BEETLE /Fusion Compact. Installation Guide

Similar documents
icore Kiosk system Installation Guide

BEETLE MSR Module. Swipe Card Reader. for BA7x. User Guide

BEETLE /FUSION Pole Mount Kit. Installation Guide

BEETLE /Express BEETLE /Express 15. Operating Manual

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

BA63USB. BEETLE /FUSION Customer Display. Operating Manual

1.0 Description. 2.0 Unpacking. 3.0 Installation

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

DS-1H05 Ethernet-over-Coax Extender. User Manual

ADL-100 Operator s Manual

2 Mesa Ethernet Dock User s Manual

Installation and Maintenance

icore Kiosk System Operating Manual

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Monarch 9414 Printer. TC9414EM 7/99 Rev. AB 1999 Monarch Marking Systems, Inc. All rights reserved.

icore Kiosk System Operating Manual

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

CANADIAN D.O.C. WARNING

IE-MediaChassis/1. Operation Manual

Installer/User Guide

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement

NCH-1000 (Multiple Breaker Types) Installation Instructions

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

MC 11 EB-2 Power supply cabinet with external bus, AC version

Cat. No KT/B. Installation Data

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

Operator s Handbook. Monarch FreshMarx 9417 Food Freshness System. TC9417OH Rev. AE 1/ Avery Dennison Corp. All rights reserved.

FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING)

FIBER OPTIC A/B/C/D SWITCH (LATCHING)

INSTALLATION INSTRUCTIONS

PC Media Converter, Switching (TP-TX/FX)

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

DVI Splitter Amplifier DS01. User s Manual. Preliminary version Copyright 2012 SHENZHEN BIGTIDE TECHNOLOGY CO., LTD

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

NSD/M1 Installation Instructions

Mini Wireless Barcode Reader Quick Guide

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

User Guide Microsoft Portable Power (DC-21)

CHS 7Ci. Bluetooth Cordless Barcode Scanner. Quick Start Guide

4170 POS System Installation Guide

VC-B10U HD Camera (USB 3.0 Camera) Installation Manual - English

Giga-MiniMc TX & RX USER MANUAL

FZ-VEBG11x. Cradle. Model No. FZ-VEBG11 1. Model No. U Universal R China 1: Area U: Universal R: China

Husky MP2500 User Leaflet

Allworx Tx 92/24 Telephone Expander Installation Guide

3M RFID Tracking Pad Model 770

2DScan TM Barcode Scanner

IP Set-top Box (STB) Model No.: SP-110. Rev

5 B&W Rear View System Camera

SANnet II Family Safety, Regulatory, and Compliance Manual

Safety and Radio-Frequency Interference

This document will show you how to set up the Hotwire 6205 ADSL Modem, and how to customize its configuration to get the most out of this product.

MT /12-Slot Digital MultiTasker

Personal MiniHub. Personal MiniHub RX LINKPORT #AUI PORT 5 UP LINK PWR JUNE 2001 LE2650A LE2650AE CUSTOMER SUPPORT INFORMATION

EVO-TM2A EVO-TM2B Touch Screen Monitor

Model Bulk Sampling Scale. User s Manual

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Installation and Operating instructions for. Control Cabinet PC C6210. Version: 1.4 Date:

Rack Input Module Installation Instructions

Installation- and Operating instructions for. Build-in Industrial PCs C3620, C3640 from Version: 3.0 Date:

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

International Headquarters

Installation and Operating instructions for Industrial PC series C61xx from Version: 3.0 Date:

PTZ Control VMC Joystick

Daily use. indicating that the loud speakers

Stage Rack Installation Guide

Installation and Operating instructions for Industrial PC series C61xx up to Version: 2.6 Date:

Installation and Operating instructions for. Control Cabinet PC C6240 from Version: 2.0 Date:

YJ Carat and Gold Scales

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

DRD-4 DRD-4 JULY 1992 FX140A CUSTOMER SUPPORT INFORMATION

CSM200 Expansion Tray

Mobile UHF Reader. Quick Guide. For full user s manual, please contact your local distributor. Mobile UHF Reader Quick Guide (Rev2) P/N:

TL-PA4010 AV600 Powerline Adapter

iq 16 Sync Charge Box

Quuppa LD-7L Installation Guide and Safety Information

CMSA-100 Manual. Cinema Media Server Automation

Installation and Operating instructions for. Control Cabinet PC C6250 up to Version: 1.6 Date:

Neets Switching Relay - 2. Installation manual

CNK600 Cable-Nook Interconnect Box

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Table of Contents. Federal Communications Commission (FCC) Statement...2

Manual Version: V1.00. Video Decoder Quick Guide

Network Camera. Quick Guide DC-B1203X. Powered by

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

Installation Job Aid for VSP 4850GTS

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

user manual AMOS-2000 Universal Compact, Chassis System, Supporting Nano-ITX Embedded Boards Revision

Warning! This monitor is equipped with Mini USB port, signals and power is obtained from standard USB 2.0 or USB 3.0 port. Do not expose this unit in

