Current Firmware Release Notes

Similar documents
- 1 - Dominion PX Overview: Dominion PX refers to Raritan s family of intelligent power distribution units.

Frequently Asked Questions

SmartZone G5 Firmware Release Notes 2.2.2

- 1 - Dominion PX Overview: Dominion PX refers to Raritan s family of intelligent power distribution units.

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00245, FEBRUARY 19, Release Notes Section Outline

Quest Desktop Authority Full Build Update Release Notes

Dominion PX Overview: Dominion PX refers to Raritan s family of intelligent power distribution units.

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00109, SEPTEMBER 8, Release Notes Section Outline

econnect PDU Firmware Upgrader User Manual

Dominion PX Overview: Dominion PX refers to Raritan s family of intelligent power distribution units.

F. RELEASE NOTES for AP88xx Metered Rack PDU AP89xx Switched Rack PDU AP86xx Metered-by-Outlet with Switching Rack PDU

SNMP Web Management. User s Manual

User Manual PDUTracker

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

Table of Contents SMARTZONE G5 USER MANUAL

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Copyright 2016 IPT PDUUM Revision

Power IQ DCIM Monitoring Version 6.2.1

Using the Offline Diagnostic Monitor Menu

User Manual. Per Port Monitoring Models

PDU Utility. User Manual

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5

Auto Upgrade. Auto upgrade - Network Method

Avocent Corporation ACS 6000 Advanced Console Server Release Notes Version November 10 th, 2010

RAMOS Ultra FW. change log

Intelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability

The following file is used for updating the boot loader: xboot.bin: XSTREAM development platform boot loader image

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

Introducing Server Technology s PRO1 Rack Power Distribution Unit

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

VERTIV. Avocent ACS8xxx Advanced Console System Release Notes VERSION 2.4.2, AUGUST 24, Release Notes Section Outline. 1 Update Instructions

Innovative Electronics for a Changing World INDEX

Table of Contents SMARTZONE G5 USER MANUAL

ForeScout CounterACT Resiliency Solutions

PN5212/PN5320/PN7212/PN7320

Effective Immediately: (For internal and external distribution) Vanguard 3000 Firmware Upgrade Instructions

Managing Software Images Using Software Management

InfraSuite Device Master

CYBER POWER SYSTEMS, INC. INTELLIGENT PDU FIRMWARE RELEASE NOTES V1.1.4 Page 1/7

Techn i c a l Overvie w - EN

Initial configuration requirements 7. Overview 7 InfraStruXure Manager Setup Wizard 8

EP2 EP8 User Manual. Copyright 2007,ATAL

RAMOS PLUS RACK MONITORING SYSTEM INTRODUCTION MANUAL

IPMI Configuration Guide

Polar PDUs POWER MANAGEMENT

SolarPower Pro. User s Manual. Management Software for Solar Inverter

Change and Configuration Management Administration

ForeScout CounterACT. Resiliency Solutions. CounterACT Version 8.0

RackCDU Monitoring System. User Guide R11A EN. Edition February 2016

RackCDU (InRackCDU) Monitoring Software Manual. History: R11B EN. Monitoring Software Manual English

RelNotes x-EN 20 NOV APC by Schneider Electric ( APC part number: D

Connector for sensing cable

Temperature and Humidity Monitoring Solutions Guide

Management Console User s Guide (AST 2500 Chipset)

TFA. KlimaLogg Pro. User Manual. Revision: 1.1

AST2500 ibmc Configuration Guide

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Power IQ DCIM Monitoring Version 6.2.2

Media-Mirror Media-Mirror-Plus Backup System. User s Manual

KEMP360 Central. 1 Introduction. KEMP360 Central. Feature Description

IPDU-A Series User Manual. IPDU-A Series User Manual

AST2500 ibmc Configuration Guide

Configuring Cisco TelePresence Manager

Table Of Contents. 1. Introduction... 1

Contents SMARTZONE G5 USER MANUAL

REMOTE MANAGEMENT CARD FIRMWARE RELEASE NOTES. Ver (Release Date: Apr. 03, 2018)

Active Servicedesk Release Notes

sensorprobe2 / sensorprobe8 User Manual

DSS User Guide. End User Guide. - i -

New Rock Technologies, Inc. Unified Management System. User Guide. Document Version:

Release Note of RMCARD 202/203 Ver (Release Date: 06/09/2017):

Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more.

GIGABYTE Remote Management Console User s Guide. Version: 1.0

Version 3.0 May 2007 CYCLONE TIMING MODULE USER GUIDE

Dell Storage Compellent Integration Tools for VMware

INDEX. Network Power Monitor R10 SNMP

Kaseya 2. Quick Start Guide. for Network Monitor 4.1

InfraStruxure Central 6.0 Release Notes

Set Up Cisco ISE in a Distributed Environment

Configuration Note. AudioCodes One Voice for Microsoft Skype for Business. CloudBond 365. Backup and Restore Functionality. Version 9.

