DIGITAL CLOCK. DLZ Type. Service manual

Similar documents
USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

CONVERTER OF RS-232/RS-485 INTERFACES PD51 TYPE USER S MANUAL

LARGE SIZE DIGITAL CLOCKS DZ2 AND DZ3 TYPES

ANALYSER OF 3-PHASE POWER NETWORK PARAMETERS ND1 TYPE

MODULE WITH 8 LOGIC INPUTS SM5 TYPE

GSM/GPRS TRANSMISSION MODULE SM8 TYPE

SCREEN RECORDER KD-Series TYPE

PROGRAMMER FOR N15, N15Z, N17Z DIGITAL METER SERIES and P15, P16 TRANSDUCERS

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

ht20 EXAMPLE OF APPLICATION Ethernet www/ ftp / smtp Ethernet TCP IP Ethernet/ internal network 1

TEMPERATURE AND HUMIDITY TRANSDUCER P18(D) TYPE

PROGRAMMER WITH A USB LINK PD14 USER S MANUAL

LARGE SIZE DISPLAY PANELS

MULTICHANNEL DATA RECORDERS

MC 11 EB-2 Power supply cabinet with external bus, AC version

K107A / K107B Half-duplex RS485 serial bus with 3-point insulation

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

KS5 SYNCHRONIZATION METER

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

EC axial fan - HyBlade

CBA HV Circuit Breaker Analyzer and Microhmmeter

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

CEM-C6 INSTRUCTION MANUAL (M187B B)

MU110-6U. Analog output module 6 channel. User guide

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

UNIVERSAL TRANSDUCER AR594

CEM M-ETH INSTRUCTION MANUAL (M060B A)

* * Agilent Power Distribution Unit (PDU) Installation Guide

MULTICHANNEL DATA RECORDERS

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

PanelView Plus/VersaView CE Terminals and Display Modules

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

EC centrifugal module - RadiPac

100% electricity. Automatic transfer switch controllers ATL series

Fiber optic converter audio and CAN TA OPERATION MANUAL

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

THE NEXT TRANSDUCER GENERATION

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Neon pr. ph/ ORP measurement. Applications. Description

Millenium II +: general characteristics

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

NP40 - PORTABLE POWER QUALITY ANALYZER FEATURES

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

TRANSDUCER T4311, T4411

EC centrifugal module - RadiPac

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

A P P L I C A T I O N

ISMG Solar Inverter. General Description. Type Selection. Ordering Key ISMG 1 50 EN. Approvals RD 1663/2000 RD 661/2007 DK5940 VDE

USER MANUAL. WBI412F41 AC current transducer

USER MANUAL. WBI414F21 AC current transducer

Energy Management BUS Adapter Type VMU-B

Energy Management BUS Adapter Type VMU-B 01

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Pulsar EXtreme 2000/3000 VA

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

TSA TEMPERATURE SWITCHES 15.13a

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

TVAC25100 TVAC25110 User manual

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

2-CHANNEL MODULE OF ANALOG INPUTS SM1 TYPE

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Screw terminal panels, Relay output boards, connection cables

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

Power Meter PowerMonitor 500

TRC-190 User s Manual

User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6. /8 DIN Process Indicators and Controllers C100, C150, C160 and V100

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

SUBJECT TO CHANGE WITHOUT NOTICE

Limit switch attachments

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Microlectra bv. 2-CHANNEL MODULE OF ANALOG INPUTS SM1 TYPE USERS MANUAL

QUINT-BUFFER/24DC/24DC/40

USER S MANUAL. DAS-G01 The Power of Tomorrow

Operating instructions. Standstill monitor A / / 2011

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Electronic Temperature Controller. Instruction Manual Version

PCM SLK- Series Inverter Specification

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Installation / Control / Monitoring Technique

QUINT-PS/ 1AC/24DC/ 5

DPT300 transducer range. Technical reference manual BGX R01

T2314, T2414. Instruction Manual

INSTALLATION MANUAL For authorized service personnel only.

