SAGEM MAJ Installation Guid

Similar documents
Work Instruction. Sigma L1 Legacy Setup

Using Sigma and Sigma Lite readers with Secure Admin

Controlsoft Identity and Access Management Software Controlsoft Identity Access Management Software

1. Pre-installation. 2. Installing TeamViewer. Copy the files from the DVD to the C: drive on the pc.

Controlsoft Identity and Access Management Software Controlsoft Identity Access Client Software

Knowledge Base Article

Sagem MEMS 7.3 Quick Installation Guide

Working with the Sigma series should be done on a Test environment before going *Live*

ievo ULTIMATE INSTALLATION GUIDE

User Manual. Before using this device, read and follow all instructions for safety

Quick Start Guide V5.0

5.5 AS Layout. GeoVision Technical Handbook 77

ALLDAY TIME SYSTEMS LTD. Allday PT1400 Biometric User Guide

MorphoManager User Manual. Table of Contents

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

for Sagem SIGMA Readers

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

Lab - Install Windows 7 or Vista

Wireless 300N 3G quick install

Example two door Setup.

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

Fingerprint Identification Proximity Reader. Quick Installation Guide

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

SignMax v9.1. MAX Systems Installation manual

M2GO & M1 Operating System Installation

BIOC3 V1 USER S MANUAL. Biometric Reader v. b1

Capacitive Fingerprint Reader User Manual

X200 BIOELECTRONIX. Operating Instructions. X200 Main Interface. Clear or Backspace. Menu Key. On Duty IN & Shift UP

Ethernet Network Card Installation and Operation Manual

NEXT BIOMETRICS NB-3020-U2 WINDOWS 10 INSTALLATION GUIDE VERSION: 1.0

COMELIT AUDIO PLAYER ART

H2i. s u p p o r f i n g e r t e c. c o m. H2i. Simple Fingerprint Door Access & Time Attendance System. User Guide

DG-HR1160M Portable Power Bank 3G Router User Manual

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

SAGEM MA520 READERS FINGER & SMART CARD ENROLLMENT

APP-108 Firmware, Calibration SD Card Rev. 1.4 APPLICATION NOTE MCS-TOUCH OPERATING SYSTEM UPDATE

Product Family: Networking Hardware Number: AN-NH-012

8.9.2 Lab: Configure an Ethernet NIC to use DHCP in Windows Vista

FEATURE USA. TI 300MHz USA. New. User. second

BERNINA Embroidery Software Installation

WSG Series of intelligent mechatronic gripping modules Interfacing to Universal Robots

MCS-TOUCHSCREEN Auto Disk Clean up

P6210 PN: 86085A A

IPS-2101h. Quick Installation Guide V1.0

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

itrax PC Replacement Quick Start Guide P/N Pre-Software Installation

StarBoard FX/FX-DUO Wireless Connection Setup Manual (Windows Vista)

RC-SV Configuration Guide Revision 3

System Galaxy Quick Guide CONFIGURATION AND OPERATION

Installing LE History Record Reader program software.

T-7 FINGERPRINT TERMINAL. HARDWARE USER'S MANUAL Rev 1.1

RC-SV Configuration Guide (Rev 4)

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

Dot Matrix Indicator Programming

SMT107 User Manual User Manual (QCF42); Version 3.0, 8/11/00; Sundance Multiprocessor Technology Ltd. 1999

ekeynet setup basic steps (941)

Operation manual For NG BIOSINGLE Version 1.1

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

XPort Direct+ Demonstration Kit Quick Start Guide

Face & Fingerprint Recognition Product

Table 1 - SDIO Pinout. Pin SD 4-bit Mode SD 1-bit Mode SPI Mode. 1 CD/DAT3 Data Line CS Card Select

SAGEM FINGERPRINT BIOMETRIC CONFIGURATION

VTRAK E-Class/J-Class Quick Start Guide

Zodiac iclass II OPERATOR GUIDE

Quick Setup Guide AMG Skywave III AMG8300S series Wireless Radios Products

How to use a Finger Then Keypad access. Design for: Sigma and Sigma Lite + For Users to use a Finger AND Keyboard access

Access control panel U-Prox IC E (Elevator control)

