Station 2. Inverter. PU connector (Note1)

Similar documents
FR-SW3-SETUP-WE. MELSOFT FR Configurator SW3 INSTRUCTION MANUAL OUTLINE SETTING WIZARD FUNCTION WHEN USING FOR THE FIRST TIME TROUBLE INDICATION

FR-SW3-SETUP-WE. MELSOFT FR Configurator SW3 INSTRUCTION MANUAL OUTLINE SETTING WIZARD FUNCTION WHEN USING FOR THE FIRST TIME TROUBLE INDICATION

FR Configurator2 INSTRUCTION MANUAL INVERTER SETUP SOFTWARE SW1DND-FRC2-E OUTLINE PROJECT CREATION FUNCTION TROUBLE INDICATION

Device/PLC Connection Manuals

FR-SW3-SETUP-WE. MELSOFT FR Configurator SW3 INSTRUCTION MANUAL OUTLINE SETTING WIZARD FUNCTION WHEN USING FOR THE FIRST TIME TROUBLE INDICATION

Device/PLC Connection Manuals

Device/PLC Connection Manuals

GP-PRO/PBIII for Windows Device/PLC CONNECTION MANUAL. Keyence Corporation PLC

Device/PLC Connection Manuals

FR-SW3-SETUP-WE. MELSOFT FR Configurator SW3 INSTRUCTION MANUAL OUTLINE SETTING WIZARD FUNCTION WHEN USING FOR THE FIRST TIME TROUBLE INDICATION

Device/PLC Connection Manuals

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Appendix 3 Using NS-AL002 Converters

Device/PLC Connection Manuals

FR Configurator2 INSTRUCTION MANUAL INVERTER SETUP SOFTWARE SW1DND-FRC2-E OUTLINE PROJECT CREATION FUNCTION TROUBLE INDICATION

Power Mate Series Driver

Melsec-Q Link(SIO) Driver

PC CONNECTION Programmable Terminal OPERATION MANUAL

PC CONNECTION Programmable Terminal Operation Manual

Device/PLC Connection Manuals

SIMATIC S5 CPU Direct Driver

OMRON Corporation PLC SYSMAC C Series Connection

FR-SW3-SETUP-WE. MELSOFT FR Configurator SW3 INSTRUCTION MANUAL OUTLINE SETTING WIZARD FUNCTION WHEN USING FOR THE FIRST TIME TROUBLE INDICATION

OMRON Corporation PLC SYSMAC CJ1M Series Connection

OMRON Corporation PLC SYSMAC C Series Connection

THERMO-CON. Model No. HECR002-A5. Keep available whenever necessary.

Device/PLC Connection Manuals

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

DF1 Driver. Rockwell Automation, Inc.

Schneider Electric TSX07/37/57 Series Unitelway Driver

1.1 Siemens S5/S7 Series

Select a Data Communication Interface

Device/PLC Connection Manuals

Motors I Automation I Energy I Transmission & Distribution I Coatings. SymbiNet CFW-11. User s Manual

THT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE

Mitsubishi QSeries QnA Serial Communication

MCF. User's Manual. Air Flowmeter NPT Model. for Communication Functions. No. CP-SP-1301E

TABLE OF CONTENTS. Communication Functions

Citect for Windows Driver Specification Extract Hitachi Driver

SIMATIC S5 CPU Direct Driver

AD Leak Tester INSTRUCTION MANUAL 1WMPD

INSTRUCTION MANUAL FOR JU THYRISTOR REGULATOR COMMUNICATIONS INTERFACE

MDNET-5W. Wi-Fi/Ethernet/RS485 Converter Operation Manual. Version /03/24

Flexi Soft Driver SICK AG

AD Remote Controller INSTRUCTION MANUAL WM+PD A

Sender Receiver Sender

This document hosted by: 10. OPTIONS

Mounting the Model 2601

Module Type Controller SRV. PLC/Host Communication Instruction Manual IMS01P05-E5 RKC INSTRUMENT INC.

