Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Improvements in Openness 4. Readme. Readme

Similar documents
Readme SiVArc V14 SP1 Update 6

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 7 2. Improvements in Update 6 3. Improvements in Update 5 4

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 2 2. Improvements in Update 1 3

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 6 2. Improvements in Update 3 3. Improvements in Update 2 4

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

Optional package printer driver V1.4

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

PD PA AP How To Configure Maxum II TimeServer Access

SIMATIC HMI. WinCC V7.4 WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. TIA-Portal SIMATIC Visualization Architect. Security information 1. Basics 2. Installation 3. Elements and basic settings 4

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

SIMATIC. Process Control System PCS 7 Licenses and quantity structures (V8.0) Preface 1. Selecting the correct license keys 2

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

Web Option for OS (V8.0) SIMATIC. Process Control System PCS 7 Web Option for OS (V8.0) Preface 1. Additional documentation

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Security information 1. Preface 2. Additional documentation 3

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

SIMATIC HMI. WinCC V7.4 SP1 SIMATIC HMI WinCC V7.4 Getting Started. Welcome 1. Icons 2. Creating a project. Configure communication

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

SIMATIC. Process Control System PCS 7 Software update with utilization of new functions. Security information 1. Preface 2.

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

SIMATIC. Process Control System PCS 7 Symantec Endpoint Protection 11.0 Configuration. Using virus scanners 1. Configuration 2. Commissioning Manual

SIMATIC. PCS 7 Web Option for OS (V8.2) Security information 1. Preface 2. Overview of the Web Option for OS 3. Additional documentation 4

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

Siemens Drives & PLCs

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

Siemens Automation Products

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

SIMATIC NET. S TeleControl MSC300_Library program block library. Block library for TCSB (V3) WDC_S7_300_... (FB92) 2 UDT_WDC_PARAM (UDT91) 3

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

Block Library Motor Starter SIRIUS for SIMATIC PCS 7

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3.

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

SIMATIC HMI. WinCC V7.4 SP1 WinCC/Audit. WinCC/Audit - Installation Notes 1. WinCC/Audit - Release Notes 2. WinCC/Audit - Documentation.

Examples for SIMATIC IPC Support. Package for VxWorks SIMATIC. Industrial PC Examples for SIMATIC IPC Support Package for VxWorks

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

SIMATIC HMI. WinCC V7.4. WinCC/Calendar Options. Calendar Options overview 1. WinCC/Calendar Options. Installation Notes 2

COMOS. Lifecycle COMOS Walkinside Getting Started. Security information 1. Which functionalities are not covered in this manual? 2

Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET

Scope and Purpose of this. Guideline. Requirements. Limitations. MindSphere. Testing. MindConnect LIB Developer. Branding.

SIMATIC HMI. WinCC V7.0 SP1 MDM - WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2.


Configuration limits for products of the HARDNET-PB DP-Base 1

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

B.Data V6.0 Installation SIMATIC. B.Data V6.0 Installation. Introduction. Installing B.Data. Setting up B.Data Web 3

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

Parameter 1. Faults and alarms 2 SIMOCRANE. Truck Positioning System (TPS) Parameter Manual. applies to SIMOCRANE TPS Version 1.1

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information.

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

SIMATIC. PCS 7 Process Control System CFC Readme V9.0 SP2 Upd2 (Online) Security information 1. Overview 2. Notes on Installation 3.

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Settings. Prior information notice 1. Introduction to "Settings" 2. User rights in "Settings" 3. Settings interface 4.

Sample project Filling Station SIMATIC. STEP 7 Professional / WinCC Advanced V11 for Sample project Filling Station. Overview of the Getting.

SIMATIC. Process control system PCS 7 PCS 7 - PC Configuration (V9.0 SP1) Security information 1. Preface 2. PC components of a PCS 7 system 3

SIMATIC HMI. WinCC WinCC Runtime Advanced readme. Security information 1. Installation 2. Runtime 3. System Manual. Online help printout

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

COMOS. Lifecycle 3D Integration Operation. Publisher 1. COMOS PDMS Integration 2. Material management 3. COMOS 3D viewing 4.

