PDU Branch Current Monitoring Board Installation and Configuration

Similar documents
RELEASE NOTES. .ini file utility, version 1.0. Release Notes:.ini File Utility, Version 1.0. Purpose and Summary. Purpose. Summary

ACSC100 ACSC101. Structural Calculations For Seismic Anchorage. Prepared for: APC Corp. August 28, 2006 RMJ Job No Structural Page 1 Engineers

Rack Power Distribution Unit AP7530, AP7540

Certified Electrician s Instructions How to Connect Mains and an Emergency Power Off (EPO) Switch to the InfraStruXure PDU

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

READ FIRST. Symmetra LX. Start-Up Guide. For use with Symmetra LX UPS Models: Symmetra LX. Rack-mount UPS. Symmetra LX Rack-mount Extended Run

Console Port Server (AP9301, AP9302, AP9303) Installation and Configuration

ADDENDUM. NetworkAIR FM. Contents. Management Card Wizard--1. File Transfers--10

Rack Air Containment System (ACCS1000 ACCS1007) Overview

Installation and Operation

Broadband Automatic Disconnect Switch. User Manual

Operation. Symmetra MW II. Parallel System with Internal Bypass Static Switch. Normal Normal. UPS Summary. X405 UPS Summary.

MasterSwitch VM Power Distribution Unit and Controller

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Rack Power Distribution. Rack power distribution offerings for entry-level networking equipment and high-density server and blade environments

GE Digital Energy Multilin EPM 4600 Quickstart Guide TELEPHONE: FAX: HOME PAGE:

A1. Multilin EPM 4600 Meter Displays DIS3500/DIS5700. Quick Start Guide. GE Digital Energy

Instruction Manual. Rack PDU XP Series. geistglobal.com

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Panduit Basic Rack PDU with Local Meter

Panduit Basic Rack PDU

Instruction Manual Basic Rack PDU VP7541 and VP9571A

Series 3700 Screw Terminal Assemblies Installation Instructions

PM Series Power Meter

Operation. Symmetra TM PX. Configurable PDU 100kW. 208V, 480V, 600V & 208V Transformerless

H704-42(H)(E), H704-42/1(H)(E)

Auto-Transfer Rack Power Distribution Unit

Multilin EPM 4600 Metering Solution

BLUE 3 INSTALLATION GUIDE

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Installation. Symmetra MW II kw 400 V. UPS Summary Normal Normal

60kW InfraStruXure PDU

EnerSure Installation Guide

ZT200 Series Parts Catalog

Initial configuration requirements 7. Overview 7 InfraStruXure Manager Setup Wizard 8

EMC VMAX Best Practices Guide for AC Power Connections

Server Technology Inc.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

RMB Peripheral Units Installation Guide

Installing Cisco RP-Series PDUs

Start-Up Guide. InfraStruXure System. SX Enclosure Two Post Rack Four Post Rack

XCM8800 PSU Cover. Installation Guide. 350 East Plumeria Drive San Jose, CA USA. May v1.0

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

Quick Start Installation Guide

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

TIMETRAX SYNC BELLQ Installation & Use Instructions

Model Number Electrical Compatibility Module Connector Type M LL-S22 M LL-S22-NA M LL-S23 M LL-S23-NA

1.0 Executive Summary. 2.0 Features and Benefits

* * Agilent Power Distribution Unit (PDU) Installation Guide

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

SUN2000-(2KTL-5KTL)-L0. Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

HPE Intelligent Power Distribution Unit Installation Instructions

Installation and Operation Manual

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

60kW InfraStruXure PDU

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

APC APPLICATION NOTE #74

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

TeamWork 400 and TeamWork 600 Kits Installation Guide

The Basics of Selecting Rack-Mount Power Distribution Units (PDUs) and Power Strips

PDU Inspired by Your Data Center. W IEC PDU Series

Service Parts Diagrams. For Model: FSSBID 100H FSSBID LTS FSSBID RACK MT ADP USB AB

AlphaGateway SMG-01PE Quick Start Guide

Power Supply (48Vdc, 2.5A)

Configurable power distribution

M215 Microinverter Installation Planning

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

Kinetix 6000 Axis Module and Shunt Module

Switched Rack Power Distribution Unit

PowerFlex 755 Common DC Input Drives, Frames Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

IntelliLED TM. Controls: User Guide. Picture for DALI only. Wireless adds external antenna. NOTE: These parts are NOT user serviceable

Vertical Console Port Server AP9290. Installation and Quick-Start

Installation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

INTERNATIONAL MODULAR WIRING DEVICES

Connecting the ICIM to Multiple Prisma II Chassis Installation Instructions

Quick Installation Guide Hitachi Travelstar 5K1000

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

MultiVOIP SIP Gateways

FP-PS-4. Features. Installation

Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

Getting Started Guide

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

SLI 15 INVERTER SERIES, 1500 W

Best Practices Guide. EMC VMAX3 Family. Best Practices Guide for AC Power Connections REVISION 2.0. August, 2015

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

Transcription:

PDU Branch Current Monitoring Board Installation and Configuration Inventory (1) (1) (3) (3) Note The branch current monitoring board can be installed only in a PDU with a serial number of XF0314 or higher. Safety Electrical Hazard Before installing the branch current monitoring board, ensure that your system is not receiving power (Total Power Off). Mounting the board in the PDU The branch current monitoring board mounts to brackets in the PDU on the right and left side of each circuit breaker panel. The illustration in step 2 on page 2 shows the mounting brackets on the upper right-hand side of the PDU circuit breaker panel.

