Five-Band Remote Access Unit (RAU5x) Quick Installation Sheet

Similar documents
Corning Optical Network Evolution (ONE ) Solutions Mid-Power Remote Expansion Unit (MxU)

Headend Unit (HEU) Quick Installation Sheet

Integrated Headend Unit (IHU) Quick Installation Sheet

HX WCS Indoor DAS Remote Unit Quick Installation Sheet

GX Higher Power 40 W Dual-Band WCS/2.5 GHz TDD DAS Remote Quick Installation Sheet

High-Power 40 W Dual-Band SISO/MIMO DAS Remote Unit (GX)

Corning SpiderCloud SCRN-310 Radio Node for Enterprise Radio Access Network (E-RAN)

Corning Optical Network Evolution (ONE ) SD-LAN Ordering Guide

VI 021 S-DIAS VARAN Control Module

Corning SpiderCloud SCRN-250 Radio Node for Enterprise Radio Access Network (E-RAN)

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Connecting a Cisco Input Module

2201 Rack Chassis User Manual

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

MobileAccessGX Higher Power DAS Remotes 40 W

Wall-Mountable Connector Housings (WCH)

Industrial PoE Media Converter

Closet Connector Housings (CCH)

1 PORT HARDENED SERIAL SERVER

VARAN Splitter PROFINET VSP 042

Connecting a Cisco Reader Module

Closet Connector Housings (CCH)

--- For a screen 1,196 x 1,196 x 50 mm Equivalent absorption area for an object A (m 2 )

330 System. features and benefits. RF Distribution System for Campus and Wide Area Applications. A Corning MobileAccess Solutions Product.

PC 521 Data Recording PC

Junos WebApp Secure 5.0 Hardware Guide

IEI emerge MicroNode Install and Setup Guide. Contents

Closet Connector Housing (CCH) Splitter Module

MobileAccessGX Higher Power DAS Remotes 40 W

MobileAccessVE Control Unit: Dual-Band

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

C-DIAS VARAN Control Module CIV x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE))

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

ICA 012 S-DIAS Interface Module CAN

Pretium EDGE HD Solutions A LANscape Pretium Solutions Product

USER GUIDE. PoE & optical transmission Gigabit Ethernet PoE Switch (GGM GS07P)

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: US-8-150W, US W, US W, US W, US W, US W

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

Connecting a Cisco Output Module

Corning Distance and Link-Loss Budgets for the Cisco 40GbE BiDi Transceiver

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

OptiTect Indoor Local Convergence Cabinet, Gen III Series

OptiSheath MultiPort Terminal

EDGE Solutions Trunk Cable, SMF-28 Ultra OS2, MTP to MTP, 12 fibres

Centrix Platform. Features and Benefits

FX Supervisory Controller Wireless TEC Option Card Installation Instructions

Quick Start Guide. Physical Description. The Port Status LEDs

ISE 021 S-DIAS Interface Module RS232 / RS485

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

RO 051 S-DIAS Relay Output Module

Quick Start Guide. Physical Description.

Operating Instructions APX 320/530/740

D-Link Switch User Manual. Table of Contents

Corning Optical Network Evolution (ONE ) SD-LAN Applications Guide

Closet Connector Housings (CCH)

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink


HARTING econ 3000 Introduction and features

Industrial Ultra Power over Ethernet Splitter IPOE-171S

2M Outdoor Motorized Bullet Camera

AXI 22 AT D Setup Guide

KOM600/KOM600G Fiber Media Converter Hardware Installation Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Heat-Cure Single-Fiber Connectors A LANscape Solutions Product

Operating Instructions APX 320/530/740

KFC-200. Installation Guide

AIR-AP1810W-D-K9 Datasheet. Overview. Quick Specs. Product Details

Wall-Mountable Connector Housings (WCH)

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: US-8-150W, US W, US W, US W, US W, US W

UR51 Industrial Cellular Router

AXP 64 C AT Setup Guide

SolarEdge Quick Installation Guide North America

FlexArmor 24V dc Sinking Input Modules

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual

FuseLite Single-Fiber Splice-On Connectors

Operating Instructions APX 120

Industrial 3-Port Fast Ethernet Media Converter Switches

PACSystems* RXi ICRXIBN0E000A and ICRXIBN0M000A

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual

Hardened PoE Ethernet Switch

System Accessories. features and benefits. standards. An Evolant Solutions Product

CNMC[2]SFP[POE][/M] Series

PLC Racks IC697CHS782/783

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

Quick Start Guide. Indoor Stand-Alone Access Point. SunSpot AC1200 and SunSpot N300.