XGK Series CPU Direct Driver

USER S MANUAL Enhanced Communication Function

SAPHIR SIO Driver. Siemens Building Technologies

Modbus TCP Client Ethernet Modbus TCP Client Modbus TCP Server Ethernet Modbus TCP Server 5

CML/CMF050 Series. User's Manual

Copyright: December 2017 Nidec Issue: E

Pro-face Memory Link(SIO) Driver

Device/PLC Connection Manuals

Hi5 Robot Driver. Hyundai Heavy Industries

INSTALLATION and OPERATION MANUAL

Ladder Communication Modules

Maximum Value for OEMs SM. NX70 Serial Communications Unit (SCU) User Manual

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

USER'S MANUAL - MODBUS Serial Communication Edition FX3U SERIES PROGRAMMABLE CONTROLLERS

Operating Instructions. Sartorius. Description of the Interface for EA, EB, GD, GE and TE Balances/Scales

Please read here first

Voltage regulator TAPCON 240

Series 370 Stabil-Ion Gauge Controller with RS-485 Interface Option

Yaskawa Electric MP900 Series Driver

A GUIDE TO RS-232 COMMUNICATION WITH FX PLCS

AD-8923-CC. Remote Controller (CC-Link) INSTRUCTION MANUAL 1WMPD B

RGAM Communication protocol description I 94 GB Date: March 10, 1999

Operating Instructions Sartorius

SIMATIC S5 3964(R) Driver

VersaMax* Serial Communications Module

GE Fanuc IC695CMM004. Rx3i PacSystem

EXCELL PRECISION CO., LTD.

Setting the DCM Switches

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Connecting to the Handy Type GP

This document hosted by: Extension Load Cell Cable (OP-02)

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

KTA-250 Anemometer Alarm Card

Serial Communication Prof. James L. Frankel Harvard University. Version of 2:30 PM 6-Oct-2015 Copyright 2015 James L. Frankel. All rights reserved.

ENMAT Premium Data Logger User Manual

User Manual Connection to Mitsubishi MelsecA

A Series CPU Direct Driver

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Lecture-65 SERIAL DATA COMMMUNICATION The data bus of a microcomputer system is designed to transfer data to and from I/O device in parallel - all

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

MODBUS-IN. Modbus Card. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions.

Transmission/ reception tables

AD Leak Tester INSTRUCTION MANUAL 1WMPD B

UL/c-UL(CSA) Approval

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

User s Manual. LG Programmable Logic Controller. Computer Link Module K7F-CUEA MASTER-K K4F-CUEA K3F-CU2A K3F-CU4A. LG Industrial Systems

DN-01 Instruction Manual

TOSVERT VF-S9 Communications Function Instruction Manual

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Transcription:

using the E500 series drives General This data sheet describes the correct techniques for using E500 series inverters on a standard RS485 serial comms link. Up to 32 inverters may be connected. Max comms speed is 19200 Baud. More information can be found in the E500 instruction manual The can be used for communication operation from a personal computer etc. When the is connected with a personal, FA or other computer by a communication cable, a user program allows the inverter to be run and monitored and the parameter values to be read and written. pin-outs Viewed from the inverter (receptacle side) front 8) to 1) 1) SG 2) P5S 3) RDA 4) SDB 5) SDA 6) RDB 7) SG 8) P5S Note: 1. Do not connect the to a computer's LAN board, FAX modem socket or telephone modular connector. Otherwise, the product may be damaged due to electrical specification differences. 2. Pins 2) and 8) (P5S) provide power to the control panel or parameter unit. Do not use these pins for communication. 1. with interface used with several inverters Station 2 Station n Interface / Distribution 10BASE-T cable Termination resistor Title: with E500 s Page 1 of 5

