable length data is valid for cat5e cable. X11 X9 X11 X9 X12 X12 X10 X10 Switch 1 Switch 2 Switch 3 6641-2223 13

Mounting There are four 6 mm bore holes intended for mounting the unit. The unit can be mounted vertical or horizontal. Use four M5 screws with 12 mm washer on a flat and stable surface. Connection of cables Recommended tightening torque for the M12 connectors: 0.6 Nm. Removal Disconnect all cables and unscrew the unit from the wall. Time For Replacement < 15 minutes. Cooling This unit relies on convection cooling. Make sure that it is installed so that the ambient temperature is within the specified temperature range, e.g. by avoiding obstruction of the airflow around the unit. 14 6641-2223

Dimensions Measurements are stated in millimeters. 22 ±1 11 ±1 175 ±1 164 ±1 142 ±1 100 ±1 56 ±0,5 28 ±0,5 M5 2,5 ±0,5 6,5-0 0,5(4x) 24,5 0 15,5 31 46,5 62 77,5 93 11,5 ±0,5 3 ±0,5 144,5 ±1,5 133,0 ±1,5 55,2 36,8 18,4 0 22,4 6641-2223 15

Getting Started This product runs Westermo Operating System (WeOS) which provides several management tools that can be used for configuration of the unit. IPConfig tool This is a custom Westermo tool used for discovery of attached Westermo units. Web Configuration of the unit using the web browser. CLI Configuration of the unit via the Command Line Interface. If the computer is located in the same subnet as the switch you can easily use a web browser to configure the unit. Within the web you can configure most of the available functions. For advanced network settings and more diagnostic information, please use the CLI. Detailed documentation is available in the chapter The Command Line Management Tool in the WeOS management guide. Factory default IP address: 192.168.2.200 Netmask: 255.255.255.0 Gateway: Disabled Note! If you are not sure about the subnet consult your network administrator. Configuration Configure the unit from a web browser The unit can easily be configured from a web browser. Open the link http://192.168.2.200 in your web browser, and you will be prompted with a Login screen, where the default settings for Username and Password are: Username: admin Password: westermo Once you have logged in, you can use the extensive integrated help function describing all configuration options. Two common task when configuring a new switch is to assign appropriate IP settings, and to change the password of the admin account. The password can be up to 64 characters long, and should consist of printable ASCII characters (ASCII 33-126); 'Space' is not a valid password character. Note! Version of IP Config tool must be 10.4 or higher. 16 6641-2223

Referring documents Type Description Document number Management Guide Westermo OS management guide 6101-3201 Factory reset It is possible to set the unit to factory default settings by using Ethernet M-12 cables. 1. Power off the switch and disconnect all Ethernet cables. 2. Connect the first Ethernet cable between Ethernet port X1 and Ethernet port X6. Then connect the second Ethernet cable between Ethernet port X2 and Ethernet port X5. The ports need to be connected directly by an Ethernet cable, i.e., not via a hub or switch. Use a straight cable not a cross-over cable when connecting the ports. 3. Power on the unit. 4. Wait for the unit to start up. Control that the ON LED is flashing red. The ON LED flashing indicates that the unit is now ready to be reset to factory default. You now have the choice to go ahead with the factory reset, or to skip factory reset and boot as normal. Go ahead with factory reset: Acknowledge that you wish to conduct the factory reset by unplugging one of the Ethernet cables. The ON LED will stop flashing. This initiates the factory reset process*, and the unit will restart with factory default settings. When the switch has booted up, the ON LED will show a green light, and is now ready to use. Skip the factory reset: To skip the factory reset process, just wait for approximately 30 seconds (after the ON LED starts flashing RED) without unplugging the Ethernet cables. The switch will conduct a normal boot with the existing settings. * Note Do not power off the unit while the factory reset process is in progress. 6641-2223 17

Westermo SE-640 40 Stora Sundby, Sweden Tel +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.com www.westermo.com Sales Units Westermo Data Communications China sales.cn@westermo.com www.cn.westermo.com France infos@westermo.fr www.westermo.fr Germany info@westermo.de www.westermo.de North America info@westermo.com www.westermo.com Singapore sales@westermo.com.sg www.westermo.com Sweden info.sverige@westermo.se www.westermo.se United Kingdom sales@westermo.co.uk www.westermo.co.uk Other Offices For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code REV.C 6641-2223 2016-05 Westermo Teleindustri AB, Sweden