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

2M IR Mini Dome Quick Installation Guide

GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000

OptiSheath Aerial Terminal, SCA-9T Series

AXP 64 C AT Setup Guide

Installation Instructions. P/N Revision A April Single Dock. P/N Revision A

8~14-Port Managed Ethernet Switch

Installing the Cisco MDS 9020 Fabric Switch

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

CVH Slot Media Converter Chassis Quick Installation Guide

features and benefits

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

6 / 8 Port Gigabit Ethernet Switch with PoE+ optional with 2x SFP Slots

Transcription:

Five-Band Remote Access Unit (RAU5x) Quick Installation Sheet CMA-485-AEN GENERAL INFORMATION 1. The RAU5x must always be mounted parallel to the ceiling (horizontal) or wall (vertical) with a 1-in clearance from the surface on the back and front to allow for proper cooling airflow and for heat dissipation. Le RAU5x doit toujours être montée parallèlement au plafond (horizontal) ou au mur (verticale). Assurez-vous qu il y a un espace de un pouce à l avant et à l arrière afin de permettre un flux d air de refroidissement et dissipation de chaleur adéquat. 2. Required ambient temperature: Wall-mountable installations (vertical): 45 C [113 F] Ceiling-mountable installations (horizontal): 50 C [122 F] 3. The RAU5x unit is provided with a mounting bracket used for mounting on the wall or concrete ceilings (including above acoustic ceiling mounts). Additional mounting accessory kits are available (ordered separately): BR-RAU5US-TOP: RAU5x bracket for floating ceilings tile, mid-mount installation BR-RAU5US-Wall: RAU5x remote bracket for wall-mountable installation; Supports up to two RAU5x units back-to-back 4. Add-on modules (i.e., RxU2325/GEM) are ordered separately and should be plugged into the RAU5x before mounting the unit 5. A broadband antenna is required for RAU5x models ordered without a preassembled connected antenna. 6. External cavity filters are required for installations in which RAU5x modules supporting the corresponding CELL and LTE bands are deployed alongside units supporting the Public Safety service. Installation instructions are provided with each separately ordered filter (AK-CVT700; AK-CVT800). This document provides instructions on how to mount the Corning optical network evolution (ONE ) solutions RAU5x unit and perform the required connections. The scope of this document includes connections to the RF expansion unit (RxU2325) and Gigabit Ethernet module (GEM) (for installations including the plug-in add-on modules). Quick Installation Sheet CMA-485-AEN Page 1

1. PACKAGE CONTENTS Check your package contents to verify that the items in the packing list are included. If any of the listed items are missing, contact your Corning representative. Item Description Quantity Image Five-Band Remote Access Unit (RAU5x): 1 RAU5XUS RAU5XUS-A* *RAU5x model including assembled external broadband antenna Mounting Bracket (preassembled on RAU5x underside) 1 Note: Mounting bracket includes holes in various sizes and locations for flexible installation options. Mounting screws not provided. Safety Cable preconnected to the RAU5x 1 Table 1. RAU5x Package Items 2. LOCATE THE REQUIRED CONNECTION CABLES Step 1: Locate the following connection cables leading from the cable infrastructure: DC wiring: - One pair for MAIN POWER connection - One pair for SECONDARY POWER connection (for installations with GEM add-on) Fiber pairs (Corning SMF-28 fiber or compatible): - One fiber pair for RAU5x module - One fiber pair for GEM (for installations with GEM add-on) Grounding wire For RAU5x models not including external antenna RF jumper cables from installed external antenna Figure 1. Example of Mounting Bracket Installation and Captive Screw Location (Bottom Right) Quick Installation Sheet CMA-485-AEN Page 2

