tem SLIO Fieldbus slave modules w/o I/Os tem 500S tem 300S tem 100V Order number Figure Type IM 053CAN, CANopen slave IM 053DN, DeviceNet slave IM 053DP, PROFIBUS-DP slave IM 053EC, EtherCAT slave General information Note - Coming soon - Coming soon Features CANopen slave, 16 Rx und 16 Tx PDOs, DeviceNet slave, Group 2 only Device, PROFIBUS-DP slave (DP-V0, DP-V1), EtherCAT slave 2 SDOs, Poll only Device For max. 64 Periphery modules, PDO-Linking, 244 Byte input and PDO-Mapping: fix 244 Byte output data Technical data power supply Power supply (rated value) Power supply (permitted range) DC 20.4...28.8 V DC 20.4...28.8 V DC 20.4...28.8 V DC 20.4...28.8 V Reverse polarity protection - - - - Current consumption (no-load operation) - - - - Current consumption (rated value) 1.9 A 1.2 A 1.9 A 1.2 A Inrush current - - - - I²t - - - - Max. current drain at backplane bus 3 A 3 A 3 A 3 A Max. current drain load supply - - - - Power loss - - - - Status information, alarms, diagnostics Status display yes yes yes yes Interrupts yes, parameterizable - yes, parameterizable yes, parameterizable Process alarm no - yes, parameterizable yes, parameterizable Diagnostic interrupt yes, parameterizable - yes, parameterizable yes, parameterizable Diagnostic functions yes, parameterizable - yes, parameterizable yes, parameterizable Diagnostics information read-out possible - possible - Supply voltage display green LED green LED green LED green LED Group error display red SF LED red SF LED red SF LED red SF LED Channel error display none none none none Hardware config Racks, max. 1 1 1 1 Modules per rack, max. 64 64 64 64 Number of digital modules, max. 64 64 64 64 Number of analog modules, max. 64 64 64 64 Communication Field bus CANopen DeviceNet PROFIBUS-DP to EN 50170 EtherCat Type of interface CAN - RS485 isolated - 64
Fieldbus slave modules w/o I/Os Interface modules tem SLIO Order number Connector Sub-D, 9-pin, male 5-pin Open Style Connector Sub-D, 9-pin, female RJ45 Topology Linear bus with bus termination at both ends - Linear bus with bus termination at both ends Electrically isolated - - Number of participants, max. 127-125 65535 Node addresses 1-127 - 1-125 1-65535 Transmission speed, min. 10 kbit/s - 9.6 kbit/s - Transmission speed, max. 1 Mbit/s 500 kbit/s 12 Mbit/s 100 Mbit/s Address range inputs, max. 128 Byte 256 Byte 244 Byte 1 KB Address range outputs, max. 128 Byte 256 Byte 244 Byte 1 KB Number of TxPDOs, max. 16 - - - Number of RxPDOs, max. 16 - - - Mechanical data Dimensions (WxHxD) - Weight 155 g - 155 g - Environmental conditions Operating temperature 0 C to 60 C 0 C to 60 C 0 C to 60 C 0 C to 60 C Storage temperature -25 C to 70 C -25 C to 70 C -25 C to 70 C -25 C to 70 C Certifications UL508 certification in preparation in preparation in preparation in preparation tem 500S tem 300S tem 100V 65
1 2 3 4 5 6 7 8 tem SLIO Connections, Interfaces tem 500S tem 300S tem 100V CAN DP slave V- CL DR CH V+ GND CAN low Drain CAN high 66
Fieldbus slave modules w/o I/Os Interface modules Fieldbus slave modules w/o I/Os tem SLIO Order number Figure Type IM 053MT, Modbus/TCP slave IM 053PN, PROFINET-IO slave General information Note Coming soon Coming soon Features Modbus/TCP slave, PROFINET-IO slave I/O configuration via field bus, Adjustable I/O cycle (0,5...4 ms) Technical data power supply Power supply (rated value) Power supply (permitted range) DC 20.4...28.8 V DC 20.4...28.8 V Reverse polarity protection - - Current consumption (no-load operation) - - Current consumption (rated value) 1.2 A - Inrush current - - I²t - - Max. current drain at backplane bus 3 A 3 A Max. current drain load supply - - Power loss - - Status information, alarms, diagnostics Status display yes yes Interrupts - - Process alarm - - Diagnostic interrupt - - Diagnostic functions - - Diagnostics information read-out - - Supply voltage display green LED green LED Group error display red SF LED red SF LED Channel error display none none Hardware config Racks, max. - - Modules per rack, max. - - Number of digital modules, max. - - Number of analog modules, max. - - Communication Field bus Modbus / TCP/IP PROFINET-IO Type of interface - - Connector - - Topology - - Electrically isolated - - 67 tem 500S tem 300S tem 100V
tem SLIO tem 500S tem 300S tem 100V Order number Number of participants, max. - - Node addresses - - Transmission speed, min. 10 Mbit/s 10 Mbit/s Transmission speed, max. 100 Mbit/s 100 Mbit/s Address range inputs, max. 256 Byte 1 KB Address range outputs, max. 256 Byte 1 KB Number of TxPDOs, max. - - Number of RxPDOs, max. - - Mechanical data Dimensions (WxHxD) Weight - - Environmental conditions Operating temperature 0 C to 60 C 0 C to 60 C Storage temperature -25 C to 70 C -25 C to 70 C Certifications UL508 certification in preparation in preparation 68
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Fieldbus slave modules w/o I/Os Interface modules Connections, Interfaces tem SLIO Net tem 500S tem 300S tem 100V 69