OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Similar documents
Room unit with PPS2 interface

Room unit with PPS2 interface

Room unit with PPS2 interface

Room unit with PPS2 interface

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Semi flush-mounted room temperature controllers with LCD

Room Temperature Controller

Room Temperature Controllers

Room Temperature Controller

Semi flush-mounted room temperature controllers with LCD

Master room unit for RRV controllers

Non-communicating room controllers

Semi Flush-mount Room Temperature Controllers with LCD

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

QMX3.P30 QMX3.P70 QMX3.P02 QMX3.P34 QMX3.P74 QMX3.P37. Wall-mounted sensors and room operator units for KNX PL-Link, KNX S-mode and KNX LTE-Mode

Temperature controller Ducted systems

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Communication module to connect M-bus devices to POL6xx.xxx controllers.

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Non-communicating room controllers

Electrical Actuators

Temperature Controller

7-day room temperature controller

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Product and Application Description

7-day room temperature controller

Room thermostat with KNX communications For VAV heating and cooling systems

Weekday / weekend room temperature controller

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Power supply module, bus connection module

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Heating Circuit Controller

Electrical Actuators

Electrical Actuators

Heating Circuit Controller

Immersion Temperature Sensors

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Freely configurable flush-mounted room operator unit for KNX PL-Link

Supplementary operating instructions for your air curtain system Controller TMC 500

Resistance measuring module

EY-RU : Room operating unit, ecounit

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Status display unit with P-bus connection

Universal Controller

EY-RU : Room operating unit, ecounit

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Zelio Control-modular measurement and control relays 1

Temperature controller Multi-zone ducted systems

Product and functional description

Products no longer available

Room automation station

Electromotoric actuators

Room controller. For chilled ceiling and radiator applications CC-02 with Konnex bus communications (S-mode and LTE mode)

Compact universal controllers

Digital input modules

OP10. Pre-programmed, configurable controller for simple applications

Room thermostats with KNX communications

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Extension module for lighting control

TXM1.8RB. TX-I/O Blinds module

Technical Datasheet clima RCM-FC 1. Product description

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12

Product and functional description

Compact Universal Controllers

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

ERF910. RF Repeater. Synco living

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Products no longer available

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Weekday / weekend room temperature controller

Technical Datasheet clima RCM-CC

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

Product and Function Description

EY-RU : Room operating unit, ecounit

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Product and functional description

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

EY-RU : Room operating unit, ecounit

EY-RU 355: Room operating unit, ecounit355

Rotary version, three-position control

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

QSA2700D / QSA2700 / AQS2700 Fine dust room sensor Basic Documentation

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

Pre-programmed room controller with display and communication

PXR11 PXR12. System controllers DESIGO PX

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Web interface BACnet/IP

24-hour room temperature controller

POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

Transcription:

OEM CLIMATIX TM Room unit QAA822 with2- wire interface For use with Climatix controllers Remote control of air conditioning unit Mandík Measurement of the room temperature Buttons for starting, setting the required room temperature, operating mode and fan control LCD display of room temperature, operating modes, time, fan speed and error signalization 2-wire interface to the controller Building Technologies

Application As an instrument In combination with the Climatix controller ensures correct operation of the air conditioner of Mandík company, including control and monitoring of operating parameters. As a room unit The room unit is used in rooms for measuring the room temperature and controlling the air conditioning unit Characteristic The control panel is designed for semi-recessed, surface mount in a recessed conduit box. Cable entry is through the back door. The device consists of the electronics section and the back cover. The back cover can be removed after loosening the locking mechanism. The front cover includes a printed circuit board, a room temperature sensor, a LCD panel and the buttons for testing the dampers, settings the parameters, setting the time, switching the fan on and changing the values. On the back cover are the terminals for connecting a two-wire conductor with communication. Both covers are plastic. Opening the housing Opening the housing is described in the installation manual included in the package. Buttons and display Buttons No. lcon Name Functions 1 On/Off Button for power on or power off 2 Presence It not used in actual configuration. 3 Option Button for changing the required temperature or ending the display actual temperatures 4 Minus Button for changing the selected parameter or temperature 5 + Plus Button for changing the selected parameter or temperature 6 Info 7 Fan Button for fan speed Press the button for activating viewing current temperature or exits to change the desired temperatures. 8 Mode Button for 3 operating modes : comfort, economy and time program 2 / 7