3. INSTALL ADD-ON MODULES For installations with RxU2325/GEM plug-in the add-on modules (ordered separately). Refer to quick installation sheet provided with each module for instructions. 4. INSTALL THE MOUNTING BRACKET (WALL/CONCRETE CEILING) Notes: Step 1: Step 2: When mounting the bracket on a wall, the captive screw (indicated in Figure 1) should always be positioned in the same direction as the RAU5x connectors. In wall-mountable installations, the connectors should face downwards. If installing above acoustic ceiling, allow for at least 1-in above the acoustic ceiling for airflow cooling. Remove the mounting bracket from the RAU5x underside and use to mark and drill appropriate holes for mounting the bracket on the wall or concrete ceiling. Refer to Appendix for bracket dimensions. Any of the applicable screw holes can be used. Drill the appropriate screws (not provided) through the bracket installation holes and secure to surface. See Figure 2. Consider the weight of the RAU5x when determining mounting surface and appropriate mounting screws: RAU5x only (no external antenna or plug-in modules): 10 lbs (4.5 kg) RAU5x and GEM: 11.1 lbs (5.03 kg) External Antenna: 3.7 lbs (1.7 kg) RxU2325: 3.08 lbs (1.4 kg) Figure 2. Example of (Concrete) Ceiling Installation of Mounting Bracket (RAU5x with External Antenna) Quick Installation Sheet CMA-485-AEN Page 3

5. MOUNTING RAU5X ONTO BRACKET Note: The RAU5x connectors should face the bracket captive screw. Referring to Figure 3, perform the following steps: Step 1: Step 2: Step 3: Step 4: Insert the four RAU5x pins into the wide ends of the bracket keyholes. Make sure that the bracket captive screw fits into the designated half-slot on the RAU5x. Lock RAU5x pins into the narrow ends of the bracket keyholes. Close captive screw to secure RAU5x and bracket assembly. Figure 3. Mounting RAU5x Onto Bracket 6. SECURE SAFETY CABLE TO GRID OR CEILING IMPORTANT! Using the supplied security cable, attach the RAU5x to a permanent structure within the ceiling (e.g., acoustic ceiling grid or concrete ceiling above). FIXEZ LE CÂBLE DE SÉCURITÉ À LA GRILLE OU AU PLAFOND IMPORTANT! À l aide du câble de sécurité fourni, fixez la RAU5x à une structure permanente avec le plafond (par exemple plafond acoustique gris ou plafond en béton). 7. GROUND, F/O, AND RF CABLE CONNECTIONS Step 1: Route the cables located in Section 2. Step 2: Step 3: Connect the earth ground to the RAU5x 8-32 x 3/8 grounding screw (one-hole grounding lug required). See Figure 4 for example of RAU5x ground connection. Connect fiber optic pair to RAU5x module LC APC optic connector. See Figure 4. Figure 4. RAU5x Only GND, F/O, and RF Cable Connections Quick Installation Sheet CMA-485-AEN Page 4

7. GROUND, F/O, AND RF CABLE CONNECTIONS (CONTINUED) Step 4: RF connections: *RAU5x only (without preassembled Corning external antenna) connect the RAU5x QMA Ext. Ant. connector to an external antenna via routed RF cable, as shown in Figure 4. *RAU5x+RxU2325 (without preassembled Corning external antenna) connect RxU2325 ANT. QMA connector to the external antenna via routed RF cable, as shown in Figure 5. Note: Supported external antenna types: vertical, directional, or omni-directional antennas *CELL and/or LTE external filters (if required by site planner) connect RAU5x UL/DL filter ports to corresponding cavity filters. Figure 5. RAU5x+RxU2325 GND, F/O, and RF Cable Connections Note: Refer to quick installation sheet (CMA-366-AEN) provided with 700/800 cavity filter or download from Corning Resource Center (Product resources) site. 8. MAIN POWER CONNECTIONS RAU5x MAIN POWER (for RAU5x/RAU5x+RxU2325) DC input power connections (see Figure 6) connect DC wire pair to the terminal block connector: Power input range: 37 to 57 VDC Wire size: 12-30 AWG Maximum consumption:: - RAU5x: 44.5 V; 50 W - RAU5x + RxU2325: 44.5 V; 76 W Figure 6. RAU5x Main Power DC Connections CONNEXIONS MAIN POWER Connexions d alimentation d entrée DC pour RAU5x Main Power (pour RAU5x/RAU5x+RxU2325) connecter la paire de fils DC au bornier de connexion: Plage d entrée de puissance : 37 à 57 VDC Taille de fil: 12-30 AWG Consommation électrique maximale: - RAU5x: 44.5 V; 50 W - RAU5x + RxU2325: 44.5 V; 76 W Quick Installation Sheet CMA-485-AEN Page 5