FINGERPRINT TERMINAL HARDWARE USER'S MANUAL

Eaget Fingerprint Flash Drive

OpenROV. Update Software Image From SD Card

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

Canlan INSTALLATION MANUAL

Matrix-605 WinCE ARM9 Industry Box Computer User Guide

PT100 and PT100W. PT100F and PT100FW. Ethernet Clock with Proximity Badge Reader

C5100 Computer Connections & Software Install Guide

User s Manual. Please Read before Installation (Combustion Pressure Analysis Software)

Installing and Using VeritiLink Software Quick Reference Card

Axxis Biometrics LLC. BioAxxis L113 Fingerprint Door Lock Programming Kit

NX-588E USB Flash Programmer Instructions v1.1

Table of Contents.

UPDATING THE SYSTEM MANAGER SD Updating the System Manager with Prism 2

Models Affected: Matrix T7xe/7xe consoles

How to Update NN3D to v2.07 (Combo Update) MFDBB

Race Keeper Pectel ECU Data Module User Guide v1.1 January 2012

Grove - Fingerprint Sensor

Fast operation of IP Villa System V 1.0

Innovative Electronics for a Changing World INDEX

WELCOME. Network: Only use Shielded CAT5 cable for network communication.

QUICK INSTALLATION. MSX-E1731 Ethernet multifunction counter system /2016

M-4132 Quick Start User Guide

Instruction Guide. 2 Channel Ultra ATA/100 PCI Card PCI2IDE100. The Professionals Source For Hard-to-Find Computer Parts. Revised: December 5, 2002

Wavestore VMS v6 Installation Instructions

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

BERNINA Embroidery Software Installation

Simple Card Reader for Door Access & Time Attendance System. User Guide

Programmer for flash micro computers. User s Manual

SX100 as a NTP Server

State of the art hyper-optimized video management platform designed for ease, speed and efficiency. Blackjack BOLT-LX

Phantom Quick Start User Guide Vision Research - AMETEK Material Analysis Division

Transcription:

SAGEM MAJ Installation Guid Version 0. 1 Prepared by: Corné Coetzee Softcon Software Control Services (Pty) Ltd. 7 March 2017

Revision History Name Date Reason For Changes Version MDH 19-Sep- 2014 Initial document 0.1 MDH 14-Jul-10 Cover Page 0.2 Contents 1. Information & Requirements... 2 2. Wiring the MAJ Reader... 3 4. Configuring the IP Address & Loading the database... 4-7 5. Configuring Wigand Settings for MAJ....8-10 6. Installing SAGEM Drivers and DLL s... 10-21 7. Setting up SAGEM reader on Softwin3.21-23 Information In this document we will go thru a step by step installation procedure of the SAGEM MAJ reader. You will learn how to setup the IP address, how to load the databases, how to wire the reader and how to setup the reader on Softwin3. There are two types of SAGEM MAJ readers. 1. SAGEM MAJ Bio this MAJ reader can only use finger print templates for access control. 2. SAGEM MAJ Dual This MAJ reader has the functionality to use finger print templates or cards or even both fingers and cards. Requirements 1 x SAGEM MAJ Reader. 1 x 4 core Mylar screen cable. 1 x RJ45 CAT 5 Network cable. 1 x 4GB Memory stick or smaller.

Wiring the SAGEM MAJ reader There are two ways to power the SAGEM MAJ reader. The firs way is to use the power from the Softcon controller. The second way is to use a POE switch (Power over Ethernet). The Wigand wires are essential for the MAJ reader. This will allow the MAJ to send a unique number to the controller so that the controller can see if the person is allowed into the area. Pin-outs for Wigand MAJ Reader Wigand out GND Ground (Black). D1 Data Clock Hi (White). D0 Data Clock Lo (Green). CR3xx Controller Wigand In 4 Ground (Black). 3 Data Clock Hi (White). 2 Data Clock Lo (Green). Pin-outs for Power MAJ Reader Power output CR3xx Power output +12V 12V Power (Red) 50 Power out 12V (Red) GND Ground (Black) 49 Ground (Black) See Figure 1.1

Configuring the IP Address To configure the IP address on the MAJ reader you will need the following: 4GB Memory stick or smaller. SAGEM S USB Network Tool application. This tool can be found on the Softcon CD or you can download it from http://www.softconserv.com/downloads/morpho/tabid/133/default.aspx Creating the IP Address Please follow these steps below. 1. Run the USB Network Tool.exe 2. On the Next screen type in the IP Address, Subnet Mask and the Gateway for the MAJ reader.