2. When a computer having a RS-232C interface is used with inverters RS-232C connector RS-232C cable Max. 15m Converter* Distribution 10BASE-T cable Termination resistor 3. Wiring of one computer and one inverter Side Terminals Signal name RDA RDB SDA SDB RSA RSB CSA CSB SG FG Description Receive data Receive data Send data Send data Request to send Request to send Clear to send Clear to send Signal ground Frame ground Cable connection and signal direction 10 BASE-T Cable (Note 2) 2 0.3mm or more SDA SDB RDA RDB SG 4. Wiring of one computer and "n" inverters (several inverters) Note: 1. There may be the influence of reflection depending on the transmission speed and/or transmission distance. If this reflection hinders communication, provide a termination resistor. If the is used to make a connection, use the distributor as a termination resistor cannot be fitted. Connect the termination resistor to only the inverter remotest from the computer. (Termination resistor: 100Ω) 2. Make connections in accordance with the instruction manual of the computer used. Fully check the numbers of the computer as they differ between models. Title: with E500 s Page 2 of 5

5. Preparation Connection cable... Connector: RJ45 connector Cable: Cable conforming to EIA568 (e.g. 10BASE-T cable) Personal computer, RS-232C converter... To be prepared when the communication port of the personal computer has RS-232C specifications. Parameters Related to serial communications Pr. 117 "station number" Pr. 118 "communication speed" Pr. 119 "stop bit length/data length" Pr. 120 "parity check presence/absence" Pr. 121 "number of communication retries" Pr. 122 "communication check time interval" Pr. 123 "waiting time setting" Pr. 124 "CR, LF presence/absence selection" Used to perform required settings for communication between the inverter and personal computer. Title: with E500 s Page 3 of 5

6. Communication specifications Conforming standard Number of inverters connected 1:N (maximum 32 inverters) Communication speed Selectable between 19200, 9600 and 4800bps Control protocol Asynchronous Communication method Half-duplex Communication Character system ASCII (7 bits/8 bits) selectable specifications Stop bit length Selectable between 1 bit and 2 bits. Terminator CR/LF (presence/absence selectable) Check system Parity check Selectable between presence (even/odd) and absence Sum check Present Waiting time setting Selectable between presence and absence Parameter Number Factory Setting Setting Range 117 0 0 to 31 118 192 48, 96, 192 119 1 Data length 8 0, 1 Data length 7 10, 11 120 2 0, 1, 2 121 1 0 to 10, 9999 122 9999 0 to 999.8 s, 9999 123 9999 0 to 150, 9999 124 1 0, 1, 2 Title: with E500 s Page 4 of 5

7. Setting Parameter Number Name Setting Description 117 Station number 0 to 31 Station number specified for communication from the. Set the inverter station numbers when two or more inverters are connected to one personal computer. 118 Communication 48 4800 baud speed 96 9600 baud 192 19200 baud 119 Stop bit 8 data 0 Stop bit length 1 bit 1 Stop bit length 2 bits 7 bits 10 Stop bit length 1 bit 11 Stop bit length 2 bits 120 Parity check 0 Absent 1 Odd parity present 2 Even parity present 121 Number of communication retries 0 to 10 Set the permissible number of retries at occurrence of a data receive error. If the number of consecutive errors exceeds the permissible value, the inverter will come to an alarm stop. 9999 (65535) If a communication error occurs, the inverter will not come to an alarm stop. At this time, the inverter can be coasted to a stop by MRS or RESET input. During an error, the light fault signal (LF) is given to the open collector output. Allocate the used with any of Pr. 190 to Pr. 192 (multifunction outputs). 122 Communication 0 No communication check time interval 0.1 to 999.8 Set the communication check time [seconds] interval. If a no-communication state persists for longer than the permissible time, the inverter will come to an alarm stop. 9999 Communication check suspension 123 Waiting time setting 0 to 150 Set the waiting time between data transmission to the inverter and response. 9999 Set with communication data. 124 CR, LF 0 Without CR/LF instruction presence/ 1 With CR, without LF absence 2 With CR/LF Title: with E500 s Page 5 of 5