Contents SMARTZONE G5 USER MANUAL

How to setup Failover in Linux NVR

Dell Storage Compellent Integration Tools for VMware

epowerswitch 8M+ R2 User guide Version

Anchor User Guide. Presented by: Last Revised: August 07, 2017

DOCUMENTATION FOR PC EMERGENCY CONTROL DEVICE USB WATCHDOG TIMER

Change History for IBM Switched and Monitored pdu_v01.3_1 5/8/2013

IMPORTANT NOTE for. Choose the zip file v and unzip it in USB. Do not rename the UPG folder. Follow

2015. All right reserved

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

Error code. Description of the circumstances under which the problem occurred. Less than 200. Linux system call error.

Configuring Cisco TelePresence Manager

PCE-IMS 1 User Manual IP Monitoring systems IP Switchable Metered PDU s

Power IQ Version from Version

PDU Utility. User Manual

To upgrade to the i-vu v6.0 application

Added SerialNumber object to ECESSA-MIB Description Device serial number is readable via ECESSA-MIB::SerialNumber.0.

New Product Release. Integrated Intelligent Power Distribution.

Quest Desktop Authority Full Build Update Release Notes

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00290, AUGUST 3, Release Notes Section Outline

Transcription:

Current Firmware Release Notes CPI recommends that all econnect PDU customers upgrade to the current firmware version. Release Versions 1.23.126 & 2.23.126: Upgrade Procedure: Download the zip file from the website. Unzip 924-300520-001-20151016.zip Save cpipack-20151016-svn6014.bin and cpipack2-20151016-svn6014.bin to a USB flash drive in the root folder. Make sure there are no other files with.bin extension in the root folder. Plug the USB flash Drive into the USB port on the PDU and use the LCD menu to perform the firmware upgrade. Confirm the PDU new firmware version after the PDU reboots: o Firmware version: 1.23.126 or 2.23.126 Fixed an issue where Daisy Chains were unable to upgrade secondary members for certain chain lengths and firmware versions Fixed an issue where making use of the daisy chain clone settings feature would fail to copy over the Sum Amps setting Fixed an issue where the primary PDU would not fire off a warning alarm or send emails for the link count falling below the specified threshold.

Previous Firmware Release History: Versions 1.23.112 and 2.23.112: (Released on 9-23-2015) Fixed an issue where setting the Role Change checkbox would trigger a Warning alarm Fixed an issue where the primary web GUI would not update to show loss of daisy chain connectivity if the daisy chain contained so many members Fixed an issue with the LUA scripts which occasionally caused loss of functionality in the Web GUI Fixed an issue with environmental thresholds where certain Celsius values were not being saved correctly Added in the ability for daisy chain failover to be triggered by loss of Ethernet connectivity on the primary Versions 1.23.74 and 2.23.74: (Released on 8 4 2015) Released a new version SNMP design that allows for easier access to data from PDUs on a daisy chain. DETAILS The Unity SNMP design is the second revision of the SNMP design for the econnect PDU. One of the compelling features for the econnect PDU is the ability for the units to be daisy chained together. The main PDU in the chain (Primary) is the gateway for each of the PDUs in the chain. The current SNMP design requires users to fetch a field (PDUMap) that contains a list of all the PDUs in the chain. The user then has to set the selector field (PDUSelect) to retrieve that data associated with the PDU. This design for data retrieval can create problems in the data center if there are multiple data collectors running. 1. Access to the chain must be synchronized. This limits data collection systems in terms of how fast they can retrieve data from the PDUs in the chain. 2. Possible for incorrect data. The data collection system must ensure that the PDUSelect field is set to the correct PDU or it may retrieve incorrect data. 3. Multiple SNMP Gets must be issued for data. Much of the data that is requested will be requested together as a collection. 4. Additionally data collection systems must implement the SNMP Set function instead of having to only implement the SNMP Get function. A PDU is composed of a number of conceptual elements within it. They are: Configuration Information about how the PDU is configured. System Information General system level information about the PDU. Input Lines Information about the input lines for a PDU. Branch(es) Information about the branch(es) in the PDU. Outlet(s) Information about the outlet(s) in the PDU. Sensor(s) Information about the sensor(s) in the PDU. Within the Unity design, the Configuration elements only apply to the Primary PDU and Alternate PDU in the PDU Chain.

The other conceptual elements are translated into SNMP tables. The SNMP Tables are: PDU Table This table identifies all of the PDUs associated with the Primary PDU. The table contains columns that describe each PDU and its abilities to the user. PDU Line Table This table identifies all of the Input Lines for the PDU Chain. PDU Branch Table This table identifies all of the Branches for the PDU Chain. PDU Outlet Table This table identifies all of the outlets for the PDU Chain. PDU Sensor Table This table identifies all of the sensors for the PDU Chain.

