Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

Similar documents
Accessories IC690ACC900

205 CPU NETWORK ADAPTER F2-UNICON

PLC Racks IC697CHS782/783

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

Appendix G. CJ1W-CIF11 RS-422A Converter

ISOLATED RS-232 TO RS-422/485 CONVERTER

Model User Manual Revision E 04/29/99. OEM Gaging System. Part Number R01

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

P522 Signal Processor

This Datasheet for the IC697BEM733. Series Genius Remote I/O Scanner.

This Datasheet is for the IC693PWR332. High Capacity Power Supply, 12 VDC Input.

DSI-4. DMX Optically Isolated 1x4 Splitter. D Series. DSI_4 Users Manual r3.lwp copyright 2009, 2010, 2011 ELM V. T. Inc.

1. FEATURES AND BENEFITS

Installing the Panel. Installing the Panel

Weight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

Hookingupacomputertothe3-wireSimplicity bus.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

Building the Communication Cable

Proposal for SAS 2.x Specification to Enable Support for Active Cables

JR3 EXTERNAL SENSOR ELECTRONICS WITH ANALOG OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776

VersaMax IP Input Module

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Installation & Operation Guide

CS485. User s Manual. Version ZYPEX, Inc.

GFM TIO GFC TIO. GFM with TIO Mounted. GFC with TIO Mounted TOTALIZER INPUT/OUTPUT FLOW MONITOR/CONTROLLER. Design Features

Manual Industry Interfaces

Optional Accessories 6 2

CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE

GE Fanuc IC695CMM004. Rx3i PacSystem

Manual Fiber Optic Interfaces

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison

MODEL DRIVER Ic Ip VDC

FX-485PC-IF RS485 Interface Unit Hardware Manual

ADAPTER CARDS TRADITIONAL STANDALONE. DATA SHEET page 1/14. Description

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

Classic Brain Boards. Classic Brain Boards. Features. Description. Networking. Part Numbers

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

1 1 Getting Started $ "% # + %#! & %! + % $!% +!% $% # * %&# $ +!% ' *!# * %&# $ + $$ %!% "&% &%"&% # $$ $ +!( % " % $!%! %$ + $) % "$!# %% "!

Series Specialty PLCs

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

Carbon Monoxide Sensor - ModBus

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

PV Rapid Shutdown device

Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL

ReFlx 100 PLUS COLLISION AVOIDANCE SYSTEM

This Datasheet for the IC697CMM741. Series MMS or TCP/IP Ethernet LAN Interface.

CPU Module IC200CPU005

REMOTE LOGIC I/O [INPUT/OUTPUT] PCB (LOGIO) Part No. 46S For use on MicroTrac DSD Local Area Network

Proposal for SAS 2.x Specification to Enable Support for Active Cables

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

JR3 EXTERNAL SENSOR ELECTRONICS WITH SERIAL DATA OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

MT8050iE series. Installation Instruction (1) (2)

Installation and Programming Manual

ANC Series RS-422 Serial Communications Adapter

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

UC-2000 Installation Manual Unicorn Computers Technology Limited

PLCADD1616 User Guide 3/29/10. Overview

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

IC693PWR331 High Capacity Power Supply, 24 VDC Input

H704-42(H)(E), H704-42/1(H)(E)

Integrity Instruments Application Notes. Release 1

PACSystems RX7i IC698CMX016-ED

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Universal Keying Adapter 3+

TABLE OF CONTENTS. Communication Functions

Converter Box Data Sheet

Pmod modules are powered by the host via the interface s power and ground pins.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

GE Fanuc Automation Programmable Control Products. PACSystems RX3i. Serial Communications Modules. User s Manual, GFK-2460A.

