iworx RA-834 Recorder

Similar documents
IX-228/S Data Acquisition Unit

instruction manual DataCapsule-Evo Cat. No UGO BASILE S.R.L. /

APPENDIX E: IWX3XX HARDWARE MANUAL

The iworx 214 and LabScribe V2.0 Tutorial. Overview

Tutorial - Introduction to LabScribe and the IX-ELVIS

BSL Hardware Guide for MP35 and MP30-1 -

Restrictive and Obstructive Airway Diseases Set-up

Experiment HC-1: Blood Pressure, Peripheral Circulation, and Body Position

SCIENCEWORKSHOP 750 INTERFACE. Instruction Sheet for the PASCO Model CI Introduction

iworx Sample Lab Experiment HP-3: Interference of Stimuli on Associative Tasks - The Stroop Effect

Restrictive and Obstructive Airway Diseases Set-up

PRODUCT SHEET. 40HP Monaural Headphones OUT01E Foam Ear Inserts: LED

GS202 Encoder Switch

PRODUCT SHEET INTERFACE MODULES

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

The LabScribe Tutorial

Analog Input Sample Rate

ECHO AIO TEST INTERFACE

PC104P-16AIO Bit Analog Input/Output PC104-Plus Board

EDX-10 Series. Compact Recording System

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

BX8 8-Channel Digital Amplifier

The way PC-based instrumentation should be

INSTRUCTION MANUAL. Dual-System Signal Interface

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

EDX-10 Series. Compact Recording System

1 Place the iworx/214 unit on the bench, close to the computer. 3 When the dialog box appears, select ahk214.iws and then click Load.

Experiment 1: The LabScribe Tutorial

Slick Line Acquisition System Manual

Student Quick Reference Guide

C2 NerveMonitor Intraoperative Neuromonitoring

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

16AIO Bit Analog Input/Output Board. With 16 Input Channels and 8 Output Channels

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE HVA-100 HIGH VOLTAGE AMPLIFIER MODULE FOR EPMS SYSTEMS

Overview: Functional Description:

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

high performance signal conditioner cards

Dept. of Electrical, Computer and Biomedical Engineering. Instrumentation for the data acquisition laboratory

E101 - Strain Gauge Transducer Display Module. Contents

LAUREL ELECTRONICS, INC.

48-Bit Isolated Digital I/O

PMC-16AIO 16-Bit Analog Input/Output PMC Board With 32 Input Channels, 4 Output Channels and 16-Bit Digital I/O Port

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Neurobit Optima+ 4 / 2 BT / USB Neurobit Optima 2 BT / USB

MODEL 9250 Preliminary data sheet

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

digiclip Data sheet DF31CAN Special features B en

digiclip Data sheet DF31DP Special features B en

ECL150/ECL150e. Eddy-Current Displacement Sensor INSTRUCTION MANUAL. Measurement Systems from LION PRECISION

GEN series Calibration Kit

Neuromaster MEE Intra-operative monitoring system

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

OBSOLETE. CanWorks itrax Two-Channel Control Unit Installation. Instruction Sheet P/N A

C50- PARALLEL PORT INTERFACE CARD Rev. 1

Manual for PSDC_OPT_EIGHT_01: Optics Power Supply

SENSING A WORLD OF POTENTIAL TM. Dry Sensor Interface DSI 10/20. Simple Ambulatory No-prep Dry EEG System

12-Channel, 12-Bit PMC Analog Input/Output Board

Isolated Process Current Input with Loop Power 7B35

Weight Height WxDxH Cuff Size. Housing Program Environmental Conditions

PCI-FPGA-1B User Guide

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Expandable Modular Data Acquisition System inet-400 Series

Expanding the Basic GL7000 Configuration

DBK48. Multipurpose Isolated Signal-Conditioning Module. Description. Supports up to Sixteen 8B Modules

32-CHANNEL 16-BIT TRANSDUCER INPUT PMC

Trident and Trident X2 Digital Process and Temperature Panel Meter

C10- PARALLEL PORT INTERFACE CARD Rev. 8

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8395A...