CANADIAN D.O.C. WARNING

Infosystem Remote Touchscreen Installation Instructions

Handset Charging Rack OpenStage WL 3 / OpenStage WL3 Plus. Installation Guide A31003-M2000-J

WIRELESS BLUETOOTH BOOMBOX

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

EMC1600 Series Media Converter and Ethernet Extender Chassis

Transcription:

BEETLE /Fusion Compact Installation Guide

The reproduction, transmission or use of this document or its contents is not permitted without express authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Delivery subject to availability; technical modifications possible. Copyright Wincor Nixdorf International GmbH, 2011

BEELTE /FUSION COMPACT Installation Guide Edition Mar 2011

Contents Contents Manufacturer s Certification...1 Tested Safety...1 FCC-Class A Declaration...2 BSMI (EMC for Taiwan)...2 Introduction...1 Symbols used in this guide...1 Important safety precautions...2 Installation notes...2 General safety precautions...2 Planning the Installation...4 Device dimensions...4 Device dimension from side view...5 Device dimension from top view...6 Required operation space...7 Installation site requirements...8 Installation...9 Removing the packaging...9 Installing RAM...10 Installing harddisk...12 Connecting the power cord...14 Connecting the serial connector...20 Appendix...23 Technical data...23 AC Power Adapter...24 Power Cord Selection...25 I/O connection ports...26 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Manufacturer s Certification Manufacturer s Certification The device complies with the requirements of the 2004/108/EC (EMC Directive) and 2006/95/EC (Low Voltage Directive). Therefore, you will find the CE mark on the device or packaging. Tested Safety The BEETLE /Fusion has been provided with the symbol for Tested Safety. In addition, the device has received the UL symbol and cul symbol. 01750171532 C BEETLE /FUSION COMPACT Installation Guide 1

Manufacturer s certification FCC-Class A Declaration This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not in-stalled and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Le présent appareil numérique ne génère pas de bruits radioélectriques dépassant les limites applicable aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. BSMI (EMC for Taiwan) The device complies with the requirements of the BSMI (Bureau of Standards, Metrology and Inspection, Ministry of Economic Affairs) directive CNS14348 with regard to Electromagnetic compatibility with the limits for a Class B product. 2 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Introduction Introduction This installation guide provides you with the information you require to install the Beetle /Fusion system. Symbols used in this guide - Text following this mark represents an item in a list. Text in quotation marks contains references to other chapters or sections in this document. Paragraphs following this symbol are actions to be performed in the specific order.! WARNING Text following this symbol has to be given special attention in order to avoid damage or injury. NOTE This symbol identifies paragraphs which contain general notes to facilitate use of the device and help avoid operating errors. 01750171532 C BEETLE /FUSION COMPACT Installation Guide 1

Introduction Important safety precautions! WARNING Please read the following notes carefully before doing any work on the device. Installation notes - When installing the device and/or doing any work on it, make sure that it is disconnected from the power. General safety precautions This device complies with the relevant safety regulations for information processing equipment. - Note the warning and information labels on the device. - The device is equipped with a safety-tested power cable, which must be connected only to a grounded outlet. - Always hold the plug when removing the power cable. Never pull the cable itself. - Have damaged power cables replaced immediately. - The lithium battery must be disposed of in accordance with local regulations for special waste. - If the display element is damaged and the liquid crystal solution leaks out onto your hands or clothing, please wash your hands or clothing immediately under running water for at least 15 minutes, using soap or alcohol. If the liquid comes into contact with your eyes, consult a medical doctor immediately. 2 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Introduction - Make sure that there is always free access to sockets used or to the electrical circuit-breakers of the house installation. - In case of an emergency (e.g. damaged cabinets, control or power cables, liquids or foreign objects in the device), switch off the device immediately and inform the customer service responsible for you. - During the thunderstorm, data transmission lines must not be connected or disconnected. - Only use accessories and extension components that have been approved by us. Nonobservance can result in damage to the system or violations of regulations concerning safety, radio interference and ergonomical requirements. - To clean the device only use cleaning agents approved by Wincor Nixdorf International GmbH. Repairs! WARNING Repair work may only be carried out by authorized personnel. Unauthorized opening of the device or repair work carried out improperly could result in considerable danger to the user. In case of noncompliance, Wincor Nixdorf International GmbH excludes all liability. 01750171532 C BEETLE /FUSION COMPACT Installation Guide 3

Planning the Installation Planning the Installation This chapter provides you with the information you need to prepare for the installation of the system. Device dimensions All dimensions are specified in millimetres. The views of the systems are not drawn to scale. 4 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Planning the Installation Device dimension from side view 01750171532 C BEETLE /FUSION COMPACT Installation Guide 5

Planning the Installation Device dimension from top view 6 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Planning the Installation Required operation space Wall BEETLE /FUSION System 50 mm 50 mm! WARNING Reservation of minimum space is required to ensure proper ventilation during the operation of the device. Reserve at least 50 mm of operation space from the side of the device to its nearest barrier / wall. 01750171532 C BEETLE /FUSION COMPACT Installation Guide 7