Version 1.22.182: (Released on 2 13 2015) Added Support for using the PDU Selector in SNMP requests rather than having to perform SNMP SET operations to retrieve data from PDUs in a daisy chain. (See Details below) Added support for a new LCD. DETAILS PDU Selector The SNMP OIDs currently used by the econnect PDU are composed of two parts: 1. The base OID. The base OID is 1.3.6.1.4.1.30932.1.1. 2. The functional OID. The functional OID are at most the last 3 digits in the request OID. EX: Outlet 1 Current OID = 1.3.6.1.4.1.30932.1.1.3.5.1 Base OID: 1.3.6.1.4.1.30932.1.1 Function OID: 3.5.1 The PDU Selector design adds an additional part to the OID schema. The new part would be the PDU Selector Field. EX: Outlet 1 Current OID = 1.3.6.1.4.1.30932.1.1.3.5.1.65432 Base OID: 1.3.6.1.4.1.30932.1.1 Function OID: 3.5.1 PDU Selector: 65432 If a PDU Selector value is not specified, then the Primary PDU in the PDU Chain will utilize the original method of PDU Selection. The following would be the workflow for accessing the data from a PDU chain using this method. 1. Retrieve OID.1.3.6.1.4.1.30932.1.1.5.2 (pdumap) to retrieve a list of all the valid values for the PDU Selector. The values in the OID are space separated. 2. For each value in the pdumap field, request the value for the PDU by appending the value to the end of the OID. EX: 1. Retrieve OID.1.3.6.1.4.1.30932.1.1.5.2 = 4567 8975 2356 9087 1032 2. Iterate over each PDU and retrieve XY Branch Current a. Retrieve OID.1.3.6.1.4.1.30932.1.1.3.1.1.4567 = 1000 b. Retrieve OID.1.3.6.1.4.1.30932.1.1.3.1.1.8975 = 9900 c. Retrieve OID.1.3.6.1.4.1.30932.1.1.3.1.1.2356 = 2000 d. Retrieve OID.1.3.6.1.4.1.30932.1.1.3.1.1.9087 = 2500 e. Retrieve OID.1.3.6.1.4.1.30932.1.1.3.1.1.1032 = 1200

Version 1.22.1: (Released on 7 25 2014) Improved PDU boot up sequencing. Improved firmware upgrade for Standalone and Daisy chained PDUs. Improved remote firmware upgrade capability. Version 1.21.215: (Released on 6 12 2014) Bootloader revised to use a second image of the PDU kernel for use if the primary image is corrupt. Web GUI now displays the bootloader revision number on the administration page of a master/standalone PDU. Web GUI properly handles empty log directories when log files are exported. The LCD display now shows the bootloader revision number on the 'info' page. The Outlet Groups now show total power. Changed the Export Logs page to show files by selected folders which speeds page loading. A display page issue is fixed when exporting logs if logging had never been turned on, or the current log folder has no file. If the PDU time has been previously synched with a time server and the user time is different than PDU time, then the user is no longer redirected to the admin advanced page to change time. Version 1.21.116: (Released on 3 21 2014) Total current for 3-phase PDUs is hidden on both on the LCD display and Web GUI since direct summation is not a valid operation. Single phase PDU total current is still displayed. Temperature alarm emails are sent in units of Fahrenheit or Celsius according to the PDU s configuration. Blank authenticated usernames are allowed (i.e., anonymous login) for SMTP. The problem of not sending alarm notifications during very early stages of the PDU boot process has been fixed. Better internal detection and correction of stuck threads. Fixed hang scenario if the system time is changed under certain circumstances. Handle the case when user incorrectly configures SMTP port to 0. Only terminate dead sessions after a timed-out command at of least 5 minutes.

Version 1.21.24: (Released on 1 13 2014) The LCD display font size was increased for better readability. The Master and Second PDU algorithms were revised for better fail-over and resume operation if a network connection is lost and then subsequently restored. Terminology displayed on the web GUI was modified to be consistent with accepted industry standards. Line input currents are now displayed in addition to the branch currents on both the LCD display and web GUI. Outlet currents are now displayed on the LCD display for Monitored Pro (P4) and Switched Pro (P6) models. If an alarm or warning is triggered for any outlet, the outlet currents are shown in red or yellow respectively on the LCD or web GUI. The web GUI now shows linked PDUs underneath the appropriate master in a more intuitive device tree representation. Branch labels were changed to reflect Delta (XY, YZ, ZX) and Wye configuration (XN,YN,ZN). For 6 breaker units, a number indicates the breaker set (XY1,YZ1 etc). Version 1.17.232: (Released on 5 31 2013) The time Synchronization feature generates copious error messages when there is no time server or if it has problem sync ing the time. After 6 months of logging errors it could fill up the storage and prevent any further webgui logins, network service reconfiguration and firmware upgrade. Fixed by keeping in the error log only the last error, therefore not allowing it to grow. Fixed branch and outlet currents to not show 0 if the load exceeds 21A.