Installation How to mount the board in the PDU. 1. Insert the three socket-head screws into the board and attach the retainers to the screws. 2. Attach the board to any of the four sets of mounting brackets inside the PDU. Note The front of the board must face away from the PDU. 3. Secure the board to the mounting brackets with a 5-mm Allen wrench, and torque 14 16 in-lb (1.7N-m). 2 Branch Current Monitoring Kit

How to route power cable wires. 1. Route the phase conductor through a current sensor. If it is a three-phase cable, route each of the L1, L2, and L3 wires through its own current sensor. 2. Connect the L1, L2, and L3 wires to single-pole breakers or to a three-pole breaker. (The illustration below shows single-pole breakers.) 3. Connect the neutral wire (!) to the closest open termination point on the Neutral Bar. 4. Connect the ground wire (") to the closest open termination point on the Ground Bar.! " Branch Current Monitoring Kit 3

How to connect the board to the monitoring unit. 1. Plug one end of the monitoring cable into the port on the board. Note If the board is on the left side of the PDU, the port will be on the bottom of the board. If the board is on the right side of the PDU, the port will be on the top. 2. Plug the other end of the cable into a port on the PDU monitoring unit. Note There are four available ports on the PDU monitoring unit to accommodate up to four boards. The ports are labeled according to their circuit breaker assignments. The following illustration shows the location of the ports on the PDU monitoring unit and the label describing the circuit breakers assigned to each port. Location of Board Circuit Breaker Numbers Upper-left side of PDU 01...41 Upper-right side of PDU 02...42 Lower-left side of PDU 43...83 Lower-right side of PDU 44...84 4 Branch Current Monitoring Kit

Configuration Configure the branch current monitoring parameters using either the Panel configuration option or Global panel config option on the Panel screen of the PDU display interface. Panel Config. Configure the branch metering settings for each Panel Configuration circuit breaker on the distribution panel, or configure both panels Select Range: [01..41] [02..42] simultaneously. To configure a circuit breaker, select the range that includes the circuit breaker. The top line of selections on the screen applies to the top distribution circuit breaker panel on the PDU. The bottom line of selections applies to the bottom distribution circuit breaker panel on the PDU. The panel position numbers on the screen correspond to the numbers on the distribution panel. Odd numbers are on the left; even numbers are on the right. Once you have selected the correct range, configure the settings for each circuit breaker in the range. Pos: The panel positions in the selected range. Breaker: There are two configurable items: The circuit breaker rating, in amps The circuit breaker tie indicator: Define the number of tied panel positions (i.e., associated). You can associate panel positions with circuit breakers, to view the status about each circuit breaker and to receive alarm notification when any of a circuit breaker s poles are above or below the configured branch circuit limit. You can also tie together panel positions that are logically associated. For example, you can tie together panel positions for three separate circuit breakers that are connected to the same PDU power cord and that provide power to the same equipment enclosure. To configure the values on this screen: 1. From the first column, use the arrow keys to scroll up or down to the pole position you want to configure. 2. Press the ENTER key to move to the item you want to configure in the third column (the circuit breaker rating or the circuit breaker tie indicator). 3. Scroll again to select the value you want for the circuit breaker rating or the circuit breaker tie indicator. To associate one panel position with the next position in the list, choose the + character as the tie indicator immediately following the circuit breaker rating. To indicate that the position is not associated with (tied to) the next panel position in the list, choose the ] character as the tie indicator immediately following the circuit breaker rating. When you change the + or ] character that follows the circuit breaker rating in one row, the + or [ character before the circuit breaker rating in the next row also changes to indicate the changed association between the panel positions. For example, this screen shows three, single-pole, 20A, tied circuit breakers occupying positions 08, 10, and 12 on the top right distribution panel. Pos 08 10 12 Breaker [ 20A + + 20A + + 20A ] Branch Current Monitoring Kit 5

Global Panel Config. Configures the same number of poles or circuit breaker ratings for all circuit breakers in both distribution panels simultaneously. For example, if your system uses only three-pole, 20-amp circuit breakers, choose this option, scroll to the value 3 for Poles and 020 for Amp Rating. Select Apply Now and YES to implement your changes. Specifications Branch Monitor Parameters Maximum current (RMS): 95A Maximum current (peak): 135A Maximum crest factor: 3 Minimum current: 0.5A Measurement accuracy: +/- 0.5A or 5% of reading (whichever is greater) Maximum wire size: 0.35in (8.89mm) maximum diameter InfraStruXure System Parameters Branch circuit range: 20 60A Maximum scan (refresh) time: 3 seconds Display resolution: 0.1A 6 Branch Current Monitoring Kit

APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. www.apc.com/support/ Global support searching APC Knowledge Base and using e-support. Contact an APC Customer Support center by telephone or e-mail. Regional centers: Direct InfraStruXure Customer Support APC headquarters U.S., Canada Latin America Europe, Middle East, Africa fif(1)(877)537-0607 (toll free) (1)(800)800-4272 (toll free) (1)(401)789-5735 (USA) (353)(91)702055 (Ireland) Japan (0) 35434-2021 Australia, New Zealand, South Pacífic (61) (2) 9955 9366 (Australia) Local, country-specific centers: go to www.apc.com/support/contact for contact information. Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support. Entire contents copyright 2004 American Power Conversion. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, the APC logo, and InfraStruXure are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only. *990-1646A* 990-1646A 08/2004