9. FOR CONFIGURATIONS WITH GEM - CONNECTIONS Step 1: Connect DC wire pair to the RAU5x SECONDARY POWER DC input connector (see Figure 7): Wire size: 12-30 AWG Maximum consumption: - GEM: 4 W - For 2 PoE ports of 802.3af: 46 V; 31 W (Input range: 43-57 VDC) - For 2 PoE ports of 802.3at: 52.5 V; 62 W (Input range: 52-57 VDC) Figure 7. RAU5x MAIN and SECONDARY DC Input Connections Connectez la paire de fils DC au RAU5x connecteur SECONDARY POWER (voir Figure 7): Taille de fil: 12-30 AWG Consommation électrique maximale: - GEM: 4 W - Pour deux PoE ports of 802.3af: 46 V; 31 W (plage d entrée: 43-57 VDC) - Pour deux PoE ports of 802.3at: 52.5 V; 62 W (plage d entrée: 52-57 VDC) Figure 8. GEM Interface Connections Step 2: Fiber connections - connect fiber to SFP module ports as follows: - If using fiber terminated with LC APC (green) connect to pre-inserted APC to UPC adapters - If using fiber terminated with LC UPC connector (blue) remove pre-inserted APC to UPC adapters and connect directly to SFP module ports Step 3: Note: Connect the A and B Ethernet ports to the PoE clients using Ethernet cables. A and B Ethernet ports 10/100/1000BASE-T with 802.3 at compliant Power-over-Ethernet (PoE+) PSE port. Quick Installation Sheet CMA-485-AEN Page 6

10. VERIFY NORMAL OPERATION Referring to Figure 9 and Table 2, verify normal operation of RAU5x and GEM (if installed) modules. Figure 9. RAU5x and GEM Status LEDs Module LED Description RAU5x LINK Steady Green Optical link power to/from the RAU5x is normal Blinking Green Optical power from remote is lower than required Off No optical link detected POWER Steady Green Input power detected by RAU5x Off No power supplied to RAU5x RUN Blinking Green RAU5x boot-up sequence complete and module SW up and running Off No power supplied to the unit GEM (GEM) RUN/STATUS Steady Green (with short blink every ~ 10 sec) GEM On/Normal Steady Yellow GEM Fault Ethernet LINK Steady Green Link Off No link Ethernet ACT Blinking Yellow Activity Off No activity (SFP) LINK Steady Green Link Blinking Green Activity Steady Yellow Fault Off No link (PortA/B) PoE Steady Green PoE enabled Steady Yellow PoE fault Off PoE off Table 2. Normal Operation LED Status Descriptions Quick Installation Sheet CMA-485-AEN Page 7

APPENDIX: RAU5X MOUNTING BRACKET DIMENSIONS 165.3 mm 162.5 mm 134.4 mm 134.4 mm 86.5 mm 13.4 mm LLC PO Box 489 Hickory, NC 28603-0489 USA 800-743-2675 FAX: 828-325-5060 International: +1-828-901-5000 www.corning.com/opcomm reserves the right to improve, enhance, and modify the features and specifications of products without prior notification. A complete listing of the trademarks of is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. is ISO 9001 certified. 2016, 2018. All rights reserved. CMA-485-AEN / March 2018