OBSOLETE. CanWorks itrax Two-Channel Control Unit Installation. Instruction Sheet P/N A

Similar documents
itrax Remote Display

itrax PC Replacement Quick Start Guide P/N Pre-Software Installation

Line Impedance Stabilization Network (LISN)

TECHNICAL DATASHEET #TDAX023300

GE Power Conversion T1930EN INSTRUCTION SHEET REV. 09 MV3000E DELTA MAINS VOLTAGE MONITOR UNIT MVC X 1. DESCRIPTION

Ink-Dot Series II Driver

TBX-1316 High-Voltage Attenuator Terminal Block

F1000 User's Manual. (Version: V1.01)

Sure Coat Modular Gun Control System Part C: UCS ProfiBus Interface Card. Customer Product Manual Part B

Model 3750 Multifunction I/O Card

P/N: AX Applications: power gen set engine control systems oil and gas equipment automation off-highway machine automation

Installing the Tracer MP503 Input/Output Module Ordering number: ,

itrax Spray Controller

Cisco ONS CL Shelf Assembly Hardware

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

TECHNICAL DATASHEET #TDAX Analog Signal Output CAN Controller (SAE J1939)

USER MANUAL. WBI412F41 AC current transducer

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Precision thermometer Model CTR5000

Thermocouple Input Module Product Specifications and Installation Data

FX Input/Output (I/O) Modules XM07 and XM14

TruPortal Dual Door Interface Module Quick Reference

USER MANUAL. WBI414F21 AC current transducer

BSL Hardware Guide for MP35 and MP30-1 -

Model DMX8DIM Installation and Operations Manual

Installation Manual Series PQ-L. Electronic Module. Bulletin /UK

Sure Coat Modular Gun Control System Part C: Discrete I/O Interface Card. Customer Product Manual Part B

TECHNICAL DATASHEET #TDAX023240

SMVector Additional I/O Module Installation and Operation Manual

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

DBC 150/650 Series. Druck Dry Block Temperature Calibrators. GE Sensing. Features

High Density Switch Mainframe and Cards

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

AC Input /AC Output. Module

FP-PS-4. Features. Installation

Sure Coat Modular Gun Control System Part C: Purge Timer Interface Card. Customer Product Manual Part B

TPE 1464 Series Pressure Transducer

Operating and Maintenance Instructions

USER MANUAL. WBV412U01 AC voltage transducer

Applications: Power generator sets and control systems for industrial engine applications.

PRESSURE TRANSMITTER

IGLOO IGLOO EASY INSTRUCTION MANUAL

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

NC-1 Spray Gun Driver

CONTROL MICROSYSTEMS and 5404 Digital Input Module. Hardware Manual

TECHNICAL DATA SHEET. FreeSpace DS 100SE. Loudspeaker. Product Overview. Key Features. Product Information. Applications

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

12-Bit 0-5 Volt Input Adapter (Part # S-VIA-CM14)

NORDSON CORPORATION AMHERST, OHIO USA

Technical Manual Nova: Cabinet Security Management System (CSMS)

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Redundancy Module QUINT-DIODE/40

Series 3000V Input/Output Board

CONCEPT P/N: AX Concept TECHNICAL DATASHEET #TDAX Analog Input CAN Controller CAN (SAE J1939 or CANopen ) with Electronic Assistant

SX90 Process Controller

Programming unit VIATOR HART modems Model PU-H

OPERATOR S MANUAL ATE 1/2 RACK POWER SUPPLY AUTOMATIC TEST EQUIPMENT MODEL

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

E101 - Strain Gauge Transducer Display Module. Contents

Micro Motion Model 7950 and Model 7951 Signal Converters

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

MODEL 805 USER MANUAL

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

IGLOO IGLOO EASY INSTRUCTION MANUAL

Coolwave 2 Control Board Upgrade Kit

Installation Requirements for Conformance to Standards

Access control C485FX. Technical manual

Discrete I/O P/N: AXDIO inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

P2-HSO High-Speed Isolated Sinking/Sourcing Output. Connector Specifications

5401 and 5402 Digital I/O Modules

RAYMAPB. Power Supply and Terminal Box for Marathon MM/MR/FA/FR Sensors. Manual Addendum. Rev. A 06/

S-series Mass Connection Solutions

TAC I/NETTM 1284, 1280, Security Control Unit

TruPortal Output Expansion Board Quick Reference

ACT-1B Series Panel Tachometer

Multi-functional precision thermometer CTR3000

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Analyser Control Unit Mk4. Operating Manual

MDM 011-Z1 Regen Resistor

TruVision IP Thermal Camera Installation Guide

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

OPERATOR S MANUAL BOP (M) (D) 100W, 200W, 400W BIPOLAR POWER SUPPLY

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

PanelView Plus/VersaView CE Terminals and Display Modules

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

User Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION TOOLS REQUIRED. Nonhazardous Locations LR67275

Low-Cost Multifunction DAQ for USB

3/4 U CPCI Serial Case System

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Installation Guide Controller Series E130/E230/E430

MAXIMA+ Series Rotary Level Indicator

Transcription:

Instruction Sheet P/N 1047805A CanWorks itrax Two-Channel Installation WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. WARNING: All installations must conform to national and local codes. The CanWorks itrax Spray Monitor System detects problems in coating application systems by monitoring the fluid pressure at the spray gun, provides warnings and alarms to the operators, and stores process data for quality control. The system consists of: one or more CanWorks itrax Spray Monitor modules, a USB-to-CAN network adapter, and the CanWorks itrax software. The CanWorks itrax Operator Interface runs on an IBM-compatible personal or industrial computer with the Windows 2000 or Windows XP operating system. Communications between the computer running the CanWorks itrax Operator Interface and the Spray Monitors is through a CAN (ler Area Network) network and the USB-to-CAN network adapter. The CanWorks itrax two-channel control unit has two spray monitor modules, a power supply, and terminal blocks for easy installation of a two-channel itrax Spray Monitor System. The control unit comes completely assembled. Installation consists of mounting the box and wiring external equipment to the terminal blocks. Refer to the online Help system in the itrax Operator Interface for Spray Monitor configuration, calibration, system setup, and operation.