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Energy Management Energy Transducer Type ET112

K-LINE. USB RS485 Asynchronous Converter CONVERTERS AND INTERFACES. Serial Converters

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Carbon Monoxide Sensor - ModBus

General information Engineering with Programming package. Display with display

Transcription:

DIGITAL CLOCK DLZ Type Service manual

Table of contents: 1. APPLICATION...5 2. CLOCK KIT...5 3. BASIC REQUIREMENTS AND OPERATIONAL SAFETY INSTRUCTIONS...5 4. CONSTRUCTION AND INSTALLATION...6 5. ELECTRICAL CONNECTIONS...6 6. CONFIGURATION...7 7. INTERFACE...7 8. SPECIFICATION...9 9. VERSION CODE... 10 10. BEFORE SANDING A FAULT REPORT... 11 11. MAINTENANCE AND SERVICE... 11

1. Application Digital clocks of the DLZ type are used to display current time indoors. They can also display the current date and, in cooperation with the P18 transducer, the temperature and humidity. The communication interface of the clock allows for easy configuration of the clock, and the second inbuilt interface RS485 makes it possible to cooperate with the temperature and humidity transducer. The transducer output values can be read by means of the user interface. The DLZ clocks are equipped with a programmed brightness function to allow for energy savings when the clock does not need to work, or when full brightness could dazzle the user. The DLZ clocks are used wherever there is a need for the current time, date, temperature and humidity to be displayed. It is possible to adjust the clock in accordance with the customer alignments. 2. Clock kit The clock kit consists of: DLZ clock - 1 pc. Assembly holder - 2 pc. Service manual Guarantee certificate 3. Basic requirements and operational safety instructions The DLZ clocks conform to the PN-EN 61010-1 safety standard. The following advice must be observed and adhered to during the installation process and operational use: Only qualified technical personnel should perform the installation and connections of the clock. All possible safety stipulations should be observed. The correctness of electrical connections must be checked before supplying them with current. Do not use an autotransformer for connecting the clock to the mains supply. Do not mount the clock outdoors. The display must be used according to its intended purposes only. Removing the panels housing within the guarantee period will cause the guarantee to expire. Disconnect the display from the power supply before opening the housing. The housing contains live terminals hazardous to life and health. When connecting the mains, protect the device with the breaker switch or circuit breaker. The mentioned switch should be in the vicinity of the device, easily accessible to the user and labelled as the cut out of the device.

4. Construction and installation The DLZ clock is made of black painted aluminium sections. The housing offers Protection Classification IP40 in general and of IP 20 on the housing side where connections are located. The view and dimensions of the clock are shown in Fig. 1. Figure 1. View of the clock. The clock may be wall mounted or underslung. It be mounted at any angle. 5. Electrical connections Supply and interface connections should be connected according to this instruction. Improper connection could damage the clock, so prior to making connections carefully read the information given in chapter 3. For connecting interface signal, use cable consisting of twisted pairs from the shield. Each pair should contain the A and B line of each interface. The connecting terminals and function of the terminals are shown in Figure 2. 6 Figure 2. Description of the clock s terminals.

If the ambient temperature was changed rapidly before installation, wait for at least 60 minutes before first switching it on. Attention: RS-485 interfaces are galvaniclly separated from one another and galvanically separated from power supply. Do not connect interface and signals together. After switching on the clock performs a display test. It lights all segments and increases their brightness. After reaching the maximum brightness, the clock proceeds to normal operation. Attention: If during the cooperation of clock and P18 transducer, the clock displays time instead of temperature or humidity. 6. Configuration The digital DLZ clock can be set through the RS485 interface, using the MODBUS RTU standard. The default transmission parameters of the clock are as follows: Address: 1; Mode: RTU 8n2; Bit rate: 9600 bps. The configuration can be modified by writing the required value into the clock registers. The registers map is described in the next charter. Any program enabling to change the value written in the device s registers and working in the MODBUS RTU standard can be used to change the configuration settings. Modifiable basic settings are as follows:: The connection of the panel and the computer or master device parameters; The transmission parameters between the panel and the P18 transducer. The brightness level for day and night, and the hours of day- and night time changes. The display mode - determines which settings are to be displayed by the clock. The time of displaying the parameter - determines the time of displaying the value of the individual parameter. Current time and date. The setting of the P18 connection. The DLZ clocks can display: time, date, temperature and humidity. The user can choose one of the following configurations to display: Time only. Date only. Time and temperature. Time, temperature and humidity. Time, date, temperature and humidity. 7. Interface DLZ clocks contain 2 serial interfaces, working according to the MODBUS RTU standard. One interface is the master in the MODBUS network and it is used to connect the humidity and temperature converter P18. The other is the slave in the network, and is used to connect the clock to the master system, for example the computer. The slave interface makes it possible to set up and read values from the P18 converter. The DLZ clock is equipped with MODBUS functions 3, 16 and 17.