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

Integrated Battery Control System LBCS Step-by-Step Setup Guide

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

Overview. The DIN-RS232 has three primary functions: Isolated parallel RS-232 interface Fused power distribution Animatics peripheral expansion bus

Robocolor II System. users guide

DATA CONNECT ENTERPRISE

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

DIP053 QUAD PC/AT TO CAN ADAPTER MODULE

Appendix 3 Using NS-AL002 Converters

Resolver to Digital Expansion Board

ReFlx. ReFlx 100 Collision Avoidance System Instruction Manual Page 1 6/30/99

BOARD LEVEL PRODUCTS GPIB<->RS-422/RS-485 INTERFACE BOARD

VersaMax* Serial Communications Module

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

Hardware Manual RM CANview

XT-9100 Technical Bulletin

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

VersaMax* PROFIBUS Network Interface Unit

Transcription:

July 2000 RS-4 Port Isolator IC0ACC03 The IC0ACC03 RS-4 Port Isolator replaces the obsolete ICCMM0 Isolated Repeater/Converter (also known as the Brick ). This Port Isolator provides the basic functionality of the ICCMM0 Isolated Repeater/Converter except for the converter function. The Port Isolator features 00 volts of isolation in a compact package servicing all IC3, IC, and IC200 PLC product lines. The Port Isolator connects either directly to a -pin RS-4 serial port or though the optional inch (30 cm) extension cable, IC0CBL003, which may be ordered separately. The extension cable is intended for applications where direct connection to the port is obstructed by surrounding equipment or when it is not acceptable for the Port Isolator to protrude from a PLC module. The Port Isolator can operate in either single or multidrop mode, selected by a recessed slide switch on the top of the module (see switch in figure below). The Port Isolator provides the following features: Four opto-isolated signal channels: SD, RD, S, and CTS Electrical compatibility with RS-4 Single or multidrop operation A V DC/DC converter for power isolation Support for hot insertion 0. in. ( mm) 2. in. ( mm). in. (43 mm) IC0ACC03A MULTIDROP OFF ON End View (with pin numbers) -Pin Male End View (with pin numbers) -Pin Female in (30 cm) To Port Isolator -Pin Male IC0CBL003 Extension Cable -Pin Female Figure. IC0ACC03 Port Isolator and IC0CBL003 (30 cm) Extension Cable

2 RS-4 Port Isolator Connector Pin-Outs The Isolator provides two connectors, one -pin male D-type (PL) and one -pin female D-type (PL2). The tables below list the connections for these two connectors. PL: -Pin Male D-Connector Pin Name Type Description - Chassis Ground 2 NC - 3 NC - 4 NC - V - +V power CTS (A ) In Clear to send - 0V - Ground S (B) Out Request to send + NC - SD (A) Out Send data - SD (B) Out Send data + RD (A ) In Read data - RD (B ) In Read data + 4 CTS (B ) In Clear to send + S (A) Out Request to send - PL2: -Pin Female D-Connector Pin Name Type Description NC - 2 NC - 3 NC - 4 TESTID - ID resistor V - +V power S (A) Out Request to send - 0V - Ground CTS (B') In Clear to send + - Terminating Resistor* RD (A') In Read data - RD (B') In Read data +- SD (A) Out Send data - SD (B) Out Send data +- 4 S (B) Out Request to send + CTS (A') In Clear to send - * To terminate the RD balanced line, place a jumper wire from pin to pin. Note: A denotes minus ( ) and B denotes plus (+). A and B denote outputs and A' and B' denote inputs.

RS-4 Port Isolator 3 Installation The Isolator is packaged in a plastic enclosure designed for either () direct attachment to a serial port or (2) attachment through the optional IC0CBL003 extension cable for panel mounted applications. Two M3 thumbscrews secure the Port Isolator to its mating connector. If panel mounting the Isolator using the optional extension cable, you will need to provide the two -32 x 3/ (4 x mm) mounting screws (see Figure 2 below). When installing the Isolator, tighten the connector screws and panel mounting screws (if used) to the following torque values: Screws Size Torque Connector Thumbscrews (supplied with Isolator) 3 mm in./lbs. Panel Mounting Screws (user-supplied) #/32 x 3/ (4 x mm) in./lbs. #-32 (4 mm) screw IC0ACC03A MULTIDROP OFF ON Figure 2. Port Isolator Mounted to Panel #-32 (4 mm) screw

4 RS-4 Port Isolator -pin Male D-Connector PL Optical Isolation -pin Female D-Connector PL2 Termination Resistor +V Output Enable (Always on) OFF Multidrop Switch (S Driven) Output Enable 4 4 Input +Vdc DC/DC Isolated Converter +Vdc Output Ground Ground 2 Figure 3. IC0ACC03 Block Diagram