2 CanWorks itrax Two-Channel Installation Mounting See Figure 1. Mount the control unit to a suitable surface using customer-supplied 3 / 8 -in. hardware. WEIGHT: 12.7 kg (28 lb) NOTE: The mounting tabs on the control unit may be removed if necessary. Figure 1 Mounting Dimensions Wiring EMC Directive Compliance See Figure 2. For compliance to the European Union Electromagnetic Compatibility Directive (EMC Directive): 1200496A 1. For general safety fuse L1 and L2 with 2-Amp fuses. 2. Cabling from the trigger signal (driver), sensor signal (applicator), and the network cable to the computer must all be shielded and terminated. Drill or punch out holes and install strain reliefs in the bottom, side, or top of the control unit as appropriate to accommodate the wiring. Connect to the main terminal block as shown in the wiring diagram. NOTE: If you are installing the two-channel control unit into an existing CanWorks itrax network, perform the Connecting Multiple s procedure.

CanWorks itrax Two-Channel Installation 3 CAUTION: Do not plug the USB-to-CAN adapter into the computer until the adapter s driver software has been installed. From USB-to-CAN Adapter with DB 9 Connector RS 485 1 TERMINAL BLOCK Network Termination 121 Ω, 1%, 1 / 4 W Metal Film Resistor Pressure Transducer Preampliflier Twisted 2 Pair 2 GUN 1 GUN 2 Timer (High True, Sourcing) 5 to 50 V, 50 ma max) Pressure Transducer Preampliflier Timer (High True, Sourcing) 5 to 50 V, 50 ma max) Twisted Pair Line Shutdown Optional Warning Light Twisted 2 Pair Twisted Pair Line Shutdown Optional Warning Light 2 Gun 1 Fault Contacts (5A at 250 VAC, 5A at 30 VDC) Shown unpowered. Contacts change state upon power up and drop out during fault condition. Gun 2 Fault Contacts (5A at 250 VAC, 5A at 30 VDC) Shown unpowered. Contacts change state upon power up and drop out during fault condition. From Facility Power 240/100 VAC 50/60 Hz, 2A max Power Cord 16 AWG 1 Use RS 422/485, 22 AWG rated cable for all network wiring. Low capacitance 16 pf/ft of less having a characteristic Impedance of 120 ohm nominal (Example: Belden 9841) 2 Two Pair twisted shield, 22 AWG wire (Example: Belden 8723) Figure 2 Wiring Diagram Note: Refer to Nordson drawing 1045603 for internal wiring details. 1200497A

4 CanWorks itrax Two-Channel Installation Connecting Multiple s If your CanWorks itrax network will have more than two channels, follow these steps: NOTE: Leave the termination switches in all Spray Monitors in the OFF position. The resistor shown in Figures 2 and 3 terminates the CanWorks itrax network. 1. Set appropriate network address in the Spray Monitors. Refer to Spray Monitor Configuration in the Spray Monitor instructions (included in the door of the control unit). NOTE: Figure 3 shows a six-channel system. The Spray Monitors network addresses are shown as 01 through 06. The maximum number of channels is 64. 2. See Figure 3. Connect network wiring between the control units: a. Remove the resistor from the NETOUTA and NETOUTB terminals. b. Install RS-485 network cable from the NETOUTA and NETOUTB terminals of one control unit to the NETINA and NETINB terminals of the next. c. Install the resistor in the NETOUTA and NETOUTB terminals of the last control unit on the network.

CanWorks itrax Two-Channel Installation 5 FIRST CONTROL UNIT SECOND CONTROL UNIT THIRD CONTROL UNIT USB to CAN Adapter Figure 3 From USB to CAN Adapter To Second 01 02 From First To Third 03 04 RS 485 Network Cable DB 9 Connector with Termination Resistor Connecting Multiple s RS 485 Network Cable From Second 121 Ω, 1%, 1 / 4 W Metal Film Resistor 05 06 Network Termination Resistor 1200498A Issued 3/04 Original copyright date 2004. CanWorks, Nordson, and the Nordson logo are registered trademarks of Nordson Corporation. itrax is a trademark of Nordson Corporation.

DECLARATION of CONFORMITY PRODUCT: CanWorks / itrax APPLICABLE DIRECTIVES: 73/23/EEC (Low Voltage Directive) 89/336/EEC (Electromagnetic Compatibility Directive) STANDARDS USED FOR COMPLIANCE: EN50081 EN50082 IEC417 EN55011 EN60204 PRINCIPLES: This product has been manufactured according to good engineering practices. The product specified conforms to the directives and standards described above. CERTIFICATIONS: ISO 9001 DNV No. 08796-2003 TUV EN60204 Ernest J. Fena Vice President Liquid and Container Systems Group Date: 27 August 2003 Nordson Corporation Westlake, Ohio DOC13007A