The register map of the clock is as follows. Register Address Operation Scope Description Default 4000 RW 1 247 Address of interface 1 - user interface1 1 4001 RW 0 3 4002 RW 0 9 4003 RW 1 50 4004 RW 0 3 4005 RW 0 9 Mode of operation of interface 1: 0: RTU 8N1 1: RTU 8N2 2: RTU 8E1 3: RTU 8O1 Interface 1 bitrate [b/s]: 0 2400; 1 4800; 2 9600; 3 14400; 4 19200; 5 28800; 6 38400; 7 57600; 8 76800; 9 115200 Response time of the slave device for port 2 shown in 100 ms multiple Mode of operation of interface 2: 0: RTU 8N1 1: RTU 8N2 2: RTU 8E1 3: RTU 8O1 Interface 2 bitrate [b/s]: 0 2400; 1 4800; 2 9600; 3 14400; 4 19200; 5 28800; 6 38400; 7 57600; 8 76800; 9 115200 4006 RW 1 100 Daytime brightness level 100 4007 RW 1 100 Nighttime brightness level 100 4008 RW 0 2359 The day starting hour 600 4009 RW 0 2359 The night starting hour 2200 1 2 5 1 2 4010 RW 0..4 4011 RW 1 250 Display mode: 0 time only; 1 date only; 2 time; temperature; 3 time; temperature; humidity; 4 time; date; temperature; humidity Page duration time - the time interval of displaying a given parameter value in the displaying cycle. The time is given as 100 ms multiple. 4012 Current time in format the hour *100 + minutes 2 50 4013 Current time - seconds 4014 Current date - month*100 + day 4015 Current date - year 4016 Status 4017 Status of connected devices 8

Registers 43XX - configuration for reading additional devices Register Address Operation Scope Description Default 4300 RW 0,1 247 Address of slave device. 0 - switches off the device off 1 4301 RW 0 65535 Base address. 7501 4302 RW 1 10 Number of registers read 4 4303 RW 0 6 4304 RW 1 60 Register type: 0 char type variable 1 unsigned char type variable 2 integer type variable 3 unsigned integer type variable 4 long type variable 5 unsigned long type variable 6 float type variable Review time in seconds. Determines the frequency of querying the slave device. 6 1 The 75XX registers - read values and system settings (fan operation) Register Address Operation Scope Description 7500 R NA Device 1 - The first read register. Temperature. NA 7501 R NA Device 1 - Second read register. Humidity. NA 7502 R NA Device 1 - Third read register. NA 7503 R NA Device 1 - Forth read register. NA 7504 R NA Device 1 - Fifth r read register. NA 7505 R NA Device 1 - Sixth read register. NA 7506 R NA Device 1 - Seventh read register. NA 7507 R NA Device 1 - Eighth read register. NA 7508 R NA Device 1 - Ninth read register. NA 7509 R NA Device 1 - Tenth r read register. NA 8. Specification Power consumption < 15 VA Display The display field consists of seven-segment displays 00 mm and 57 mm high. Communication: - interface 2 R-S485 galvanically separated - transmission protocol MODBUS RTU - functions performed 03, 16, 17 - data format 8n1, 8n2, 8e1, 8o1 - bitrate [KB/s],4; 4,8; 9,6; 14,4; 19,2; 28,8; 38,4; 57,6; 76,8; 115,2 - max response time < 300 ms 9