RS-4 Port Isolator The RS4 Port Isolator supports both port-to-port and multi-drop configurations (Figure 4). In some cases it may be necessary to power the Port Isolator by a source other than the host port. This configuration is used to prevent an interrupt in communications if the host system requires a power cycle. It also prevents power loss to equipment using the port for power. If you wish to use an external power source, you will need to build a custom cable as shown in Figure. pin pin Female Male D-connector Isolator pin pin Female Male D-connector Master PLC 4 4 +V * Terminate at first and last drop only Twisted Pairs Make Connections inside D connectors Slave Device pin port 4 +V * Add termination resistor across pins and Slave Device pin port 4 +V Slave Device 2 pin port 24 2 2 23 22 To Other Slave Devices (Maximum of devices on a multidrop) Figure 4. Multidrop Configuration Connecting Devices with -Pin Ports and 2-Pin Ports

RS-4 Port Isolator Terminate at first and last drops only Slave Device Make connections inside D-connector pin Male D-connector Isolator pin Female D-connector Master PLC Slave Device To device requiring external power Terminate at first and last drops only +V 4 Note: Do not daisy chain +VDC pins. +VDC +V 4 Ground +V 4 Twisted Pair +V 4 Slave Device To Other Slave Devices (Maximum of devices on a multidrop) Make connections inside D-connector Twisted Pair 4 * +V To Other Slave Devices (Maximum of devices on a multidrop) +V 4 * Add termination resistor across pins and Figure. Cable for Supplying External Power Through the Port Isolator

RS-4 Port Isolator Specifications Mechanical RS-4 Installation Hardware Electrical Voltage Supply Typical Current Ground Isolation Conformance Operating Temperature Baud Rate -pin D shell male for direct mounting to serial port on the programmable controller -pin D shell female for communication cable Two M3 thread connector thumbscrews. Recommended torque: in./lbs. (supplied with Isolator) Two #/32 x 3/ (4 x mm) machine screws (user supplied) if mounting to panel. Recommended torque: in./lbs. +VDC (usually supplied by port) 2 ma for Port Isolator circuitry 0 ma available for external equipment 00 Volts EIA-422/4 Balanced Line 0-0 C (32 - F) Those supported by PLC Application Information S Control IC3, IC, and IC200 serial ports use tri-state buffers (line drivers), which have the following three states: Logic, Logic 0, and Disconnected. When used on a shared line, as in a multidrop arrangement, the buffer must be placed in the disconnected state when not transmitting so that it does not disable the line. This is done by means of an internal control signal, which enables the buffer when it needs to transmit and disconnects the buffer when it is not transmitting. This internal control function on these PLC ports is transparent to the user. However, buffer control for a Port Isolator used in a multidrop system comes externally from an S signal from a slave device. In general, the female end of the Port Isolator should be connected toward the Master end of the system. The female end has tri-state buffers (the male end of the Port Isolator only uses two-state buffers). The tri-state buffers are required if the line between the Port Isolator and the Master is shared with slave devices, since only one slave device can transmit at a time and all other devices, when not transmitting, must disconnect from the shared line. Tri-state buffers are not required on the male end of the Port Isolator since only the Master can transmit to slave devices and, therefore, the line is not shared with other transmitting devices. If the line between the Port Isolator and the master device is shared with other slave devices, the Port Isolator s tri-state buffers must be placed in the disconnected state when not transmitting. This is accomplished by the Request to Send (S) signals from slave devices connected to the CTS input on the male side of the Port Isolator (see Examples 2 and 3, below). When an S signal goes high, the buffers are enabled. When the S signal goes low, they are disconnected.