Icons No. Icon Description Room temperature in C (resolution 0,5 C) 1 Set the temperature, It can be changed in resolution 0,5 C 2 Time 3 Fan speed 4 Weekday indicator 5 Air condition unit is off 6 Automatic mode change according to the time program 7 Economy mode active 8 Comfort mode active 9 Cooling 10 Heating 11 Error indicator (specific fault is displayed on the display of Climatix controller in the cabinet) Description of function Description of individual functions - Press the button 'On/Off for switch on the air condition unit. The unit is in the condition before last switching off ('Economy, or 'Comfort ). - Press the button 'Mode for selecting the mode Comfort or Economy - The currently selected mode of the unit is indicated on the display by the icon. - In mode 'off', the unit is turn off, and the controller works in frost protection mode. Heating is turned on only when the room temperature falls below 5 C. - In mode 'Economy', the controller tries to heat or cool to achieve the required temperature. The default setting for this mode is 17 C. This required value can be displayed by pressing the button 'Plus' or 'minus'. - In mode 'Comfort', the controller tries to heat or cool to achieve the required temperature. The default setting for this mode is 22 C. This required value can be displayed by pressing the button 'Plus' or 'minus'. Setting of the required temperature for the "Comfort mode There are two ways for settings the required temperature for the 'Comfort' mode. Short-term is until next change of mode, or long-term. Shortterm is set by the buttons 'plus' or 'minus' during the active mode 'Comfort'. For long-term change, press the button 'Options'. In the screen is displayed flashing parameter 'Set1' with current desired value in the 'Comfort' mode. Use the buttons 'Plus' or 'Minus' for make the changes. Input is ended by pressing the button 'Info '. 3 / 7

Setting of the required temperature for the Economy mode There are two ways for settings the required temperature for the 'Economy' mode. Short-term, until next change of mode, or long-term. Shortterm is set by the buttons 'plus' or 'minus' during the active mode 'Economy'. For long-term change, press twice the button 'Options'. In the screen is displayed flashing parameter 'Set2' with current desired value in the 'Economy' mode. Use the buttons 'Plus' or 'Minus' for make the changes. Input is ended by pressing the button 'Info '. Viewing Information Fan speed Press the button 'Info' for displaying screen with information values of connected sensors, depending on the current configuration of air conditioning unit, for example humidity, supply air temperature, temperature of heating water, outside temperature, etc. Viewing information is ended by the button 'Options'. Press the button 'Fan' for setting the fan speed, If the fan motor is controlled by a frequency converter or if used EC motor. The maximum and minimum speed limit is set by the parameters SP17 and SP18. Between the minimum and the maximum speed, the speed it can be set in six steps. Fan operation is indicated by an icon on the display. If the speed is cannot be changed, then press this button only for turn on and off. Engineering notes The Room unit receives its power from the connected controller via the 2-wire interface (low voltage, SELV). The Control panel must be connected to the ACC071 regulator with a two-core twisted pair cable. It possible the use unscreened cable. Mounting instructions The device is suitable for semi-flush mounting with a recessed conduit box. The unit should not be mounted in recesses, shelving, behind curtains or doors or above or near direct heat sources. Avoid direct sun and draught. The conduit must be sealed on the device side, as currents of air in the conduit can affect the sensor reading The admissible ambient conditions must be observed Mounting instructions are enclosed with the device. Installation Local installation regulations must be observed STOP Warning The equipment is not protected against accidental connection to AC 230 V. 4 / 7

Commissioning Connection After interruption of the two-wired connection, the communication is restored only when the control panel inquire the address of the regulator. The cycle time for questioning is 250 ms. Step Function Description 1 LCD test All segments are displayed for 2 seconds 2 Identification of the connected regulator 3 Ready for operation The room unit is connected with the regulator Climatix Disposal The device includes electrical and electronic components and must not be disposed of as domestic waste. Current local legislations must be observed. Technical data Supply voltage Operating voltage DC 12...15 V The room unit receive its power from the connected controller, via 2-wire interface (SELV, security extra low voltage according to HD 384) Power consumption (from the controller) Max. 0.22 VA Operating date Temperature sensor Measuring element NTC resistance sensor Measuring range 0...40 C Thermal time constant (sensor) 15s Measuring accuracy (5 30 C) ± 1.0 K Measuring accuracy (25 C) ± 0.5 K Display Type LCD Functions displayed - Modification request - Mode selection - Manually selected fan speed - Control sequence - Time and weekday setting (QAA07.5 only) - Parameter setting (only when selected) Interface Type of interface between regulator and 2-wire interface the room unit The voltage signal, logic 0 < 5 V The voltage signal, logic 1 > 7 V Maximum number of regulators 8 Baud rate 4.8 kbps 5 / 7

Cable connections Connection terminals (screw terminals) 0.8 2.5 mm 2 Cable type Max. distance between 2 units 2-core, twisted pair, unscreened 75 m Max. total length of the bus 125 m Housing protection Protection standard to EN 60529 IP 30 Protection class Insulation protection class III Ambient conditions IEC 721-3 Normal Transport operation Ambient air conditions class 3K3 class 2K3 Temperature + 5...40 C 25...70 C Humidity < 85% r.h. < 93% r.h. Mechanical conditions class 3M1 class 2M2 Industry standards Electromagnetic compatibility Immunity for residential, commercial and lightindustrial environments EN 61000-6-1:2001 Emission standard for residential, commercial and light-industrial environments EN 61000-6-3:2001+A11:2004 CE conformity Meet the requirements for CE marking as defined in EMC directive 2004/108/EC Dimensions See Dimensions Colour Front housing, rear housing, key buttons RAL9003 white Weight Excluding packaging 0.12 kg 6 / 7

Electrical connection Terminal layout: 2-wire interface, power supply + Device power supply, data (positive) Device power supply, data (negative) Negative Positive + Dimensions ( mm) 3982M01 3982M02 3982Z07 7 / 7