Response to power failure and return Dimensions see Fig. 1. The configuration data are saved. Case protection classification IP 40, IP 20 on the side of the connecting pins The reference conditions and nominal operation conditions. - operating temperature 0...23...50 C - storage temperature - 20...75 C - humidity...95% - power supply 85...230...253 V a.c. - frequency...50...60 Hz - working position any Standards conformance Electromagnetic compatibility: - noise immunity acc. to EN 61000-6-2 - interference emission acc. to EN61000-6-4 - power failure immunity acc. to EN 61000-6-2 Safety requirements: EN 61010-1 standard compatible case insulation: basic insulation between circuits: basic installation category III contamination degree 2 maximum working voltage difference between earth and the power supply circuits 300 V and other circuits 50 V. 9. Version code Digital clock DLZ - XX X Version Standard... 00 Special...XX Acceptance tests No additional requirement...0 Quality certificates required...1 To be agreed on with the customer... X X the numbering to be determined by the manufacturer Coding example: DLZ - 00 0 designates a DLZ clock standard version with no additional acceptance tests performed. 10

10 Before sanding a fault report If the clock does not work satisfactorily; please check directions below prior to sending a fault report. Trouble The time display flashes Temperature and humidity are not displayed. The clock displays false time and date The clock displays the time for longer than the date. Lack of the communication with the clock Solution The clock s settings are unreliable or the clock s settings were changed. Try to set up the clock. Check the clock s configuration and change the contents of register 4010 if needed. If the configuration is proper, check the connection to the transducer. In case of transmission faults the clock displays the time instead of the temperature and humidity. Set the time of the clock again. The clock can loose the current time and date due to longer power cut s. Other settings are saved. Check the clock configuration and register 4010 contents. The clock is set to read the P18 converter s data, and the converter is disconnected or works improperly. Check if connections are proper and whether the transmission parameters settings conform to the clock s settings. 11. Maintenance and service DLZ clocks do not need periodical maintenance. For cleaning the clock do not use any dissolvent s, petrols or aggressive chemicals which could damage the clock s painted surfaces or front glass. Most suitable for cleaning are antistatic cleaning foams. Do not moisten the inside of the clock while cleansing. 11

MEASUREMENT CONTROL RECORDING SALES PROGRAM DIGITAL and BARGRAPH PANEL METERS MEASURING TRANSDUCERS ANALOG PANEL METERS (DIN INSTRUMENTS) ANALOG and DIGITAL CLAMP-ON METERS INDUSTRIAL and HOUSEHOLD CONTROLLERS CHART AND PAPERLESS RECORDERS POWER CONTROL UNITS and INVERTERS AUTOMOTIVE DASHBOARD INDICATORS ACCESSORIES FOR MEASURING INSTRUMENTS MEASURING SYSTEMS (ENERGY, HEAT, CONTROL) CUSTOM-MADE PRODUCTS WE ALSO OFFER OUR SERVICES IN THE PRODUCTION OF: ALUMINIUM ALLOY PRESSURE CASTINGS PRECISION ENGINEERING AND THERMOPLASTICS PARTS QUALITY PROCEDURES: According to ISO 9001 and ISO 14001 international requirements. All our instruments have CE mark. For more information, please write to or phone our Export Department DLZ-07 Lubuskie Zak³ady Aparatów Elektrycznych LUMEL S.A. ul. Sulechowska 1 65-022 Zielona Góra - Poland Tel. (48-68) 329 51 00 (exchange) Fax: (48-68) 329 51 01 e-mail: lumel@lumel.com.pl http://www.lumel.com.pl 12 Export Department: Tel: (48-68) 329 53 02 or 53 04 Fax.: (48-68) 325 40 91 e-mail: export@lumel.com.pl