RS-4 Port Isolator Connections and Termination All connections must be made at the serial ports, inside the cable connectors, in a daisy-chain style using high-quality, shielded, twisted-pair cable. No line stubs and no intermediate terminal blocks are permitted. Violating this rule can result in standing waves on the transmission line, which would cause improper operation. When a Port Isolator is applied to a system, it results in two separate lines that are not physically connected. Each must be handled as a separate line for termination purposes. However, only lines longer than six feet (2 meters) require termination. Termination is required on each RD signal pair, but only at the end of the line. As shown by the following figure, what is considered the RD (receive) signal pair by receiving devices is considered to be the SD (send) signal pair by transmitting devices, and what is considered the CTS signal pair by receiving devices is considered to be the S signal pair by transmitting devices. Device Device 2 RD(A ) RD(B ) CTS(A ) CTS(B ) RD(A ) RD(B ) CTS(A ) CTS(B ) Termination is required across RD terminals if line is longer than feet (2 meters). Figure. Typical RS-4 Connections (Shield not Shown) Since the master is the only device that receives slave transmissions (slaves cannot transmit to each other), it must have termination at its receive (RD) terminals, and it (the master) must always be located at the end of its line. The female end of the Port Isolator and most RS-4 PLC serial ports have built-in termination resistors that are connected by installing a jumper on the cable connector. However, the male end of the Port Isolator does not have a built-in termination resistor. To terminate it, either () install a resistor in the cable connector across RD(A ) and RD(B ) at the Port Isolator, or (2) if the Port Isolator male end is within feet of the next slave device, the termination may be done at the slave device. If a resistor is added, its value should be matched, within reason, to the impedance of the cable used. Typical impedance is 0 to 0 ohms. If cable impedance is not known, a 0 ohm resistor would probably be a suitable choice.

RS-4 Port Isolator Power Requirement The Port Isolator requires a power input of VDC at 2 ma (minimum) on pin of the male connector for operation of the Port Isolator circuitry. Additionally, it has an internal power isolator that can provide an isolated VDC at 0 ma output on pin of the female connector that can be used for converters or other low-power devices. If this isolated power output is used, it will increase the Port Isolator s input power requirement beyond the minimum 2 ma. If the Port Isolator is mounted directly to a -pin female PLC serial port, it receives its power directly from pin of the serial port connector. If the Port Isolator is not directly mounted to a PLC port, care must be taken that the voltage drop across the interconnection cable is not excessive. At least 4.VDC is required on pin of the male connector when the Port Isolator is under full load, including any load connected on the VDC isolated output on pin of the female connector. The voltage drop across the interconnection cable depends on () the size of the cable conductors, (2) the length of the cable, and (3) the amount of current required by the Port Isolator and any devices connected to its VDC isolated output. Excess voltage drop will not be a problem for a cable that is a few feet (a couple of meters) long. However, for longer cable lengths, the voltage should be carefully measured at the Port Isolator power input, between pins (+VDC) and (0V) of the male connector, to ensure it is receiving at least 4. VDC under full load. If it is not possible to obtain the minimum voltage with longer cable lengths, use an external power supply mounted near the Port Isolator. Multidrop Switch This recessed slide switch is mounted on the top of the Port Isolator. It can be set with the tip of a miniature screwdriver (do not use a pencil graphite dust from a pencil can damage the switch). When in the ON position, the Port Isolator s tri-state buffers are controlled by S signals on its CTS input on the male connector. When in the OFF position, the Port Isolator s tri-state buffers are activated all of the time, so that, effectively, they function like a standard (two-state) buffer. After ensuring that the female Port Isolator connector is connected to the master device, use the following general guidelines for setting the MULTIDROP switch (also, refer to the Application Examples section for more information): If the Port Isolator s female connector is the only device connected to the master, we recommend you set the switch in the OFF position. If the Port Isolator s female connector shares a line with other slave devices as well as the master, the switch must be set in the ON position, and the S control lines must be connected to the Port Isolator s CTS input on the male connector (in order to control the tri-state buffers). Signal Polarity Some manufacturers label their lines with a or +, such as RD and RD+. However, the EIA RS-4 specification uses the letters A and B, such as RD(A) and RD(B), to signify polarity. In general, the A polarity corresponds to the polarity, and the B polarity corresponds to the + polarity. Reversing the polarity of RS-4 signal lines should not damage the equipment; however, the equipment will probably not communicate if polarity is reversed.