Planning the Installation Installation site requirements The installation area must be flat leveled. When choosing the installation site, make sure that - the system is sheltered indoor - If this system is taken from a cold environment into the operating room, moisture condensation may form. The system must be absolutely dry before being put into service; an acclimatization period of at least two hours must therefore be observed. - No cascading of power cables The system needs to be installed on the table surface and not on the floor. If necessary, appropriate arrangements must be made. 8 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Installation Installation This chapter describes the steps to be taken to install the system. All dimensions are specified in millimetres. The diagrams are not drawn to scale. Contact the person in charge of planning the installation to verify that all preparations have been performed completely and professionally and that none of the required power and data cables are missing. Removing the packaging Remove the packing material of the system or the modules ordered. Dispose of the packaging which is no longer needed according to the regulations of your country. 01750171532 C BEETLE /FUSION COMPACT Installation Guide 9

Installation Installing RAM Remove the screw to access the RAM slot (see picture below). remove screw 10 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Installation Insert the RAM into the RAM slot and make sure it is engaged properly on the slot (see picture below). Ensure that the RAM is inserted in this orientation RAM slot Close the cover and tighten the screws. 01750171532 C BEETLE /FUSION COMPACT Installation Guide 11

Installation Installing harddisk Remove the screw to access the harddisk slot (see picture below). Remove screws 12 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Installation Insert the harddisk into the harddisk slot and make sure it is engaged properly on the slot (see picture below). Ensure that the harddisk is inserted in this orientation Harddisk slot Close the cover and tighten the screws. 01750171532 C BEETLE /FUSION COMPACT Installation Guide 13

Installation Connecting the power cord! WARNING Ensure that the AC power point is switched off before inserting the specified power cord into the AC power point. To connect the system to the power source, plug the connector of the power adapter into the power connector at the rear of the system. To assess to the rear of the system, press the left and right edge of the plastic cover to unlatch the cage of the cover (see picture below). Press the edge of plastic cover to unlatch 14 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Installation Press and release the arm cover to remove it from the rear of the system (see picture below). Remove arm cover 01750171532 C BEETLE /FUSION COMPACT Installation Guide 15

Installation Press the display module downward to ease the access of the I/O shield cover (see picture below). 16 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Installation Slide the I/O shield cover to the right to unlatch before you slide downward the cover to remove the cover in order to access the I/O of the system (see picture below). I/O shield cover 01750171532 C BEETLE /FUSION COMPACT Installation Guide 17

Installation Plug the power cable onto the system by routing it through the cable holder of the system. Make sure that the cable is routed and connected securely (see picture below). power cable routing path 18 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Installation Connect all the required peripherals and network port into the I/O ports of the system. Do the reverse to attach all the covers removed to the system. Plug the power plug into the socket outlet. The socket-outlet is to be installed near the device to ensure easy accessibility to the plug. 01750171532 C BEETLE /FUSION COMPACT Installation Guide 19

Installation Connecting the serial connector To connect the serial connector to the system, plug the serial connector into the serial port at the I/O area at the rear of the system. To assess to the rear of the system, press the left and right edge of the plastic cover to unlatch the cage of the cover (see picture below). Press the edge of plastic cover to unlatch 20 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Installation Press and release the arm cover to remove it from the rear of the system (see picture below). Remove arm cover 01750171532 C BEETLE /FUSION COMPACT Installation Guide 21

Installation To allow the serial connector to fit within the I/O area, take note that the recommended connector length is not more than 3 cm (see picture below). max. 3cm 22 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Appendix Appendix Technical data Beetle /Fusion Compact Dimensions: Height: Depth: Width: Weight of device: 464 mm 440 mm 320 mm Approx. 13 kg Climatic category Operating Transport Storage Input voltage Input current IEC 721-3-3 class 3K3+ 5 to +40 C IEC 721-3-2 class 2K2-25 to +60 C IEC 721-3-1 class 1K2 +5 to +40 C 24V DC (nominal) 7.5A (max) 01750171532 C BEETLE /FUSION COMPACT Installation Guide 23

Appendix AC Power Adapter The AC power adapter used must be Wincor Nixdorf s qualified and has to meet the following minimum requirements and industry standards: Rated Input voltage 100 / 240 Vac Input Voltage range 90 to 264Vac Input Frequency range 47 to 63 Hz Rated Output voltage 24V ± 5%, Rated Output current Approvals & Certification 7.5A (min) UL Listed, TUV-GS, BSMI, CCC, CE 24 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Appendix Power Cord Selection If the power cord is not provided with the system, the user has to ensure that a certified power cord is used as required by the Safety Regulation of the country. Countries USA Canada Germany Japan Taiwan China Safety Approvals UL CSA VDE PSE BSMI CCC For other countries not mentioned in the above list, please check with the local authority. 01750171532 C BEETLE /FUSION COMPACT Installation Guide 25

Appendix I/O connection ports 24VDC input COM2 COM3 LAN (RJ45) USB-H2 USB-H3 Cashdrawer (RJ12) 26 BEETLE /FUSION COMPACT Installation Guide 01750171532 C

Published by Wincor Nixdorf Pte Ltd 2, Kallang Sector Singapore 349277 Part No.: 01750171532 C