3. Click on the Write File button. On the Save As screen browse to the 4GB or smaller Memory stick that was inserted into the PC. In the File Name type in a unique name. then press the Save button. 4. Now if you go to the 4GB or smaller memory stick. You should see the following two files. NB: Make sure the MAJ reader is turned off before plugging in the 4GB or smaller memory stick into the MAJ reader.

5. Plug the 4GB or smaller memory stick into the MAJ reader. Turn on the reader. The reader will go thru a couple of beeps and colors. When the reader starts to flash light blue you can remove the 4GB or smaller memory stick from the reader. The reader will then reboot. Once the reader is done booting up you should then be able to ping the reader from the command prompt. NB: If the MAJ reader starts flashing yellow after booting up you need to manually load the database on the reader. To load the database on the reader you first need to download one of the following files. MAJ-500DB.zip This is for a 500 user license database for the MAJ reader. MAJ-3000DB.zip This is for a 3000 user license database for the MAJ reader. Please note that you can t use a 3000 user database with a 500 user license.

Uploading the database to MAJ reader. 1. Right-click on the downloaded file and select extract. 2. Inside the folder copy the two files to a 4GB or smaller memory stick. NB: Make sure the MAJ reader is turned off before plugging in the 4GB or smaller memory stick into the MAJ reader. 3. Plug the 4GB or smaller memory stick into the MAJ reader. Turn on the reader. The reader will go thru a couple of beeps and colors. When the reader starts to flash light blue you can remove the 4GB or smaller memory stick from the reader. The reader will then reboot. Once the reader is done booting up the LED should start flashing purple. NB: Please note that depending on the firmware installed on the MAJ reader the LED lights might vary.

Configuring Wigand settings for MAJ By default the MAJ reader is set to transmit 26bit Wigand information. This can be changed thru the Configuration Tool located on the Softcon CD or to download from the Softcon website. MAJ Bio Can be set to either 26bit or 30bit. MAJ Dual Can be set to 26bit, 30bit, 34bit and 38bit. Using the Configuration Tool Follow these steps below to change the MAJ Wigand settings. 1. In the Configuration Tools MA1xx MA5xx folder. Right-click on the Configuration Tool.exe file then click on the Run as Administrator. Please note that you have to run the configuration tool as an administrator. 2. Enter the IP address of the MAJ reader and click on Connect. Please note that the Port address is 11010 by default.

3. When the Configuration tool is connected to the reader you should see a screen like this. On this screen on the left size you will find all the settings of the MAJ reader. 4. Click on the [+] send id wiegand to expand the id wiegand settings.

5. To change the settings just double-click on the setting that you want to change. Then enter the value and click on update. Here is the list of the different settings for MAJ. Send id wiegand 26bit 30bit 34bit 38bit Custom Format 0.0 0.0 0.0 0.0 Frame Length 26 30 34 38 ID Format 9.16 13.16 13.20 13.24 Site Format 1.8 1.12 1.12 1.12 Start Format 2.12 2.14 2.16 2.18 Stop Format 3.12 3.14 3.16 3.18 Installing SAGEM Drivers and DLL s Wen running SAGEM with Softwin3 you need to install some software and dll files for the SAGEM readers to work on the Softcon software. This will allow you to enroll finger prints and then to download the finger print templates to the SAGEM readers. The drivers can be located on the Softcon CD or you can download the drivers from the Softcon website. Please note that there are different drivers that must be installed for each SAGEM component. Make sure to read the below setting carefully before installing. Don t install all the below drivers if you don t have the components.

Installing Morpho Smart Dongle The MSO reader is used to enroll finger prints to Softwin3 card database. This unit also stores the VERIF license for enrolling and the MACI license for downloading the finger print templates to the SAGEM readers. Please note that when purchasing the MSO reader to ask if the reader has a VERIF and MACI license installed. In the SAGEM drivers folder located on the Softcon CD or the files that you downloaded. 1. Locate the folder called. Sagem MorphoSmart USB 32 bits Driver Or Sagem MorphoSmart USB 64 bits Driver Choose the folder that corresponds to the Windows Operating System that is installed on the PC. 2. Run the Sagem MorphoSmart USB bits Driver.exe

3. Click on Next. 4. Click on Next.

5. Click on Install. 6. Click on Finish when the installation is complete.

Installing the Sagem Securite License Protection software. This software will allow you to view the license installed on the MSO reader. Also this software allows you to add a new license. In the SAGEM drivers folder located on the Softcon CD or the files that you downloaded. 1. Run the file called SagemSecurite_Licence_Protection_Installer.exe 2. Click on next.