RS-4 Port Isolator Port Isolator Application Examples Example In this example, the Port Isolator isolates the Master from the Slaves. The Slaves are not isolated from each other. Since the Port Isolator is the only device that connects directly to the Master, no S control for the Port Isolator tri-state buffers is required from the slaves. This lack of S control requires that the Multidrop switch be set to OFF, which will place the Port Isolator s female end output buffers in the connected condition all of the time. However, if the S control lines from Slave # and Slave #2 were connected to the Port Isolator, the Multidrop switch could be set to either position and the system would work. Note that the RD terminals at the ends of each line must be terminated (indicated by asterisks) if the line is longer than feet (2 meters). Since there is no built-in termination resistor on the male end of the Port Isolator, either () an external resistor (typically 0 ohms) can be added inside the connector, or (2) if the Port Isolator is located less than 3 feet ( meter) from the nearest slave (Slave # in this example), the termination can be connected at that slave instead. Master Slave # Slave #2 Line Switch=OFF Line 2 Port Isolator Female End Male End Figure. Example, Master Isolated from Slaves Termination required across RD terminals at these locations if line is greater than feet (2 meters) long Example 2 In Example 2, the Master and Slave # are isolated from Slave #2 and Slave #3. Since both the Port Isolator and Slave # share the same line (Line ) to the Master, the Port Isolator s output tri-state buffer must be in the disconnected state when it is not sending. This requires that both Slave #2 and Slave #3, whenever transmitting, must send an S signal to the Port Isolator CTS input on the male (Line 2) end, and it also requires that the switch be set to the ON position. Note that the RD terminals at the ends of each line must be terminated (indicated by asterisks) if the line is longer than feet (2 meters). Since there is no built-in termination resistor on the male end of the Port Isolator, either () an external resistor (typically 0 ohm) can be added inside the connector, or (2) if the Port Isolator is located less than 3 feet ( meter) from the nearest slave (Slave #2 in this example), the termination can be connected at that slave instead.

RS-4 Port Isolator Master Slave # Slave #2 Slave #3 Line Switch=ON Line 2 Port Isolator Female End Male End S Connections Required on this Line Termination required across RD terminals at these locations if line is greater than feet (2 meters) long Figure. Example 2, Master and Slave # Isolated from Slaves #2 and #3 Example 3 In Example 3, the Master, Slave #, and Slave #2 are isolated from Slaves #3 and #4. Since the Port Isolator, Slave #, and Slave #2 all share the same line (Line ) to the Master, the Port Isolator s output tri-state buffer must be in the disconnected state when it is not sending. This requires that either Slave #3 or Slave #4, whenever transmitting, must send its S signal to the Port Isolator CTS input on the male (Line 2) end, and it also requires that the switch be set to the ON position. Note that the RD terminals at the ends of each line must be terminated (indicated by asterisks) if the line is longer than feet (2 meters). Since there is no built-in termination resistor on the male end of the Port Isolator, either () an external resistor (typically 0 ohm) can be added inside the connector, or (2) if the Port Isolator is located less than 3 feet ( meter) from the nearest slave (Slave #3 in this example), the termination can be connected at that slave instead. Master Slave # Slave #2 Slave #3 Slave #4 Line Switch=ON Line 2 Port Isolator Female End Male End S Connections Required on this Line Termination required across RD terminals at these locations if line is greater than feet (2 meters) long Figure. Example 3, Master, Slave #, and Slave #2 Isolated from Slave #3 and Slave #4

RS-4 Port Isolator Example 4 The Port Isolator is used in this example to isolate the programmer (a personal computer), from the IC3 PLC serial port. In this case, an IC0ACC03 Miniconverter is also used since it is necessary to convert the personal computer s RS-232 serial port output to RS-4, which is the standard supported by the PLC s serial port. The Port Isolator plugs into the PLC serial port, and the Miniconverter plugs into the Port Isolator. The use of the Port Isolator in this arrangement is recommended to avoid possible damage to the equipment in cases where it is doubtful that the personal computer and the PLC are at the same ground potential. If the Port Isolator cannot be plugged directly into the PLC serial port, perhaps due to lack of clearance space, panel-mount the Port Isolator and connect it to the PLC via an IC0CBL003 extension cable, which must be purchased separately. The serial port connector on the IC3 power supply has sufficient current capacity to support both the Port Isolator and the Miniconverter. Note that Port 2 on CPUs 3, 32, and 33 are isolated internally and, therefore, do not require an external Port Isolator. IC3 PLC IC3ACC03 Port Isolator IC3ACC0 Miniconverter Programmer Miniconverter Cable Figure. Example 4, Isolating the PLC from a Programmer Changes to Previous Version of this Document The following changes were made to the previous version (GFK-3A) of this data sheet: It was stated that the IC0CBL003 cable came with the Port Isolator. This is not the case. It must be ordered separately. The Application Information and Port Isolator Application Examples sections were added. Errors in the Connector Pin-Out section and in Figures 4 and were corrected.