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3

SIMATIC. Process Historian 2014 SP2 SIMATIC Process Historian. Process Historian - Installation Notes 1. Process Historian - Release Notes

SIMATIC. STEP 7 (TIA Portal) Global library "Sample Library for Instructions" Disclaimer. Basic information on the library.

Transcription:

Validity 1 Improvements in STEP 7 2 SIMATIC Improvements in WinCC 3 Improvements in Openness 4 6/2018

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Digital Factory Postfach 48 48 90026 NÜRNBERG GERMANY P 07/2018 Subject to change Copyright Siemens AG 2018. All rights reserved

Table of contents 1 Validity...5 2 Improvements in STEP 7...7 2.1 Improvements in Update 3...7 2.2 Improvements in Update 2...7 2.3 Improvements in Update 1...8 3 Improvements in WinCC...11 3.1 Engineering system...11 3.1.1 Improvements in Update 3...11 3.1.2 Improvements in Update 2...11 3.2 Panels...12 3.2.1 Improvements in Update 3...12 3.2.2 Improvements in Update 2...12 3.2.3 Improvements in Update 1...13 3.3 Runtime Advanced...13 3.3.1 Improvements in Update 1...13 3.4 Runtime Professional...13 3.4.1 Improvements in Update 3...13 3.4.2 Improvements in Update 2...14 3.4.3 Improvements in Update 1...14 4 Improvements in Openness...17 4.1 Improvements in Update 1...17, 6/2018 3

Table of contents 4, 6/2018

Validity 1 Validity This update is valid for the following products: STEP 7 Basic V15 STEP 7 Professional V15 WinCC Basic V15 WinCC Comfort V15 WinCC Advanced V15 WinCC Professional V15 TIA Portal Openness V15 Note If you modify your system after installing the update with the product DVD, you will have to perform the update again. Windows 7 and Windows Server 2008 R2: Invalid certificate validation The new certificates used for signing may possibly not be validated on the Windows 7 and Windows Server 2008 R2 operating systems. If you do not have the possibility to update the certificate store online, the signature of the product files is displayed as invalid. In this case, update the root certificates provided by Microsoft on the offline systems. To do so, follow the instructions in FAQ 109748887 (https:// support.industry.siemens.com/cs/ww/en/view/109748887). Note for installation under Windows 7 The TIA Portal can only be run on Windows systems that support the secure hash algorithm "SHA-2". "SHA-2" is only supported under Windows 7 once a security update has been installed (KB 3033929). Therefore, make sure that the latest Windows security updates are installed on your system., 6/2018 5

Validity 6, 6/2018

Improvements in STEP 7 2 2.1 Improvements in Update 3 Update 3 contains the following improvements and changes: Working with the TIA Portal Stability when working with the TIA Portal has been improved, partly based on the feedback from returned crash reports. 2.2 Improvements in Update 2 Update 2 contains the following improvements and changes: Working with the TIA Portal Stability when working with the TIA Portal has been improved, partly based on the feedback from returned crash reports. Non-typified notation for time constants In V15 the program editor does not accept the non-typified input of time constants. Time constants must always be entered in typified notation (for example, t#500ms, t#0.5s). This behavior is corrected with V15 Update 2. Non-typified constants (such as 500ms, 0.5s) are now again accepted for the following data types: Date, TOD, LTOD, S5Time, Time, LTime, LDT. Zones for 2D kinematics (S7-1500T) When using the motion control instructions "MC_DefineWorkspaceZone" and "MC_DefineKinematicsZone" to define zones for 2D kinematics and 2D kinematics with orientation, only the value 0.0 is permitted at the "Frame.y", "Frame.a", and "Frame.c" parameters with the firmware version V2.5. The ErrorID 16#80C4 (invalid frame) is displayed for values other than 0.0. This behavior is corrected with firmware version V2.5.2. Jogging or positioning the orientation axis A4 with the Kinematics control panel (S7-1500T) With firmware version V2.5, you can only position orientation axis A4 in the world coordinate system (WCS) with the operating mode "Jog to target position" on the Kinematics control panel. This behavior is corrected with firmware version V2.5.2., 6/2018 7