3. Select Everyone and then Click on Next. 4. Click on Install.

5. Click on Close when the installation is complete. Copying and activating the dll files There are a couple of dll files that needs to be copied to the windows operating system. Then you need to activate the dll files with command prompt. This is so that the Softcon software knows where to grab the licenses when enrolling finger prints or downloading finger print templates to the SAGEM readers. Please note to check what windows operating system is installed on the PC. If it is a 64bit windows or a 32bit windows operating system. To see what Windows Operating System is installed on the PC follow these steps. Right-click on My Computer Click on Properties This screen will show you what windows Operating System is installed on the PC.

Copying the DLL files In the Softwin3 installation folder you will find a folder called Sagem. 1. Copy all 5 dll files. 2. Double click on Local Disk C: 3. Double click on Windows folder. 4. Paste the dll files in the SysWOW64 if you have a 64bit Windows. 5. Paste the dll files in the System32 if you have a 32bit Windows. OR

Activating the dll files Part 1 First you need to activate the VERIF license dll s. This will allow Softwin3 to enroll finger prints on the system. Please note that you need to run the Command Prompt (CMD) as an Administrator for the following commands to work. Follow these steps very carefully and make sure that they execute successfully. 1. Copy the below command into CMD and press enter. bcdedit /set nx AlwaysOff Now restart PC. 2. Copy the below command into CMD and press enter. cd c:\softwin3\exe

3. Copy the below command into CMD and press enter. c:\windows\microsoft.net\framework\v2.0.50727\regasm /codebase Sagem.MorphoKit.dll 4. Copy the below command into CMD and press enter. c:\windows\microsoft.net\framework\v2.0.50727\regasm /codebase Sagem.MorphoKit.AcquisitionComponent.dll 5. Copy the below command into CMD and press enter. c:\windows\microsoft.net\framework\v2.0.50727\regasm /codebase ActiveMKit_Enroll.dll

6. Copy the below command into CMD and press enter. ActiveMKit_Matcher /RegServer Activating the dll files Part 2 Now you need to activate the MACI license dll s. This dll files allows the Softwin3 software to download the finger print templates to the SAGEM readers. Please note that you need to run the Command Prompt (CMD) as an Administrator for the following commands to work 1. Copy the below command into CMD and press enter. If you are running a Windows 32Bit Operating system. cd c:\windows\system32 Or 2. Copy the below command into CMD and press enter. If you are running a Windows 32Bit Operating system. cd c:\windows\syswow64

3. Copy the below command into CMD and press enter. Then click on OK on the next screen. regsvr32 Active_MACI.dll Setting up SAGEM readers on Softwin3 Now you will learn how to setup SAGEM readers in the Softwin3 Software. This document will only show you how to use the FP Reader set-up and the FP App. You still need to add all the other changes yourself like CommsInterface Set-up, Controller Set-up, Reader Set-up etc. FP Reader Set-up Please make the following changes to the columns in FP Reader Set-up: Column Name Name Reader Type PC IP Address CD Min CD Max Vis Min Vis Max Enroll Save Using CardNo Consolidation 2FP Acquisition Description Fingerprint reader name. Fingerprint reader reference. Fingerprint Reader Type. Reference of PC witch fingerprint readers is connected. IP Address of fingerprint reader. Minimum user card data. Maximum user card data. Minimum visitor card data. Maximum visitor card data. Save user record to fingerprint reader during enrolment session. Send card number to fingerprint reader, else reference. Use 3 fingers capture to increase quality. Use two acquisitions per finger. Please note that you need to setup the SAGEM readers and the MSO Enrolment reader in the FP Reader Set-up.

FP App setup Please make the following changes to the columns in FP App Setup: Column Name App FP Reader Description Application ID of the fingerprint reader. Reference number of the fingerprint reader used by the application.