ADI12-16(PCI) Isolated Multi-Function Analog Input Board for PCI ADI12-16(PCI) 1. Ver.1.01

USER S MANUAL C10- PARALLEL PORT INTERFACE CARD

RT USB3000 Technical Description and User Manual. Revision 4.1.

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

16-Channel 16-Bit PMC Analog I/O Board

Signal Conditioning Modules and Terminal Boards

PCD-400A/430A. Sensor Interface. Carrier Wave Type Compact and Moderate Prices. Data Recorders/Analyzers MEASURING INSTRUMENTS

RHYTHMIA HDX TM. Mapping System

HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

ECONseries Low Cost USB DAQ

Specifications USB-1616HS

C2 NerveMonitor Intraoperative Neuromonitoring

User Manual. MAXISIM 2000 Patient Simulator

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8396A...

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

AD16-16(PCI)EV. Features. High-Resolution Analog Input Board for PCI AD16-16(PCI)EV 1. Ver.1.02

DSP Filter System. Author: Nels Pearson Org Date: July 5, 2007 Rev Date: July 6, Doc Number: AIGO-009

TMS 9000 Series Torque Measurement System DIGITAL TELEMETRY DESIGNED FOR TODAY & TOMORROW

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

JR3 EXTERNAL SENSOR ELECTRONICS WITH ANALOG OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776

USB-1602HS-2AO Specifications

USB 2.0 External HDD Enclosure 3.5" (8,89cm)

Additional products and features

Transcription:

iworx RA-8 Recorder Hardware Manual iworx RA Recorder (IX-RA-8) Overview The iworx RA Recorder is the most advanced and feature-rich physiological data acquisition system on the market. It comes standard with eight general purpose input channels, a low voltage and high voltage stimulator, eight digital inputs and outputs, a built-in barometric pressure sensor, and four iwire inputs. The iworx RA exhibits the high resolution, low noise, and flexibility required for a variety of research applications including cardiac function, hemodynamics, isolated tissue and organ studies, exercise physiology research, metabolic function studies, neuroscience and both oocyte and epithelial voltage clamp applications. Incorporating innovative iwire serial interface technology and advanced LabScribe data acquisition and analysis software, the iworx RA Recorder accommodates a wide range of sensors, transducers, and other devices. Included Items RA Recorder (IX-RA-8) USB cable (C-USB) Universal VDC power supply (A-UP-DC--A) LabScribe data acquisition software and Quick Start guide (LS-0) Front Panel iworx RA Recorder Front Panel LabScribe is a trademark of 0 A through A: BNC connectors for single-ended transducers.

iworx RA-8 Recorder A through A8: Each channel is equipped with a transducer amplifier to allow connection of virtually any physiologic transducer via a DIN8 connector. iwire Connectors: Accept up to four serial iwire interfaces including the iwirebg, iwire-bio, iwire-bio8, and iwire-ecg. The iwire-bg interface can record up to four channels of data. Three of the channels are isolated biopotential amplifiers capable of recording ECGs, EMGs, EOGs, EGGs, and EEGs, while the fourth is a dedicated GSR amplifier (used with the C-ISO-GSR sensor). The iwirebio and iwire-bio8 include four or eight biopotential amplifiers respectively. The iwire-ecg is capable of recording a -lead human electrocardiogram. S and S: Low voltage stimulators. Parameters for the stimulators, such as pulse width, frequency and amplitude, may be changed on the fly using controls located in the LabScribe software toolbar. Standard protocols include Pulse, Train, Step, Triangle, Ramp, and Custom. Connected via BNC connectors. HV Stimulator: High voltage isolated stimulator. Suitable for human striated muscle studies. Connected via HV safety connectors. Rear Panel iworx RA Recorder Rear Panel Power switch DC Power connector: Accepts VDC,. A DC converter. Ground: Accepts a banana plug. EM and EM: Accept the Event Marker (EM-0) and certain other transducers (including the FRS-0 Foot Reaction Switch and the PHRM-00 Polar Heart Rate Monitor receiver). Synch-Out, Synch-In: To synchronize recordings across multiple RA Recorders so that channels from multiple devices can be sampled simultaneously. BNC connectors. USB connector Digital Input/Output and : Up to eight digital inputs and outputs are available to monitor and control external TTL devices like pumps and valves.