Improvements in STEP 7 2.3 Improvements in Update 1 Extended Motion Control Resources (S7-1500T) If you use multiple kinematics technology objects and multiple cam technology objects with firmware version V2.5, you cannot completely assign the "Extended Motion Control Resources". This behavior is corrected with firmware version V2.5.2. Restarting a kinematics technology object (S7-1500T) Using "MC_Reset" jobs with the parameter "Restart" = TRUE at the kinematics technology object can later result in the kinematics technology object refusing all commands with ErrorID 16#8001 with firmware version V2.5. This behavior is corrected with firmware version V2.5.2. 2.3 Improvements in Update 1 Update 1 contains the following improvements and changes: Working with the TIA Portal Stability when working with the TIA Portal has been improved, partly based on the feedback from returned crash reports. Negative non-typed constants in LAD und FBD (S7-1200/1500) Non-typed constants do not contain an explicit type specification. They do not receive their data type until the first arithmetic or logical operation in which they are used. For example, in a MOVE instruction, a non-typed constant that is used as an input is always interpreted with the data type of the target tag. In versions before V15, the data types of non-typed constants were not updated correctly in rare cases after the data type of the arithmetic or logic operation had changed. This behavior has been corrected in V15, so that constants are always interpreted with the data type of the link. With this correction, the semantics of the program can change under special circumstances, especially if you use constants with negative values. If you use negative non-typed constants in your program, check it after upgrading and compile it if necessary. To define the exact data type of a constant, use the typed notation, for example INT#-1. Using cross-references with global constants Displaying cross-reference information in V15 can result in crashes or display problems if global constants are used as indexes or start values in ARRAYs in the program, This was remedied in V15 Update 1. In order for the error correction to take effect, you should regenerate the cross-reference information with V15 Update 1. 8, 6/2018

Improvements in STEP 7 2.3 Improvements in Update 1 To do this, follow these steps: 1. Select the "Settings" command in the "Options" menu. 2. Select the category "General > Cross-references". 3. Click the "Recreate the cross-reference information" button. Note when activating breakpoints (S7-1500 as of FW V2.5) When activating breakpoints, a message appears (entitled: "Breakpoint (0604:000427)") stating that the output values for the connected output modules are being kept in their current state and the CPU is no longer reacting to input values of input modules. If the above-mentioned message is closed with "No", no breakpoint can be activated during the online connection. This behavior is corrected with V15 Update 1. Copying tags of the "ARRAY of STRUCT" data type In rare cases when copying tags of the "ARRAY of STRUCT" data type, comments were not transferred correctly in V15. This was corrected in V15 Update 1. Upgrading programs using IEC timers After an upgrade to V15, some programs containing IEC timers output an incorrect error message "The data type IEC timer no longer exists". This behavior is corrected with V15 Update 1. Moving a rotary kinematics axis using the Kinematics control panel (S7-1500T) With V15 you cannot move a rotary kinematics axis in the machine coordinate system (MCS) using the Kinematics control panel with the operating mode "Jog" if the "Modulo" setting is activated for this axis. This behavior is corrected with V15 Update 1., 6/2018 9

Improvements in STEP 7 2.3 Improvements in Update 1 10, 6/2018

Improvements in WinCC 3 3.1 Engineering system 3.1.1 Improvements in Update 3 Update 3 contains the following improvements and changes: Undoing and redoing actions The behavior when actions are undone and redone has been improved. Compiling and downloading The performance when compiling graphic lists with a large number of svg graphics has been improved. Compilation of projects with an OPC UA connection has been improved Multi-user projects The routines for saving multiuser projects have been optimized. 3.1.2 Improvements in Update 2 TCSB V3.1 OPC UA server If you use the latest version of the TCSB V3.1 OPC UA server, you cannot select the address of an OPC UA tag in the tag browser. You must enter the address manually. Each node in the address space of an OPC UA server is uniquely identified by its NodeId. The following properties of a node ID are used to determine the address of the HMI tag: NamespaceIndex: The NamespaceUri results from the NamespaceIndex (0, 1,..) using the NamespaceTable. IdType: The NodeIdType (i, s, g, b) results from the IdType (Numeric, String, Guid, Opaque). Identifier Address: "ns=" + NamespaceUri + ';' + NodeIdType + '=' + Identifier; Examples ns=http://opcfoundation.org/ua/;i=2262 ns=tcs;s=tcs:[project.station 1.101]DP,DataPoint, 6/2018 11