iworx RA-8 Recorder SPECIFICATIONS BNC INPUTS (A-A) Number of inputs Input range ±0 VDC Resolution bit Connector BNC cable DIN8 TRANSDUCER INPUTS (A-A8) Number of inputs Input range ±0 VDC Resolution bit Isolation No Excitation ± VDC, 00 ma Connectors DIN8 (see figure below for pin configuration) Gain Programmable with input resistor HIGH VOLTAGE STIMULATOR OUTPUT Connectors HV Safety Output range 0- ma Compliance 00 V Max ON time 0 ms LOW VOLTAGE STIMULATOR OUTPUTS (S and S) Resolution bit Connectors BNC Output range ± VDC at ma Modes Pulse, Train, Constant, Step, Ramp, Triangle, Custom DIGTAL INPUTS and OUTPUTS Input 8 independent lines, TTL input, Megohm input impedance, V maximum Output 8 independent lines, TTL output level, ma maximum load per line A/D CONVERTER Sampling speed 00k Hz aggregate Interface USB.,.0, full speed GENERAL Power VDC,. A Enclosure and Dimensions Plastic; cm W, cm D,. cm H Warranty years Software LabScribe recording and analysis software

iworx RA-8 Recorder DIN8 TRANSDUCER INPUTS (A-A8): The A-A8 inputs of the IX-RA-8 have a bridge amplifier interface. These inputs provide +/- V excitation power for transducers and have a differential inputs that go to an instrumentation amplifier. The Gain of the instrumentation amplifier can be set by placing a gain resistor between pins and 8 of the DIN8 input. This allows for customizing the gain for each sensor. The wiring diagram for the DIN8 Transducer inputs is shown below. DIN8 transducer connector pin configuration Digital Input connections: Digital outputs are available on a DB9 Male Connector on the back. Digital Inputs Din Pin 0 8 V 9

iworx RA-8 Recorder Digital Output connections: Digital outputs are available on a DB9 Female Connector on the back. The mapping of the digital outputs is as follows: Digital Outputs Dout Pin 0 8 V 9 How to Use the iworx RA Recorder The iworx RA Recorder is controlled by LabScribe recording and analysis software. LabScribe has an intuitive interface for setting up acquisition screens, calibrating signals, and analyzing data on up to 8 channels simultaneously at sampling rates as high as 00K samples/second. To set up and start to use the iworx RA Recorder: ) ) ) ) ) ) ) Download LabScribe from. Be sure to install the software for the appropriate computer platform (Windows or Mac OS) before connecting the hardware for the first time. In order to download software from the iworx website, you will need to register as a user. Plug in and switch on the iworx RA Recorder. If you will be running an experiment that uses an iwire device, connect the device before turning on the RA Recorder. Double-click on the LabScribe shortcut to open the software. You should see a message indicating that the iworx RA Recorder has been recognized by the software. There are a number of advanced software modules available for LabScribe. These include modules for research involving intravascular blood pressure, ventricular pressure-volume loops, metabolic function, and ECG analysis. Connect the desired transducers to the appropriate channels. If you need to connect an iwire device once the RA Recorder is already running, it must be turned off, the device connected, and then the RA Recorder turned back on. Channels can be configured manually by using the LabScribe Preferences, accessed in the Windows Edit menu, and the Macintosh LabScribe menu.

iworx RA-8 Recorder 8) 9) Here channels can be turned on or off, pre-set filters can be selected, and computed channels can be configured. Views can be configured, and stimulator parameters can be set. See the LabScribe User Manual for details. Some channel parameters can also be changed from the individual channel menus in the recording window. If you are using the Low Voltage Stimulator or the isolated High Voltage Stimulator, connect your stimulating electrodes to the appropriate stimulator and use LabScribe to control the stimulator as instructed in the LabScribe manual. Littleworth Road, Dover, New Hampshire 080 (T) 800-- / 0--9 (F) 0--