Improvements in WinCC 3.2 Panels Display in Runtime The display of objects on several levels has been improved for Runtime Professional. Multi-user projects The routines for multi-user project compilation have been improved for Runtime Professional. 3.2 Panels 3.2.1 Improvements in Update 3 Update 3 contains the following improvements and changes: Downloading HMI device images HMI device images that are not contained in the scope of delivery can be downloaded via the Siemens Industry Online Support with entry ID 109746530 (https:// support.industry.siemens.com/cs/ww/de/view/109746530). 3.2.2 Improvements in Update 2 Update 2 contains the following improvements and changes: Loss of license for Runtime options The sporadically occurring loss of the license for the Runtime options "Audit" and "ProDiag" is prevented for the following devices: KP700 Comfort KP900 Comfort KP1200 Comfort KP1500 Comfort TP700 Comfort TP900 Comfort TP1200 Comfort TP1500 Comfort TP1900 Comfort TP2200 Comfort TP700 Comfort Outdoor TP1500 Comfort Outdoor 12, 6/2018

Improvements in WinCC 3.4 Runtime Professional Improvement of the brightness control The brightness control of the display has been enhanced for the following devices: KP1500 Comfort TP1500 Comfort TP1500 Comfort PRO TP1900 Comfort TP1900 Comfort PRO TP2200 Comfort TP2200 Comfort PRO 3.2.3 Improvements in Update 1 Update 1 contains the following improvements and changes: Screens and screen objects in Runtime In the trend view, the behavior of the buttons in the toolbar has been improved. 3.3 Runtime Advanced 3.3.1 Improvements in Update 1 Update 1 contains the following improvements and changes: Screens and screen objects in Runtime For the trend view, the behavior of the buttons in the toolbar has been improved. 3.4 Runtime Professional 3.4.1 Improvements in Update 3 Update 3 contains the following improvements and changes: Display in Runtime Screen change in Runtime has been optimized for dynamized object groups., 6/2018 13

Improvements in WinCC 3.4 Runtime Professional The display in independent screen windows has been optimized. The functioning of the following objects has been improved: PLC code viewer ProDiag overview Criteria analysis view Redundancy The synchronization of alarms after a server failure has been improved. 3.4.2 Improvements in Update 2 Update 2 contains the following improvements and changes: Display in Runtime Picture change in Runtime has been improved For pictures with numerous symbolic I/O fields For multiple, rapid, consecutive picture changes The representation of graphics in individualized controls has been improved. Faceplates The dynamization of the interface properties of a faceplate with user-defined functions has been improved. System functions The method of operation of the system function "TriggerOperatorEvent" has been improved with regard to a tag prefix for screen windows. WebNavigator The WebNavigator has been improved with regard to using faceplates. The routines for printing reports have been improved. 3.4.3 Improvements in Update 1 Update 1 contains the following improvements and changes: 14, 6/2018

Improvements in WinCC 3.4 Runtime Professional Touch operation Touch operation of WinCC Runtime Professional has been improved. Display in Runtime In Runtime, the display of picture objects on different levels has been improved. Picture change in Runtime Picture change times have been optimized. SetOperationLock system function The mode of operation of the SetOperationLock system function has been improved in terms of use with nested picture windows. PLC Code Viewer The PlcCodeViewerExternalClientAccess interface has been optimized in respect of parallel access. S7-DOS V9 Do not deactivate the IPv4 protocol in the Ethernet properties for the network adapter or the SIMATIC Ethernet CPs if you want to use all of the functions of the new S7-DOS V9., 6/2018 15

Improvements in WinCC 3.4 Runtime Professional 16, 6/2018

Improvements in Openness 4 4.1 Improvements in Update 1 Update 1 contains the following improvements and changes: Importing blocks STL, LAD, and FBD blocks are correctly imported, even if the attribute "SliceAccessModifier" is set., 6/2018 17

Improvements in Openness 4.1 Improvements in Update 1 18, 6/2018